| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | T300 |
| Display | TFT LCD |
| Pipetting/Dosing Volume Options | 20 mL or 50 mL Duran® borosilicate glass burettes |
| Tubing Material | PTFE |
| Dosing Accuracy | ±0.15% systematic error, ±0.05% random error (per EN ISO 8655-6) |
| Flow Rate Control | 5 adjustable speed levels |
| Connectivity | 1× USB-A, 1× USB-B, 2× RS-232-C |
| Stirring Interface | Compatible with TM50 magnetic stirrer (M2 kit standard) |
| Software Integration | TitriSoft™ for remote operation, method storage, audit trail, and data export (USB drive, print) |
| Weighing Interface | Optional integration with analytical balances via RS-232 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (w×d×h) | 135 × 310 × 205 mm (with burette, excluding stirrer) |
| Weight | 2.0 kg (without stirrer) |
| Compliance | EN ISO 8655-6 (volumetric accuracy), CE marked |
| Wetted Materials | PTFE, Duran® borosilicate glass, FEP-coated components |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | T500 |
| Display | 3.5″ 1/4 VGA TFT color LCD |
| Pipetting Volume Range | 5–50 mL (interchangeable syringe modules) |
| Accuracy | System error ≤0.15%, random error 0.05–0.07% |
| Compliance | DIN EN ISO 8655-6 Part 3 |
| Communication | 2× USB-A, 1× USB-B, 2× RS-232-C |
| Power Supply | 90–240 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 153 × 450 × 296 mm |
| Weight | 3.5 kg (with module) |
| Wetted Materials | PTFE and borosilicate glass |
| Software Compatibility | TitriSoft 3.0 |
| Daisy-chain Capacity | Up to 16 units |
| Stirring Module Options | M1 (base), M2 (includes 20 mL smart module) |
| Volume Resolution | 0.005–0.025 mL (dependent on syringe size) |
| Viscosity Limit | <10 mm²/s |
| Operating Control | Standard mouse (included), optional mini keyboard |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Vdose1200 |
| Dispensing Unit | Single-Channel |
| Flow Rate | 1.25 µL/min to 375 mL/min |
| Accuracy | ≤ 0.5% |
| Resolution | 1/6000 of syringe volume |
| Syringe Volume Range | 50 µL to 25 mL |
| Wetted Materials | Borosilicate Glass, PTFE, Viton |
| Valve Type | 3-Port Automated Switching Valve |
| Communication Interface | RS-232 / RS-485 |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Dimensions (H×W×D) | 305 × 89 × 330 mm |
| Weight | 5.5 kg |
| Order Code | V900703 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Vdose2400 |
| Dispensing Unit Configuration | Dual-Channel |
| Flow Rate Range | 1.25 µL/min – 375 mL/min |
| Accuracy | ≤ 0.5% (5 ‰) |
| Dispensing Volume Range per Channel | 50 µL – 25 mL |
| Syringe Material Options | Borosilicate Glass / PTFE |
| Valve Material | Viton / PTFE |
| Valve Type | 3-Port Automated Switching Valve |
| Syringe Resolution | 1/6000 of total syringe volume |
| Communication Interface | RS-232 / RS-485 |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Dimensions (H × W × D) | 305 × 178 × 330 mm |
| Weight | 9.1 kg |
| Order Code | V900702 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | BSZ-16 |
| Collection Capacity | 16 × 100 mL tubes |
| Timing Range | 1 minute to 24 hours (adjustable in 1-minute increments) |
| Power Failure Data Retention | ≥10 years |
| Dimensions (W×D×H) | 260 × 250 × 340 mm |
| Brand | Chu Ding |
|---|---|
| Origin | Shanghai, China |
| Model | DBS-100 / DBS-160 |
| Tube Capacity | 100 × 12 mL (DBS-100) or 160 × 5 mL (DBS-160) |
| Timing Range | 1 s – 199 h 59 min 59 s (DBS-100) |
| Drop Counting Range | 1–9999 drops |
| Peak Detection Range | 0–100 mV |
| Power-Fail Data Retention | ≥10 years |
| Dimensions (W×D×H) | 260 × 250 × 340 mm |
| Brand | Chu Ding |
|---|---|
| Origin | Shanghai, China |
| Model | DBS-160 |
| Tube Capacity | 160 × 5 mL |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Drop Counting Range | 1–9999 drops |
| Peak Trigger Range | 0–100 mV |
| Data Retention (Power Loss) | ≥10 years |
| Control System | Embedded microcontroller with LCD menu interface |
| Dimensions (L×W×H) | 265 × 350 × 360 mm |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | CBS-A / CBS-B / CBS-C |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 9999 s or 1 min – 9999 min |
| Droplet Counting Range | 1–9999 drops (CBS-B & CBS-C) |
| Peak Trigger Range | 0–1000 mV (CBS-B & CBS-C) |
| Programmable Programs | 10 |
| Movement | X-Y programmable positioning with auto-tube alignment |
| Display | High-precision blue LCD screen |
| Interface | RS232C serial port (CBS-C) |
| Data Retention | 10 years after power loss |
| Dimensions | 358 × 345 × 250 mm |
| Weight | 10 kg |
| Tube Tray Options | 16 / 36 / 100 / 169 positions (A-type tray solvent-resistant |
| Compliance | Designed for aqueous and organic solvent compatibility (e.g., acetonitrile, methanol, chloroform, THF) |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | CBS-C |
| Collection Capacity | 100 tubes (12 mL max per tube) |
| Timing Range | 1 s – 9999 s / 1 min – 9999 min |
| Droplet Counting Range | 1–9999 drops |
| Peak Threshold Range | 0–1000 mV |
| Data Retention | ≥10 years after power loss |
| Dimensions (L×W×H) | 358×345×250 mm |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | DBS-160N |
| Tube Capacity | 160 × 5 mL |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Drop Counting Range | 1–9999 drops |
| Peak Detection Range | 0–100 mV |
| Power-Fail Data Retention | ≥10 years |
| Control System | Microprocessor-based with LCD menu interface |
| Compatibility | Compatible with HL-series peristaltic pumps and TH-series gradient mixers |
| Construction | Chemically resistant housing and fluid path for organic solvents (e.g., chloroform, acetone, methanol, acetonitrile, DMSO) |
| Brand | Coevos |
|---|---|
| Model | IDP C |
| Origin | Beijing, China |
| Type | Single-Channel Electronic Pipette |
| Volume Range | 10 µL – 5 mL |
| Accuracy | ±1% (at nominal volume) |
| Precision (CV) | ≤0.6% (at 5 mL), ≤1.05% (at 50 µL) |
| Power | Rechargeable Li-ion battery with USB-C interface |
| Display | High-resolution monochrome LCD with real-time parameter feedback |
| Ergonomics | Weight: ~95 g (IDP C-5000), balanced center of gravity, soft-grip elastomeric sleeve |
| Control | Five-way tactile joystick with silicone dome |
| Tip Ejection | Intelligent capacitive touch button with auto-reset and tip-count tracking |
| Tip Compatibility | Universal fit for ISO 8655-compliant standard conical tips (including Gilson, Eppendorf, Thermo Fisher, and Rainin) |
| Certifications | Complies with ISO 8655-2:2022 (volumetric performance), ISO 8655-5:2022 (electronic pipettes), and supports GLP/GMP traceability via audit-log-enabled firmware |
| Software Integration | Co-AICal™ intelligent calibration algorithm (Chinese Invention Patent ZL202210XXXXXX.X), OTA firmware updates, WeChat Mini Program remote configuration |
| Brand | Coevos |
|---|---|
| Origin | Beijing, China |
| Model | IDP X 4-Channel |
| Type | Multi-Channel Electronic Pipette |
| Channels | 4 |
| Volume Range | 125–1250 µL |
| Maximum Capacity | 1250 µL |
| Automation Level | Motorized |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Integration | Co-Link™ bidirectional communication protocol |
| Calibration | Auto-initialization of well spacing on power-up |
| Display | Integrated capacitive touchscreen interface |
| Ergonomics | Rotatable lower tip carriage with vibration-free spacing adjustment |
| Predefined Configurations | Three factory-set plate formats (96-, 384-, and 24-well) |
| Tip Compatibility | Universal low-retention filtered tips (0.1–1 mL range) |
| Data Traceability | On-device operation log with timestamped parameter history |
| Brand | Coevos |
|---|---|
| Origin | Beijing, China |
| Model | IDP X (8/12-Channel, Adjustable Spacing) |
| Type | Electric Multichannel Pipette |
| Channels | 8 or 12 |
| Volume Range | 12.5–1250 µL |
| Maximum Capacity | 1250 µL |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Integration | Co-Link™ bidirectional communication protocol |
| Calibration | Auto-alignment on startup, 14-point calibration support |
| Display | High-resolution capacitive touchscreen interface |
| Ergonomics | Rotatable lower tip carriage, vibration-free spacing adjustment |
| Plate Compatibility | 384-well (4.5 mm), 96-well (9 mm), 48-well (13 mm), 24-well (19 mm), 12-well (26 mm) plates |
| Brand | Coevos |
|---|---|
| Origin | Beijing, China |
| Model | IDP X 6-Channel |
| Instrument Type | Electronic Multichannel Pipette |
| Channels | 6 |
| Volume Range | 125–1250 µL |
| Maximum Capacity | 1250 µL |
| Automation Level | Motorized |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Integration | Co-Link™ bidirectional communication protocol |
| Calibration | Auto-alignment on startup, 14-point calibration support |
| Display | Integrated capacitive touchscreen interface |
| Ergonomics | Rotatable lower tip carriage, vibration-free spacing adjustment |
| Certified Compatibility | ANSI/SLAS standards for microplate formats (96-, 384-, 48-, 24-, and 12-well plates) |
| Brand | COEVOS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IDP-E 12-Channel |
| Instrument Type | Multichannel Electronic Pipette |
| Automation Level | Motorized |
| Number of Channels | 12 |
| Volume Range | 12.5–1250 µL |
| Maximum Capacity | 1250 µL |
| Brand | Coevos |
|---|---|
| Model | IDP-E 8-Channel |
| Type | Electronic Multichannel Pipette |
| Automation Level | Motorized |
| Channels | 8 |
| Volume Range | 0.5–1250 µL |
| Maximum Volume | 1250 µL |
| Calibration Method | 14-Point Co-AlCal™ Intelligent Calibration |
| Drive Mechanism | Precision Stepper Motor with Pneumatic Screw Actuation |
| Durability | >2,000,000 Actuation Cycles |
| Data Logging | Onboard Timestamped Operation Records (Volume, Mode, User ID, Date/Time) |
| Connectivity | USB-C for Firmware Updates and Parameter Sync |
| Compliance | Designed to Support GLP/GMP Traceability Requirements (Audit Trail Ready) |
| Brand | Coevos |
|---|---|
| Model | IDP-E |
| Type | Electronic Single-Channel Pipette |
| Automation Level | Motorized |
| Volume Range | 12.5 µL – 5 mL |
| Maximum Capacity | 5 mL |
| Accuracy | ±1% |
| Origin | Beijing, China |
| Compliance | ISO 8655-compliant design principles |
| Software Capability | Over-the-air firmware updates, audit-trail-enabled operation logging |
| Brand | Coevos |
|---|---|
| Origin | Beijing, China |
| Model | IDP-S 8-Channel |
| Instrument Type | Multichannel Electronic Pipette |
| Automation Level | Motorized |
| Channels | 8 |
| Volume Range | 0.5–1250 µL |
| Maximum Capacity | 1250 µL |
| Calibration Method | Co-AlCal 14-Point Intelligent Calibration |
| Connectivity | Co-Link™ Bidirectional Communication Protocol |
| Data Logging | Onboard Audit Trail (Operator ID, Timestamp, Volume, Mode, Tip Type) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Coevos |
|---|---|
| Origin | Beijing, China |
| Model | IDP-S |
| Type | Motorized Single-Channel Pipette |
| Volume Range | 2.5 µL – 5 mL |
| Max Capacity | 5 mL |
| Compliance | ISO 8655-1:2022, ASTM E2758-21, GLP/GMP-ready data logging |
| Connectivity | Wi-Fi (Co-Link Industrial IoT Protocol, CN Patent No. ZL202210XXXXXX.X) |
| Certifications | Red Dot Award 2023 (Product Design), CE, RoHS |
| Power | USB-C + magnetic docking station with overcharge protection |
| Ergonomics | <95 g weight, silicone-coated 5-way joystick, adjustable tip ejection force, removable lower assembly for autoclaving (121°C, 20 min) |
| Brand | Coevos |
|---|---|
| Origin | Beijing, China |
| Model | IDP-S12 |
| Type | Electric Multichannel Pipette |
| Channels | 12 |
| Volume Range | 0.5–1250 µL |
| Max Capacity | 1250 µL |
| Connectivity | Wi-Fi-enabled Co-Link Industrial IoT Platform |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Certifications | Red Dot Award Winner 2023 (Product Design) |
| Brand | Coolium |
|---|---|
| Origin | Beijing, China |
| Model | VPC-300 |
| Ultimate Vacuum | 1.5×10⁻⁹ torr |
| Maximum Water Vapor Pumping Speed | 250,000 L/s |
| Dimensions (W×D×H) | 500 × 550 × 1200 mm |
| Operating Temperature Range | −100 °C to −150 °C (down to −165 °C) |
| Refrigerant | Eco-friendly mixed refrigerant |
| Cooling Method | Air-cooled (ambient 5–35 °C) |
| Electrical Supply | 380 V / 3-phase / 50 Hz / 6.5 kW |
| Safety Protections | 6-channel (discharge pressure high/low, discharge temperature high, condensing temperature out-of-range, compressor overload/overheat, phase sequence error) |
| Control Interface | Local HMI + RS485 remote communication |
| Dual-load capability | Yes |
| Cryocoil surface area | 1.0 m² |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cybi-FeliX |
| Pricing | Available Upon Request |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | APT-1000 |
| Display | 10-inch capacitive color touchscreen |
| Titration Modes | Dynamic, Endpoint, Equivalence-Point, Manual |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −2.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Resolution | mV: 0.1 mV |
| pH | 0.001 pH |
| Temp | 0.1 °C |
| Accuracy | mV: ±0.1 mV or ±0.03% FS |
| pH | ±0.01 pH |
| Temp | ±0.1 °C |
| Repeatability (Titration) | ≤0.2% RSD |
| Electronic Unit Repeatability | ≤0.2 mV |
| Drift Stability | ±0.3 mV / 3 h |
| Burette Capacity | 10 mL |
| Burette Resolution | 1/96,000 steps |
| Material Compatibility | Acid-/alkali-resistant fluidic path (PP, PTFE, FEP, ceramic valves) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | APT-2000 |
| Pricing | Available Upon Request |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −20.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Resolution | 0.1 mV, 0.001 pH, 0.1 °C |
| Accuracy | ±0.1 mV (±0.03% of reading), ±0.003 pH, ±0.1 °C |
| Burette Options | 1 mL / 5 mL / 10 mL / 25 mL (standard: 10 mL) |
| Burette Resolution | 1/48000 steps |
| Refill Time (100%) | 16 s |
| Stirring Method | Magnetic stirring |
| Electrode Interfaces | mV/pH input, reference electrode input, temperature probe input |
| Connectivity | USB, power interface |
| Burette Material | PTFE |
| Drive Mechanism | Micro-stepping motor |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | V2.5 |
| Instrument Type | Single-Channel Manual Pipette |
| Volume Range | 1–10 mL |
| Maximum Capacity | 10 mL |
| Accuracy Error | ±0.60% (at 5 mL) |
| Repeatability Error | ±0.20% (at 5 mL) |
| Increment | 0.1 mL |
| Tip Compatibility | Standard conical universal pipette tips (10 mL volume class) |
| Key | Brand: DELEITE |
|---|---|
| Origin | Shanghai, China |
| Type | Manual Multichannel Pipette |
| Channels | 8 |
| Volume Range | 0.5–10 µL |
| Maximum Capacity | 10 µL |
| Accuracy | ±2.50% / ±0.125 µL |
| Increment | 0.1 µL |
| Tip Compatibility | 10 µL low-retention tips |
| Test Volume | 5 µL |
| Regulatory Classification | Domestic-manufactured laboratory instrument for general research use |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MD-12 |
| Plate Capacity | 1 |
| Dispensing Accuracy | ≤ ±3% for 10–20 µL |
| Dispensing Range | 5–100,000 µL (discrete or continuous) |
| Throughput | 12 samples per run |
| Dimensions | 414 × 394 × 320 mm (W × D × H) |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MD-8 |
| Plate Capacity | 1 × 96-well plate |
| Dispensing Range | 5–5000 µL |
| Accuracy | ≤ ±3% at 10–20 µL |
| Throughput | 8 samples per cycle |
| Dimensions | 350 × 300 × 400 mm (W × H × D) |
| Brand | BRAND (Brandt GmbH / BRAND) |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Vernier-Adjustable Type |
| Instrument Type | Manual Bottle Top Dispenser |
| Price Range | USD 650 – 1,300 (FOB Hamburg) |
| Operating Limits | Max. vapor pressure 500 mbar |
| Wetted Materials | Borosilicate glass, ceramic, platinum-iridium alloy, ETFE, FEP, PFA, PP (safety cap) |
| Brand | BRAND |
|---|---|
| Origin | Germany |
| Type | Manual Bottle Top Dispenser |
| Adjustment Mechanism | Digital Adjustable & Easy-Calibration Design |
| Material Compatibility | Borosilicate Glass, Ceramic, Platinum-Iridium Alloy, ETFE, FEP, PFA, PP (Safety Cap) |
| Operating Limits | Max. Vapor Pressure 500 mbar |