Empowering Scientific Discovery

Labtech Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pumps
Waste Liquid DisposalPeristaltic Pump Extraction
Hydride Generation ModeVapor Generation / Hydride Generation
Gas Flow ControlRotameter
Detectable ElementsAs, Sb, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn
Relative Standard Deviation (RSD)≤0.7%
Linear Dynamic Range≥3 orders of magnitude
Detection LimitsAs, Se, Bi, Pb, Sb, Te, Sn, Zn < 0.01 µg/L
Photomultiplier Tube (PMT) Wavelength Range160–320 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSequential Scanning ICP-OES
Detection Limit<1 ppb (typ. for key elements)
Precision (RSD)≤1%
Stability (RSD, 4h)≤2%
Wavelength Range165–900 nm
Optical Resolution6 pm / 7 pm / 10 pm @ 257.610 nm (Mn line, measured)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMILESTONE
OriginItaly
ModelDMA-1
Instrument TypePortable
Measurement PrincipleCatalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit≤0.1 ng
Linear Range0–1500 ng
Repeatability (RSD)≤1.0%
Linearity Error±10%
Sample Throughput2–5 min per analysis
Regulatory ComplianceEPA Method 7473, HJ 923–2017, GB 5009.17–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCDS Analytical
OriginUSA
Model7450
Instrument TypeWater & Soil VOC Analyzer
Sample Capacity72-position
Trap TemperatureAmbient (Room-Temperature Capture)
Purge Heater TemperatureUp to 100 °C
Sample Chilling Temperature4 °C
Internal Standard Delivery2 µL Quantitative Loop
Moisture RemovalIntegrated On-line Dual-Path Dehumidification
System InertnessEntire Fluid Path Constructed of SilcoNert®-Treated Stainless Steel and Fused Silica
Foam DetectionReal-time Optical Foam Sensor
Sample CompatibilityAqueous Matrices, Soil/Sediment Slurries (via Methanol Extraction), and Solid Samples with Spiking Protocol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelLabMS 3000
Instrument TypeQuadrupole ICP-MS
Application EnvironmentLaboratory
Detection PrincipleInductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter
Software PlatformHiMass Intelligent Workstation
Safety ArchitectureFive-Level Integrated Safety Protection System
Maintenance LoggingAutomated Scheduled Maintenance Audit Trail
Sample IntroductionIntegrated High-Matrix Sample Introduction System with On-Line Argon Dilution and Oxygen-Added Organic Sample Desolvation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelLC600
Instrument TypeConventional High-Performance Liquid Chromatograph (HPLC)
Flow Rate Range0.001–9.999 mL/min
Maximum Operating Pressure42 MPa
Sample Loop Capacity2 mL (120-position tray)
Injection Volume Range1–250 µL
Column Oven Temperature RangeAmbient to 120 °C
UV-Vis Wavelength Range190–600 nm
Data Acquisition Frequency10 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCDS Analytical
OriginUSA
Model6150
Pyrolyzer TypeFilament-Heated Pyrolyzer
Temperature RangeAmbient to 1300 °C (1 °C increment)
Temperature Accuracy±0.1 °C
Cooling Time<18 s (from 650 °C to <50 °C, gas-free)
ReproducibilityRSD ≤1.5% (polystyrene standard)
Transfer Line Max Temp350 °C
Programmable Steps per MethodUp to 10
GC Trigger SupportPer-step synchronized GC start signal
Sample TubeReusable fused-silica quartz tube
Optional Autosampler48-position
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginImported
ManufacturerLabTech
ModelMAX-L
PrincipleCold Vapor Atomic Absorption (CVAAS)
Detection Limit0.1 ppt
Repeatability<1.5% RSD
Linearity Error±0.2%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
ModelPT3000
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic (China-Made)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeConventional High-Performance Liquid Chromatograph (HPLC)
ModelLC600 Binary High-Pressure Gradient HPLC System
ComplianceDesigned for GLP/GMP-aligned laboratories
SoftwarePC-controlled with audit trail capability (21 CFR Part 11 compliant configuration available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelLabICP 2000 ICP-OES
Instrument TypeFull-Spectrum Simultaneous ICP-OES
Optical DesignPrism + High-Resolution Echelle Grating Two-Dimensional Cross-Dispersed System
DetectorMegapixel Large-Area CCD
Plasma OrientationVertical Torch
Observation ModesRadial, Axial, Dual-View, and Attenuated Variants
Gas ControlMass Flow Controllers (MFCs) for All Gases
SoftwareHiICP Platform with Real-Time & Offline Analysis Capabilities
CoolingThermoelectrically Cooled CCD with MPS Thermal Isolation Structure
PurgePositive-Pressure Sealed Spectrometer Chamber with Independent Front-Optics Purge
RF GeneratorSolid-State Crystal-Controlled RF Source with Real-Time Power Monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCDS Analytical
OriginUSA
Model7550s
Instrument TypeDual-Stage Thermal Desorber
Sample Capacity72 positions
Cold Trap Temperature Range–40 °C to +400 °C (Peltier-assisted pre-concentration)
Desorption Temperature RangeAmbient to 400 °C
Valve Operating TemperatureUp to 350 °C
Detection CompatibilityUniversal interface for GC and GC-MS systems (all major brands)
Carrier Gas ControlPrecision mass flow control with split capability
Sample Preservation ModeIntegrated cryo-trap bypass & fraction collection
Dry-Purge FunctionAutomated in-line dry-purge of traps and transfer lines
Tube ConditioningOn-board thermal conditioning of sorbent tubes (up to 400 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCDS Analytical
OriginUSA
Model6200
Pyrolyzer TypeFilament (Wire) Pyrolyzer
Temperature RangeAmbient to 1300 °C (1 °C increment)
Temperature Accuracy±0.1 °C
Cooling RateFrom 650 °C to <50 °C in ≤18 s (no cryogenic gas required)
ReproducibilityRSD ≤1.5% (polystyrene standard)
Transfer Line Max Temp350 °C
Programmable Steps per MethodUp to 10
Sample Capacity48-position auto-sampler (optional)
Operating InterfaceIntegrated touchscreen with one-touch start
Heating SystemPlatinum RTD-integrated resistive filament
Atmosphere ControlSwitchable carrier/reactive gases (e.g., He, air)
ModesDirect-to-GC and Cold Trap (cryo-trap optional)
Software-Controlled Mode SwitchingYes
Optional FunctionsThermal Desorption, Dynamic Headspace, Electronic Flow Control, Spectral Library Integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
ModelMAX-S
PrincipleCatalytic Thermal Decomposition–Gold Amalgamation–Cold Vapor Atomic Absorption Spectrometry (CV-AAS)
Detection Limit0.0005 ng Hg
Linear Range0–30,000 ng Hg (7 orders of magnitude)
Analysis Time2–5 min per sample
Sample FormsSolid, liquid, and gas matrices without pretreatment
RepeatabilityRSD < 3% (n = 10 at 10 ng level)
Calibration Stability3–6 months between standard curve verification
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMilestone
OriginItaly
ModelDMA-80 evo
PrincipleCatalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit0.0002 ng
Linear Range0–30,000 ng
Repeatability (RSD)≤1.0%
Recovery Rate>98.5% at 1000 ng
ComplianceEPA Method 7473, HJ 923–2017, GB 5009.17–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame and Graphite Furnace AAS
ModelLabAA 2000
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorSolid-State Detector
Background CorrectionD₂ Lamp + Self-Absorption Method
ResolutionMn Doublet (279.5–279.8 nm), Valley-to-Peak Ratio ≤30% at 279.5 nm
SensitivityFlame Mode — Cu Characteristic Concentration ≤0.035 mg/L
Precision (RSD)Flame Cu (2 ppm) ≤1.0%
Detection LimitsFlame — sub-ppb to ppm range
Baseline Stability≤±0.003 Abs over 30 min at Cu 324.8 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginTianjin, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelI-Lab 180
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (China-made)
ModelPY1000 Pyrolyzer
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelCDS 5200
PriceUpon Request
Pyrolysis Temperature RangeAmbient to 1400 °C (adjustable in 0.1 °C increments)
Temperature Accuracy±0.1 °C
Maximum Pressure Rating500 PSI (3400 kPa)
Heating Rate (Pulse Mode)10–20,000 °C/sec
Heating Rate (Programmed Mode)0.01–999.9 °C/sec or 0.01–999.9 °C/min
Programmable Steps per RunUp to 8 steps with independent GC trigger per step
Transfer Line Max Temp350 °C
Interface Temp≥350 °C
Sample Path MaterialInert (e.g., SilcoNert®-treated stainless steel or fused silica)
Optional In-line Cold TrapIntegrated cryo-focusing with thermal desorption
Atmosphere ControlN₂, air, O₂, He, or custom gas (via external mass flow controller)
Catalytic Reactor3″ × 1/4″ OD 316 stainless steel, rated to 800 °C, user-replaceable catalyst bed