| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Pyro-915+ |
| Instrument Type | Portable |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman Background Correction |
| Detection Limit | 0.05 ng/mL (liquid) / 0.05 µg/kg (solid) |
| Repeatability | ±2% RSD |
| Linearity Error | ±1% |
| Sample Throughput | <2 min per sample |
| Operating Temperature Range | Programmable up to 950 °C |
| Air Monitoring LOD | 0.5 ng/m³ (10-s response) / 2 ng/m³ (1-s response) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 700 W |
| Weight | 17.5 kg |
| Dimensions (Controller) | 400 × 280 × 135 mm |
| Dimensions (Furnace) | 430 × 340 × 135 mm |
| Continuous Operation | Up to 8 h |
| Carrier Gas Flow | 1.0–3.0 L/min |
| Sample Mass Range | 10–1500 mg |
| Upper Detection Limit | 200 mg/kg (based on 20 mg sample) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915F |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition |
| Detection Limit | 0.005 ng Hg |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Detection Range | 5 orders of magnitude |
| Sample Throughput | 1–5 min per analysis |
| Power Supply | 220 VAC, 50 Hz (with optional DC/vehicle power adapter) |
| Dimensions (Analyzer Unit) | 300 × 260 × 130 mm |
| Weight (Analyzer Unit) | 4.0 kg |
| Dimensions (Thermal Decomposer Module) | 350 × 260 × 120 mm |
| Weight (Thermal Decomposer Module) | 7.5 kg |
| Dimensions (Power Supply Unit) | 380 × 260 × 130 mm |
| Weight (Power Supply Unit) | 10.0 kg |
| Sample Mass Range | 10–500 mg |
| Liquid Detection Limit | 0.5 µg/L |
| Solid Upper Quantitation Limit | 200 mg/kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RP-91NG |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Frequency Zeeman Modulation (ZAAS-HFM) |
| Detection Limit | 1 ng/m³ |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Concentration Range | 0.5–20,000 ng/m³ (optional high- and ultra-high-concentration modes available) |
| Air Pump Flow Rate | 2–5 L/min |
| Operating Ambient Temperature | 1–40 °C |
| Atmospheric Pressure Range | 84.0–106.7 kPa |
| Relative Humidity | >95% at 35 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 35 W |
| Internal Battery Runtime | 8 h |
| Dimensions | 320 × 290 × 160 mm |
| Weight | 6.5 kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ |
| Repeatability | ±1% |
| Linearity Error | ±2% |
| Gas Flow Rate | 3–10 L/min |
| Response Time | 10–300 s |
| Range I | 0.5–2000 ng/m³ |
| Range II | 100–400,000 ng/m³ |
| Operating Temperature | −20 to +50 °C |
| Pressure Range | 84–106.7 kPa |
| Relative Humidity | <99% at 35 °C |
| Power Supply | 240 VAC, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 600 × 480 × 220 mm |
| Weight | 19 kg |
| Communication Interfaces | RS-232, Dual USB, LAN, Isolated 4–20 mA Output |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915Lab |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Repeatability | <1.5% RSD |
| Linearity Error | ±5% |
| Sample Throughput | Up to 45 samples unattended |
| Analysis Time | ≤3 minutes per sample |
| Linear Range | 0–2,000,000 µg/kg (ppb–ppm equivalent across matrices) |
| Detection Capability | Sub-ng absolute sensitivity (matrix-dependent) |
| Compliance | EPA Method 7473, EPA 1631, EPA 30B, EPA SW-846 |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-Panaroma |
| Wavelength Range (Excitation) | 210–840 nm |
| Wavelength Range (Emission) | 210–690 nm (up to 840 nm optional) |
| Spectral Resolution | <8 nm (15 nm optional) |
| Wavelength Accuracy | <3 nm |
| Signal-to-Noise Ratio | >100 (up to 200) |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Sensitivity | >200:1 |
| Detector | PMT |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Volume | 0.01–3 mL |
| Dimensions | 400 × 355 × 150 mm |
| Weight | 13 kg |
| Power Supply | 110/220 V, 50/60 Hz, 60 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-1000 |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Quasi-Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect (50 kHz) |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A |
| RSD (Repeatability) | ≤0.3% |
| Detection Limit (Cu) | <0.006 µg/L |
| Max Graphite Furnace Temperature | 3000 °C |
| Heating Rate | Up to 7000 °C/s |
| Argon Flow Rate | <1 L/min (high-purity) |
| Wavelength Range | 185–900 nm |
| Typical LODs | Pb ≤0.05 µg/L, Cr ≤0.01 µg/L |
| Dimensions | 800 × 475 × 310 mm |
| Weight | 50 kg |
| Power Supply | 380 VAC, 50 Hz (3-phase) |
| Cooling | Integrated Closed-Loop Recirculating Water System |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915W |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Frequency Zeeman Background Correction (ZAAS-HFM) |
| Detection Limit | 0.5 ng/L |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Compliance | EPA Method 1631, EPA SW-846, EN 1483 & EN 13806, HJ 543–2009, HJ 597–2011, GB 3838–2002, GB 5009.17–2014, WS/T 25–1996, GB/T 15555.1–1995, GB/T 17136–1997 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915M Series |
| Instrument Type | Portable |
| Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ (10 s), 2 ng/m³ (1 s) |
| Repeatability | <2% RSD |
| Linearity Error | ±5% |
| Measurement Range | 0.5–200,000 ng/m³ |
| Zero Signal SD | <2 ng/m³ |
| 5-min Zero Drift | <2 ng/m³ |
| Warm-up Time | <20 min |
| Air Pump Flow Rate | >10 L/min |
| Power Supply | Internal 12 V DC battery (8 h continuous operation) or 110/220 V AC, 50/60 Hz |
| Dimensions | 460 × 110 × 220 mm |
| Weight | 7 kg |
| Power Consumption | 40 W |
| Compliance | EPA Method 1631, EPA SW-846 7473 & 30B, ASTM D7622-10, EN 1483 / 13806 / 15852, GB 7468-87 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915S |
| Instrument Type | Portable |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman-effect background correction |
| Detection Limit | 0.01 µg/kg |
| Repeatability | ≤1% RSD |
| Linearity Error | ≤1% |
| Sample Introduction | Direct thermal decomposition (10–1500 mg solid/liquid) |
| Analysis Time | 1–2 min per sample |
| Dynamic Range | 5 orders of magnitude |
| Wavelength | 254 nm (Hg resonance line) |
| Power Supply | 198–242 VAC, 50 ± 1 Hz |
| Dimensions (Detector Unit) | 470 × 210 × 110 mm |
| Integrated Air Pump | Yes |
| Onboard Calibration | Certified Hg standard traceable to NIST |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RP-92 Liquid Mercury |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Volume | 0.5–20 mL |
| Air Pump Flow Rate | 0.8–4.2 L/min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 40 W |
| Pump Unit Net Weight | 3.0 kg |
| Pump Unit Dimensions | 360 × 225 × 125 mm |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RA-915AMNG |
| Instrument Type | Online Analyzer |
| Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ |
| Repeatability | ±1% |
| Linearity Error | ±1% |
| Measurement Range | 0–2000 ng/m³ (configurable multi-range options available) |
| Reporting Interval | ≥2 s (user-definable) |
| Benzene Correction | Fully Automatic |
| Zero Drift Correction | User-selectable (recommended every 60 min) |
| Span Drift Correction | User-selectable (recommended every 3 h) |
| Calibration | Fully Automated (calibration source ≈12,000 ng/m³ Hg) |
| Sample Flow Rate | 7–10 L/min |
| Communication Protocol | Standard Bavarian Protocol (customizable upon request) |
| Status Outputs | SERVICE (zero/calibration mode), FAILURE, MEASURE (Bavarian) |
| Operating Temperature | 14–40 °C |
| Atmospheric Pressure | 84–106.7 kPa |
| Relative Humidity | <99% at 35 °C |
| Power Supply | 220–240 VAC, 50 Hz |
| Dimensions | 600 × 480 × 220 mm |
| Weight | 19 kg |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | FT-08 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 8000–350 cm⁻¹ |
| Resolution | 0.25–64 cm⁻¹ (selectable) |
| Scan Speed | 0.8 s at 16 cm⁻¹ |
| SNR | >75,000 (4 cm⁻¹, 1 min, 2150±50 cm⁻¹) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Detector | High-Sensitivity DLATGS |
| Beamsplitter | KBr-coated Ge (8000–350 cm⁻¹), hermetically sealed and desiccated |
| Interferometer | Patented Suspended Double Cat’s Eye Design |
| Light Source | High-Stability Ceramic IR Emitter |
| Power Consumption | 65 W |
| Dimensions | 580 × 550 × 340 mm |
| Weight | 32 kg |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Model | InfraLUM FT-12 |
| Wavelength Range | 760–1150 nm |
| Spectral Resolution | 8 / 16 / 32 / 64 cm⁻¹ |
| Sampling Mode | Diffuse Reflectance / Transmission |
| Data Acquisition Interval | 1 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Sample Volume | 50 mL |
| Analysis Time | ≤90 s |
| Dimensions | 530 × 450 × 380 mm |
| Weight | 32 kg |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 110 W |
| Chemometrics Software | RIM (with PARCLE integration) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | UMA |
| Instrument Type | Portable Mercury Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman Background Correction |
| Detection Limit | 1 ppb |
| Repeatability | <1% RSD |
| Linearity Error | ±1% |
| Sample Throughput | Solid/Liquid analysis completed in ≤60 s |
| Gas Response Time | 1 s |
| Dynamic Range | 6 orders of magnitude |
| Power Supply | 100–240 VAC, 50/60 Hz or internal battery (8 h continuous operation) |
| Dimensions (Control Unit) | 400 × 280 × 135 mm |
| Dimensions (Thermal Decomposer Module) | 430 × 340 × 135 mm |
| Weight | 17.5 kg |
| Air Pump Flow Rate | 0.8–4.2 L/min |
| Liquid Sample Volume (CV Mode) | 0.5–20 mL |
| Solid Sample Mass (Thermal Decomposition) | 5–300 mg |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-915MD |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A (for Cu at 324.8 nm) |
| RSD (Repeatability) | <0.3% |
| Detection Limit (Cu) | <0.006 mg/L |
| Detection Limits (Typical) | Pb ≤ 0.05 µg/L, Cr ≤ 0.01 µg/L |
| Max Graphite Furnace Temperature | 2950 °C |
| Max Heating Rate | 7000 K/s |
| Argon Flow Rate (Ultra-High Purity) | <1 L/min |
| Wavelength Range | 190–900 nm |
| Dimensions | 800 × 570 × 390 mm |
| Weight | 75 kg |
| Power Supply | 380 V AC, 50 Hz (3-phase) |
| Cooling | Closed-Loop Recirculating Water System |
| Power Consumption | <0.2 kW (standby/analysis), <18 kW (atomization/cleaning) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | InfraLUM FT-12 Industrial |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) NIR |
| Wavelength Range | 760–1150 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Parcel |
| Sample Compatibility | Liquid, semi-solid, and homogeneous solid samples in transmission cells |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | LS-915 |
| Instrument Type | Benchtop Laboratory System |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 1 pg Hg |
| Repeatability | ≤1% RSD |
| Linearity Error | ≤2% |
| Sample Capacity | 75 positions |
| Solid Sample Mass | ≥1000 mg |
| Liquid Sample Volume | ≥500 µL |
| Robotic Architecture | Cartesian XYZ Coordinate System |
| Crucible Material | High-Purity Quartz (operable up to >1000 °C) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Light 915 |
| Instrument Type | Portable |
| Measurement Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 100 ng/m³ |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Measurement Range | 0.1–3000 µg/m³ |
| Air Pump Flow Rate | 10 L/min |
| Analysis Time | Real-time |
| Dimensions | 290 × 210 × 110 mm |
| Weight | 3.3 kg |
| Power Supply | Internal 12 V DC rechargeable battery (12 h operation) / External 110–240 V AC, 50/60 Hz |
| Power Consumption | 20 W |
| Data Storage | Internal memory with USB and Bluetooth connectivity |
| Compliance | EPA Emergency Response Equipment List, ASTM D6784-22 (for mercury in air), ISO 6978-1:2003 (natural gas—mercury determination) |
| Brand | LUMEX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | Capel-105 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Analysis | Inorganic Ions, Small Molecules, Biomolecules |
| Operating Voltage | 1–25 kV (1 kV step increment, polarity auto-switching) |
| Detection | UV Absorbance (190–380 nm) |
| Light Source | High-Intensity Deuterium Lamp |
| Injection Mode | Pressure or Electrokinetic |
| Pressure Range | 0–99 mbar (step resolution: 1 mbar) |
| Electrokinetic Injection Voltage | 1–25 kV (1 kV step) |
| Capillary Cooling | Liquid-Cooled Thermostatic System |
| Temperature Control Range | –10 °C to +30 °C (±0.1 °C stability) |
| Capillary Dimensions | 30–100 cm length × 50/75/100 µm ID |
| Current Range | 0–200 µA |
| Flushing Pressure | 0–1000 / 2000 mbar |
| Power Consumption | 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Capel-105M |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (1 kV step, polarity auto-switching) |
| Detection Wavelength | 190–400 nm |
| Light Source | High-intensity deuterium lamp |
| Pressure Range | 0–99 mbar (1 mbar step) |
| Capillary Flushing Pressure | 1000–2000 mbar (1 mbar step) |
| Capillary Dimensions | 30–120 cm length × 50 or 75 µm ID |
| Temperature Control | Water-cooled thermostating, –10 to +30 °C (±0.1 °C stability) |
| Sample Introduction | Fully automated 20-position sampler (10 inlet + 10 outlet positions), electrokinetic & pressure-driven injection |
| Current Monitoring | 0–200 µA |
| Power Supply | 110/220 VAC, 50/60 Hz, 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Software | Elforun PC-based control and data analysis suite |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Capel 205 |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (extendable to ±30 kV) |
| Pressure Range | ±1–2000 mbar |
| Detection | UV-Vis (190–600 nm, Xenon lamp, ±1 nm accuracy) |
| Capillary Temperature Control | Liquid-cooled, -10 °C to +65 °C (±0.1 °C stability) |
| Injection Modes | Voltage, Pressure, Vacuum |
| Autosampler | 59-position, Eppendorf 2 mL vials, sealed cap removal |
| Cooling System | Integrated liquid-cooled恒温 water jacket |
| Power | 110/220 VAC, 50/60 Hz, 170 W |
| Dimensions | 470 × 530 × 410 mm |
| Weight | 30 kg |
| Software | Elforun-205 (PC-based, GLP-compliant audit trail, method library, customizable reporting, spectral scanning) |