- All
- Favorite
- Popular
- Most rated
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 814 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Capacity | 12–48 positions (75 mL vials) |
| Sample Volume Range | 75–250 mL |
| Sample Tray Recognition | Optical identification sensor for interchangeable trays |
| Fluid Handling | Single-tower architecture with optional 1 or 2 peristaltic pumps |
| Positioning System | Single movable arm (left- or right-configurable) + single external titration position |
| Functional Capabilities | Liquid handling, precise aspiration/dispensing, automated Karl Fischer coulometric/microcoulometric water determination |
| Method Storage | Up to 999 user-programmable methods |
| Method Structure | Three-phase workflow (Start → Sample Analysis → End), each phase supporting up to 99 sequential steps |
| Interfaces | 1 × USB port, 3 × MSB (Metrohm Serial Bus) ports |
| Host Integration | Designed exclusively for seamless control by Metrohm Titrando series titrators |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 865 |
| Instrument Type | Electrochemical Sample Processor |
| Dosing Modes | DOS, XDOS, CNTD, LQT |
| Interface | USB (native), RS-232/USB Box (optional) |
| Display | Large graphical LCD |
| Connectivity | Supports USB Hub for concurrent peripherals (keyboard, mouse, printer, USB storage) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Category | Imported Instrument |
| Model | OMNIS KF Oven |
| Instrument Type | Automated Sample Processor for Electrochemical Moisture Analysis |
| Maximum Heating Temperature | 300 °C |
| Sample Capacity | Up to 100 × 6 mL vials (unattended) |
| Compatible Vial Standards | ISO 8362 (2R–30R), plus standard 6 mL crimp-top and 8 mL screw-cap vials |
| Heating Modules | Configurable with 1 or 2 independent oven modules |
| Carrier Gas Options | Dry ambient air or nitrogen, with integrated large-capacity molecular sieve dryer |
| Needle Depth Adjustment | Motorized, programmable syringe needle extension for optimal vial penetration |
| Optional Integration | OMNIS Liquid Handling Module for automatic reagent replenishment (KF reagent and methanol) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | 814, 815 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Capacity (814) | 12–48 positions (75 mL vials) |
| Sample Capacity (815) | 28–141 positions (75 mL vials) |
| Sample Volume Range (814) | 75–250 mL |
| Sample Volume Range (815) | 11–250 mL |
| Sample Tray Recognition | Optical cup identification sensor |
| Pump Configuration (814) | 1–2 peristaltic pumps |
| Pump Configuration (815) | 2–4 peristaltic pumps |
| Robotic Arm Configuration (814) | Single arm (left- or right-mounted) |
| Robotic Arm Configuration (815) | Dual arms (independently configurable left/right) |
| Dispensing Positions (814) | One external titration position |
| Dispensing Positions (815) | Two external titration positions |
| Method Storage | Up to 999 user-programmable methods |
| Method Structure | Three-phase architecture (Start → Sample Analysis → End), each phase supporting up to 99 programmable steps |
| Interface | USB 2.0 + 3× MSB (Metrohm Serial Bus) ports |
| Host Integration | Fully controlled by Titrando series titrators |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 869 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Positions | 12 (120 mL vials) |
| Built-in Method Storage | Up to 100 user-editable methods |
| Interface | USB |
| Compatibility | Titrino Plus series titrators (direct connection, no external controller or PC required) |
| Optional Accessory | 843 Pump Unit for automated rinsing and drainage |
| Emergency Sample Slot | Yes |
| Control Interface | Integrated membrane keypad with large LCD display |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 876 |
| Instrument Type | Electrochemical Liquid Handler / Semi-Automatic Titration System |
| Connectivity | USB interface (supports USB Hub for multi-device integration), optional RS-232/USB Box for balance interfacing |
| Dosing Modes | DOS (Manual Dosing with Endpoint Monitoring), XDOS (Extended Dosing with preset volume, time, or flow rate control) |
| Compatibility | Fully interoperable with Metrohm 805 Dosimat for continuous reagent dispensing |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 800 |
| Pricing | Upon Request |
| Instrument Type | Electrochemical Sample Handler / Reagent Dispenser |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 815 |
| Instrument Category | Electrochemical Sample Processor |
| Sample Capacity | 28–141 positions (75 mL vials) |
| Sample Volume Range | 11–250 mL |
| Modular Configuration | Single or dual work towers |
| Fluid Handling | Up to four peristaltic pumps (configurable) |
| Robotic Arms | Dual movable arms (left/right orientation) |
| External Titration Positioning | Dual external titration stations |
| Detection | Optical sample cup identification sensor |
| Method Storage | 999 programmable methods |
| Method Structure | Three-phase architecture (Start / Sample Analysis / End), each phase supporting up to 99 discrete steps |
| Interfaces | 1× USB 2.0, 3× MSB (Metrohm Serial Bus) |