Empowering Scientific Discovery

Jiebi Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandParker
OriginUnited Kingdom
ModelLCM20
Calibration StandardsACFTD & MTD
Channel Count6
Detection PrincipleSingle-Point Source Laser (SPSL) Light Scattering
DisplayIntegrated LCD Handheld Unit
Data Storage300 Test Records
Pressure RatingUp to 420 bar
Flow CompatibilityUp to 400 L/min (with system integration)
CommunicationRS232 @ 9600 baud
ComplianceISO 4406, ISO 11171, NAS 1638, ASTM D6786
SoftwareDAT μm Trend Analysis Suite (free firmware updates included)
Optional AccessoriesBarcode Scanner, Built-in Thermal Printer, Relay Output for External Equipment Control
ServiceAnnual calibration support via Parker Authorized Service Centers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
ModelSA1900-0
Instrument TypeOptical Particle Counter
Compliance StandardsIP 565, NB/SH/T 0868, ASTM D7647, ISO 4406, ISO 60970, ASTM D6786, NAS 1638, AS 4059F, ISO 11171, ISO 11500, SAE J183, SAE J749D, GOST 17216, GB/T 5930, GJB 420A–1996, GJB 420B–2006, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012
Sample Viscosity RangeUp to 400 cSt (tested with in-service lubricants, hydraulic fluids, and insulating oils)
Sealing MaterialFFKM (perfluoroelastomer)
Integrated Pressure PumpYes
Analysis Time≤ 3 minutes per sample
Control ModesStandalone operation or PC-controlled via ProTrend software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOptimol
OriginGermany
ModelSRV®5
Instrument TypeReciprocating Tribometer
Maximum Friction Force2500 N
Friction Force Resolution1 N
Operating Temperature Range−35 °C to 1000 °C
Motion ModesReciprocating, Rotational, Tilted (0°–90°), Oscillatory, Non-Continuous Transition
Optional ModulesFSA (Friction Signal Analysis), Vacuum Chamber (High Vacuum), Nanopositioning Stage, Electrical Resistance Monitoring, Custom Fixture Integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelDSCvesta2
Temperature Range–180 to 725 °C (atmospheric: RT to 600 °C
mechanical cooling–95 to 725 °C)
Heating/Cooling Rateup to 100 °C/min
Gas Flow Range0–250 mL/min (resolution: 1 mL/min)
Heat Flow Range±1000 mW
Noise Level< 0.05 µW
Baseline Repeatability (–70 to 300 °C)≤ 10 µW
Enthalpy Sensitivity0.1 µW
Sensor TypeHeat-Flow-Type Metallic Sensor with vestaeye® Self-Diagnostic Function
Furnace MaterialPure Silver or Pure Platinum
Calibration Standards≥5 Certified Reference Materials (including Indium, Zinc, Tin, Bismuth, Lead)
Software FeaturesDual-data logging (raw + corrected), LIMS integration support, export to Word, Excel, JPG, PDF
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelTG-DTA8122
Temperature RangeAmbient to 1100 °C (standard), up to 1500 °C (high-temperature option)
Heating RateUp to 100 °C/min
Balance SystemHorizontal differential triple-coil design
Max. Sample Mass1 g
TG Full Scale±250 mg (500 mg FS)
TG Sensitivity0.01 µg
DTA Full Scale±1000 µV (2000 µV FS)
Atmosphere OptionsAir, inert gas, vacuum, steam, controlled flow
Optional Autosampler24 sample positions + 3 reference + 5 calibration positions
Standard Operating ModesConstant Reaction Control (CRC), Step Isothermal Analysis (SIA), Dynamic Rate Control (DRC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
ModelSA1100-0
Instrument TypeOptical Particle Counter
Particle Size Range (ISO 11171)4 µm to >70 µm
Particle Size Range (ISO 4402)2 µm to >100 µm
Number of Sizing Channels16
Maximum Particle Count per Test60,000 particles/mL
Sample Viscosity Rangeup to 68 mm²/s (direct from bottle), up to 500 mm²/s at 10 bar
Sample Temperature Range0–70 °C
Flow Rate30 mL/min
Total Sample Volume per Test80 mL (including rinse) for IP 565
Maximum Inlet Pressure10 bar (310 bar optional)
Output Unitsparticles/mL or particles/10 mL
Cleanliness CodesCumulative & Differential per ISO 4406, NAS 1638, SAE AS4059, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012, GOST 17216, Defence Standards 91-091 & 91-86, ASTM D975, D6299, D7619, D7647, IP 565, IP 630
Calibration StandardISO 11171
Data InterfacesEthernet, USB
DisplayIntegrated touchscreen interface
Onboard SQC SoftwareCompliant with ASTM D6299 statistical quality control requirements
User AuthenticationPassword-protected access levels
Embedded Test Methods14 preconfigured methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKittiwake
OriginUnited Kingdom
ModelFG-K17400-KW
Instrument TypeResistive Particle Counter
Measurement Range0–2000 ppm
Accuracy±30 ppm
Operating Ambient Temperature0–65 °C
Power Supply24 V DC / 0.7 A
Weight17 kg
Dimensions380 × 44 × 32 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKittiwake
OriginUK
ModelFG
Temperature Range-20 to 65°C
Detection Threshold0.04 mm (ferrous), 0.135 mm (non-ferrous)
Output Signals2 × opto-isolated 4–20 mA, 1 × alarm contact (0.1 A max)
Communication InterfacesRS232, RS485 (Ethernet optional)
Fluid CompatibilityMineral oil, synthetic lubricants, emulsified oils
Max Operating Pressure10 bar
Power Supply18–30 VDC
Ingress ProtectionIP65
Weight1.5 kg (3.3 lb)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKittiwake
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFG-K16120-KW
PricingUpon Request
Communication InterfacesCAN Bus, RS232, RS485, Wireless Network
Sensor PortBSP 3/8″
Compatible FluidsMineral Oils, Synthetic Lubricants, Hydraulic Fluids
Fluid Temperature Range−20 to +65 °C
Maximum Operating Pressure10 bar
Power Supply18–30 VDC
Ingress Protection RatingIP65
Ferrous Debris Detection Range0–2000 ppm (by mass)
Weight2.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFORM DDI
Price RangeUSD 68,000 – 136,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKittiwake
OriginUnited Kingdom
ModelFG
Operating Temperature Range0–70°C
Ferrous Debris Detection Range0–2000 ppm (uncombined, by weight)
Oil Quality Index Scale0–100
Relative Humidity Measurement0–100% RH
Temperature Sensing Range−20–120°C
Analog Output4–20 mA
Digital InterfacesRS232, RS485, CAN bus, Wi-Fi
Maximum System Pressure10 bar
Maximum Oil Viscosity350 cSt @ 40°C
Power Supply18–30 V DC
Ingress Protection RatingIP65
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTAMSON
OriginNetherlands
ModelTV4000
Instrument TypeVacuum Capillary Viscometer
Viscosity Range0.0036–20,000 Pa·s
Temperature RangeAmbient to 230 °C
Temperature Stability±0.01 °C
Bath Volume40 L
Bath Opening Dimensions260 × 240 mm
Vacuum Pressure Range30–430 mbar (negative pressure)
Vacuum Accuracy±0.5 mbar
Compliant StandardsASTM D2171, SH/T 0557, IP 222, EN 12596, AASHTO T 202
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
ModelSA1800-2
Instrument TypeOptical Particle Counter
Compliant StandardsASTM D975, ASTM D6786, ASTM D7619, IP 565, IP 630, NB/SH/T 0868, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012, GB/T 5930
Measurement PrincipleLight Obscuration (LO)
Sample Throughput≤3 min per test
DisplayIntegrated graphical interface with trend visualization
Data InterfaceUSB port for export
Onboard FunctionsBuilt-in thermal printer, three pre-programmed test methods, PC-configurable via Partikel software
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0