| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic |
| Model No. | 30564095 |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Motorized |
| Channel Count | Single |
| Volume Range | 10–1000 µL |
| Maximum Capacity | 10 mL |
| Accuracy Tolerance | ±3–10% |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pre-sterilized, Recyclable Tip Rack System |
| Material Composition | Primarily PETE (Polyethylene Terephthalate) |
| Sterilization | Gamma-irradiated, ISO 11137 compliant |
| Environmental Certification | 100% recyclable per ISO 14021 |
| Packaging Efficiency | 50% less plastic vs. conventional tip racks |
| Compressibility | High — post-use volume reduction >60% in waste stream |
| Regulatory Compliance | Meets EU Directive 2002/96/EC (WEEE) and EN 13432 for recoverability |
| Brand | Micronit |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | LOC-1 |
| Price Range | USD 6,800 – 13,600 (est.) |
| Chip Interface | Standard Glass-Based Microfluidic Cartridge |
| Fluidic Control Compatibility | Pressure-Driven (e.g., MFCS) or Syringe Pump-Based |
| Optical Transparency | Full Visible to NIR Transmission |
| Material | Borosilicate Glass (HF-etched, Cleanroom-Fabricated) |
| Surface Treatments | Native Hydrophilic or Fluoropolymer-Coated Hydrophobic |
| Chip Architectures | T-Junction and Flow-Focusing (Cross-Junction) Configurations |
| Customization Support | CAD-Based Design-to-Manufacturing Workflow (Lead Time: 4–5 Weeks) |
| Brand | MIKROMEISTER |
|---|---|
| Origin | Germany |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.25–50 mL |
| Minimum Increment | 0.25 mL |
| Accuracy | ±0.5% (99.5% repeatability) |
| Construction Materials | PTFE, PFA, borosilicate glass, platinum-plated components |
| Sterilization | Autoclavable at 121°C |
| Compliance | Designed for GLP/GMP environments |
| Brand | CHINYEE |
|---|---|
| Origin | Germany |
| Model | MDP |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.2–100 mL |
| Minimum Increment | 0.005 mL |
| Accuracy | ±1% (full scale) |
| Precision | ≤0.5% RSD |
| Material Compatibility | HF, H₂SO₄-resistant PTFE/PP/PFA components |
| Max Operating Temperature | 120 °C |
| Single-Dispense Range | 5–1500 µL |
| Compliance | ISO 8655-3, DIN EN ISO 17025 (calibration traceable to PTB) |
| Brand | Miragen |
|---|---|
| Origin | USA |
| Type | 8-Channel Electronic Pipette |
| Automation Level | Motorized |
| Volume Range | 0.2–300 µL |
| Maximum Single-Channel Capacity | 300 µL |
| Accuracy | 0.4–0.8% |
| Precision (CV) | ≤0.15–0.25% |
| Tip Compatibility | Standard conical polypropylene tips (10–300 µL range) |
| Power | Removable rechargeable Li-ion battery |
| Charging | Dock-based |
| Operating Interface | Rotary thumb wheel + tactile keypad |
| Modes | Pipette, Manual, Aspirate, Stepper |
| Compliance | Designed to meet ISO 8655-2:2022 requirements for piston-operated volumetric apparatus |
| Brand | Miragen |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MiraPette E |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Electronic (Motor-Driven) |
| Channels | 1 |
| Volume Range | 0.2–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | 0.4–1.0% |
| Precision (CV) | 0.15–0.4% |
| Increment Resolution | 0.1 µL to 0.1 mL (model-dependent) |
| Power | Removable Rechargeable Battery |
| Charging | Dock-Based |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MX602 |
| Diluent MFC Range | 0–5 L/min (optional: 10 L/min, 20 L/min) |
| Source Gas MFC Range | 0–100 mL/min (optional: 50 mL/min, 1 L/min) |
| Accuracy | ±1.0% S.P. |
| Dilution Ratio | 3.5:1 to 950:1 (standard) |
| up to 10,000 | 1 (optional) |
| Flow Repeatability | <0.5% |
| Gas Blending Uncertainty | <1% |
| Warm-up Time | 30 min |
| Auto-zero Function | Yes |
| Inlet Fittings | 1/8" for source gas, 1/4" for diluent |
| Outlet Fittings | 1/8" standard gas outlet, 1/4" bypass outlet |
| Display | Touch-enabled LCD interface |
| Power Supply | 220 VAC |
| Operating Environment | 5–45 °C |
| Dimensions (W×D×H) | 427 × 380 × 185 mm |
| Weight | ~5 kg |
| Optional Inertized Flow Path | Silanized tubing, fittings, and internal wetted surfaces for reactive species (e.g., H₂S, mercaptans, aldehydes) |
| Brand | Nichipet (Nichiryo) |
|---|---|
| Origin | Japan |
| Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range | 0.5–10 µL, 10–100 µL, 20–200 µL, 30–300 µL |
| Maximum Capacity | 300 µL |
| Accuracy | ±0.01 µL (at lowest range) |
| Compliance | ISO 8655-2:2022, GLP-ready design |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Product Line | Nichipet Air |
| Pipette Type | Air-displacement Manual Pipette |
| Channel Configurations | Single-channel, 8-channel, 12-channel |
| Volume Range | 0.1–2 µL (ultra-low volume models) |
| Accuracy | ±3% |
| Weight Optimization | Reduced plunger force, minimized body mass, and low tip ejection force |
| Color Coding | 8 distinct pastel (macaron-style) color variants for single-channel models |
| Compliance | Designed in accordance with ISO 8655-2:2022 (Piston-operated volumetric apparatus — Part 2: Piston pipettes) and compatible with GLP/GMP workflows requiring traceable liquid handling |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet Air |
| Volume Range Options | 0.1–2 µL (Gray), 0.5–10 µL (Pink), 2–20 µL (Beige), 10–100 µL (Orange), 20–200 µL (Yellow), 100–1000 µL (Blue), 500–5000 µL (Green), 1000–10000 µL (White) |
| Increment Resolution | 0.002–10 µL (model-dependent) |
| Operating Principle | Air-displacement positive displacement hybrid mechanism with low-force plunger actuation |
| Brand | Nichipet (Nichiryo) |
|---|---|
| Origin | Japan |
| Type | Air-displacement single-channel manual pipette |
| Channels | 1 |
| Volume Range | 0.1–2 µL, 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 100–1000 µL, 500–5000 µL, 1000–10000 µL |
| Maximum Capacity | 10 mL |
| Accuracy (at lowest range) | ±0.002 µL (for 0.1–2 µL setting) |
| Weight | 70 g |
| Actuation Force Reduction | Up to 70% vs. conventional models |
| Calibration | Tool-free adjustment via volume dial and locking fixture |
| Color-Coded Volume Ranges | Yes |
| Compliance | Designed for ISO 8655-compliant operation and GLP/GMP laboratory workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet FII & VII |
| Type | Manual Single-Channel Adjustable-Volume Pipette |
| Volume Range | 10–1000 µL |
| Accuracy | ±0.5% to ±1.2% (varies by volume) |
| Coefficient of Variation (CV) | ≤0.2% to ≤0.6% (volume-dependent) |
| Tip Compatibility | BMT2-series and F-series sterile filtered tips (e.g., BMT2-SG, FSGRB, BMT2-LE, FLERB) |
| Operating Principle | Air-displacement positive displacement (FII: fixed-volume |
| VII | triple presettable volumes) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | ACCUPENSER JR |
| Instrument Type | Manual Adjustable Bottle-top Dispenser |
| Automation Level | Manual |
| Volume Range Options | 0.2–10 mL (AJ-1), 0.4–20 mL (AJ-2), 1–50 mL (AJ-5), 2–100 mL (AJ-10) |
| Minimum Increment | 0.05 mL (AJ-1), 0.1 mL (AJ-2 & AJ-5), 0.25 mL (AJ-10) |
| Coefficient of Variation (CV) | ≤0.1% |
| Bottle Compatibility | Standard 500 mL and 1 L reagent bottles (neck dimensions identical) |
| Bottle Dimensions (W × H, mm) | 75 × 210 (165), 100 × 210 (165), 146 × 210 (165) — values in parentheses indicate collapsed height when vernier head is folded |
| Materials in Contact with Liquids | Chemically resistant polymers |
| Sterilization | Autoclavable at 121°C for 20 minutes |
| Compliance | Designed to support GLP-compliant workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Custom-Made Pipettes |
| Instrument Type | Single-Channel Manual Pipette |
| Automation Level | Manual |
| Channel Count | Single |
| Volume Range | Custom-Defined (Typically 0.1–10,000 µL) |
| Accuracy & Precision | Compliant with ISO 8655 (per customer-specified calibration range) |
| Regulatory Compliance | Designed to support GLP/GMP workflows and FDA 21 CFR Part 11–aligned documentation protocols |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.2–10 mL |
| Minimum Graduation | 0.05 mL |
| Accuracy | ±0.1% of full scale |
| Maximum Permissible Error | ±0.5% of set volume |
| Pressure Resistance | Up to 6 bar |
| Temperature Resistance | Up to 120 °C |
| Material Compatibility | Chemically resistant PTFE, FFKM, and glass-reinforced PPS components |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET Mini |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 100–2000 µL (selectable in 5 fixed increments: 100, 250, 500, 1000, 2000 µL) |
| Accuracy | ±0.4% |
| Precision (CV) | ≤2% |
| Construction | Chemically resistant PTFE, ETFE, and PP components |
| Compatibility | Fits GL45 standard bottle threads |
| Certifications | ISO 8655-3 compliant for piston-type dispensers |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL2100DG |
| Type | Manual Multi-Channel Continuous Dispenser |
| Dispensing Range Options | 0.2–1.0 mL (00-21DG-1), 0.4–2.0 mL (00-21DG-2), 1.0–5.0 mL (00-21DG-5), 2.0–10.0 mL (00-21DG-10) |
| Minimum Increment | 0.01–0.10 mL depending on model |
| Display Resolution | 0.01 mL (DG-1/DG-2), 0.02 mL (DG-5), 0.10 mL (DG-10) |
| Fluid Contact Materials | PTFE, Tygon® tubing, polypropylene, Pyrex® glass, ceramic, platinum-iridium alloy |
| Housing | Impact-resistant polymer shell protecting internal glass and piston components |
| Ergonomics | Single-hand operation, lightweight design (<300 g) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL3100 |
| Pipette Type | Manual Multi-Channel Pipette |
| Volume Range Options | 0.2–1.0 mL, 0.4–2.0 mL, 1.0–5.0 mL, 2.0–10.0 mL |
| Minimum Increment | 0.1 mL (for 0.2–1.0 & 0.4–2.0 mL ranges), 0.5 mL (for 1.0–5.0 & 2.0–10.0 mL ranges) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Tip Compatibility | Nichiryo Standard Clear Tips (00-MPT-1, 00-MPT-2, 00-BMT2-X, 00-BMT2-Z) |
| Piston Material | PTFE-Coated Stainless Steel |
| Tip Packaging | 1000 or 2000 per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL5100 |
| Pipette Type | Single-Channel Manual Pipette |
| Adjustable Volume Range | 15–25 mL and 30–50 mL (via interchangeable volume adjustment tubes) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Compatible Tip Type | Nichiryo TL50 Series (e.g., 00-51TL50) |
| Tip Packaging | 50 pcs per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8100 |
| Type | Motorized Multi-Step Electronic Dispenser |
| Sample Volume Range | 1 µL – 5 mL (configurable via 7 interchangeable syringe barrels) |
| Accuracy | ±0.8% to ±2.5% (volume-dependent) |
| Precision (CV) | ≤0.3% to ≤4.0% (volume-dependent) |
| Max. Dispensing Cycles per Fill | 10–58 (barrel-dependent) |
| Sterilization | Autoclavable at 121 °C for 20 min (all barrels except 3.0 mL and 60 mL) |
| Syringe Tip Length | 50 mm |
| Materials | PP (standard), PE (N3 and Z barrels) |
| Drive Mechanism | Pulse-driven positive displacement |
| Compliance | Designed for GLP-compliant liquid handling workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8800 |
| Instrument Type | Multi-Channel Manual Continuous Dispenser |
| Number of Channels | 8 |
| Operating Range | 10–100 µL (6 preset volumes: 10, 20, 25, 40, 50, 100 µL) |
| Accuracy | ±2.0% (at specified volumes) |
| Coefficient of Variation (CV) | ≤1.2% |
| Syringe Options | A (520 µL), B (1300 µL) |
| Max. Sequential Dispensing Cycles | 50 (at 10 µL), 25 (at 20/25 µL), 12 (at 40/50/100 µL) |
| Dimensions (with syringes installed) | 285 × 82 × 23 mm |
| Sterilization Compatibility | Autoclavable at 121°C for 20 min |
| Actuation | Manual lever-driven continuous dispensing |
| Brand | AS ONE (Nichiryo) |
|---|---|
| Origin | Japan |
| Manufacturer | Nichiryo Co., Ltd. |
| Model | 00-NSTP (equivalent to AS ONE catalog no. 2-5001-01) |
| Dispensing Range | 1–5000 µL |
| Dispense Increment | 1 µL |
| Drive Type | Motorized (Electric) |
| Channel Configuration | Single-Channel |
| Compliance | CE-marked, ISO 8655-compliant design principles |
| Calibration | Factory-calibrated per ISO 8655-6 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NPLO2 |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.5 µL – 50 mL (via interchangeable syringe barrels) |
| Accuracy | ±0.3% to ±5% (volume-dependent) |
| Precision (CV) | <0.2% to <8.0% (volume-dependent) |
| Sterilizable Options | Yes (selected syringe barrels) |
| Compatible Tips | BMT-UT tips (NS-V), NS-ASP adapters (NS-Y/Z), Eppendorf 4780-compatible syringes |
| Syringe Material | Polypropylene (barrel), Polyethylene (plunger) |
| Max Sequential Dispensing Cycles | 48 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet ECO |
| Pipette Type | Single-channel Manual Pipette |
| Volume Range | 20 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±3.0% to ±6.0% |
| Precision (CV) | ≤3.0% to ≤6.0% |
| Tip Compatibility | Nichiryo Glass Tips (S, L, X, Z series) |
| Operating Principle | Air-displacement with ceramic piston and PTFE-coated tip cone |
| Sealing | Dual O-ring tip ejection mechanism |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | EX II MULTI |
| Pipette Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range Options | 0.5–10 µL (V), 5–100 µL (S), 20–200 µL (L), 30–300 µL (K) |
| Minimum Increment | 0.01 µL (V), 0.1 µL (S), 0.2 µL (L), 1 µL (K) |
| Sterilization | Full-unit autoclavable at 121°C for 20 min |
| Tip Compatibility | BMT2-UT/UTWR/UTWRB, FUT/FUTRB, BMT2-SG/SGR/SGRB, FSE/FSERB, FAG/FAGRB, BMT2-K/KR/KRB |
| Material | UV-resistant polymer housing |
| Weight Reduction | ~30% vs. previous generation |
| Ergonomic Design | Rotatable 360° plunger knob, reduced plunger force, serviceable modular construction |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX II |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Sterilization | Autoclavable at 121°C for 20 min |
| Tip Ejection | Non-contact, plastic ejector mechanism |
| Sealing Material | PTFE in air-tight components |
| Piston Material | Ceramic (for ≥200 µL models) |
| Filter Tip Compatibility | Integrated filter sleeve (≥1000 µL models) |
| Volume Adjustment | Digital dial with lockable knob |
| Minimum Increment | 0.002–10 µL (model-dependent) |
| Tip Compatibility | BMT2-series tips (UT, SS, SG, LE, X, Z) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX Plus II |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Tip Compatibility | BMT2-series (UT, SS, SE, L, X, Z) |
| Sterilization | Autoclavable (121°C, 20 min) & UV-Capable |
| Calibration | In-lab adjustable via integrated locking dial |
| Piston Material | Ceramic (≥100 µL), Fluoropolymer-coated stainless steel (≤10 µL) |
| O-rings | FKM (fluoroelastomer) |
| Spring | Corrosion-resistant alloy |
| Chemical Resistance | Verified against strong acids, bases, ketones, esters, aldehydes, and inorganic/organic solvents |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Pipette Mate NEO |
| Power Source | Rechargeable Lithium-Ion Battery (Charging Time: 4 h |
| Input Voltage | 100–240 V, 50/60 Hz, 0.2 A |
| Filter | Hydrophobic PTFE, 20 mm × 0.2 µm |
| Compatible Pipettes | 1–100 mL glass or plastic serological pipettes |
| Sterilization | Autoclavable at 121 °C for 20 min (liquid-contact components only) |
| Weight | 167 g |
| Certifications | CE, RoHS |
| Operating Environment | Compatible with laminar flow hoods and UV sterilization workflows |
| Ergonomics | Integrated speed control dial, vertical stand-alone design (no support rack required) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Pipette Mate NEO |
| Instrument Type | Single-Channel Electric Pipette Controller |
| Power Source | Rechargeable Lithium-Ion Battery (3.6 V, 600 mAh) |
| Operating Time | ~1700 dispenses per full charge (4-hour charging time) |
| Pipette Compatibility | 1–100 mL plastic or glass serological pipettes |
| Filter | Hydrophobic 0.2 µm (20 mm diameter) |
| Compliance | CE, RoHS |
| Autoclavable Components | Nosecone, Silicone Holder, Filter |
| Weight | 167 g |
| Ergonomic Design | Self-standing, UV-resistant housing |
| Speed Control | Dial-type adjustable suction/dispense speed |