- All
- Favorite
- Popular
- Most rated
| Brand | Metrohm DropSens |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | μStat-i MultiX |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 16 Independent Channels |
| Current Range | ±1 nA to ±10 mA (8 decades) |
| Current Accuracy | ≤0.5% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±4 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 1 mHz to 1 MHz |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Imported |
| Model | 946 |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 814 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Capacity | 12–48 positions (75 mL vials) |
| Sample Volume Range | 75–250 mL |
| Sample Tray Recognition | Optical identification sensor for interchangeable trays |
| Fluid Handling | Single-tower architecture with optional 1 or 2 peristaltic pumps |
| Positioning System | Single movable arm (left- or right-configurable) + single external titration position |
| Functional Capabilities | Liquid handling, precise aspiration/dispensing, automated Karl Fischer coulometric/microcoulometric water determination |
| Method Storage | Up to 999 user-programmable methods |
| Method Structure | Three-phase workflow (Start → Sample Analysis → End), each phase supporting up to 99 sequential steps |
| Interfaces | 1 × USB port, 3 × MSB (Metrohm Serial Bus) ports |
| Host Integration | Designed exclusively for seamless control by Metrohm Titrando series titrators |
| Brand | Metrohm DropSens |
|---|---|
| Origin | Netherlands |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | μ-Stat-i 400(s) |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 nA to ±10 mA |
| Current Accuracy | ≤ 0.5 % of full scale (at 100 nA–10 mA) |
| Potential Accuracy | ±0.2 % |
| Potentiostatic Range | ±4 V |
| EIS Frequency Range | 1 mHz to 1 MHz |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 902 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | Specialized (pH-Stat & Controlled-Dosage Synthesis) |
| Measurement Range | ±1200 mV, ±120 µA |
| Electrode Readout Accuracy | 0.15% (±30 µL @ 20 mL) |
| Electrode Readout Resolution | 0.001 pH, 0.1 mV, 0.1 °C |
| Titration Accuracy | 0.15% (±30 µL @ 20 mL) |
| Titration Resolution | Not applicable |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Benchtop pH Meter |
| Model | 949 |
| Measurement Modes | pH, mV, ORP, Temperature |
| pH Range | −2.00 to 16.00 (resolution: 0.01 pH) |
| mV/ORP Range | −1000.0 to +1999.9 mV (resolution: 0.1 mV) |
| Temperature Range | −10.0 to +110.0 °C (resolution: 0.1 °C) |
| Calibration | Automatic buffer recognition (built-in IUPAC/NIST/USP/DIN buffer tables), up to 5-point calibration |
| Temperature Compensation | Automatic (ATC) and manual |
| Data Storage | Up to 1,000 measurement records with timestamp (date/time stamping) |
| Interface | RS232 serial port for printer or PC connection |
| Compliance | GLP-compliant reporting, audit-ready data logging, electrode calibration reminder |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPELECNIR |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | ±1 nA to ±10 mA |
| Current Accuracy | ±0.5 % of reading |
| Potential Accuracy | ±0.2 % of full scale |
| Potentiostatic Range | ±4 V |
| Impedance Frequency Range | Not applicable (dedicated EC–NIR coupling system, not EIS-capable) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Imported Instrument |
| Model | 916 Ti-Touch |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −2000 mV to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Mode Support | DET, MET, SET (single or dual endpoint), MAT |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 827 |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 865 |
| Instrument Type | Electrochemical Sample Processor |
| Dosing Modes | DOS, XDOS, CNTD, LQT |
| Interface | USB (native), RS-232/USB Box (optional) |
| Display | Large graphical LCD |
| Connectivity | Supports USB Hub for concurrent peripherals (keyboard, mouse, printer, USB storage) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 904 / 906 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose Titration |
| Touchscreen | 90 mm × 120 mm Color LCD |
| Measurement Resolution | 0.001 pH, 0.1 mV, 0.1 °C |
| Sampling Interval | 100 ms |
| Titration Modes | DET (Dynamic Equivalence Point Detection), MET (Fixed-Volume Equivalence Point), SET (Target-Value Titration) |
| Supported Methods | Karl Fischer Coulometric & Volumetric Water Determination, STAT Potentiostatic Titration, pH-metric, Redox, Precipitation, Complexometric Titrations |
| Smart Components | Intelligent Electrodes (auto-recognition), Smart Dosing Unit (Dosino™), Smart Cable (digital signal transmission), 806 Exchange Unit (20,000-step burette resolution) |
| Connectivity | 4 × MSB ports, USB for sample processor/peripherals, PCMCIA slot (methods/data backup/user authentication), Bluetooth® for balance/printer integration |
| Compliance | FDA 21 CFR Part 11, GLP/GMP, ISO/IEC 17025, ASTM E203, USP <921>, EP 2.5.12 |
| Software | tiamo™ v3.x (database server, parallel titration, audit trail, electronic signature), PC Control, LabLink (LAN/internet remote access) |
| Peripheral Support | Up to 9 × 805 Dosing Units, 1 × 806 Exchange Unit, 4 × 801 Magnetic Stirrers or 4 × 804/803 Titration Stands with 802 Rod Stirrers |
| Optional Modules | 867 pH Module, 856 Conductivity Module, Differential Amplifier, Pt1000/NTC Temperature Probes |
| Safety & Security | Password-protected access, role-based user permissions, method locking, detection limit verification, electrode health monitoring (GLP-certified electrode test) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PGSTAT128N |
| Channel Configuration | Single-Channel Workstation |
| Current Range | 10 nA – 100 mA (7 decades) |
| Current Accuracy | ±0.2% of reading and range |
| Potential Range | ±10 V |
| Potential Accuracy | ±2 mV or ±0.2% of set value |
| Potentiostat Bandwidth | >500 kHz |
| Rise/Fall Time (1 V step, 10–90%) | <500 ns |
| Input Bias Current (25 °C) | <1 pA |
| Input Impedance | >100 GΩ |
| Coulometric Bandwidth | >4 MHz |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Sampling Rate | Up to 50 kHz (standard), up to 750 kHz with ADC750 module |
| Potential Resolution | 150 µV (applied), 30/300 µV (measured) |
| Current Resolution | 0.0003% of range (e.g., 30 fA at 10 nA range) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Instrument |
| Model | 912 |
| Portability | Portable |
| Measurement Channels | Dual (Conductivity + pH) |
| IP Rating | IP67 |
| Compliance | GLP-Compliant Data Handling |
| Connectivity | tiBase Software, LIMS, Excel Export |
| Display | Color LCD with Multilingual UI |
| Operating Modes | Field, Laboratory, and Process Support |
| Configuration Options | Portable Base Unit, Lab Station Kit, Field Kit with Accessories |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 914 |
| Detection Parameters | Multi-parameter |
| Portability | Portable |
| Application Environment | Laboratory & Field |
| Conductivity Range | 0.1 µS/cm to 500 mS/cm |
| Temperature Range | −150 °C to +250 °C |
| Voltage Accuracy | ±0.2 mV |
| Voltage Resolution | 0.1 mV |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Electrochemical Workstation |
| Model | VIONIC |
| Current Range | ±6 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±6 A |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Compliance Voltage | ±50 V |
| Minimum Sampling Interval | 1 µs |
| Floating Mode | Optional |
| Dual Reference Electrode Support (S2) | Yes |
| Electrochemical Cell Isolation | Yes |
| Oscillation Protection | Yes |
| Independent Cell Switch | Yes |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Single-Channel Potentiostat/Galvanostat |
| Max Current Output | ±100 mA |
| Current Range | 10 nA – 10 mA (7 decades) |
| Current Resolution | 30 fA (at 10 nA range) |
| Current Accuracy | ±0.2% of reading ± 0.2% of range |
| Potential Range | ±10 V |
| Applied Potential Accuracy | ±2 mV ± 0.2% of setting |
| Potential Resolution | 150 µV (applied), 3–300 µV (measured, selectable) |
| Potentiostat Bandwidth | 1 MHz |
| Rise/Fall Time (1 V step, 10–90%) | < 250 ns |
| Input Impedance | > 100 GΩ |
| Bias Current (25°C) | < 1 pA |
| Coulometric Integrator | Built-in, hardware-based |
| iR Compensation | Positive feedback and current-interrupt modes |
| Electrode Configuration | 2-, 3-, or 4-electrode |
| Analog I/O | 16-bit DAC/ADC, programmable voltage/current control and monitoring |
| Software | NOVA 2.1+ (Windows only) |
| Compliance | CE, RoHS, ISO 9001 certified design |
| Data Integrity | Audit-trail enabled in NOVA for GLP/GMP environments |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Category | Imported Instrument |
| Model | OMNIS KF Oven |
| Instrument Type | Automated Sample Processor for Electrochemical Moisture Analysis |
| Maximum Heating Temperature | 300 °C |
| Sample Capacity | Up to 100 × 6 mL vials (unattended) |
| Compatible Vial Standards | ISO 8362 (2R–30R), plus standard 6 mL crimp-top and 8 mL screw-cap vials |
| Heating Modules | Configurable with 1 or 2 independent oven modules |
| Carrier Gas Options | Dry ambient air or nitrogen, with integrated large-capacity molecular sieve dryer |
| Needle Depth Adjustment | Motorized, programmable syringe needle extension for optimal vial penetration |
| Optional Integration | OMNIS Liquid Handling Module for automatic reagent replenishment (KF reagent and methanol) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 826 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter |
| Connectivity | IrDA (Infrared Data Association) |
| GLP Compliance | Yes |
| Data Storage Capacity | 200 measurements (with timestamp, date, and ID) |
| Power Supply | 4 × 1.5 V LR6 (AA) alkaline batteries |
| Battery Life | ≥500 hours |
| Ingress Protection Rating | IP67 |
| Electrode Compatibility | Primatrode series (e.g., 6.0228.020) |
| Calibration | Auto-buffer recognition, automatic temperature compensation (ATC), up to 3-point calibration |
| Software Integration | Metrodata VESUV 3.0, LIMS-compatible export |
| Operating Interface | Cursor-controlled text-guided menu |
| Enclosure Material | High-grade polymer with ergonomic, lab-grade finish |
| Optional Accessory | Integrated carry case with fold-out workstation surface |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Eco |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −2000 mV to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Delivery Resolution | μL-level (compliant with DIN EN ISO 8655-6) |
| GLP/GMP Compliance | Full audit trail, method protection, electronic signature support |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 910 |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±2 nA to ±200 µA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±2.048 V |
| Impedance Frequency Range | Not supported (DC-only operation) |
| Potential Resolution | 1 mV |
| Current Resolution | 1 pA (at 2 nA range) |
| Dimensions | 80 × 54 × 23 mm |
| Weight | 94 g |
| Power Supply | 5 V DC / ≤45 mA via USB |
| Interface | Mini-USB + 8-pin Mini-DIN (5 digital I/O, 3 analog inputs @ 10-bit ADC, 1 analog output 0–5 V) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Automatic Potentiometric Titrator |
| Model | 855 |
| Instrument Category | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | ±1200 mV, ±120 µA |
| Meter Accuracy | 0.15% (±30 µL at 20 mL) |
| Meter Resolution | 0.001 pH, 0.1 mV, 0.1 °C |
| Titration Accuracy | 0.15% (±30 µL at 20 mL) |
| Titration Resolution | Not specified |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | 814, 815 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Capacity (814) | 12–48 positions (75 mL vials) |
| Sample Capacity (815) | 28–141 positions (75 mL vials) |
| Sample Volume Range (814) | 75–250 mL |
| Sample Volume Range (815) | 11–250 mL |
| Sample Tray Recognition | Optical cup identification sensor |
| Pump Configuration (814) | 1–2 peristaltic pumps |
| Pump Configuration (815) | 2–4 peristaltic pumps |
| Robotic Arm Configuration (814) | Single arm (left- or right-mounted) |
| Robotic Arm Configuration (815) | Dual arms (independently configurable left/right) |
| Dispensing Positions (814) | One external titration position |
| Dispensing Positions (815) | Two external titration positions |
| Method Storage | Up to 999 user-programmable methods |
| Method Structure | Three-phase architecture (Start → Sample Analysis → End), each phase supporting up to 99 programmable steps |
| Interface | USB 2.0 + 3× MSB (Metrohm Serial Bus) ports |
| Host Integration | Fully controlled by Titrando series titrators |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Modular Bipotentiostat/Galvanostat |
| Channels | Dual-channel (expandable to multi-channel via MUX module) |
| Current Range | 10 nA – 1 A (9 auto-ranging decades) |
| Current Accuracy | ±0.2% of reading and ±0.2% of range |
| Potential Accuracy | ±2 mV + 0.2% of set value |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A |
| Maximum Output Voltage | ±30 V |
| CV Scan Rate | up to 250 V/s |
| Input Impedance | >1 TΩ |
| Response Time | <250 ns |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Sampling Rate | up to 50 kHz (standard), 10 MHz with ADC10M module |
| EIS Modes | 6 distinct impedance acquisition protocols including potential-frequency, time-frequency, current-frequency sweeps |
| Software Platform | NOVA 2.x (Windows-based, FDA 21 CFR Part 11 compliant with audit trail and electronic signature support) |
Show next