| Brand | LUMEX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | Capel-105 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Analysis | Inorganic Ions, Small Molecules, Biomolecules |
| Operating Voltage | 1–25 kV (1 kV step increment, polarity auto-switching) |
| Detection | UV Absorbance (190–380 nm) |
| Light Source | High-Intensity Deuterium Lamp |
| Injection Mode | Pressure or Electrokinetic |
| Pressure Range | 0–99 mbar (step resolution: 1 mbar) |
| Electrokinetic Injection Voltage | 1–25 kV (1 kV step) |
| Capillary Cooling | Liquid-Cooled Thermostatic System |
| Temperature Control Range | –10 °C to +30 °C (±0.1 °C stability) |
| Capillary Dimensions | 30–100 cm length × 50/75/100 µm ID |
| Current Range | 0–200 µA |
| Flushing Pressure | 0–1000 / 2000 mbar |
| Power Consumption | 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Capel-105M |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (1 kV step, polarity auto-switching) |
| Detection Wavelength | 190–400 nm |
| Light Source | High-intensity deuterium lamp |
| Pressure Range | 0–99 mbar (1 mbar step) |
| Capillary Flushing Pressure | 1000–2000 mbar (1 mbar step) |
| Capillary Dimensions | 30–120 cm length × 50 or 75 µm ID |
| Temperature Control | Water-cooled thermostating, –10 to +30 °C (±0.1 °C stability) |
| Sample Introduction | Fully automated 20-position sampler (10 inlet + 10 outlet positions), electrokinetic & pressure-driven injection |
| Current Monitoring | 0–200 µA |
| Power Supply | 110/220 VAC, 50/60 Hz, 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Software | Elforun PC-based control and data analysis suite |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Capel 205 |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (extendable to ±30 kV) |
| Pressure Range | ±1–2000 mbar |
| Detection | UV-Vis (190–600 nm, Xenon lamp, ±1 nm accuracy) |
| Capillary Temperature Control | Liquid-cooled, -10 °C to +65 °C (±0.1 °C stability) |
| Injection Modes | Voltage, Pressure, Vacuum |
| Autosampler | 59-position, Eppendorf 2 mL vials, sealed cap removal |
| Cooling System | Integrated liquid-cooled恒温 water jacket |
| Power | 110/220 VAC, 50/60 Hz, 170 W |
| Dimensions | 470 × 530 × 410 mm |
| Weight | 30 kg |
| Software | Elforun-205 (PC-based, GLP-compliant audit trail, method library, customizable reporting, spectral scanning) |