LUMEX INSTRUMENTS (Lumex Analytical Instruments)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAKMC-1
Price RangeUSD 13,500 – 40,500
Measurement PrinciplePotentiometric Titration
Detection Range0.25–250 ppm (as CaCO₃)
Sampling Frequency1–4 times/hour
Operating Temperature+10 to +35 °C
Relative Humidity (at +25 °C)<80%
Sample Pressure0.1–10 atm
Sample Temperature+5 to +40 °C
Power Supply110/220 VAC, 50/60 Hz
Power Consumption100 W
Dimensions300 × 400 × 150 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelFLUORAT-02
Instrument TypePortable/Handheld Water Quality Analyzer
Detection MethodsFluorometry, Photometry, Chemiluminescence
Measured ParametersOil in Water, Volatile Phenols, Anionic Surfactants, COD, Turbidity, Cyanide, Uranium, Vanadium, Molybdenum, Nickel, Manganese, Chromium
Spectral Range250–900 nm
Cuvette Pathlengths10, 20, and 40 mm
Power Supply200–240 VAC, 50 Hz
Dimensions305 × 320 × 110 mm
Weight6.5 kg
Power Consumption36 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelCRAB
TypeOnline Oil Film Monitoring System
Measurement Range0–111 mg/L (as mineral oil, typical calibration)
Detection Limit0.2 mg/L
Accuracy±1 mg/L
Resolution0.1 mg/L
Measurement Frequency1 Hz
Minimum Detectable Oil Film Thickness≥0.5 µm
Maximum Sensor-to-Water Distance25 m
Maximum Communication Distance (RS485)300 m
Operating Temperature−10 to +50 °C
Relative HumidityUp to 100%
Power Supply187–242 VAC, 50 Hz
Power Consumption20 W
Dimensions160 × 160 × 110 mm
Weight2 kg
Optical Field Tilt Tolerance±20°
Communication InterfacesRS232, RS485
Alarm OutputRelay + Visual/Audible Alert
Mounting OptionsFixed, pendant, angled, or UAV-integrated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelFluorat-02-5M
Instrument TypePortable
Measurement PrincipleUV Spectrophotometry & Fluorescence Detection
Detection Limit0.2 mg/L
Accuracy±1%
Resolution0.01 mg/L
Measurement Frequency2 samples/min
Spectral Range250–900 nm
Cuvette Pathlengths10, 20, and 40 mm
Power Supply200–240 VAC, 50 Hz
Dimensions305 × 320 × 110 mm
Weight6.5 kg
Power Consumption36 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginRussia
ModelFluorat-AE-2
Instrument TypeOnline
Measurement PrincipleUV Fluorescence with Patented Signal Separation Technology
Measurement Range0.001–500 mg/L
Detection Limit0.01 mg/L
Accuracy<2%
Resolution0.1 mg/L
Measurement Frequency8 samples/hour
Sample InputUp to 10 parallel aqueous streams
Power Supply187–242 VAC, 50 ±1 Hz / 12 VDC
Power Consumption100 W
Dimensions500 × 660 × 200 mm
Weight50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
ModelFLUORAT® AA-2
OriginRussia
Detection Range0.04–2 mg/L Al
Operating Temperature+5 to +50 °C
Sample Flow Pressure0.1–10 atm
Cycle Time10–30 min
Output InterfacesRS-485, RS-232, 4–20 mA (0–20 mA)
Power Supply187–242 V, 50 Hz ±1%, 12 V DC
Power Consumption100 W
Dimensions600 × 600 × 250 mm
Weight≤ 50 kg
MTBF≥ 10,000 h
IP RatingDust-protected and splash-resistant
CompliancePND F 14.1:2.4.181-02, PND F 14.1:4.1.1255-03
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
ModelRA-915WM
PrincipleHigh-Temperature Thermal Decomposition Coupled with Zeeman Atomic Absorption Detection
Detection Limit0.3 µg/L
Measurement Range0–200 µg/L
Analysis FrequencyOnce every 0.5–3 hours
CalibrationFully Automatic
Baseline VerificationFully Automatic
Max. Dissolved Solids Tolerance1000 mg/L
Communication InterfacesRS-232/485, LAN, Isolated 4–20 mA
ProtocolsModbus, GESYTEC
Output RelaysOpen/Closed
Operating Temperature5–40 °C
Atmospheric Pressure Range84–106.7 kPa
Relative Humidity<98% at +35 °C
Power Supply110/240 VAC, 50/60 Hz
Dimensions (L×W×H)1000 × 400 × 2000 mm