Empowering Scientific Discovery

LUMEX INSTRUMENTS (Lumex Analytical Instruments)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelPyro-915+
Instrument TypePortable
PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman Background Correction
Detection Limit0.05 ng/mL (liquid) / 0.05 µg/kg (solid)
Repeatability±2% RSD
Linearity Error±1%
Sample Throughput<2 min per sample
Operating Temperature RangeProgrammable up to 950 °C
Air Monitoring LOD0.5 ng/m³ (10-s response) / 2 ng/m³ (1-s response)
Power Supply100–240 VAC, 50/60 Hz
Power Consumption700 W
Weight17.5 kg
Dimensions (Controller)400 × 280 × 135 mm
Dimensions (Furnace)430 × 340 × 135 mm
Continuous OperationUp to 8 h
Carrier Gas Flow1.0–3.0 L/min
Sample Mass Range10–1500 mg
Upper Detection Limit200 mg/kg (based on 20 mg sample)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelRA-915F
Instrument TypePortable
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition
Detection Limit0.005 ng Hg
Repeatability±1% RSD
Linearity Error±1%
Detection Range5 orders of magnitude
Sample Throughput1–5 min per analysis
Power Supply220 VAC, 50 Hz (with optional DC/vehicle power adapter)
Dimensions (Analyzer Unit)300 × 260 × 130 mm
Weight (Analyzer Unit)4.0 kg
Dimensions (Thermal Decomposer Module)350 × 260 × 120 mm
Weight (Thermal Decomposer Module)7.5 kg
Dimensions (Power Supply Unit)380 × 260 × 130 mm
Weight (Power Supply Unit)10.0 kg
Sample Mass Range10–500 mg
Liquid Detection Limit0.5 µg/L
Solid Upper Quantitation Limit200 mg/kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRP-91NG
Instrument TypePortable
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Frequency Zeeman Modulation (ZAAS-HFM)
Detection Limit1 ng/m³
Repeatability±1% RSD
Linearity Error±1%
Concentration Range0.5–20,000 ng/m³ (optional high- and ultra-high-concentration modes available)
Air Pump Flow Rate2–5 L/min
Operating Ambient Temperature1–40 °C
Atmospheric Pressure Range84.0–106.7 kPa
Relative Humidity>95% at 35 °C
Power Supply100–240 VAC, 50/60 Hz
Power Consumption35 W
Internal Battery Runtime8 h
Dimensions320 × 290 × 160 mm
Weight6.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelRA-915AM
Instrument TypeOnline Analyzer
Measurement PrincipleZeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM)
Detection Limit0.5 ng/m³
Repeatability±1%
Linearity Error±2%
Gas Flow Rate3–10 L/min
Response Time10–300 s
Range I0.5–2000 ng/m³
Range II100–400,000 ng/m³
Operating Temperature−20 to +50 °C
Pressure Range84–106.7 kPa
Relative Humidity<99% at 35 °C
Power Supply240 VAC, 50/60 Hz
Power Consumption120 W
Dimensions600 × 480 × 220 mm
Weight19 kg
Communication InterfacesRS-232, Dual USB, LAN, Isolated 4–20 mA Output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelRA-915Lab
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Repeatability<1.5% RSD
Linearity Error±5%
Sample ThroughputUp to 45 samples unattended
Analysis Time≤3 minutes per sample
Linear Range0–2,000,000 µg/kg (ppb–ppm equivalent across matrices)
Detection CapabilitySub-ng absolute sensitivity (matrix-dependent)
ComplianceEPA Method 7473, EPA 1631, EPA 30B, EPA SW-846
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelFluorat-02-Panaroma
Wavelength Range (Excitation)210–840 nm
Wavelength Range (Emission)210–690 nm (up to 840 nm optional)
Spectral Resolution<8 nm (15 nm optional)
Wavelength Accuracy<3 nm
Signal-to-Noise Ratio>100 (up to 200)
Slit Width (Spectral Bandpass)1.5 nm
Sensitivity>200:1
DetectorPMT
Light SourcePulsed Xenon Lamp
Cuvette Volume0.01–3 mL
Dimensions400 × 355 × 150 mm
Weight13 kg
Power Supply110/220 V, 50/60 Hz, 60 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelMGA-1000
Instrument TypeGraphite Furnace AAS
MonochromatorConcave Grating (1800 lines/mm)
Optical SystemQuasi-Dual-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionZeeman Effect (50 kHz)
Spectral Resolution0.3 nm
Sensitivity0.3 A
RSD (Repeatability)≤0.3%
Detection Limit (Cu)<0.006 µg/L
Max Graphite Furnace Temperature3000 °C
Heating RateUp to 7000 °C/s
Argon Flow Rate<1 L/min (high-purity)
Wavelength Range185–900 nm
Typical LODsPb ≤0.05 µg/L, Cr ≤0.01 µg/L
Dimensions800 × 475 × 310 mm
Weight50 kg
Power Supply380 VAC, 50 Hz (3-phase)
CoolingIntegrated Closed-Loop Recirculating Water System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelRA-915W
Instrument TypePortable
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Frequency Zeeman Background Correction (ZAAS-HFM)
Detection Limit0.5 ng/L
Repeatability±1% RSD
Linearity Error±1%
ComplianceEPA Method 1631, EPA SW-846, EN 1483 & EN 13806, HJ 543–2009, HJ 597–2011, GB 3838–2002, GB 5009.17–2014, WS/T 25–1996, GB/T 15555.1–1995, GB/T 17136–1997
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelRA-915M Series
Instrument TypePortable
PrincipleZeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM)
Detection Limit0.5 ng/m³ (10 s), 2 ng/m³ (1 s)
Repeatability<2% RSD
Linearity Error±5%
Measurement Range0.5–200,000 ng/m³
Zero Signal SD<2 ng/m³
5-min Zero Drift<2 ng/m³
Warm-up Time<20 min
Air Pump Flow Rate>10 L/min
Power SupplyInternal 12 V DC battery (8 h continuous operation) or 110/220 V AC, 50/60 Hz
Dimensions460 × 110 × 220 mm
Weight7 kg
Power Consumption40 W
ComplianceEPA Method 1631, EPA SW-846 7473 & 30B, ASTM D7622-10, EN 1483 / 13806 / 15852, GB 7468-87
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelRA-915S
Instrument TypePortable
PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman-effect background correction
Detection Limit0.01 µg/kg
Repeatability≤1% RSD
Linearity Error≤1%
Sample IntroductionDirect thermal decomposition (10–1500 mg solid/liquid)
Analysis Time1–2 min per sample
Dynamic Range5 orders of magnitude
Wavelength254 nm (Hg resonance line)
Power Supply198–242 VAC, 50 ± 1 Hz
Dimensions (Detector Unit)470 × 210 × 110 mm
Integrated Air PumpYes
Onboard CalibrationCertified Hg standard traceable to NIST
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelRP-92 Liquid Mercury
Instrument TypePortable
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Sample Volume0.5–20 mL
Air Pump Flow Rate0.8–4.2 L/min
Power Supply100–240 VAC, 50/60 Hz
Power Consumption40 W
Pump Unit Net Weight3.0 kg
Pump Unit Dimensions360 × 225 × 125 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRA-915AMNG
Instrument TypeOnline Analyzer
PrincipleZeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM)
Detection Limit0.5 ng/m³
Repeatability±1%
Linearity Error±1%
Measurement Range0–2000 ng/m³ (configurable multi-range options available)
Reporting Interval≥2 s (user-definable)
Benzene CorrectionFully Automatic
Zero Drift CorrectionUser-selectable (recommended every 60 min)
Span Drift CorrectionUser-selectable (recommended every 3 h)
CalibrationFully Automated (calibration source ≈12,000 ng/m³ Hg)
Sample Flow Rate7–10 L/min
Communication ProtocolStandard Bavarian Protocol (customizable upon request)
Status OutputsSERVICE (zero/calibration mode), FAILURE, MEASURE (Bavarian)
Operating Temperature14–40 °C
Atmospheric Pressure84–106.7 kPa
Relative Humidity<99% at 35 °C
Power Supply220–240 VAC, 50 Hz
Dimensions600 × 480 × 220 mm
Weight19 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelFT-08
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range8000–350 cm⁻¹
Resolution0.25–64 cm⁻¹ (selectable)
Scan Speed0.8 s at 16 cm⁻¹
SNR>75,000 (4 cm⁻¹, 1 min, 2150±50 cm⁻¹)
Wavenumber Accuracy±0.05 cm⁻¹
DetectorHigh-Sensitivity DLATGS
BeamsplitterKBr-coated Ge (8000–350 cm⁻¹), hermetically sealed and desiccated
InterferometerPatented Suspended Double Cat’s Eye Design
Light SourceHigh-Stability Ceramic IR Emitter
Power Consumption65 W
Dimensions580 × 550 × 340 mm
Weight32 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory
ModelInfraLUM FT-12
Wavelength Range760–1150 nm
Spectral Resolution8 / 16 / 32 / 64 cm⁻¹
Sampling ModeDiffuse Reflectance / Transmission
Data Acquisition Interval1 cm⁻¹
Scan Speed1 spectrum per second
Sample Volume50 mL
Analysis Time≤90 s
Dimensions530 × 450 × 380 mm
Weight32 kg
Power Supply220 V AC, 50 Hz
Power Consumption110 W
Chemometrics SoftwareRIM (with PARCLE integration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelUMA
Instrument TypePortable Mercury Analyzer
PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman Background Correction
Detection Limit1 ppb
Repeatability<1% RSD
Linearity Error±1%
Sample ThroughputSolid/Liquid analysis completed in ≤60 s
Gas Response Time1 s
Dynamic Range6 orders of magnitude
Power Supply100–240 VAC, 50/60 Hz or internal battery (8 h continuous operation)
Dimensions (Control Unit)400 × 280 × 135 mm
Dimensions (Thermal Decomposer Module)430 × 340 × 135 mm
Weight17.5 kg
Air Pump Flow Rate0.8–4.2 L/min
Liquid Sample Volume (CV Mode)0.5–20 mL
Solid Sample Mass (Thermal Decomposition)5–300 mg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelMGA-915MD
Instrument TypeGraphite Furnace AAS
MonochromatorConcave Grating (1800 lines/mm)
Optical SystemDual-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionZeeman Effect
Spectral Resolution0.3 nm
Sensitivity0.3 A (for Cu at 324.8 nm)
RSD (Repeatability)<0.3%
Detection Limit (Cu)<0.006 mg/L
Detection Limits (Typical)Pb ≤ 0.05 µg/L, Cr ≤ 0.01 µg/L
Max Graphite Furnace Temperature2950 °C
Max Heating Rate7000 K/s
Argon Flow Rate (Ultra-High Purity)<1 L/min
Wavelength Range190–900 nm
Dimensions800 × 570 × 390 mm
Weight75 kg
Power Supply380 V AC, 50 Hz (3-phase)
CoolingClosed-Loop Recirculating Water System
Power Consumption<0.2 kW (standby/analysis), <18 kW (atomization/cleaning)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelInfraLUM FT-12 Industrial
Instrument TypeLaboratory
PrincipleFourier Transform (FT) NIR
Wavelength Range760–1150 nm
Measurement ModeTransmission
Chemometrics SoftwareParcel
Sample CompatibilityLiquid, semi-solid, and homogeneous solid samples in transmission cells
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelLS-915
Instrument TypeBenchtop Laboratory System
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit1 pg Hg
Repeatability≤1% RSD
Linearity Error≤2%
Sample Capacity75 positions
Solid Sample Mass≥1000 mg
Liquid Sample Volume≥500 µL
Robotic ArchitectureCartesian XYZ Coordinate System
Crucible MaterialHigh-Purity Quartz (operable up to >1000 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelLight 915
Instrument TypePortable
Measurement PrincipleZeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM)
Detection Limit100 ng/m³
Repeatability±1% RSD
Linearity Error±1%
Measurement Range0.1–3000 µg/m³
Air Pump Flow Rate10 L/min
Analysis TimeReal-time
Dimensions290 × 210 × 110 mm
Weight3.3 kg
Power SupplyInternal 12 V DC rechargeable battery (12 h operation) / External 110–240 V AC, 50/60 Hz
Power Consumption20 W
Data StorageInternal memory with USB and Bluetooth connectivity
ComplianceEPA Emergency Response Equipment List, ASTM D6784-22 (for mercury in air), ISO 6978-1:2003 (natural gas—mercury determination)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Country of AssemblyChina
ModelCapel-105
Instrument TypeCapillary Electrophoresis (CE) System
Sample AnalysisInorganic Ions, Small Molecules, Biomolecules
Operating Voltage1–25 kV (1 kV step increment, polarity auto-switching)
DetectionUV Absorbance (190–380 nm)
Light SourceHigh-Intensity Deuterium Lamp
Injection ModePressure or Electrokinetic
Pressure Range0–99 mbar (step resolution: 1 mbar)
Electrokinetic Injection Voltage1–25 kV (1 kV step)
Capillary CoolingLiquid-Cooled Thermostatic System
Temperature Control Range–10 °C to +30 °C (±0.1 °C stability)
Capillary Dimensions30–100 cm length × 50/75/100 µm ID
Current Range0–200 µA
Flushing Pressure0–1000 / 2000 mbar
Power Consumption200 W
Dimensions500 × 500 × 500 mm
Weight25 kg
ComplianceDesigned for GLP-compliant laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelCapel-105M
CE Instrument TypeCapillary Electrophoresis (CE)
Voltage Range±1–25 kV (1 kV step, polarity auto-switching)
Detection Wavelength190–400 nm
Light SourceHigh-intensity deuterium lamp
Pressure Range0–99 mbar (1 mbar step)
Capillary Flushing Pressure1000–2000 mbar (1 mbar step)
Capillary Dimensions30–120 cm length × 50 or 75 µm ID
Temperature ControlWater-cooled thermostating, –10 to +30 °C (±0.1 °C stability)
Sample IntroductionFully automated 20-position sampler (10 inlet + 10 outlet positions), electrokinetic & pressure-driven injection
Current Monitoring0–200 µA
Power Supply110/220 VAC, 50/60 Hz, 200 W
Dimensions500 × 500 × 500 mm
Weight25 kg
SoftwareElforun PC-based control and data analysis suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelCapel 205
CE Instrument TypeCapillary Electrophoresis (CE)
Voltage Range±1–25 kV (extendable to ±30 kV)
Pressure Range±1–2000 mbar
DetectionUV-Vis (190–600 nm, Xenon lamp, ±1 nm accuracy)
Capillary Temperature ControlLiquid-cooled, -10 °C to +65 °C (±0.1 °C stability)
Injection ModesVoltage, Pressure, Vacuum
Autosampler59-position, Eppendorf 2 mL vials, sealed cap removal
Cooling SystemIntegrated liquid-cooled恒温 water jacket
Power110/220 VAC, 50/60 Hz, 170 W
Dimensions470 × 530 × 410 mm
Weight30 kg
SoftwareElforun-205 (PC-based, GLP-compliant audit trail, method library, customizable reporting, spectral scanning)
Show next