| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Liquid Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Rotameter |
| Detectable Elements | As, Sb, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn |
| Relative Standard Deviation (RSD) | ≤0.7% |
| Linear Dynamic Range | ≥3 orders of magnitude |
| Detection Limits | As, Se, Bi, Pb, Sb, Te, Sn, Zn < 0.01 µg/L |
| Photomultiplier Tube (PMT) Wavelength Range | 160–320 nm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | <1 ppb (typ. for key elements) |
| Precision (RSD) | ≤1% |
| Stability (RSD, 4h) | ≤2% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | 6 pm / 7 pm / 10 pm @ 257.610 nm (Mn line, measured) |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | DMA-1 |
| Instrument Type | Portable |
| Measurement Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.1 ng |
| Linear Range | 0–1500 ng |
| Repeatability (RSD) | ≤1.0% |
| Linearity Error | ±10% |
| Sample Throughput | 2–5 min per analysis |
| Regulatory Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 7450 |
| Instrument Type | Water & Soil VOC Analyzer |
| Sample Capacity | 72-position |
| Trap Temperature | Ambient (Room-Temperature Capture) |
| Purge Heater Temperature | Up to 100 °C |
| Sample Chilling Temperature | 4 °C |
| Internal Standard Delivery | 2 µL Quantitative Loop |
| Moisture Removal | Integrated On-line Dual-Path Dehumidification |
| System Inertness | Entire Fluid Path Constructed of SilcoNert®-Treated Stainless Steel and Fused Silica |
| Foam Detection | Real-time Optical Foam Sensor |
| Sample Compatibility | Aqueous Matrices, Soil/Sediment Slurries (via Methanol Extraction), and Solid Samples with Spiking Protocol |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LabMS 3000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Software Platform | HiMass Intelligent Workstation |
| Safety Architecture | Five-Level Integrated Safety Protection System |
| Maintenance Logging | Automated Scheduled Maintenance Audit Trail |
| Sample Introduction | Integrated High-Matrix Sample Introduction System with On-Line Argon Dilution and Oxygen-Added Organic Sample Desolvation |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC600 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Sample Loop Capacity | 2 mL (120-position tray) |
| Injection Volume Range | 1–250 µL |
| Column Oven Temperature Range | Ambient to 120 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 10 Hz |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 6150 |
| Pyrolyzer Type | Filament-Heated Pyrolyzer |
| Temperature Range | Ambient to 1300 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Cooling Time | <18 s (from 650 °C to <50 °C, gas-free) |
| Reproducibility | RSD ≤1.5% (polystyrene standard) |
| Transfer Line Max Temp | 350 °C |
| Programmable Steps per Method | Up to 10 |
| GC Trigger Support | Per-step synchronized GC start signal |
| Sample Tube | Reusable fused-silica quartz tube |
| Optional Autosampler | 48-position |
| Brand | LabTech |
|---|---|
| Origin | Imported |
| Manufacturer | LabTech |
| Model | MAX-L |
| Principle | Cold Vapor Atomic Absorption (CVAAS) |
| Detection Limit | 0.1 ppt |
| Repeatability | <1.5% RSD |
| Linearity Error | ±0.2% |
| Brand | LabTech |
|---|---|
| Model | PT3000 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-Made) |
| Pricing | Available Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Model | LC600 Binary High-Pressure Gradient HPLC System |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | PC-controlled with audit trail capability (21 CFR Part 11 compliant configuration available) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | LabICP 2000 ICP-OES |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Optical Design | Prism + High-Resolution Echelle Grating Two-Dimensional Cross-Dispersed System |
| Detector | Megapixel Large-Area CCD |
| Plasma Orientation | Vertical Torch |
| Observation Modes | Radial, Axial, Dual-View, and Attenuated Variants |
| Gas Control | Mass Flow Controllers (MFCs) for All Gases |
| Software | HiICP Platform with Real-Time & Offline Analysis Capabilities |
| Cooling | Thermoelectrically Cooled CCD with MPS Thermal Isolation Structure |
| Purge | Positive-Pressure Sealed Spectrometer Chamber with Independent Front-Optics Purge |
| RF Generator | Solid-State Crystal-Controlled RF Source with Real-Time Power Monitoring |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 7550s |
| Instrument Type | Dual-Stage Thermal Desorber |
| Sample Capacity | 72 positions |
| Cold Trap Temperature Range | –40 °C to +400 °C (Peltier-assisted pre-concentration) |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve Operating Temperature | Up to 350 °C |
| Detection Compatibility | Universal interface for GC and GC-MS systems (all major brands) |
| Carrier Gas Control | Precision mass flow control with split capability |
| Sample Preservation Mode | Integrated cryo-trap bypass & fraction collection |
| Dry-Purge Function | Automated in-line dry-purge of traps and transfer lines |
| Tube Conditioning | On-board thermal conditioning of sorbent tubes (up to 400 °C) |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 6200 |
| Pyrolyzer Type | Filament (Wire) Pyrolyzer |
| Temperature Range | Ambient to 1300 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Cooling Rate | From 650 °C to <50 °C in ≤18 s (no cryogenic gas required) |
| Reproducibility | RSD ≤1.5% (polystyrene standard) |
| Transfer Line Max Temp | 350 °C |
| Programmable Steps per Method | Up to 10 |
| Sample Capacity | 48-position auto-sampler (optional) |
| Operating Interface | Integrated touchscreen with one-touch start |
| Heating System | Platinum RTD-integrated resistive filament |
| Atmosphere Control | Switchable carrier/reactive gases (e.g., He, air) |
| Modes | Direct-to-GC and Cold Trap (cryo-trap optional) |
| Software-Controlled Mode Switching | Yes |
| Optional Functions | Thermal Desorption, Dynamic Headspace, Electronic Flow Control, Spectral Library Integration |
| Brand | LabTech |
|---|---|
| Model | MAX-S |
| Principle | Catalytic Thermal Decomposition–Gold Amalgamation–Cold Vapor Atomic Absorption Spectrometry (CV-AAS) |
| Detection Limit | 0.0005 ng Hg |
| Linear Range | 0–30,000 ng Hg (7 orders of magnitude) |
| Analysis Time | 2–5 min per sample |
| Sample Forms | Solid, liquid, and gas matrices without pretreatment |
| Repeatability | RSD < 3% (n = 10 at 10 ng level) |
| Calibration Stability | 3–6 months between standard curve verification |
| Compliance | Designed for GLP/GMP environments |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | DMA-80 evo |
| Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 0.0002 ng |
| Linear Range | 0–30,000 ng |
| Repeatability (RSD) | ≤1.0% |
| Recovery Rate | >98.5% at 1000 ng |
| Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Model | LabAA 2000 |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Resolution | Mn Doublet (279.5–279.8 nm), Valley-to-Peak Ratio ≤30% at 279.5 nm |
| Sensitivity | Flame Mode — Cu Characteristic Concentration ≤0.035 mg/L |
| Precision (RSD) | Flame Cu (2 ppm) ≤1.0% |
| Detection Limits | Flame — sub-ppb to ppm range |
| Baseline Stability | ≤±0.003 Abs over 30 min at Cu 324.8 nm |
| Brand | LabTech |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | I-Lab 180 |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | PY1000 Pyrolyzer |
| Pricing | Available Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CDS 5200 |
| Price | Upon Request |
| Pyrolysis Temperature Range | Ambient to 1400 °C (adjustable in 0.1 °C increments) |
| Temperature Accuracy | ±0.1 °C |
| Maximum Pressure Rating | 500 PSI (3400 kPa) |
| Heating Rate (Pulse Mode) | 10–20,000 °C/sec |
| Heating Rate (Programmed Mode) | 0.01–999.9 °C/sec or 0.01–999.9 °C/min |
| Programmable Steps per Run | Up to 8 steps with independent GC trigger per step |
| Transfer Line Max Temp | 350 °C |
| Interface Temp | ≥350 °C |
| Sample Path Material | Inert (e.g., SilcoNert®-treated stainless steel or fused silica) |
| Optional In-line Cold Trap | Integrated cryo-focusing with thermal desorption |
| Atmosphere Control | N₂, air, O₂, He, or custom gas (via external mass flow controller) |
| Catalytic Reactor | 3″ × 1/4″ OD 316 stainless steel, rated to 800 °C, user-replaceable catalyst bed |