Liquid Handling Equipment
Filter
Showing 151–180 of 490 results
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | 2–20 µL |
| Accuracy (±) | 0.9% |
| Precision (CV) | 0.4% |
| Volume Adjustment Increment | 0.5 µL |
| Tip Compatibility | 300 µL universal low-retention tips |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Regulatory Compliance | ISO 8655-2:2022, GLP-ready design |
| Brand | DW-Micro |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | DW-JURAY |
| Price Range | USD 7,000 – 14,000 |
| Weighing Accuracy | ±0.01 g |
| Liquid Dispensing Accuracy | ±0.1 g |
| Dilution Accuracy | >99% |
| Dilution Factor Range | 1/2 to 1/99 (2-fold to 99-fold) |
| Maximum Dilution Volume | 250 mL |
| Dilution Time (DW-JURAY) | <60 s |
| Dilution Time (DW-JURAY-2) | <20 s |
| Display | Backlit LCD with Real-Time Weight & Ratio Readout |
| Data Storage | Onboard Microprocessor with Audit-Trail-Capable Logging |
| Compliance | GB 4789, ISO 6887-1, ISO 7218 |
| Power Supply | 220 V AC, 50 Hz (with Universal Adapter Option) |
| Brand | Eppendorf |
|---|---|
| Country of Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Easypet 3 |
| Instrument Type | Single-Channel Electronic Pipette Controller |
| Automation Level | Motorized |
| Channel Configuration | Single-Channel |
| Volume Range | 0.1 mL – 100 mL |
| Maximum Capacity | 100 mL |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | epMotion 5070/f |
| Plate Positions | 4 |
| Pipetting Accuracy | ±0.5 µL |
| Pipetting Range | 1–1000 µL |
| Sample Throughput | 4 plates per run |
| Dimensions | 65 × 48 × 63 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Imported |
| Model | epMotion 5073l |
| Plate Positions | 6 |
| Pipetting Accuracy | ±0.05 µL |
| Pipetting Range | 1 µL – 1 mL |
| Sample Throughput | 6 samples per run |
| Dimensions (W × D × H) | 68 × 62 × 81 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Imported Instrument |
| Model | epMotion 5075l |
| Plate Positions | 15 |
| Pipetting Accuracy | ±0.05 µL |
| Pipetting Range | 0.2 µL – 1 mL |
| Throughput Formats | 96-well and 384-well plates |
| Dimensions (W × D × H) | 108 × 62 × 87 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Imported |
| Model | epMotion 5075t / 5075m |
| Plate Capacity | 14.5 SLAS/ANSI standard positions |
| Pipetting Accuracy | ±5 % |
| Pipetting Range | 0.2 µL – 1 mL |
| Dimensions (W × D × H) | 108 × 62 × 87 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | epMotion 5075v / 5075vt |
| Plate Positions | 12 |
| Liquid Handling Range | 0.2 µL – 1,000 µL |
| Sample Throughput | 12 samples per run |
| Dimensions (W × D × H) | 108 × 62 × 87 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | epMotion 96 Flex |
| Plate Capacity | 96-position |
| Pipetting Accuracy | ≤ 4.5% at 5 µL |
| Pipetting Range | 0.5–1000 µL |
| Throughput | 96 samples per cycle |
| Dimensions (W×D×H) | 34.5 × 41.5 × 62 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Research plus / Xplorer plus |
| Instrument Type | Multi-channel Pipette |
| Automation Level | Electronic Pipette |
| Channel Count | 4, 6, 8, 12 |
| Volume Range | 1–20 μL, 5–100 μL, 15–300 μL, 50–1,200 μL |
| Maximum Capacity | 1,200 μL |
| Accuracy | ±0.1 μL |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multipette E3/E3x |
| Instrument Type | Single-Channel Electronic Repeater Pipette |
| Automation Level | Motorized |
| Channels | 1 |
| Volume Range | 0.1 µL – 50 mL |
| Maximum Capacity | 50 mL |
| Accuracy | ±0.3% |
| Operating Principle | External Piston (Positive Displacement) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multipette M4 |
| Instrument Type | Single-Channel Manual Dispenser |
| Automation Level | Manual |
| Channels | 1 |
| Volume Range | 1 µL – 10 mL |
| Maximum Reservoir Capacity | 50 mL |
| Accuracy | ±0.3% |
| Principle | External Piston (Positive Displacement) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Reference 2 Multi-Channel |
| Instrument Type | Multi-Channel Pipette |
| Automation Level | Manual |
| Channel Count | 8 or 12 |
| Volume Range | 0.5–300 µL |
| Maximum Capacity | 300 µL |
| Accuracy | ±0.6% |
| Sterilization | Fully autoclavable (121 °C, 20 min, saturated steam) |
| RFID Integration | Yes (requires Eppendorf TrackIT reader accessory) |
| Ergonomic Design | Single-button operation, tactile ejection feedback, low-force tip attachment/detachment, dual-side volume lock, stainless steel top rim, full-angle circular upper housing, four-digit angled volume display |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Imported |
| Model | Reference 2 Single-Channel |
| Instrument Category | Single-Channel Pipette |
| Automation Level | Manual |
| Channels | 1 |
| Volume Range | 0.1 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±0.6 % |
| Sterilization | Fully autoclavable (121 °C, 20 min) |
| RFID Integration | Yes (requires Eppendorf TrackIT reader) |
| Ergonomic Design | Thumb-actuated single-button operation with tactile feedback |
| Tip Ejection | Integrated tip ejection with pre-ejection resistance detection |
| Display | Four-digit volume display, omnidirectional readability |
| Volume Lock | Dual-side mechanical volume lock |
| Tip Compatibility | Universal low-retention and standard conical tips |
| Surface Finish | Electro-polished stainless steel upper housing with soft-touch polymer grip |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Adjustable Volume Single-Channel |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Manual |
| Channels | 1 |
| Volume Range | 0.1–2.5 µL, up to 10 mL (model-dependent) |
| Accuracy Error | ±0.01 % of set volume (typical at nominal volume, per ISO 8655) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.5–10 µL |
| Maximum Capacity | 10 µL |
| Accuracy | ±0.90 % |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Compliance | ISO 8655-2, ISO 8655-5, GLP/GMP-ready |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Research Plus / Xplorer Plus |
| Instrument Type | Multichannel Electronic Pipette |
| Automation Level | Motorized |
| Channel Count | 16 or 24 |
| Volume Range | 1–100 µL |
| Maximum Capacity | 100 µL |
| Accuracy | ±0.1% at full scale |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Research plus |
| Instrument Type | Single-Channel Manual Pipette |
| Channels | 1 |
| Volume Range | 0.1 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±0.6% |
| Sterilization | Full-unit autoclavable at 121 °C, 20 min, 1 bar |
| Ergonomic Certification | Compliant with Eppendorf PhysioCare Concept |
| Piston System | Eppendorf PerfectPiston™ |
| Tip Attachment | Elastic Tip Cone (excludes 5 mL and 10 mL variants) |
| Volume Display | Four-digit magnified digital window |
| Adjustment Mechanism | Rotational volume setting with tactile feedback |
| Density Adjustment | Optional density correction function for non-aqueous or temperature-sensitive liquids |
| Maintenance | Quick-release lower sleeve for cleaning and service (excludes 5 mL and 10 mL variants) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Multichannel Manual Pipette |
| Channels | 8 or 12 |
| Volume Range | 0.5–300 µL |
| Maximum Volume | 300 µL |
| Accuracy | ±0.6% |
| Sterilization | Full-unit autoclavable (121 °C, 20 min, saturated steam) |
| Operating Principle | Air-displacement positive displacement with adjustable volume via dual-stage rotary dial |
| Ergonomic Certification | Compliant with ISO 8549-1:2021 (Ergonomics of manual pipetting) and PhysioCare Concept validated per DIN EN 614-1 |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Research 3 neo |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Manual |
| Channels | 1 |
| Volume Range | 2.5 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Brand | Eppendorf |
|---|---|
| Model | Research® plus 0.5–5 mL |
| Type | Manual Air-Displacement Pipette |
| Channel Count | Single |
| Volume Range | 0.5–5 mL |
| Color Code | Purple |
| Compliance | ISO 8655-2, ISO 8655-5, GLP/GMP-ready documentation support |
| Ergonomic Design | PhysioCare Concept certified |
| Brand | Eppendorf |
|---|---|
| Country of Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Top Buret |
| Price Range | USD 650 – 1,300 |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Varispenser 2 / Varispenser 2x |
| Instrument Type | Electronic Bottle Top Dispenser |
| Sterilization | Autoclavable (121 °C, 20 min, full unit) |
| Chemical Resistance | Full-body PTFE/ETFE/FEP/PFA/PP construction |
| Valve System | Precision piston-driven with integrated recirculation valve (Varispenser 2x only) |
| Dispensing Accuracy | ≤ ±0.5% CV (per ISO 8655-3) |
| Volume Range | Adjustable from 0.2 mL to 100 mL per dispense (model-dependent) |
| Operating Temperature | 10–40 °C |
| Humidity Limit | ≤ 80% RH (non-condensing) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | Xplorer / Xplorer plus |
| Instrument Type | Multi-channel Electric Pipette |
| Automation Level | Motorized |
| Channel Options | 1, 8, 12, 16, or 24 channels |
| Volume Range | 0.5 µL – 1200 µL |
| Maximum Capacity | 1200 µL |
| Accuracy | ±0.6 % |
| Brand | Esco |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TEPAT |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Electronic |
| Channels | 1 |
| Volume Range | 0.2–10 µL, 0.5–20 µL, 2–100 µL, 5–200 µL, 10–300 µL, 10–500 µL, 50–1000 µL, 0.1–5 mL, 1–10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.5% or ±0.025 µL (whichever is greater) |
| Brand | ESEN |
|---|---|
| Origin | Zhejiang, China |
| Model | ADR-60 |
| Material | ETFE/FEP/PFA/PP |
| Sterilization | Autoclavable (121°C, 20 min) & UV-compatible |
| Certifications | ISO 9001:2015, ISO 13485:2016, CE, ISO/IEC 17025 compliant |
| Valve Type | Spring-free recirculating valve |
| Dispensing Range | Adjustable via dual-scale graduated cylinder (precise volume setting) |
| Rotational Design | 360° swivel nozzle |
| Filling Tube | Telescopic (170–300 mm), chemically resistant |
| Sealing System | Wiper-sealed piston with integrated cleaning interface |
| Safety Feature | Lockable recirculation switch to prevent sample loss and reagent waste |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Various |
| Price | ¥1200 |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Manual |
| Channel Count | Single- and Multi-Channel |
| Volume Range | Various |
| Maximum Capacity | 10 mL |
| Accuracy | ±1% (typical, per ISO 8655) |
| Brand | FORTUNA |
|---|---|
| Origin | Germany |
| Model | FORTUNA® OPTIFIX® SAFETY |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.4–100 mL |
| Minimum Increment | 0.1 / 0.5 / 1.0 / 2.0 mL |
| Accuracy | ±1% |
| Error | ±1% |
| Compliance | DIN EN ISO 9001, German Calibration Standard (H-Quality Certification) |
| Materials | PTFE-coated piston, borosilicate glass cylinder, PTFE valve block and adapters (GL32, 40 mm & 45 mm), PP finger guard with laser-etched scale |
| Sealing | 100% metal-spring-free, fully chemically inert construction |
| Brand | FORTUNA |
|---|---|
| Origin | Germany |
| Model | OPTIFIX® SAFETY S |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.4–100 mL |
| Minimum Increment | 0.1, 0.2, 0.5, 1.0, 2.0 mL |
| Accuracy | ±1% |
| Tolerance per Range | ±0.2% to ±0.6% (per DIN EN ISO 8655-3) |
| Dispensing Cylinder Material | Borosilicate Glass |
| Piston Coating | PTFE |
| Seals | Chemically Resistant Elastomers |
| Safety Valve | Integrated Pressure Relief with Exhaust Tube |
| Connection | GL32 Thread |
| Adapters Included | PTFE 40 mm & 45 mm |
| Delivery Tip | PTFE |
| Compliance | H-certified (German Metrology Institute), DIN EN ISO 9001, DIN EN ISO 8655-3, GLP/GMP-ready |
| Brand | FORTUNA |
|---|---|
| Origin | Germany |
| Model | FORTUNA® OPTIFIX® SOLVENT |
| Dispensing Range | 0.4–500 mL |
| Minimum Graduation | 0.1 mL |
| Accuracy | ±0.1 mL |
| Relative Error | ±1% |
| Actuation | Manual |
| Volumetric Cylinder Material | Borosilicate Glass |
| Piston Sealing | PTFE-coated |
| Adapter Material (BASIC/SOLVENT) | Polypropylene (PP), GL40 & GL45 Thread |
| Delivery Tube | PTFE |
| Compliance | ISO 8536-4, DIN EN ISO 8655-3, GLP-ready design |