BrandLAUDA
OriginGermany
ModelIN 1590 XTW
Cooling MethodWater-Cooled
Temperature Range−90 °C to 220 °C
Refrigeration Capacity18.5 kW
Temperature Stability±0.05 °C
Circulation Pump Pressure3.1 bar
Circulation Flow Rate65 L/min
Bath Volume30.6 L
Operating ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelIN 550XTW
Cooling MethodWater-Cooled
Temperature Range−50 °C to 220 °C
Cooling Capacity5800 W
Temperature Stability±0.05 °C
Pump Pressure3.1 bar
Pump Flow Rate65 L/min
Reservoir Volume4.8–17.2 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
TypeSplit-System Circulating Chiller
Cooling MethodWater-Cooled
Temperature Range–10 to 35 °C
Refrigeration Capacity2.4 kW (at 10 °C outlet water temperature)
Temperature Stability±0.5 °C
Circulation Pump Pressure5.5 bar
Circulation Flow Rate68 L/min
Reservoir Volume12 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUC 8
Instrument TypeSplit-System
Cooling MethodWater-Cooled
Temperature Range–10 to 35 °C
Cooling Capacity10.2 kW (at 10 °C outlet water temperature)
Temperature Stability±0.5 °C
Circulation Pump Pressure5.6 bar
Circulation Flow Rate133 L/min
Reservoir Volume35 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUC 65
Cooling TypeWater-Cooled
Temperature Range–10 to 35 °C
Temperature Stability±0.5 °C
Refrigeration Capacity66.9 kW (at 10 °C outlet water temperature)
Circulating Pump Pressure6.9 bar
Circulating Pump Flow Rate367 L/min
Reservoir Volume210 L
Operation ModeContinuous
ConfigurationSplit-Type
ComplianceEU Ecodesign Directive (EU) 2016/2281, EN 60335-1, EN 60335-2-40
ConnectivityLAUDA Cloud integration, remote monitoring via PC or IR remote control
Protection RatingIP54
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelRP 245 EC
Instrument TypeIntegrated Circulating Chiller
Cooling MethodHybrid (Air- and Water-Cooled)
Temperature Range-45 to 200 °C
Cooling Capacity800 W at 20 °C
Temperature Stability±0.05 K
Circulating Pump Pressure0.68 bar
Circulating Pump Flow Rate22 L/min
Reservoir Volume2.4–4.4 L
Internal Fill VolumeMinimal (Optimized for Rapid Thermal Response)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelMC 350
Cooling MethodAir-Cooled
Temperature Range−10 to 40 °C
Cooling Capacity0.35 kW (at 20 °C with ethanol)
Temperature Stability±0.5 K
Pump Pressureup to 0.35 bar
Pump Flow Rate16 L/min
Reservoir Volume4.0–7.0 L
Power Supply230 V, 50 Hz
RefrigerantR-134a (0.095 kg)
Noise Level60 dB(A)
Dimensions (W×D×H)240 × 400 × 500 mm
Weight34 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelIN 150 XT
Cooling MethodAir-Cooled
Temperature Range-45 to 220 °C
Cooling Capacity1.5 kW (at 20 °C, Pump Level 8)
Temperature Stability±0.05 °C
Pump Pressure3.1 bar
Pump Flow Rate65 L/min
Reservoir Volume2.5–8.7 L
Operating ModeContinuous
Heater Power3.5 kW
Max. Power Consumption3.7 kW
Noise Level60 dB(A)
Net Weight103 kg
Dimensions (W×D×H)430 × 550 × 760 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelLOOP 250
Instrument TypeIntegrated Circulating Chiller
Cooling MethodAir-Cooled
Temperature Range4–80 °C
Refrigeration Capacity130 W (at 10 °C output)
Temperature Stability±0.1 °C
Circulation Pump Pressure0.8 bar
Circulation Flow Rate2.6 L/min
Bath Volume0.32 L
Operating ModeContinuous
Heating Power400 W
Pump Max Flow (at zero head)3 L/min
Dimensions (W×D×H)261 × 368 × 312 mm
Weight12 kg
Noise Level57 dB(A)
Power Supply100–240 V, 50/60 Hz
Protection ClassIP20
Fluid CompatibilityWater, Water/Glycol Mixtures (non-flammable)
InterfaceRS232
DisplayHigh-contrast OLED Graphical Screen
Control Interface3-button intuitive navigation
ConnectionQuick-release 1/4″ C-type fittings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelMC 1200
Cooling MethodAir-Cooled
Temperature Range–10 to +40 °C
Refrigeration Capacity1.20 kW at 20 °C (Ethanol)
Temperature Stability±0.5 °C
Pump PressureUp to 1.3 bar
Pump Flow Rate35 L/min
Reservoir Volume14.0 L
Operating ModeContinuous
Power Supply230 V, 50 Hz
RefrigerantR-134a (0.575 kg)
Dimensions (W × D × H)450 × 550 × 650 mm
Weight63 kg
Sound Pressure Level59 dB(A)
Max. Power Consumption1.15 kW
Max. Current6.5 A
Inlet/Outlet ThreadG 3/4"
Minimum Fill Volume7 L
Maximum Fill Volume14 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUC 24
Cooling TypeWater-Cooled
Temperature Range−10 to 35 °C
Temperature Stability±0.5 °C
Refrigeration Capacity24.3 kW @ 10 °C outlet
Circulating Pump Pressure5.8 bar
Flow Rate200 L/min
Reservoir Volume35 L
Duty CycleContinuous Operation
Enclosure RatingIP54
ConfigurationSplit System
ComplianceEU Ecodesign Directive (EU) 2016/2281, EN 60335-1, EN 60335-2-40
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUC 100
TypeSplit-System Circulating Chiller
Cooling MethodWater-Cooled
Temperature Control Range−10 to 35 °C
Refrigeration Capacity100.0 kW (at 10 °C outlet water temperature)
Temperature Stability±0.5 °C
Circulation Pump Pressure5.4 bar
Circulation Flow Rate300 L/min
Reservoir Volume125 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUC 4
TypeSplit-System Circulating Chiller
Cooling MethodWater-Cooled
Temperature Range–10 to 35 °C
Refrigeration Capacity4.8 kW (at 10 °C outlet water temperature)
Temperature Stability±0.5 °C
Circulating Pump Pressure5.5 bar
Circulating Pump Flow Rate68 L/min
Reservoir Volume12 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelLOOP 100
Instrument TypeIntegrated Circulating Chiller
Cooling MethodAir-Cooled
Temperature Range4–80 °C
Refrigeration Capacity60 W (at 10 °C output)
Temperature Stability±0.1 °C
Circulation Pump Pressure0.8 bar
Circulation Flow Rate2.6 L/min
Bath Volume0.28 L
Operating ModeContinuous
DisplayHigh-Contrast OLED Graphic Screen
InterfaceRS232
Power Supply100–240 V, 50/60 Hz
Max. Power Consumption0.24 kW
Dimensions (W×D×H)175 × 301 × 266 mm
Net Weight6.5 kg
Noise Level57 dB(A)
Fluid CompatibilityWater, Water/Ethylene Glycol Mixtures (Non-Flammable Only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUC 50
Instrument TypeSplit-System
Cooling MethodWater-Cooled
Temperature Control Range–10 to 35 °C
Refrigeration Capacity51.2 kW (at 10 °C outlet water temperature)
Temperature Stability±0.5 °C
Circulation Pump Pressure6.5 bar
Circulation Flow Rate250 L/min
Reservoir Volume210 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelUC 14
TypeSplit-System Circulating Chiller
Cooling MethodWater-Cooled
Temperature Range–10 to 35 °C
Temperature Stability±0.5 °C
Refrigeration Capacity15.8 kW (at 10 °C outlet water temperature)
Circulating Pump Pressure5.6 bar
Circulating Pump Flow Rate133 L/min
Reservoir Volume35 L
Duty CycleContinuous Operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelMC 250
Cooling MethodAir-Cooled
Temperature Range–10 to 40 °C
Refrigeration Capacity0.25 kW at 20 °C (ethanol)
Temperature Stability±0.5 K
Pump Max. Pressure0.35 bar
Pump Flow Rate16 L/min
Reservoir Volume2.0–4.0 L
Power Supply230 V, 50 Hz
RefrigerantR-134a (0.085 kg)
Dimensions (W×D×H)200 × 350 × 465 mm
Weight25 kg
Noise Level60 dB(A)
Max. Power Consumption0.23 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelIN 950 XTW
Cooling MethodWater-Cooled
Temperature Range-50 °C to 220 °C
Refrigeration Capacity9500 W
Temperature Stability±0.05 °C
Circulation Pump Pressure3.1 bar
Circulation Flow Rate65 L/min
Reservoir Volume4.8–17.2 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelIN 1850 XTW
Cooling MethodWater-Cooled
Temperature Range–50 °C to +220 °C
Refrigeration Capacity20,000 W
Temperature Stability±0.05 °C
Circulating Pump Pressure6.0 bar
Circulating Pump Flow Rate120 L/min
Bath Volume8.0–28.6 L
Operation ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelMC 600
Cooling MethodAir-Cooled
Temperature Range−10 to 40 °C
Refrigeration Capacity0.60 kW at 20 °C (Ethanol)
Temperature Stability±0.5 °C
Pump Pressureup to 1.3 bar
Pump Flow Rate35 L/min
Reservoir Volume4.0–8.0 L
Power Supply230 V, 50 Hz
RefrigerantR-134a (0.295 kg)
Dimensions (W×D×H)240 × 400 × 500 mm
Weight50 kg
Noise Level57 dB(A)
Max. Power Consumption0.7 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginUSA
ModelSemistat S 2400
Instrument TypeSplit-System
Cooling MethodWater-Cooled
Temperature Range-20 °C to 90 °C
Cooling Capacity2.45 kW
Temperature Stability±0.1 °C
Circulating Pump Pressure2.8 bar
Circulating Pump Flow Rate22 L/min
Reservoir Volume1.60 L
Operating ModeContinuous Water Cooling
Heating Power (Min)6 kW
Minimum Fill Volume1.25 L
Maximum Fill Volume1.6 L
Dimensions (W×D×H)116 mm × 300 mm × 560 mm
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelVC 2000W
Cooling MethodWater-Cooled
Temperature Range–20 °C to +80 °C
Refrigeration Capacity2.00 kW (at +20 °C output)
Temperature Stability±0.05 K
Circulating Pump Pressure0.9 bar
Circulating Pump Flow Rate28 L/min
Reservoir Volume15 L
Operating ModeContinuous
RefrigerantR-449A (GWP 1397)
Dimensions (W×D×H)450 × 550 × 650 mm
Weight58 kg
Power Supply230 V, 14 A, 3.3 kW max
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelIN 230 TW
Instrument TypeIntegrated Circulating Chiller
Cooling MethodWater-Cooled
Temperature Range–30 to 120 °C
Refrigeration Capacity2300 W
Temperature Stability±0.05 °C
Pump Pressure3.5 bar
Pump Flow Rate40 L/min
Reservoir Volume3.6–8.7 L
Operating ModeContinuous
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA
OriginGermany
ModelRP 250 EC
Cooling MethodHybrid (Air- and Water-Cooled)
Temperature Range-50 to 200 °C
Temperature Stability±0.05 K
Refrigeration Capacity1.5 kW
Pump Pressure0.68 bar
Pump Flow Rate22 L/min
Bath Volume2.4–4.4 L
Heating Power2.5 kW
Internal Fill VolumeMinimal (Optimized for Rapid Thermal Response)
RefrigerantR-452A (GWP 2140, compliant with EU Regulation (EU) No 517/2014)
ComplianceDIN 12876 Class I
Dimensions (W×D×H)300 × 430 × 675 mm
Weight48 kg