BrandLAUDA
OriginGermany
ModelVS 30 O
Timer Range1 min – 99.9 h
Oscillation Frequency20–250 rpm
Amplitude32 mm
Platform Quantity1
Operating Ambient Temperature10–50 °C
Tray Dimensions (W × D)676 × 540 mm
Max Load Capacity30 kg
Power Consumption0.09 kW
External Dimensions (W × D × H)705 × 607 × 160 mm
Weight40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 8 B
Instrument TypeAir-Bath Incubated Shaker / Platform Shaker
Timer Range1 min to 99:59 h
Oscillation Frequency20–300 rpm
Oscillation Amplitude20 mm
Number of Platforms1
Max Load Capacity8 kg
Power Consumption0.07 kW
Dimensions (W×D×H)350 × 355 × 160 mm
Power Supply230 V, 50/60 Hz
Platform MaterialAnodized Aluminum
Housing MaterialElectrogalvanized Steel with Powder Coating
MotorAC Motor with Overload Protection
Speed StabilityLoad-Independent Constant Speed
Optional InterfacesRS-232
Optional AccessoriesNon-slip Mat (A000041), Anti-slip Tray Holder (A000042), Oscillation Tray (A000047), Universal Tray (A000048)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVC 1200 W
Temperature Range-20 °C to 80 °C
Temperature Stability±0.05 K
Dimensions450 × 550 × 650 mm
Power Consumption3.3 kW (max)
Heating Power2.25 kW (max)
Pump Flow Rate28 L/min @ 0.9 bar
Reservoir Volume15 L
Cooling MediumWater or water/glycol mixture (non-flammable)
Interface OptionsRS-232/485, Profibus, Ethernet-USB, analog I/O, digital contact modules
Control SystemPID-based electronic controller with TFT display, 150-segment programmable scheduler
ComplianceCE, RoHS, conforms to EN 61000-6-2/-6-4 EMI/EMC standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVC 7000 W
Temperature Range−20 °C to 80 °C
Temperature Stability±0.1 K
Dimensions (W×D×H)650 × 670 × 1250 mm
Power Consumption7.0 kW @ 20 °C
Pump Flow Rate37 L/min @ 3.2 bar
Fluid Capacity64 L
Weight122 kg
Cooling MediumWater or Water/Glycol Mixture (non-flammable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVC 10000 W
Temperature Range-20 °C to 80 °C
Temperature Stability±0.1 K
Temperature Uniformity±0.1 K
Dimensions650 × 670 × 1250 mm
Power Consumption10 kW @ 20 °C
Refrigeration Capacityup to 10.8 kW
Heating Capacityup to 15.8 kW
Fluid Reservoir Volume64 L
Max. Pump Flow Rate37 L/min @ 3.2 bar
Interface OptionsRS-232/485, Profibus, Ethernet-USB, Analog I/O, Digital Contact Module
Control SystemPID-based electronic controller with programmable logic (150 segments), TFT color display, SmartCool digital cooling management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUT 3505 W
Temperature Range−5 °C to 60 °C
Temperature Stability±0.5 K
Cooling/Heating Power35 kW
IP RatingIP54
Power Supply400 V / 3~ / 50 Hz or 460 V / 3~ / 60 Hz
Ambient Operating Range−15 °C to 50 °C
Heat Transfer FluidWater or Water/Glycol (non-flammable)
Communication InterfaceEthernet with Modbus TCP/IP
DisplayLCD with plain-text menu navigation
Pump PressureDigital display
Inlet/Outlet PortsStainless steel
Integrated ComponentsHigh-performance pump, stainless-steel heat exchanger, water-cooled condenser, particulate filter, Pt100 sensor input, 4–20 mA analog setpoint interface, digital I/O (ON/OFF, level alarm), optional external solenoid valve support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVC 3000 W
Temperature Range-20 °C to 80 °C
Temperature Stability±0.05 K
Dimensions550 × 650 × 970 mm
Power Consumption3.0 kW @ 20 °C
Pump Flow Rate37 L/min @ 3.2 bar
Reservoir Volume33 L
Cooling MediumWater or Water/Glycol (non-flammable)
Interface OptionsRS-232/485, Profibus, Ethernet-USB, Analog I/O, Digital Contact Modules
Control SystemPID-based electronic controller with TFT display, 150-segment programmable scheduler, SmartCool digital cooling management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 15 O
Timer Range1 min – 99:59 h
Oscillation Frequency20–300 rpm
Amplitude30 mm
Tray Quantity1
Operating Ambient Temperature10–50 °C
Tray Dimensions (W × D)330 × 330 mm
Max. Load Capacity8 kg
Power Consumption0.07 kW
Amplitude (additional spec)10 mm
Frequency Range (extended spec)20–500 rpm
Dimensions (W × D × H)350 × 355 × 160 mm
Weight11 kg
Power Supply230 V, 50/60 Hz
MotorAC motor with overload protection
ConstructionAnodized aluminum platform, electrogalvanized steel housing with powder coating
Control InterfaceDual LCD display, membrane keypad with symbolic icons
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 8 O
Timer Range1 min – 99:59 h
Oscillation Frequency20–500 rpm
Amplitude10 mm
Platform Quantity1
Operating Ambient Temperature10–50 °C
Tray Dimensions (W × D)330 × 330 mm
Max Load Capacity8 kg
Power Consumption0.07 kW
Dimensions (W × D × H)350 × 355 × 160 mm
Weight11 kg
Voltage/Frequency230 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 15 T
Timer Range1 min to 99:59 h
Oscillation Frequency2–50 rpm
Amplitude
Tray Quantity1
Tray Dimensions (W × D)450 × 450 mm
Max Load Capacity15 kg
Ambient Temperature Range10–50 °C
Power Consumption0.09 kW
Net Weight19 kg
Housing MaterialElectrogalvanized Steel with Powder Coating
Tray MaterialAnodized Aluminum
Drive MotorAC Motor with Overload Protection
Speed ControlDigital, Stepless, 0.5 rpm Resolution
Interface OptionRS-232 (Optional)
Noise LevelLow
DesignCompact, Balanced, Maintenance-Free Architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 15 R
Timer Range1 min to 99:59 h
Oscillation Frequency2–50 rpm
Amplitude
Tray Quantity1
Operating Ambient Temperature10–50 °C
Tray Dimensions (W × D)450 × 450 mm
Max Load Capacity15 kg
Power Consumption0.09 kW
External Dimensions (W × D × H)480 × 487 × 160 mm
Weight17 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 20 OH
Timer Range1 min – 99.9 h
Oscillation Frequency1–20 rpm
Ambient Temperature Range10–40 °C
Max. Power Consumption0.1 kW
Max. Load Capacity20 kg
Dimensions (W×D×H)770 × 700 × 715 mm
Weight68 kg
ConstructionPowder-coated, electrogalvanized steel housing
DriveOverload-protected DC motor with dynamic mass balancing
Bearing SystemDual-side ball-bearing tilt frame with sliding hub drive
Clamp MechanismHeight-adjustable stainless steel clamps, accommodates vessels up to Ø110 mm × H270 mm
Sample CapacityUp to 12 round or square containers under uniform loading
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVC 5000 W
Temperature Range−20 °C to +80 °C
Temperature Stability±0.05 K
Dimensions (W×D×H)550 mm × 650 mm × 970 mm
Power Consumption5.0 kW @ 20 °C
Pump Flow Rateup to 37 L/min @ 3.2 bar
Reservoir Volume33 L
Cooling MediumWater or water/glycol mixture (non-flammable)
Interface OptionsRS-232/485, Profibus, Ethernet-USB, Analog I/O, Digital Contact Module
Control SystemPID-based electronic controller with TFT display, 150-segment programmable scheduler
ComplianceCE, RoHS, conforms to EN 61000-6-2/-6-4 EMI/EMC standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 15 B
Timer Range1 min to 99:59 h
Oscillation Frequency20–300 rpm
Amplitude30 mm
Platform Quantity1
Max Load Capacity15 kg
Platform Dimensions (W × D)450 × 450 mm
Ambient Temperature Range10–50 °C
Power Consumption0.07 kW
Overall Dimensions (W × D × H)480 × 487 × 160 mm
Weight18 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 60 OI
Timer Range1 min – 999 h
Oscillation Frequency20–250 rpm
Amplitude30 mm
Temperature Range28–70 °C (water-cooled: 20–70 °C)
Chamber Volume68 L
Temperature Stability±0.2 °C
Power Supply230 V, 50/60 Hz
Max. Load12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 45 OI
Timer Range1 min – 999 h
Oscillation Frequency20–250 rpm
Amplitude25 mm
Temperature Range28–70 °C (20–70 °C with external cooling)
Chamber Volume45 L
Temperature Stability±0.2 °C
Tray Dimensions (W × D)420 × 270 mm
Internal Dimensions (W × D × H)420 × 270 × 320 mm
External Dimensions (W × D × H)710 × 650 × 710 mm
Weight72 kg
Power Supply230 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVS 150 OI
Timer Range1 min – 999 h
Oscillation Frequency20–250 rpm
Amplitude25–30 mm
Temperature Range28–70 °C (ambient-cooled: 20–70 °C)
Number of Shaking Platforms4
Internal Volume150 L
Platform Load Capacity20 kg
Temperature Stability±0.2 °C
Power Supply230 V, 50/60 Hz
Heating Power0.5 kW
Max. Power Consumption0.65 kW
Internal Dimensions (W×D×H)450 × 450 × 338 mm
External Dimensions (W×D×H)559 × 687 × 628 mm
ConstructionStainless steel interior cabinet, door lining & shaking platform
Cooling CoilIntegrated for sub-ambient operation
InterfaceRS232 serial port
SafetyDual-stage thermal cut-off (electronic PID + mechanical limiter), door-interlocked shutoff of heating & shaking