Measurement Instruments
Filter
Showing 1111–1140 of 1342 results
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | Driptych |
| Type | Acoustic Drip Counter |
| Power | Lithium Thionyl Chloride 1/2 AA 3.6 V |
| Dimensions | 55 × 55 × 65 mm |
| Weight | 300 g |
| IP Rating | IP65 (short-term submersion to 0.3 m) |
| Sensitivity | Detects ≥0.15 mL water droplets falling from ≤200 mm height |
| Max Drip Rate | 5 drops/s |
| Recording Interval | Configurable from 1 s to 24 h |
| Events per Bucket | Up to 16,383 |
| Total Buckets | 32,767 |
| Battery Life | Up to 10 years in sleep mode |
| Data Output | USB 3-pin interface |
| LED Indicators | Three status LEDs (power, activity, error) |
| Environmental Shielding | Acoustic noise rejection for false-trigger suppression (e.g., ambient sound, sheet flow) |
| Brand | SPL |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Transient (Pulsed) Laser Wavefront Distortion Interferometer |
| Pricing | Upon Request |
| Wavelength Range | UV to Mid-Far IR (customizable per application) |
| Aperture Diameter | 10 mm (standard), scalable per user specification |
| Wavefront RMS Accuracy | < λ/15 |
| Maximum Wavefront Deviation Measurement Range | 50 mm |
| Pulse Width Compatibility | Down to 1 ns |
| Laser Damage Threshold | High |
| Camera Resolution | ≥1024 × 1024 (scientific-grade CCD) |
| Interferometric Architecture | Common-path shearing interferometry |
| Software Output | 3D wavefront phase map, contour plot, PV & RMS values, wavefront gradient, Strehl ratio, OTF, PSF |
| Operating System | Windows 2000 or later |
| Compliance | Compatible with ISO 10110-5, ISO 21254 (Laser Damage Threshold Testing), ASTM E284 (Standard Terminology for Optics), supports GLP/GMP audit trails via optional logging modules |
| Brand | TAMASAKI (Kyoto) |
|---|---|
| Origin | Japan |
| Model | AMS-115 |
| Measurement Principle | Digital Current/Voltage/Time Synchronization |
| Measurement Range | 50 A – 999 kA (selectable) |
| Time Resolution | 1 ms |
| Max Monitoring Duration | 9,000 cycles (180 s for AMS-116) |
| Sampling Frequency | Up to 600 Hz |
| Input Channels | Primary current, secondary voltage, electrode displacement (optional), trigger signal |
| Output Interfaces | RS-232C (standard), digital I/O (optional) |
| Configuration Memory | 32 programmable welding condition sets |
| Compliance | Designed for ISO 14001 & JIS B 8711-compliant resistance welding process validation |
| Brand | TAMASAKI (Kyoto) |
|---|---|
| Origin | Japan |
| Model | SP-270-F200N |
| Measurement Principle | Strain-gauge-based force transduction |
| Measurement Range | 20–200 N (F200N variant) |
| Accuracy | ±1% F.S. |
| Overload Capacity | 120% of rated load |
| Output | DC ±2 V F.S. |
| Display | 4-inch TFT color LCD (Japanese/English selectable) |
| Data Sampling | Up to 1 kHz (1 ms interval) via USB |
| Power Supply | Rechargeable battery or USB bus power |
| Auto-power-off | Configurable timeout |
| Operating Temperature | 5–40 °C |
| Sensor Interchangeable | Yes (F200N, F1000N, F10kN, F30kN, F50kN variants) |
| Dimensions (H×W×D) | 140 × 85 × 35 mm |
| Weight (unit + sensor) | 600 g |
| Compliance | Designed for industrial welding process validation per JIS Z 3140 and ISO 14324 Annex B |
| Brand | SPOTRON (TAMASAKI) |
|---|---|
| Origin | Japan |
| Model | SP-3510 |
| Measurement Principle | Rogowski coil-based current sensing + precision shunt/voltage divider |
| Current Range | 1.0–500 kA (RMS or peak) |
| Voltage Range | 0–60.0 V (RMS or peak) |
| Time Measurement | 0.5–9999 cycles (50/60 Hz) or 0.1–9999 ms |
| Accuracy | ±2% FS (current), ±1% FS (voltage), ±0.5 cycle / ±0.1 ms (time) |
| Display | 3.5″ TFT LCD touchscreen (240×320 pixels) |
| Data Storage | SD card (included), USB 2.0 host/device interface |
| Power | Rechargeable lead-acid battery + universal AC adapter (100–240 V, 50/60 Hz) |
| Dimensions | 145 × 183 × 65 mm |
| Weight | ~1.9 kg |
| Compliance | Designed for industrial welding process validation per ISO 14324, AWS D8.8, and JIS Z 3136 |
| Brand | StandardZhuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-300 |
| Price | Upon Request |
| Measurement Range | 0–300 mm |
| Worktable Flatness | 3.5 µm over 760 × 200 mm |
| Standard Mandrel Linearity (Straightness) | ≤1.2 µm |
| Standard Mandrel Parallelism to Reference Axis | ≤1.4 µm |
| Parallel Rule Parallelism | ≤1.4 µm |
| Parallel Rule Flatness | ≤1 µm |
| Parallel Rule Mounting Perpendicularity | ≤2 arcseconds |
| Standard Mandrel Mounting Perpendicularity | ≤2 arcseconds |
| Dimensions (L×W×H) | 760 × 328 × 600 mm |
| Weight | ~190 kg |
| Brand | STARiTECH |
|---|---|
| Origin | Beijing, China |
| Model | TX-183 |
| Interface | USB/RS-232 (balance-compatible) |
| Label Width | Adjustable from 20 mm to 58 mm |
| Printing Method | Direct thermal |
| Supported Codes | Code 128, EAN-13, QR Code, Data Matrix |
| Character Set | Unicode UTF-8 (including GB2312-compliant Chinese characters and Pinyin input) |
| Connectivity | Plug-and-play with analytical balances and lab instruments |
| Compliance | Meets ISO/IEC 15415 & ISO/IEC 15416 print quality standards for 2D/1D symbologies |
| Brand | STARiTECH |
|---|---|
| Origin | Beijing, China |
| Model | TX-900 |
| Print Resolution | 448 dots/line |
| Paper Width | 76 mm |
| Printing Technology | 9-pin dot matrix |
| Ribbon Type | Long-life fabric ribbon |
| Buffer Memory | 8 MB |
| Print Mode | High-speed bidirectional printing |
| Media | Plain paper only |
| Compliance | Suitable for GLP/GMP environments requiring permanent record retention |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | MBQ Series |
| Pricing | Available Upon Request |
| Full-Scale Range | 10 SCCM to 3,000 SLPM |
| Accuracy | ±0.6% of reading or ±0.1% of full scale (whichever is greater) |
| Repeatability | ±0.1% of full scale |
| Response Time | <10 ms |
| Operating Temperature | –10°C to +60°C |
| Maximum Working Pressure | 320 PSIA (22 barA) |
| Battery Life | 18 hours |
| Gas Selection | 98+ NIST-traceable preloaded gases |
| Custom Gas Mixtures | Up to 5 components |
| Display & Control | Backlit LCD with integrated touchpad |
| Output Options | Integrated dual flow accumulators and alarm outputs (optional) |
| Certifications | NIST-traceable calibration certificate included |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GXY-02 |
| Force Sensor Range | 200 N |
| Displacement Resolution | 0.001 mm |
| Deflection Measurement Range | 0–5 mm |
| Accuracy | ±0.01 mm (deflection), ±0.1 N (load), ±0.5 mm (span adjustment) |
| Specimen Span Adjustment | 0–55 mm |
| Needle Outer Diameter Compatibility | 0.3–3.4 mm (normal, thin, and ultra-thin wall) |
| Loading Speed | 1 mm/min ±0.1 mm/min |
| Dimensions | 460 × 340 × 400 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 45–80% RH (non-condensing) |
| Power Supply | 220 V ±22 V, 50 Hz ±11 Hz |
| Brand | SumSpring |
|---|---|
| Model | GXY-02 |
| Measurement Principle | Controlled bending force application with high-resolution deflection sensing |
| Deflection Range | 0–5 mm (±0.01 mm accuracy) |
| Load Range | 1–60 N (±0.1 N accuracy) |
| Needle Diameter Compatibility | 0.3–3.4 mm (standard, thin-wall, and ultra-thin-wall tubing) |
| Support Span Adjustment | 0–55 mm (±0.5 mm accuracy) |
| Loading Speed | 1 mm/min (±0.1 mm/min) |
| Dimensions | 460 × 340 × 400 mm |
| Weight | 25 kg |
| Power Supply | 220 V ± 10 %, 50 Hz ± 2 % |
| Operating Environment | 5–40 °C, RH 45–80 % (non-condensing) |
| Compliance Standards | GB 15811, GB 18457, YBB00092004–2015 |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GXY-02 |
| Force Sensor Range | 5.5–60 N (±0.1 N) |
| Deflection Measurement Range | 0–5 mm (±0.01 mm) |
| Support Span Adjustment | 0–55 mm (±0.5 mm) |
| Needle ID Compatibility | 0.3–3.4 mm (normal/thin/ultra-thin wall) |
| Loading Speed | 1 mm/min (±0.1 mm/min) |
| Displacement Resolution | 0.001 mm |
| Dimensions | 460 × 340 × 400 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 45–80% RH (non-condensing) |
| Power Supply | 220 V ± 10%, 50 Hz ± 2% |
| Brand | ACCRETECH (Tokyo Seimitsu) |
|---|---|
| Origin | Japan |
| Type | CNC-Controlled Non-Contact + Contact Hybrid Profilometer |
| Axes | 5-Axis Synchronized Motion |
| Drive Speed | Up to 100 mm/s |
| Z-Range | 10 mm |
| X-Range | 200 mm |
| Vertical Resolution | 0.31 nm |
| Measurement Principle | High-Stability Homodyne Laser Interferometry (for CREST DX) + Dual-Sensor Tactile Stylus (for NEX 100 DX/SD) |
| Compliance | ISO 25178-605, ISO 4287, ISO 4288, ISO 11562, ISO 21920-1 |
| Operation Mode | Fully Automated |
| Sensor Options | Integrated Dual-Mode (Stylus + Auto-Focus Optical) |
| Software Platform | SURFPAK DX v8.x with Audit Trail & CFR 21 Part 11 Ready Configuration |
| Data Export | CSV, XML, STEP AP212, PDF Report (GLP/GMP Compliant Templates) |
| Brand | ABERLINK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Extol 370/520 |
| Pricing | Available Upon Request |
| Configuration | Hybrid (Contact + Optional Non-Contact Probes) |
| Operation Mode | Fully Automated |
| Machine Architecture | Vertical Cantilever |
| Measurement Principle | Contact-Based Tactile Metrology (ISO 10360-2 Compliant) |
| Brand | T&D |
|---|---|
| Origin | Japan |
| Manufacturer | T&D Corporation |
| Model | 1-5020-31 |
| Channel Count | 1 |
| Temperature Range | -40 to +80 °C |
| Enclosure Rating | IP67 |
| Sensor Coating | FEP (Fluorinated Ethylene Propylene) Resin |
| Cable Length | 0.6 m |
| Interface | USB (PC), Optical Communication (with TR-50U2 base unit) |
| Power Supply | Bus-powered via USB |
| Included Accessories | USB Communication Cable, T&D Logbook Software |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Model | SP-255-FU20kN |
| Measurement Principle | Hydraulic transduction with strain-gauge-based pressure sensing |
| Measurement Range | 2.0 kN to 20.0 kN |
| Resolution | 0.1 kN (10 kgf) |
| Accuracy | ±1% of full scale (FS) |
| Operating Temperature | 0 °C to 40 °C |
| Power Supply | 2 × AA alkaline batteries |
| Battery Life | ≥8 hours (continuous operation) |
| Auto-zero Function | Yes |
| Peak Hold & Data Hold | Yes |
| Auto-power-off | After 5 minutes of inactivity |
| Display Update Rate | 2 Hz (refresh every 0.5 s, with 64 samples/sec internal acquisition) |
| Sensor Housing | Integrated hydraulic insulation structure |
| Weight | 610 g (sensor head + 1.5 m cable), 430 g (main unit with batteries) |
| Brand | Taylor Hobson |
|---|---|
| Origin | United Kingdom |
| Model | PGI Freeform |
| Measurement Principle | Contact Stylus Profilometry with Radial & Grating-Scan Modes |
| Vertical Range | 28 mm |
| Vertical Resolution | 0.8 nm |
| Tilt Capability | ±50° |
| Form Error Accuracy | <150 nm PV |
| Motion Architecture | FEA-Optimized Ultra-Stiff Mechanical Axes |
| Compliance | ISO 10360, ISO 1101, ISO 16610, ISO 25178 (Part 2, Part 601–607), ASTM E1155, USP <1059>, GLP/GMP-ready audit trail support in software |
| Brand | Zhengye |
|---|---|
| Model | ZK2130 |
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range | 20–150 Ω |
| Length Range | 0.05–2 m |
| Accuracy | ±1% @ 50 Ω |
| Measurement Speed | ≤1 s per point |
| Bandwidth | 3 GHz |
| Dynamic Range for S-Parameter Measurement | >100 dB |
| Compliance | Designed for IPC-TM-650 2.5.1 and IPC-TR-579 compliant PCB impedance verification |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Techcomp (formerly Shanghai Jingke/SHANGPING) |
| Product Line | FA-C Series |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg (0.0001 g) |
| Repeatability | 0.1 mg |
| Calibration | Internal calibration (optional SCS Smart Calibration System) |
| Display | Backlit dot-matrix LCD with bilingual (Chinese/English) menu |
| Units | g, ct, oz, dwt, lb, etc. |
| Compliance Features | Real-time clock, GLP/GMP-compliant data logging, EMC-compliant electronics |
| Special Functions | Density determination, percentage weighing, accumulation, counting, below-balance weighing, tare memory |
| Connectivity | RS-232 interface (data cable optional) |
| Qualification Support | 3Q (IQ/OQ/PQ) documentation available |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Techcomp (formerly Jingke/Shangping) |
| Type | Precision Balance |
| Maximum Capacity | 1000 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Linearity Compensation | Multi-point Linear Calibration |
| Drift Compensation | Yes |
| Construction | SMT-assembled PCB with SMD components |
| Display | LCD, low-power |
| Interface | RS232C (optional) |
| Operating Mode | Portable |
| Functions | Accumulation, Piece Counting, Tare, Unit Conversion, Error Alert |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A.B.C.D.E Temperature Indicating Strip |
| Pricing | Available Upon Request |
| Temperature Range | −30 °C to 260 °C |
| Accuracy | ±1 °C |
| Calibration Traceability | ISO/IEC 17025-accredited reference standards |
| Compliance | ISO 9001 certified manufacturing & quality control |
| Format | Adhesive-backed multi-point irreversible thermal indicator strip with 5 discrete temperature bands (A–E), each containing 8 calibrated temperature-sensitive elements |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0516 1901 |
| Dimensions (L×W×H) | 340 × 265 × 60 mm |
| Weight | 1130 g |
| Housing Material | High-strength plastic |
| Interface | USB |
| Capacity | Simultaneous programming and readout of up to 8 compatible Testo data loggers |
| Software | Not included — sold separately |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9330 |
| Communication Interface | Ethernet with IEEE 802.3af PoE (Class 0) |
| Compatibility | testo 150 modular data logger system |
| Channel Architecture | Multi-channel, module-integrated |
| Integration Standard | Designed for testo Saveris Pharma environmental monitoring platform |
| Radio Option Support | Compatible with testo UltraRange wireless extension (optional) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9055 |
| Temperature Measurement Principle | K-type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | −50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Stability | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Response Time (t₉₉) | 10 s in water |
| Weight | 80 g |
| Dimensions (L×W×H) | 270 × 40 × 70 mm |
| Probe Sheath Length | 200 mm |
| Probe Tip Length | 4 mm |
| Probe Rod Diameter | 3 mm |
| Display | Single-line LCD |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | −20 to +70 °C |
| Housing Material | ABS |
| Power Supply | 3 × AAA batteries (rechargeable) |
| Battery Life | Up to 1000 h |
| CE Marking | 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| IP Rating | IP65 |
| Probe Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Folded Dimensions | 163 × 47 × 20 mm |
| Extended Dimensions | 265 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Power Supply | 2 × AAA batteries |
| Battery Life | 100 h (+25 °C, no backlight) |
| Display | Single-line LCD with backlight |
| Compliance | EN 13485, HACCP, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1063 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-30 to +99.9 °C), ±1.0 °C (full range) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| Power Source | CR2032 lithium coin cell |
| Dimensions (L×W×H) | 215 × 34 × 19 mm |
| Weight | 80 g |
| IP Rating | IP67 (with protective sleeve 0516 8265) |
| Measurement Rate | 2 readings per second |
| Compliance | ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | −10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery (approx. 70 h lifetime) |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Sensor Type | Integrated capacitive humidity sensor + NTC temperature sensor |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| IP Rating | IP65 |
| Dimensions (probe extended) | 265 × 47 × 20 mm |
| Dimensions (probe folded) | 163 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Probe Shaft Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| Display | Single-line LCD with backlight |
| Power | 2 × AAA batteries (100 h life at +25 °C, no backlight) |
| Compliance | EN 13485, HACCP principles, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1052 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-20 to +100 °C), ±1.0 °C (-50 to -20.1 °C), ±1% of reading (+100.1 to +275 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| IP Rating | IP65 |
| Display | Backlit LCD (single-line) |
| Power Supply | LR44 button cell battery (80 h typical life) |
| Dimensions (with standard probe) | 148 × 38 × 195 mm |
| Weight (instrument only, standard probe) | 156 g |
| Response Time t₉₉ | 10 s (standard/long probe in liquid), 15 s (frozen goods probe in frozen meat ≈ 60 s) |
| Compliance | EN 13485, HACCP principles, FDA food safety guidelines |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model No. | 0563 1063 |
| Price Range | USD 0.15–750 (FOB) |
| Instrument Category | Insertion-Type Food Thermometer |
| Temperature Range | −50 °C to +275 °C |
| Accuracy | ±0.5 °C (within −20 °C to +50 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | −20 °C to +50 °C |
| Display | Integrated LCD (backlit) |
| Power Supply | 1 × CR2032 button cell (included) |
| Dimensions (L×W×H) | 215 mm × 34 mm × 19 mm |
| Weight | 80 g |