BrandLUMEX
OriginUSA
ModelIRM-915
Detection PrincipleZeeman-effect Background-Corrected Cold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Temperature Dry Catalytic Conversion
Measurement Range0.05–1000 µg/m³ (wet basis, HgT and Hg⁰)
Zero Drift±2.5%
Precision±2.5%
Accuracy±5%
Conversion Temperature700–750 °C
Dilution RatioUp to 1:100
Sample FlowHeated probe + heated filter + dilution/conversion module
Power Requirement220 V, 1000 W
Compressed Air15–20 L/min at 80 psig
Data OutputReal-time acquisition
System Weight67 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelOLM30B Sampler
Sampling Flow Rate1 L/min
Flow Accuracy±1% of full scale
Sampling TemperatureUp to 150 °C
Sample TargetElemental and Oxidized Mercury (Hg⁰, Hg²⁺)
Flow Resolution0.01 L/min
Repeatability±1% FS
Max Flow Rate2 L/min
Power Supply110/220 V AC
Power Consumption500 W
Operating Temperature Range–10 °C to 50 °C
WeightAir Pump Unit 6.8 kg, Probe 14 kg
ComplianceEPA Method 30B, 40 CFR Part 60, ASTM D6784-22
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginCanada
ModelBA-15
Detection PrincipleAtomic Absorption Spectrometry with High-Frequency Zeeman Background Correction
Measurement Range0.1 ng/m³ – 10,000 mg/m³
Response Time1 sec (real-time) – 5 min (integrated mode)
Zero Drift CompensationAutomatic
Sample Flow Rate7–10 L/min
Dimensions470 × 110 × 210 mm
Weight7 kg (15.4 lb)
Power Supply90–240 VAC, 50/60 Hz or 12 VDC
Power Consumption40 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUMEX
OriginUSA
ModelOLM915J
Detection PrincipleHigh-Temperature Catalytic Conversion + Zeeman-Background-Corrected Atomic Absorption Spectrometry (AAS)
Measurement Range0.1–100 µg/m³
Response Time≤30 seconds per reading
ComplianceEPA Method PS 12A (Level 3 Certified)
Sample HandlingHot-wet extraction with heated sampling probe (10–50 ft customizable), Ni-based alloy filter/dilution module, dry catalytic conversion at 750 °C
Enclosure RatingNEMA 4X
Operating Ambient Temperature–10 to 50 °C
Power Requirement110/220 VAC, 2000 W
Compressed Air SupplyDry, dew point ≤ –40 °C
CalibrationIntegrated elemental Hg vapor generator, fully automated, no external standards required
Data OutputReal-time Ethernet (Modbus TCP/IP, OPC UA), Excel export via embedded industrial PC, ESC8832-compatible