Life Science Instruments
Filter
Showing 2041–2070 of 2783 results
| Brand | Multi Channel Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MEA2100-mini |
| Instrument Type | Single-Well Format |
| Application Scope | In Vitro Electrophysiological Recording & Stimulation |
| Electrode Pitch | 200 µm |
| Electrode Diameter | 30 µm |
| Electrode Layout | 8×8 (60 active + 4 ground/ reference electrodes, or 120-channel variant) |
| Physical Dimensions | 186 × 80 × 12 mm |
| Amplifier Resolution | 24-bit |
| Max Sampling Rate per Channel | 50 kHz |
| Stimulator Modes | Current Source (±1 mA), Voltage Source (±10 V) |
| Signal Acquisition Units per MCS-IFB Interface Board | Up to 2 |
| Probes per Acquisition Unit | Up to 4 |
| Integrated On-Probe Electronics | Amplification, Stimulation, and ADC |
| Operating Environment | Standard CO₂ incubators (37 °C, 5% CO₂, humidified) |
| Brand | Multi Channel Systems |
|---|---|
| Origin | Germany |
| Manufacturer | Multi Channel Systems GmbH |
| Model | Roboocyte2 |
| Detection Principle | Two-Electrode Voltage Clamp (TEVC) |
| Instrument Type | Fully Automated High-Throughput Electrophysiology Platform |
| Cell Type | Xenopus laevis oocytes |
| Seal Resistance | >1 GΩ |
| Throughput Format | 96-well plate |
| Amplifier Architecture | Integrated High-Stability TEVC Amplifier |
| Liquid Handling Compatibility | RoboFlow or Gilson Pipetting Systems (Optional) |
| Brand | Muromachi |
|---|---|
| Origin | Imported (Japan) |
| Model | 51730M |
| Drive Type | Motorized (Stepper Motor Actuation) |
| Axes | X (Mediolateral), Y (Anteroposterior), Z (Dorsoventral) |
| Position Resolution | 10 µm per step |
| Control Interface | Capacitive Touchscreen Display |
| Manual Override | Integrated Mechanical Knobs |
| Joystick Mode | Analog Force-Feedback Translation |
| Zero-Point Memory | One-Touch Reference Reset |
| Compliance | ASTM F2118-22 (Stereotaxic Device Performance Criteria), ISO 13485–Certified Manufacturing Environment |
| Brand | Muromachi |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | MK-AL21D |
| Oxygen Flow Rate | 0.5–5 L/min |
| Vaporizer Capacity | 250 mL (max) |
| Adjustable Anesthetic Concentration Range | 0–5% (v/v) |
| Delivery Format | Benchtop, Key-Operated Fill System |
| Safety Compliance | Non-flammable anesthetic compatible (e.g., isoflurane, sevoflurane) |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Muscle SpikerBox |
| Type | DIY Electrophysiology Kit for EMG Recording |
| Compliance | CE, RoHS |
| Intended Use | Educational and Research-Level Surface Electromyography (sEMG) Signal Acquisition |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Muscle SpikerShield Bundle |
| Includes | Pre-assembled SpikerShield board, Arduino Uno (preloaded with EMG demo firmware), USB cable, 6× adhesive EMG electrodes, 1× adjustable wooden electrode stand, 1× bottle of conductive electrode gel, 1× orange recording electrode wire with alligator clips (2× red, 1× black), 1× brass rod-style electrodes for small-muscle recording |
| Compliance | CE, FCC, RoHS compliant |
| Software | Open-source Arduino IDE-compatible firmware, Python-based data visualization examples available via Backyard Brains GitHub repository |
| Target Platform | Arduino Uno R3 compatible |
| Input Signal Type | Bipolar surface electromyography (sEMG) |
| Sampling Resolution | 10-bit ADC (default), upgradable to 12-bit via firmware modification |
| Operating Voltage | 5 V DC (USB-powered) |
| Bandwidth | 10–450 Hz (analog signal path), configurable digital filtering in firmware |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoSystem 750 / 2000 / 4000 / 6000 |
| Price Range | USD $2,500 – $6,200 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | SC3/3, SC8/5, SC11/17, SC16/11, SC Millennium 20, SC20/20, SC33/26, SC36/32 |
| Price Range | USD $1,400 – $2,800 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVE XC |
| Price Range | USD $1,300 – $2,600 |
| Brand | Water Bear Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | mWB-X2 |
| Instrument Type | Protein Electrophoresis System |
| Sample Capacity | 6400 single cells per run |
| UV Source | Integrated long-life LED-based UV-C module (254 nm) |
| Gel Format | Photocrosslinkable hydrogel microarray chip (6000 micro-wells) |
| Electrophoresis Time | Adjustable, typical 5 min |
| Full Workflow Duration | 4–6 h |
| Detection Mode | On-chip fluorescent immunodetection |
| Data Output | Quantitative protein expression profiles with molecular weight estimation |
| Safety Features | Interlocked lid, real-time UV status monitoring, auto-shutdown, digital level calibration |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MYS-1 |
| Pricing | Upon Request |
| Brand | Dolomite Bio |
|---|---|
| Model | Nadia Innovate |
| Origin | United Kingdom |
| Instrument Type | Microfluidic Droplet-Based Single-Cell Capture Platform |
| Throughput | Up to 50,000 cells per run (max. 6,000 cells per sample) |
| Parallel Channels | 1–8 independent microfluidic lanes |
| Temperature Control Range | 4–40 °C (±0.5 °C stability) |
| Pressure Control | Digital pneumatic regulation (0–300 kPa, resolution 1 kPa) |
| Stirring Speed | 0–1,200 rpm (magnetic bead suspension optimization) |
| Real-Time Imaging | Integrated high-resolution CMOS camera (1280 × 960 px, 30 fps), calibrated for droplet size and monodispersity assessment |
| Compatibility | Mammalian cells (5–40 µm), nuclei, spheroids, and agarose-encapsulated samples |
| Software Interface | Nadia Instrument Control Suite v3.2 (Windows-based, audit-trail enabled) |
| Brand | NAI Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NAI-STV6 |
| Price | Upon Request |
| Construction Material | AISI 304 Stainless Steel |
| Filter Cup Configuration | 6 × Reusable 3B-Type Cups |
| Included Components | 6 × Filter Cups, 6 × 500 mL Borosilicate Glass Filtration Bottles, 6 × Sterile Bent Tubing Assemblies |
| Filter Membrane Compatibility | 0.45 µm or 0.22 µm, Ø50 mm |
| Max Vacuum Level | −0.08 MPa (−0.8 bar) |
| Air Flow Rate | ≥50 L/min at Rated Vacuum |
| Sterilization | Autoclavable (121 °C, 20–30 min, full manifold assembly) |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Digital PCR System |
| Model | NaicaEL |
| Compliance | CE-IVD, ISO 13485 certified manufacturing |
| Software | Crystal Miner™ v3.2 with FDA 21 CFR Part 11–compliant audit trail and electronic signature support |
| Detection Chemistry | TaqMan®-compatible hydrolysis probes & intercalating dyes |
| Partitioning Technology | Capillary-based microfluidic crystal formation (PRISM PCR™) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Blaze™ System |
| Volume Range | 1 L (Blaze™) / up to 10 L (Blaze+™) |
| System Architecture | Closed, single-use, GMP-ready process development platform |
| Core Technology | NxGen™ microfluidic mixing |
| Regulatory Alignment | Supports FDA 21 CFR Part 11–compliant data integrity, GLP/GMP process transfer readiness |
| Disposable Components | NxGen™ single-use chips (with/without inline dilution), sterile tubing kits for external vessel integration |
| Downstream Compatibility | Integrated TFF, sterile filtration, and fill-finish workflow support |
| Scalability Pathway | Direct CPP/CQA transfer from Blaze™ → Blaze+™ → NanoAssemblr™ Production System |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | NanoAssemblr™ Commercial Manufacturing System |
| Pricing | Upon Request |
| Flow Rate Range | 6–48 L/h (dependent on disposable flow path kit) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ GMP System |
| Flow Rate Range | 60–200 mL/min (3.6–12 L/h) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Spark™ Instrument |
| Sample Volume Range | 25–250 µL |
| Mixing Technology | NxGen™ Microfluidic Vortex Mixing |
| Sterility Design | BSC-Compatible, Aseptic Operation Ready |
| Chip Type | Single-Use, Gamma-Irradiated Cartridge |
| Scalability Pathway | Seamless Transition to NanoAssemblr™ Ignite™ and NxGen™ Production Platforms |
| Regulatory Context | Designed for GLP-compliant early-stage development, supports 21 CFR Part 11–ready software integration (optional) |
| Brand | NanoEnTek |
|---|---|
| Origin | South Korea |
| Model | ExTransfection |
| Type | Benchtop Microchannel Electroporator |
| Application Focus | High-Efficiency Nucleic Acid and RNP Delivery to Primary Cells, Stem Cells, and Immune Cells |
| Brand | NanoEntek |
|---|---|
| Origin | South Korea |
| Model | ExTransfection |
| Type | Fully Automated |
| Compliance | CE-IVD, ISO 13485–certified manufacturing environment |
| Application Focus | Primary cells, stem cells, CRISPR RNP delivery, GMP-compatible process development |
| Brand | NanoEX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NanoEX |
| Price Range | USD 70,000 – 140,000 |
| Dimensions | 537 × 260 × 363 mm |
| Weight | 10 kg |
| Throughput | Up to 168 mL/h |
| Sample Volume Range | 100 µL – 500 mL |
| Display | Integrated TFT touchscreen |
| Sterilization Compatibility | Autoclavable components |
| Membrane Compatibility | Interchangeable asymmetric nanopore membrane (ANM) cassettes |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Monolith X |
| Instrument Type | MicroScale Thermophoresis (MST) & Spectral Shift Analyzer |
| Channel Configuration | Single-Channel |
| Sample Capacity | ≤24 samples per run |
| Sample Volume per Assay | 4 µL |
| Analysis Time per K<sub>D</sub> | ≤10 min |
| Temperature Control Range | 20–40 °C with ±0.5 °C active thermal regulation |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Model | PR Panta |
| Temperature Control Range | 15 °C–95 °C (upgradeable to 110 °C with High-Temp Module) |
| Sample Volume | 10 μL |
| Sample Introduction | Capillary or capillary array |
| Dimensions | 35 cm (L) × 51 cm (H) × 52 cm (W) |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PR Panta Plus Robotic Autosample |
| Principle | Microfluidic Capillary Electrophoresis Coupled with Intrinsic Tryptophan Fluorescence Detection (not DLS — correction based on official NanoTemper documentation) |
| Temperature Control Range | 15 °C to 110 °C |
| Sample Volume | 10 µL per capillary |
| Sample Format | Disposable fused-silica capillaries (pre-filled or user-loaded) |
| 21 CFR Part 11 Compliance | Yes |
| Dimensions | 110 cm (W) × 188 cm (H) × 90 cm (D) |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Manufacturer | NanoTemper Technologies GmbH |
| Product Type | Imported Instrument |
| Model | Prometheus oDSF |
| Principle | Differential Scanning Fluorimetry (oDSF) |
| Sample Volume | 10 µL |
| Temperature Control Range | 15–110 °C |
| Sample Loading | Single capillary or capillary array |
| Dimensions | 35 cm (W) × 51 cm (H) × 52 cm (D) |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Manufacturer | NanoTemper Technologies GmbH |
| Product Type | Imported Instrument |
| Model | oDSF Prometheus Panta |
| Principle | Orthogonal Differential Scanning Fluorimetry (oDSF), Dynamic Light Scattering (DLS), Static Light Scattering (SLS), Backreflection Detection |
| Sample Volume | 10 µL |
| Temperature Control Range | 15–110 °C |
| Sample Format | Single capillary or capillary array |
| Dimensions | 35 cm (W) × 51 cm (H) × 52 cm (D) |
| Brand | NanoTemper |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Panta+Robotic Autosampler |
| Measurement Principle | Orthogonal Differential Scanning Fluorescence (oDSF) |
| Sample Volume | 10 µL |
| Temperature Control Range | 15–110 °C |
| Sample Capacity | 64 sample groups per run (1536 samples total before reload |
| Sample Loading Method | Capillary-based loading |
| Dimensions | 110 cm (W) × 188 cm (H) × 90 cm (D) |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | EG-45 |
| Movement Range (X-Y) | 0.47 mm |
| Motor Speed | 150–2,100 rpm |
| Power Supply | AC 100–240 V (±5%), 50/60 Hz |
| Power Consumption | ~10 W |
| Dimensions | 185 × 165 × 310 mm |
| Weight | 2.4 kg |
| Compatible Capillary O.D. | 1.0–1.5 mm |
| Vertical Adjustment Range | 0.47 mm |
| Included Accessories | Pipette Holder, Vertical Grinding Adapter, Diamond Grinding Wheel, Cleaning Brush, Hex Key, Power Cord |
| Brand | NAYO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | A8 Series – Blood Aliquoting Solution |
| Sample Type | Whole Blood, Serum, Plasma |
| Pipetting Range | 1–1000 µL |
| Pipetting Accuracy | ≤4% CV at 5 µL, ≤1% CV at 200 µL |
| Throughput Flexibility | Configurable for low- to high-throughput workflows (1–96 samples per run) |
| Arm Configuration | Dual robotic arms (cap-opening + pipetting), up to 4 independent pipetting channels |
| Tube Compatibility | Standard EDTA/K2EDTA/NaCitrate blood collection tubes (vacutainers), oropharyngeal swab tubes, urine containers, 1.5–15 mL centrifuge tubes, 0.5–2.0 mL cryovials |
| Optional Modules | Integrated tube decapping/capping unit, nucleic acid extraction module, temperature-controlled shaking platform (4–40 °C), magnetic bead separation rack |