Empowering Scientific Discovery

Metrohm China Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
OriginSwitzerland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelsTitrIC System 1, TitrIC System 2, TitrIC System 3
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
OriginNetherlands
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model2035
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
OriginNetherlands
ManufacturerMetrohm AG (in collaboration with ECN & Applikon)
ModelMARGA 2S
Instrument TypeOnline Continuous Monitor
ComplianceEPA ETV Verified
SoftwareMARGA Control Suite v5.x
Data OutputReal-time ion concentrations (µg/m³), hourly time resolution
Sample StreamsSimultaneous PM₂.₅, PM₁₀, gaseous HNO₃, HCl, NH₃, SO₂, HCOOH, CH₃COOH
Detection PrincipleWet-chemical absorption + Dual IC (Ion Chromatography)
Automation LevelFully unattended operation up to 168 h
Remote CapabilitySecure web-based monitoring, diagnostic access, and parameter control via TLS-encrypted interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
OriginSwitzerland
Manufacturer TypeManufacturer
Origin CategoryImported
ModelMARS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
OriginSwitzerland
ManufacturerMetrohm AG
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detectable MetalsAs, Hg, Cu, Pb, Cd, Zn, Fe, Ni, Co, Mn, Bi, Sb, Tl, Cr, Se, Te
Analysis Time<5 minutes per sample
Current Range Accuracy±0.025%
Potential Resolution±0.2 mV
Electrode OptionsscTRACE Gold electrode or disposable screen-printed electrodes (SPE)
Power SupplyRechargeable Li-ion battery
ComplianceDesigned to meet WHO drinking water guideline requirements for heavy metals
SoftwareIntegrated VA software with pre-validated ASTM/ISO-aligned methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetrohm
ModelPILS
OriginImported (Switzerland/USA)
ManufacturerMetrohm AG (via Applikon BV)
Power Supply110–240 V, 50/60 Hz
Sampling Time15 min – 1 h
Aerosol Size Range0.01–10 µm
Liquid Collection MediumDeionized Water
CompatibilityIon Chromatography (IC), including Metrohm and third-party systems
Internal Standard IntegrationYes
Self-Cleaning FunctionYes
Flow Rate Limiting1 m³/h
ComplianceDesigned for GLP/GMP-aligned environmental monitoring workflows
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0