- All
- Favorite
- Popular
- Most rated
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Extraction Principle | Microwave-Assisted Solvent-Free Microwave Extraction (SFME) |
| Capacity Options | 2 L, 5 L, 12 L (lab & pilot) |
| Typical Extraction Time | 5–8 min (first drop), ~40 min (complete yield) |
| Output Compatibility | Direct GC-MS injection without solvent removal |
| Compliance | Designed for GLP-compliant workflows |
| Software Interface | Touchscreen GUI with method storage, real-time power/temperature monitoring, and exportable extraction logs (CSV, PDF) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HPSE |
| Instrument Type | Solid-Liquid Extraction System |
| Sample Throughput | Up to 6 parallel extraction cells |
| Extraction Vessel Capacity | Compatible with 1–100 mL vessels |
| Temperature Range | Programmable, typically 50–200 °C (application-dependent) |
| Pressure Range | Up to 20 MPa (3,000 psi), dynamically regulated |
| Pump Flow Rate | 100 mL/min |
| Sealing Mechanism | Auto-actuated force-assisted sealing |
| Enclosure | Fully sealed, ventilation-integrated chassis |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Application | Rapid total fat determination in food and feed samples |
| Sample throughput | 15 positions |
| Sample mass range | 3–15 g |
| Total process time | ≤ 3 hours |
| Temperature control | Full-vessel infrared temperature monitoring |
| Automation | Integrated balance interface for automatic mass data import and calculation |
| Extraction methodology | Microwave-assisted acid hydrolysis coupled with solvent extraction |
| Stirring | Built-in magnetic stirring system |
| Compliance context | Designed to support AOAC 991.36, ISO 1443, and USP <467> workflows |
| Brand | LabTech |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Origin | Imported |
| Model | Sepaths UP |
| Automation Level | Fully Automated |
| Number of Channels | Multi-channel |
| Extraction Mode | Membrane-based SPE |
| Flow Rate Control | 0–120 mL/min |
| Solvent Selection | Up to 8 different solvents |
| Sample Capacity | 12 samples simultaneously |
| Sample Loading Volume | 1–20 mL |
| Wetted Materials | PTFE, Stainless Steel |
| Brand | LabTech |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Isotope-S8-2 |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Flex-HPSE 1H |
| Pricing | Available upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SPE2000 |
| Automation Level | Fully Automated |
| Channel Configuration | 6- or 8-channel parallel operation |
| Extraction Format | Cartridge-based SPE |
| Column Compatibility | 1 mL, 3 mL, and 6 mL SPE cartridges |
| Sample Volume Range | 0–20 L (with optional large-volume module) |
| Integrated Online Filtration | Yes, for particulate-laden samples |
| Sample Position Capacity | Up to 60 positions (6-channel) or 80 positions (8-channel) |
| Solvent Contact Materials | Chemically resistant PTFE, PEEK, and borosilicate glass |
| Regulatory Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software |
| User Interface | Android-based 10.1″ capacitive touchscreen with graphical workflow editor |
| Brand | LabTech |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PrepElite-SV |
| Automation Level | Fully Automatic |
| Number of Channels | Multi-channel |
| Extraction Mode | Column-based SPE |
| Flow Rate Control | 0–120 mL/min |
| Solvent Types Supported | 8 distinct solvents |
| Sample Capacity | 124 positions |
| Sample Loading Volume | 1–6 mL |
| Wetted Materials | Borosilicate Glass |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Extrapid |
| Automation Level | Manual |
| Number of Channels | 4 |
| Extraction Format | Column and Disc (Dual-Format) |
| Flow Rate Control | 1–45 mL/min (per channel, independently adjustable via precision PTFE micro-flow valves) |
| Solvent Reservoir Capacity | 8 independent solvent ports |
| Sample Throughput | Simultaneous processing of multiple samples |
| Maximum Sample Load Volume | Up to 20 L per channel |
| Wetted Materials | Borosilicate glass, PTFE, stainless steel (316) |
| Compliance | Compatible with ASTM D7279, ISO 16775, USP <621>, and GLP/GMP-aligned workflows |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Flex-HPSE |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | 50–200 °C |
| Pressure Range | 10.3–20.6 MPa |
| Extraction Cell Volume | 15–45 mL |
| Extraction Time per Cycle | 12–18 min |
| Dimensions (W×D×H) | 1112 × 939 × 672 mm |
| Throughput | Dual-channel, 30-position automated sequential processing |
| Compliance | Designed for ISO 13877, EPA Method 3545A, ASTM D7699, and USP <467> applications |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AutoEmpore |
| Channel Configuration | Multi-channel |
| Extraction Technology | Membrane-based SPE |
| Sample Throughput | Up to 3 × 1 L water samples in ≤10 min (enrichment only) |
| Flow Rate | Up to 120 mL/min |
| Supported Formats | 25 mm & 47 mm SPE membranes |
| Integrated Features | On-line filtration, on-line water removal, independent dual-pump per channel, membrane-cartridge hybrid compatibility |
| Software Control | Mobile/tablet-based APP with method library, audit trail, and remote monitoring capability |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Background Performance | Ultra-low PFAS and phthalate background via shortened fluidic path and inert wetted materials |
| Membrane Source | In-house manufactured Empore™-compatible extraction membranes |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SPE 1000 PLUS |
| Automation Level | Fully Automated |
| Channel Configuration | 1–8 Parallel Channels |
| Extraction Format | Cartridge-Based SPE |
| Solvent Reservoirs | 8 Independent Solvent Ports |
| Sample Capacity | 1–8 Samples Simultaneously |
| Sample Loading Volume | 0–20 L per Sample |
| Wetted Materials | PTFE (Polytetrafluoroethylene) |
| Compliance | Designed for GLP/GMP-Compliant Laboratories |
| Software | Integrated Control with Audit Trail & User Management |
| Brand | LabTech |
|---|---|
| Origin | USA |
| Manufacturer | LabTech |
| Product Type | Imported |
| Model | Isotope-P8 |
| Pricing | Available Upon Request |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Type | Microwave-Assisted Extraction (MAE) System |
| Sample Capacity | Up to 44 sealed vessels per run |
| Cycle Time | ≤40 min for full batch |
| Vessel Type | Disposable borosilicate glass extraction vessels |
| Temperature Control | Full-vessel infrared temperature monitoring |
| Safety Compliance | <0.05 mW/cm² microwave leakage (IEC 61000-3-2, IEC 62233), integrated stainless steel monolithic cavity, active pressure-relief “sliding wall” safety door |
| Solvent Compatibility | Polar (e.g., methanol, acetone), non-polar (e.g., hexane, DCM), and mixed solvents |
| Stirring | Integrated automatic magnetic stirring per vessel |
| Software | Preloaded method library, touchscreen GUI, audit-trail-capable operation log |
Show next