Liquid Handling Equipment
Filter
Showing 361–390 of 591 results
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Type | Sterilizable Disposable Pipette Tips |
| Packaging Options | Bulk (1000 pcs) and Rack (96-well or 50-well formats, sterilized or non-sterilized) |
| Volume Range | 0.1–10 µL, 0.5–10 µL, 2–200 µL, 50–300 µL, 100–1000 µL, 1000–5000 µL, 1000–10000 µL |
| Material | High-purity polypropylene (PP) |
| Sterilization | Autoclavable at 121 °C for 20 minutes |
| DNase/RNase-Free | Yes (except X and Z series) |
| UV-Compatible | Yes |
| Brand | Drummond |
|---|---|
| Origin | USA |
| Model | Original Portable Pipet-Aid® |
| Power Source | Rechargeable Battery (2000 cycles per charge) |
| Aspiration Rate | 25 mL in 5 seconds (using 100 mL serological pipette) |
| Voltage | 220 V |
| Compliance | CE-marked for laboratory use |
| Accessories | Wall-mounted cradle, Tissue Culture Nosepiece |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4878 |
| Operating Pressure | 5000 psi |
| Operating Temperature | 500 °C |
| Sample Capacity | 6 vials |
| Dimensions | 35 × 40 × 110 cm |
| Compliance | Compatible with all standard Parr autoclaves and pressure vessels |
| Purge Function | Integrated automated inert-gas purge cycle |
| Control Interface | Touchscreen HMI with graphical workflow display |
| Connectivity | iOS/Android remote monitoring support |
| Footprint | 33 × 33 cm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OilPrep 4 |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OilPrep 8 |
| Pricing | Available Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Compatibility | Eppendorf, Thermo Fisher (Finnpipette, AccuJet), Dragon (DL-1000 series) |
| Volume Range | 0.1–1000 µL |
| Max Capacity per Tip | 1000 µL (1 mL) |
| Material | Perfluoroalkoxy (PFA), USP Class VI Certified |
| Sterility | Optional Gamma Irradiation (SAL 10⁻⁶) |
| Packaging | Non-pyrogenic, DNA/RNase-Free, Filtered or Non-filtered Options |
| Quantity per Rack | 96-well format (standard) |
| Compliance | ISO 8573-1 Class 4 (compressed air purity), ISO 13485:2016 (medical device QMS), ASTM D638 (tensile properties of plastics) |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | IPS-6080 |
| Sample Throughput | 40 columns per run |
| Compliance | Chinese Pharmacopoeia, GB Standards for Mycotoxins, EU Commission Regulations (e.g., No. 401/2006), AOAC Official Methods of Analysis |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-250C |
| Price | USD 1,700 (est.) |
| Particle Detection Range | 0.05–10 µm |
| Sample Throughput Capacity | 1,000 configurable size channels |
| Flow Rate | 5–1500 mL/min |
| Flow Accuracy | < ±1% |
| Sample Volume Handling | 100 mL – 100 L |
| Viscosity Range | 0–99 cSt (offline), up to 500 cSt (pressurized) |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Detection Principle | Dual-Laser Obstruction (Light Blockage) |
| Sensor Generation | 8th-Generation Dual-Narrow-Beam Laser Particle Sensor |
| Calibration Standards | GBW Reference Materials, CN-PSL, CN-ISO, CN-NIST Traceable |
| Compliance | ISO 11171, ISO 4406, ASTM D7619, USP <788>, JIS B 9921, SEMI F39, IEC 60404-16 |
| Output Interfaces | RS232 / RS485 (MODBUS RTU), USB, LAN, 4–20 mA analog |
| Software Platform | CCACS 2.0 Integrated Analysis Suite |
| Control Architecture | Industrial PC or Embedded IPC with Military-Grade HMI |
| Display | Color LCD Touchscreen + Keyboard/Mouse Support |
| Reporting | Particles/mL + ISO 4406 / NAS 1638 / SAE AS4059 / GJB 420B Class Codes |
| Brand | Qingshijie |
|---|---|
| Origin | Shenzhen, China |
| Model | TC-01 |
| Titration Principle | Potentiometric/Colorimetric Endpoint Detection (Auto-Endpoint Recognition) |
| Adjustable Flow Rates | Fast / Medium / Slow |
| Volume Resolution | 0.01 mL |
| Repeatability | ≤0.1% RSD |
| Dispensing Mechanism | High-Precision Peristaltic Pump |
| Tubing Material | Platinum-Cured Silicone Rubber (Acid/Base Resistant) |
| Display | LED Backlit LCD with Real-Time Volume & Result Readout |
| Data Storage Capacity | 2,000 Titration Records |
| Operating Environment | 0–50 °C, 0–90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Compliance | Designed for ASTM D129, ISO 9297, USP <541>, and GLP-compliant workflows |
| Software Features | Onboard Calculation Engine, Auto-Result Reporting, Endpoint Confirmation Algorithm |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Type | Electronic & Manual Repeater Pipettes |
| Volume Range (AutoRep E) | 1 µL – 50 mL |
| Volume Range (AutoRep S) | 2 µL – 5 mL |
| Power | Rechargeable NiMH battery (AutoRep E) |
| Compliance | ISO 8655-3 compliant for repeater pipettes |
| Accessories | Pre-assembled piston-driven syringe tips (sterile/non-sterile), volume setting cards, charging base, AC adapter, shelf mount |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | BenchSmart™ 96 |
| Pipetting Range | 0.5–1000 µL |
| Compatible Tip Types | 0.5–20 µL, 20–200 µL, 100–1000 µL |
| Control Interface | Integrated Touchscreen |
| Pipetting Modes | Basic, Advanced, Dilution, Continuous Dispensing, Reverse Pipetting, Sequential Volume, Mixing, Cycle Counting |
| Tip Exchange | Triple Interchangeable Pipetting Heads |
| Footprint Optimization | Quad-Reservoir Layout Support |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software | Onboard protocol editor with audit trail capability (21 CFR Part 11 ready) |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | BenchSmart™ 96 |
| Instrument Type | Multi-Channel Pipettor |
| Automation Level | Semi-Automatic |
| Channel Configuration | 96-channel (with optional 384-well compatibility) |
| Volume Range | 0.5–1000 µL |
| Maximum Capacity | 1000 µL |
| Accuracy | ±1% |
| Interchangeable Pipetting Heads | Three (0.5–20 µL, 20–200 µL, 100–1000 µL) |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DX |
| Instrument Type | Manual Bottle Top Dispenser |
| Capacity Ranges | 0.5–5 mL, 1–10 mL, 2.5–25 mL, 5–50 mL |
| Chemical Compatibility | Broad (including corrosive and flammable liquids) |
| Sterilization | Autoclavable (121°C, 20 min) |
| Safety Features | Integrated discharge tube with safety cap, grooved tube for correct alignment, inert PTFE/glass piston assembly in polypropylene sleeve |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Type | Manual Bottle Top Dispenser |
| Volume Ranges | 0.5–5 mL, 1–10 mL, 2.5–25 mL, 5–50 mL |
| Compatibility | Corrosive and flammable liquids |
| Sealing Performance | Stable across broad temperature and viscosity ranges |
| Regulatory Context | Designed for GLP/GMP-aligned workflows, compliant with ISO 8655-3 for piston-operated liquid handlers |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E-Man |
| Type | Electronic Hybrid Pipette with Real-time Piston Sensing |
| Volume Range Options | 0.1–2 µL, 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 200–2000 µL |
| Display | High-contrast LCD showing real-time piston position and 4-digit volume setting |
| Compliance | Designed for GLP/GMP environments with audit-ready maintenance tracking |
| Ergonomics | LTS (Low-Torque Seal) tip ejection system and ISO 8655-compliant ergonomic design |
| Accessories | CR-7 rotating stand, HU-M3 magnetic hook, HU-S3 adhesive hook, HU-A3 adapter |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E4 XLS |
| Instrument Type | Multichannel Pipette |
| Automation Level | Electronic Pipette |
| Channel Count | 6 or 8 |
| Volume Range | 5–1200 µL |
| Maximum Capacity | 1200 µL |
| Accuracy | ±0.8% at 1.2 µL and 9.6 µL |
| Compliance | GLP/GMP-ready, password-protected settings and service alerts, tamper-proof usage logs |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | E4 XLS |
| Instrument Type | Multichannel Pipette |
| Automation Level | Electronic Pipette |
| Channel Count | 6 or 8 |
| Volume Range | 5–1200 µL |
| Maximum Capacity | 1200 µL |
| Accuracy | ±0.8% at 1.2 µL and 9.6 µL |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | E4 XLS+ Adjustable Spacing |
| Type | Electronic Multichannel Pipette |
| Channels | 6 |
| Volume Range | 20–300 µL |
| Accuracy | ±2.5% at 0.75 µL, ±0.8% at 1.2 µL and 2.4 µL |
| Precision (CV) | ≤1.0% at 0.3 µL, ≤0.25% at 0.375 µL, ≤0.15% at 0.45 µL |
| Minimum Increment | 0.2 µL |
| Adjustable Tip Spacing | 9–19 mm (6-channel) |
| Compliance | GLP/GMP-ready with audit-trail-capable service logging and password-protected protocol settings |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E4 XLS+ |
| Instrument Type | Multi-Channel Pipette |
| Automation Level | Electric |
| Channel Count | 8 or 12 |
| Volume Range | 0.01–1200 µL |
| Accuracy (at 0.04 µL) | ±4.0 % |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible audit trail support |
| Tip System | LTS (Low Retention Standard) |
| Display | Full-color high-resolution LCD |
| Navigation | Rotary encoder + ergonomic joystick |
| Battery | Rechargeable Li-ion, >10,000 pipetting cycles per charge |
| Onboard Memory | Stores ≥20 user-defined protocols |
| Calibration | Auto-zero reset after each pipetting cycle |
| Ergonomics | Ambidextrous design, glove-compatible, tip ejection force ≤0.6 kg (with LTS tips) |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | E4 XLS+ |
| Automation | Electronic |
| Channels | 1 |
| Volume Range | 1–10 µL |
| Accuracy | ±4.0% at 0.04 µL, ±1.5% at 0.075 µL, ±1.0% at 0.1 µL |
| Precision (CV) | ≤0.4% at 0.04 µL, ≤0.6% at 0.03 µL, ≤3.0% at 0.03 µL |
| Minimum Increment | 0.01 µL |
| Tip System | LTS (Low Retention Tip) |
| Compliance | GLP/GMP-ready, password-protected settings, audit-trail-capable service logging |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | E4-10XLS+ |
| Type | Electronic Single-Channel Pipette |
| Automation Level | Motorized |
| Display | Full-color graphical LCD |
| Control Interface | Joystick + rotary navigation dial |
| Calibration | Auto-zeroing at end of each pipetting cycle |
| Precision | 4,000-step stepper motor actuation |
| Ergonomics | Ambidextrous, glove-compatible, LTS (Low-Torque Spring) tip ejection |
| Tip Ejection Force | ≤0.6 kg (with LTS tips) |
| Battery Life | >1 day per charge |
| Data Security | Password-protected settings, GLP-compliant audit trail, tamper-proof service logs |
| Software Integration | Preloaded PureSpeed™ protocol suite for biomolecule purification |
| Compliance | Designed to support GLP/GMP workflows, 21 CFR Part 11 readiness via optional software interface |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | SE4-10XLS+ |
| Volume Range | 0.5–10 µL |
| Type | Single-Channel Electronic Pipette |
| Drive Mechanism | Stepper Motor (4,000-step resolution) |
| Display | Full-color graphical LCD |
| Control Interface | Joystick + rotary navigation dial |
| Calibration | Auto-zeroing at end of each pipetting cycle |
| GLP/GMP Compliance | Password-protected settings, tamper-proof service logs, audit trail-capable |
| Power | Rechargeable lithium-ion battery (≥1 day runtime, >1,000 charge cycles) |
| Ergonomics | Ambidextrous design, LTS (Low-Torque Seal) tip ejection system (ejection force ≤0.6 kg), integrated finger hooks, glove-compatible operation |
| Software Integration | Preloaded PureSpeed™ mode for biomolecule purification (proteins, oligonucleotides) |
| Onboard Memory | Multiple user-defined protocols stored locally |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | EA6-300XLS |
| Instrument Type | Electronic Multichannel Pipette |
| Channels | 6 |
| Volume Range | 20–300 µL |
| Increment | 0.2 µL |
| Accuracy (at 30/150/300 µL) | ±2.5% / 0.75 µL, ±0.8% / 1.2 µL, ±0.8% / 2.4 µL |
| Precision (at 30/150/300 µL) | ±1% / 0.3 µL, ±0.25% / 0.375 µL, ±0.2% / 0.6 µL |
| Tip Ejection | LiteTouch System (LTS) |
| Compliance | GLP/GMP-ready with password-protected configuration, protocol storage, and service alerts |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | LA6 / LA8 |
| Volume Range Options | EA6-300 (20–300 µL, 6-channel), EA6-1200 (100–1200 µL, 6-channel), EA8-50 (5–50 µL, 8-channel), EA8-300 (20–300 µL, 8-channel), EA8-1200 (100–1200 µL, 8-channel) |
| Power | Rechargeable Lithium-ion Battery (Model 6107-040) |
| Accessories | CR-7 Rotating Stand, HU-M3 Magnetic Hook, HU-S3 Adhesive Hook, HU-A3 Hook Adapter, E3-WPS Wall-Mounted Charging Power Supply, E3-RCS Rapid Charging Station |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E3/SE3 |
| Volume Range Options | 1–10 µL to 100–1200 µL (8-, 12-, 16-, and 24-channel configurations) |
| Drive Mechanism | Microprocessor-Controlled Stepper Motor |
| Tip Ejection System | LTS (Low-Torque Tip System) |
| Power Source | Rechargeable Lithium-Ion Battery |
| Compliance | ISO 8655-2, ISO 8655-5, GLP/GMP-ready data integrity support |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | EDP3 |
| Volume Range Options | 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 200–2000 µL, 500–5000 µL, 1–10 mL, 2–20 mL |
| Tip System | LTS (Low Retention Technology) |
| Power Source | Rechargeable Lithium-ion Battery |
| Compliance | ISO 8655 compliant, GLP/GMP-ready with audit trail capability (via Liquidator™ Software) |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | L8-10XLS+ |
| Pipette Type | Manual Multichannel |
| Channels | 8 |
| Volume Range | 0.5–10 µL |
| Increment | 0.02 µL |
| Accuracy (±) | 4% / 0.04 µL (at 1 µL), 1.5% / 0.075 µL (at 5 µL), 1% / 0.1 µL (at 10 µL) |
| Precision (CV, ±) | 5% / 0.05 µL (at 1 µL), 1.5% / 0.075 µL (at 5 µL), 0.5% / 0.05 µL (at 10 µL) |
| Tip Ejection System | LiteTouch™ (LTS) |
| Weight | Lightweight Design Optimized for Ergonomics |
| Brand | RAININ |
|---|---|
| Origin | Switzerland |
| Model | Liquidator 96 |
| Type | Manual High-Throughput Pipetting System |
| Compatibility | 96-well and 384-well plates |
| Ergonomic Design | Yes |
| Software Requirement | None |
| Regulatory Compliance | ISO 8655-compliant pipette performance, CE-marked, RoHS compliant |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | Liquidator™ 96 |
| Channel Configuration | 96-channel |
| Volume Range | 5–200 µL |
| Compatible Plate Formats | 96-well and 384-well microplates (with optional adapter) |
| Ergonomic Design | Yes |
| Software Requirement | None |
| Compliance | ISO 8655-compliant calibration methodology, LTS® tip system certified for traceable accuracy |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | Rainin® |
| Tip Compatibility | LTS (Low-Torque Seal) and XLS+ platforms |
| Sterilization | Autoclavable (121°C, 20 min) |
| Material | Medical-grade polypropylene (PP) for tips |
| Volume Range | 10 µL, 250 µL, 1000 µL |
| Packaging Formats | Green-Pak™ single-box refills (96 tips), SpaceSaver™ stackable refills (8 or 10 trays per pack), TerraRack™ 100% recyclable racks, Bulk bags (1,000 tips/bag, 10 bags/box = 10,000 tips), StableStak™ high-density stacking system (768 tips per 10×96 configuration), StableRack™ dual-96 format (35% less plastic vs. two standard racks) |
| Regulatory Compliance | ISO 8573-1 Class 0 certified air purity, DNase/RNase-free, non-pyrogenic, tested per ASTM D257 (surface resistivity), USP <85> endotoxin testing ≤0.03 EU/mL |