| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 735-1 |
| Input Channels | 1 × Pt100 + 2 × Thermocouple (Type K, J, T, N, S, R, B, E, L, U) |
| System Accuracy (with optional high-precision Pt100 probe) | ±0.05 °C |
| Resolution | 0.001 °C |
| Display | Dual-line LCD with simultaneous 3-channel readout |
| Alarm | Audible limit alarm |
| Data Logging | Internal storage for min/max/avg/ΔT |
| Print Output | Optional infrared printer interface with programmable cycle (1 min – 24 h) |
| Protection Rating | IP65 |
| Calibration | Full-scale system adjustment capability |
| Compliance | Designed to support GLP/GMP traceability workflows |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7450 |
| AC Voltage Range | 12–1000 V |
| Operating Temperature | −10 to +50 °C |
| Storage Temperature | −15 to +60 °C |
| Relative Humidity | 0–80 % RH |
| Weight | 63 g |
| Dimensions | 155 × 25 × 23 mm |
| Protection Rating | IP67 |
| Safety Category | CAT IV 600 V / CAT III 1000 V |
| Compliance | EN 61010-1, EN 61326-1 |
| Battery | 2 × AAA |
| Integrated LED Illumination | Yes |
| Alarm Type | Visual (LED) and Audible |
| Sensitivity Levels | 2-stage (Phase Detection / Voltage Presence Indication) |
| Interference Rejection | Built-in High-Frequency Noise Filter |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0516 1901 |
| Dimensions (L×W×H) | 340 × 265 × 60 mm |
| Weight | 1130 g |
| Housing Material | High-strength plastic |
| Interface | USB Type-A |
| Capacity | Simultaneous programming and readout of up to 8 compatible testo data loggers |
| Software | Not included — requires separate purchase of testo ComSoft software suite |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2166 |
| Interface Type | 4–20 mA / 0–10 V analog input |
| Compatible Host Device | testo 150 TUC4 Data Logger |
| System Integration | testo Saveris Pharma Environmental Monitoring Platform |
| Communication | WLAN, LAN, or UltraRange radio (via testo 150 TUC4) |
| Input Signal Support | Standard industrial current/voltage transmitters (e.g., differential pressure, CO₂, airflow, liquid level) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0646 007 |
| Package | 10 labels per pad |
| Activation Temperatures | +88 °C, +93 °C, +99 °C, +104 °C, +110 °C |
| Response Time | ≤3 s at activation threshold |
| Compliance | CE-marked, RoHS-compliant |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | Saveris 2-T2 |
| Measurement Range | –50 to +150 °C |
| Accuracy | ±0.5 °C |
| Resolution | ±0.1 °C |
| Data Storage Capacity | 10,000 readings |
| Battery Life | Up to 12 months (typical, at +25 °C, 15-min interval) |
| Operating Temperature | –30 to +50 °C |
| IP Rating | IP65 |
| Dimensions | 95 × 75 × 30.5 mm |
| Weight | 240 g |
| Power Supply | 4 × AA batteries (Energizer L91 recommended below –10 °C) |
| Compliance | EN 12830 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 9310 |
| Connectivity | Ethernet + UltraRange proprietary RF (868 MHz, encrypted) |
| Max. Connected Devices | 40 testo 150 data loggers |
| System Integration | testo Saveris Pharma environmental monitoring platform |
| Power Supply & Communication Modules | Not included |
| Included | Configuration cable |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9320 |
| Application | Wireless connectivity module for testo 150 data logger system |
| Communication Protocol | IEEE 802.11 b/g/n (2.4 GHz) |
| Security | WPA2-PSK encryption |
| Operating Temperature | -20 °C to +60 °C |
| IP Rating | IP20 |
| Compliance | CE, RoHS, FCC Part 15 Subpart B |
| [Brand | ACT/Tetras |
|---|---|
| Origin | USA |
| Model | Tetras 106-Channel Peptide Synthesizer |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale per Reactor | 30–1000 µmol or 0.01–3 g resin |
| Max Reactor Count | ≤106 |
| Reactor Volumes | 6 mL, 25 mL, 40 mL, 60 mL |
| Syringe Pump Accuracy | <1% |
| Synthesis Purity | ≥99.5% |
| Flow Rate | 0.25–1 mL/s] |
| Brand | Tianhe (Shandong Tianhe Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TH-YB416 |
| Price | USD 6,700 (approx. based on ¥48,000 at 1 USD ≈ ¥7.15) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Max Heating/Cooling Rate | ≥2 °C/s |
| Temperature Uniformity | ≤±0.2 °C |
| Temperature Accuracy | ≤±0.1 °C |
| Excitation Wavelength Range | 400–700 nm |
| Detection Channels | 1 channel (FAM/SYBR Green I) standard |
| Optical Detection | Imported photodetector array |
| Thermal Module | High-performance Peltier (Marlow) with PT1000 sensor and resistive edge compensation |
| Thermal Gradient | None |
| Real-time Data Acquisition | 3-second full-plate read |
| Display | 7-inch HD capacitive touchscreen |
| Noise Level | <45 dB |
| Dimensions (W×L×H) | 290 × 308 × 130 mm |
| Net Weight | ~3 kg |
| Brand | BioLife Solutions |
|---|---|
| Origin | USA |
| Model | CFT2 |
| Type | Fully Automated |
| Compliance | CE (EMC & Safety), EN 61010-1, RoHS, WEEE |
| Transport Compatibility | Compatible with ThawSTAR® AST-602 Cryo-Transport Box (-70 °C stable) |
| Operation | Dry, water-free thawing |
| Control | STAR™ Intelligent Temperature Sensing Technology |
| Sample Ejection | Motorized auto-eject with audible and visual completion alert |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BHK-C30 |
| Power | 800 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Drying Tube Length | 170 mm (standard), customizable |
| Number of Drying Ports | 30 |
| Operating Temperature Range | 40–120 °C |
| Temperature Stability | ±2 °C |
| Outer Dimensions | Ø400 × 620 mm |
| Net Weight | 30 kg |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLZZ-50 |
| Vacuum Level | −0.098 MPa (98 kPa) |
| Operating Pressure Range | −0.1 MPa to 0.0 MPa |
| Temperature Range | −80 °C to +200 °C |
| Construction Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Frame Material | Powder-Coated Q235 Steel + Anodized 6061-F Aluminum |
| Mobility | Locking Casters with Brake |
| Capacity | 50 L |
| Compliance | Designed for GLP-compliant laboratory filtration workflows |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CZLL-20 |
| Pricing | Available Upon Request |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DLSB-5/20A |
| Price | Upon Request |
| Compressor | Embraco hermetic piston compressor |
| Condenser | Air-cooled finned-tube type with oxygen-free copper spiral tubing |
| Evaporator | 304 stainless steel coil-in-tank design |
| Reservoir Material | SUS304 stainless steel |
| Controller | LCD interface with Pt100 sensor, ±0.1 °C display resolution, CE certified |
| Communication | RS485 interface, MODBUS RTU protocol |
| Electrical Components | Schneider brand |
| Refrigerant | R404A (CFC-free, environmentally compliant) |
| Safety Protections | Delayed start, overcurrent, overheat, grounding, high-pressure protection |
| Ambient Operating Range | 5–35 °C, ≤70% RH |
| Power Supply | 220–240 V~, 50 Hz |
| Temperature Range | –20 °C to +25 °C (ambient-dependent upper limit) |
| Stability | ±2 °C |
| Rated Power | 715 W |
| Cooling Capacity | 680 W @ 10 °C, 600 W @ 0 °C, 520 W @ –10 °C, 360 W @ –20 °C |
| Reservoir Volume | 5 L |
| Pump Flow Rate | 20 L/min |
| Max. Discharge Pressure | 0.4 bar |
| Ingress Protection | IP20 |
| Pollution Degree | Class II |
| Fluid Connection | R1/2″ BSP male thread |
| Tubing | Silicone rubber hose (Φ13×Φ9 mm) |
| Dimensions (W×D×H) | 335×473×684 mm |
| Net Weight | 42 kg |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LT-50-80 |
| Cooling Capacity at −80 °C | 1000 W |
| Temperature Range | −80 °C to −40 °C |
| Temperature Stability | ±2 °C |
| Power Supply | 3~ 380 V, 50 Hz |
| Total Power Consumption | 9.8 kW |
| Refrigerant | R404A/R23 |
| Pump Flow Rate | 30 L/min |
| Max. Pressure | 1.0 bar |
| Reservoir Volume | 10 L |
| Dimensions (L×W×H) | ≈1200×710×1280 mm |
| Weight | 350 kg |
| Evaporator | Brazed Plate Heat Exchanger |
| Pump Type | Cryogenic-Optimized Magnetic Drive Circulating Pump |
| Construction | SUS304 Stainless Steel Reservoir & Tubing |
| Cabinet Material | SPCC Electrostatic Powder-Coated Steel |
| Cooling Method | Air-Cooled |
| Safety Protections | High/Low Pressure, Oil Pressure, Leakage, Overload, Overheat |
| Refrigerant Compliance | GB/T 7778–2008, EU F-Gas Regulation Compliant |
| Brand | Thermo Fisher |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 3500 Dx / 3500xL Dx |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Throughput | 1104 samples/day |
| Read Length Range | 30–1000 bp |
| Detection Accuracy | 99.99% |
| Detection Reproducibility | 90% |
| Run Time | 1000 reads per 120 min |
| Data Format | Capillary Electrophoresis-Based Sequencing |
| Software | Data Collection Software v3, Sequencing Analysis v6, KB Basecaller v1.4.1, Variant Reporter™, SeqScape®, GeneMapper®, GeneMapper ID-x®, MicroSEQ ID® |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Model | Gemini AS |
| Automation Level | Fully Automatic |
| Instrument Type | Rotary Stainer |
| Heating Stations | 5 independent |
| Reagent Positions | 26 or 31 |
| Water Stations | 4 |
| Slide Capacity per Rack | Standard (compatible with standard histology slide racks) |
| Emergency STAT Processing | Yes, priority queueing for urgent cases (e.g., Mohs surgery) |
| Backup Power | 40-minute battery runtime |
| Compliance Features | Integrated fume management, anti-siphon valves, flow regulators, locked slide baskets, password-protected protocol editing |
| Software | Scheduler™ with editable protocols, preloaded Thermo Scientific Signature™ stain protocols |
| Connectivity | USB for protocol/log export |
| Footprint | Compact dual-level design with integrated touchscreen and power supply |
| Safety | Activated carbon filtration or vent adapter kit optional |
| Door Configuration | 4 configurable access doors |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CTS Xenon |
| High Voltage Range | 2500 V |
| Low Voltage Range | 500 V |
| Pulse Count | 1–10 |
| Pulse Duration | 1–30 ms |
| Output Waveform | Square Wave |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Model | Linistat |
| Automation Level | Semi-Automatic |
| Instrument Type | Non-Rotary Linear Stainer |
| Staining Stations | 14 (20 sec/station) |
| Throughput | ≤5 min per batch (13 slides) |
| Slide Capacity | 13-slide collection tank |
| Water Rinse Tank | Position-adjustable |
| Footprint | Compact, designed for placement atop cryostats |
| Compatible Stain | Optimized for Hematoxylin-Eosin (H&E) staining of frozen sections |
| Compatible Reagents | Thermo Scientific Cryochrome™ embedding media and color-coded slide holders |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Model | PrintMate AS |
| Capacity Options | 150 (2-slot), 450 (6-slot), 900 (12-slot) |
| Cassette Load per Slot | 75 |
| Input Mechanism | Rotary Magazine Feeding |
| Compatible Cassette Type | Standard 45°-angled plastic tissue cassettes |
| Printing Technology | Thermal Foil Transfer with High-Durability Ribbons |
| Barcode/QR Support | Code 128, Code 39, Data Matrix, QR Code |
| Character Set | Unicode-compliant (Latin, Cyrillic, Greek, CJK Unified Ideographs), Windows TrueType Fonts |
| Interface | HL7, ASTM LIS/HIS Integration |
| Compliance | ISO 15189, CLIA, CAP, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Optional Module | Smart Sorting Drawer System (100-cassette simultaneous collection) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | United Kingdom |
| Model | STP 120 |
| Reagent Stations | 10 (9 when 3 paraffin stations configured) |
| Paraffin Stations | 2 (optional 3rd) |
| Station Volume | 1.8 L each |
| Voltage | 100–120 V / 220–240 V AC (±10%), 50–60 Hz |
| Temperature Range | 50–70 °C |
| Overtemperature Cutoff | 75 °C (±4 °C) |
| Cassette Basket Capacity | 120 cassettes (1 basket standard, optional 2nd) |
| Programmable Protocols | 10 stored methods |
| Dwell Time per Station | 1 sec – 99 hr 59 min |
| Rotation-Based Agitation | Enabled |
| Vertical Agitation | Optional |
| Centrifugal Drying | Optional |
| Delayed Start | Supported |
| Safety | Overheat protection with automatic power cutoff and integrated backup power circuit |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Scientific™ Forma™ |
| Effective Capacity | 368 L |
| Interior Dimensions (mm) | 1308 × 584 × 490 |
| Exterior Dimensions (mm) | 1979 × 846 × 836 |
| Power Supply | 230 V / 50 Hz |
| Rated Power | 400 W |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | IGS180 |
| Temperature Range | +5 to 75 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C |
| Chamber Volume | 180 L |
| Interior Material | Corrosion-Resistant Stainless Steel (EN 1.4016) |
| Display | Large Vacuum Fluorescent Display (VFD) |
| Control Interface | Intuitive Touch-Sensitive Keypad |
| Standard Shelving | 2 Adjustable Shelves (Up to 19 Supported) |
| Max Shelf Load | 55 kg |
| Power Supply | 230 V / 50 Hz |
| Rated Power | 710 W |
| Net Weight | 65 kg |
| External Dimensions (W×H×D) | 640 × 920 × 738 mm |
| Internal Dimensions (W×H×D) | 464 × 708 × 589 mm |
| Footprint Area | 0.47 m² |
| Minimum Rear Clearance | 80 mm |
| Castor-Inclusive Height | 920 mm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | IMC18 |
| Temperature Range | 17–40 °C |
| Temperature Uniformity | ±0.2 °C (at 37 °C) |
| Chamber Volume | 18 L |
| Chamber Dimensions (W×H×D) | 180 × 310 × 290 mm |
| Footprint Area | 0.12 m² |
| Standard Shelving | 2 adjustable stainless-steel shelves (max. 3) |
| Max. Load per Shelf | 2 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Rated Power | 45 W |
| Net Weight | 7.2 kg |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | KingFisher PlasmidPro |
| Pricing | Available upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Multiskan™ FC |
| Functionality | Absorbance-only microplate reader |
| Automation Level | Fully automated |
| Assay Modes | Endpoint and kinetic |
| Curve Fitting Options | Linear, 4-parameter logistic (4PL), 5-parameter logistic (5PL), quadratic, cubic, log-log, semi-log |
| Detector Type | Photodiode-based UV-Vis spectrophotometer |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–6.0 OD |
| Linearity | ±2% deviation from theoretical value within 0–4.0 Abs (96-well plate, standard mode) |
| Read Speed | 6 seconds per 96-well plate (fast mode) |
| Precision | CV ≤ 0.2% (0–3.0 Abs, standard mode) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | 6242 / 6240 |
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Nucleic Acid Hybridization Oven |
| Temperature Range | 35–85°C |
| Temperature Uniformity | ±0.25°C (within chamber) |
| Rotational Speed (rotating wheel) | 5–15 rpm |
| Horizontal Oscillation Speed (platform) | 4–10 rpm |
| Chamber Internal Dimensions (L × W × H) | 24 × 35 × 61.25 cm |
| Platform Size (L × W) | 25 × 45 cm |
| External Dimensions (L × W × H) | 38 × 42.5 × 108.75 cm |
| Power Supply | 220 V, 250 W |
| Max Load (horizontal platform) | 1 kg |
| Capacity | 10 × 35 mm ID × 250 mm L hybridization bottles |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Wellwash Versa |
| Pricing | Upon Request |
| Wash Fluid Channels | Up to 3 |
| Bottle Configuration | Two 2-L wash bottles, one 2-L rinse bottle, one 4-L waste bottle |
| Wash Heads | 1×8, 1×12, 2×8, 2×12, 1×16, plus dedicated 1×8 and 2×8 cell wash heads |
| Compatible Plate Formats | 96-well and 384-well microplates |
| Wash Volume Range | 50–1000 µL (96-well), 20–300 µL (384-well) |
| Pre-wash Volume | 5–100 mL |
| Rinse Volume | 5–100 mL |
| Dispense Volume | 50–400 µL (96-well), 20–120 µL (384-well) |
| Residual Liquid Volume | <1.5 µL per well |
| Data Interface | USB port, RS-232C for automation integration |
| Dimensions (H×W×D) | 345 × 385 × 240 mm (13.6 × 15.2 × 9.4 in) |
| Weight | 9 kg (20 lbs) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Variants | SHKE4000-1CE / SHKE4000-6CE / SHKE4000-8CE |
| Instrument Type | Orbital Shaker |
| Platform Size | 45.7 × 45.7 cm (18 × 18 in) |
| Orbit Diameter | 19 mm (0.75 in) |
| Speed Range (Analog) | 40–400 rpm |
| Speed Range (Digital) | 15–500 rpm |
| Temperature Control Range | Ambient to 60°C (Heating Only) or 4–60°C (Refrigerated Models) |
| Temp Accuracy | ±0.1°C at 37°C |
| Temp Uniformity | ±0.5°C across platform |
| Safety Features | Lid Interlock, Over-Temp Protection, Imbalance Detection, Speed Deviation Alert (±10%), Soft Start/Stop |
| Motor Type | Brushless DC Motor |
| Dimensions (W×D×H) | 81.3 × 57.2 × 55.9 cm (32 × 22.5 × 22 in) for standard models |
| Weight | 75.8 kg (167 lb) |