Empowering Scientific Discovery

Labtech Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pumps
Waste Liquid DisposalPeristaltic Pump Extraction
Hydride Generation ModeVapor Generation / Hydride Generation
Gas Flow ControlRotameter
Detectable ElementsAs, Sb, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn
Relative Standard Deviation (RSD)≤0.7%
Linear Dynamic Range≥3 orders of magnitude
Detection LimitsAs, Se, Bi, Pb, Sb, Te, Sn, Zn < 0.01 µg/L
Photomultiplier Tube (PMT) Wavelength Range160–320 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSequential Scanning ICP-OES
Detection Limit<1 ppb (typ. for key elements)
Precision (RSD)≤1%
Stability (RSD, 4h)≤2%
Wavelength Range165–900 nm
Optical Resolution6 pm / 7 pm / 10 pm @ 257.610 nm (Mn line, measured)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelLabICP 2000 ICP-OES
Instrument TypeFull-Spectrum Simultaneous ICP-OES
Optical DesignPrism + High-Resolution Echelle Grating Two-Dimensional Cross-Dispersed System
DetectorMegapixel Large-Area CCD
Plasma OrientationVertical Torch
Observation ModesRadial, Axial, Dual-View, and Attenuated Variants
Gas ControlMass Flow Controllers (MFCs) for All Gases
SoftwareHiICP Platform with Real-Time & Offline Analysis Capabilities
CoolingThermoelectrically Cooled CCD with MPS Thermal Isolation Structure
PurgePositive-Pressure Sealed Spectrometer Chamber with Independent Front-Optics Purge
RF GeneratorSolid-State Crystal-Controlled RF Source with Real-Time Power Monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabTech
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame and Graphite Furnace AAS
ModelLabAA 2000
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorSolid-State Detector
Background CorrectionD₂ Lamp + Self-Absorption Method
ResolutionMn Doublet (279.5–279.8 nm), Valley-to-Peak Ratio ≤30% at 279.5 nm
SensitivityFlame Mode — Cu Characteristic Concentration ≤0.035 mg/L
Precision (RSD)Flame Cu (2 ppm) ≤1.0%
Detection LimitsFlame — sub-ppb to ppm range
Baseline Stability≤±0.003 Abs over 30 min at Cu 324.8 nm
Show next