Empowering Scientific Discovery

Jinan Shengtai Electronic Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSENTE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Benchtop Analyzer
ModelST108M1
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Range0.05–5.0 mg/L
Repeatability±3% RSD
Accuracy±2% of true value
LOD0.01 mg/L
Resolution0.01 mg/L
Single-Test Duration5 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSENTE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelST1900
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Instrument TypeBenchtop Laboratory Analyzer
Range0.05–5.0 mg/L as O₂
Repeatability≤4% RSD
Accuracy±5% of reading
LOD0.05 mg/L
Resolution0.02 mg/L
Sample Throughput7.5 min per test
Sample Capacity29 positions
Heating Zones6 independent water-bath stations
Reagent Stations5 (H₂SO₄, Na₂C₂O₄, KMnO₄, NaOH, DI water)
Titration Precision≤0.03 mL
Power Supply220 V / 50 Hz
Main Unit Power3300 W
Auto-sampler Power800 W
Dimensions (W×D×H)1000 × 710 × 700 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSENTE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelST600D
Instrument TypeLaboratory Benchtop System
Measurement Principle2-Hour Reflux Digestion (Dichromate Oxidation Method)
Detection Wavelength500 nm
Measurement Range16–700 mg/L COD
Accuracy≤ ±8%
Repeatability≤ ±5%
Limit of Detection (LOD)4 mg/L
Cycle Time per Batch~10 minutes
Throughput48 samples per batch
Cooling SystemIntegrated Compressor-Based Closed-Loop Circulation
ComplianceGB 11914–1989 & HJ 828–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSENTE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic Instrument
ModelST800L
ApplicationLaboratory-Based Water Quality Analysis
Measurement PrincipleSpectrophotometry (UV-Vis)
Measuring ParametersTotal Phosphorus (TP) and Total Nitrogen (TN)
Measurement RangeTP: 0.01–0.6 mg/L
Detection Limit0.01 mg/L
Accuracy≤ ±5%
Instrument ClassBenchtop Automated Analyzer
Compliance StandardsGB 11893–1989 (TP), HJ 636–2012 (TN)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSENTE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelST106C
Digestion MethodReflux Digestion
Heating ModuleDual Independent Ceramic Heating Blocks
Batch Capacity1–6 Samples
Temperature Range0–300 °C
Temperature Accuracy±2 °C
Digestion Vessel Volume500 mL
Timer Accuracy±1 min
Chloride Tolerance1000–20000 mg/L Cl⁻
Nitrogen Flow ControlProportional Distribution Valve (0–100 mL/min, per channel)
Digestion Time Setting0–999 min
Cooling SystemIntegrated Compressor-Based Closed-Loop Cooling
Control SystemPLC + Touchscreen HMI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSENTE
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelST201A1
Instrument TypeLaboratory Benchtop System
Gas Flow Control6-channel linked rotameter (60–600 mL/min per channel, individually adjustable)
Heating MethodConstant-Temperature Water Bath
Temperature Range0–99 °C
Temperature Accuracy±1 °C (PID-controlled)
Power Rating2000 W
Safety FeaturesLeakage current protection
Automation FunctionsAutomatic acid addition, timed nitrogen purge, auto-fill/auto-drain water bath, real-time monitoring via integrated LCD touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandShentai (SENTE)
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelST106BW
Digestion MethodReflux Digestion
Heating ModuleDual Independent Heating Blocks
Batch Capacity15 Samples
Temperature Range0–200 °C
Temperature Accuracy±1 °C
Digestion Vessel Capacity220 mL
Timer Accuracy±1 min]