- All
- Favorite
- Popular
- Most rated
| Brand | Metrohm DropSens |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | μStat-i MultiX |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 16 Independent Channels |
| Current Range | ±1 nA to ±10 mA (8 decades) |
| Current Accuracy | ≤0.5% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±4 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 1 mHz to 1 MHz |
| Brand | Metrohm DropSens |
|---|---|
| Origin | Netherlands |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | μ-Stat-i 400(s) |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 nA to ±10 mA |
| Current Accuracy | ≤ 0.5 % of full scale (at 100 nA–10 mA) |
| Potential Accuracy | ±0.2 % |
| Potentiostatic Range | ±4 V |
| EIS Frequency Range | 1 mHz to 1 MHz |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPELECNIR |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | ±1 nA to ±10 mA |
| Current Accuracy | ±0.5 % of reading |
| Potential Accuracy | ±0.2 % of full scale |
| Potentiostatic Range | ±4 V |
| Impedance Frequency Range | Not applicable (dedicated EC–NIR coupling system, not EIS-capable) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PGSTAT128N |
| Channel Configuration | Single-Channel Workstation |
| Current Range | 10 nA – 100 mA (7 decades) |
| Current Accuracy | ±0.2% of reading and range |
| Potential Range | ±10 V |
| Potential Accuracy | ±2 mV or ±0.2% of set value |
| Potentiostat Bandwidth | >500 kHz |
| Rise/Fall Time (1 V step, 10–90%) | <500 ns |
| Input Bias Current (25 °C) | <1 pA |
| Input Impedance | >100 GΩ |
| Coulometric Bandwidth | >4 MHz |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Sampling Rate | Up to 50 kHz (standard), up to 750 kHz with ADC750 module |
| Potential Resolution | 150 µV (applied), 30/300 µV (measured) |
| Current Resolution | 0.0003% of range (e.g., 30 fA at 10 nA range) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Electrochemical Workstation |
| Model | VIONIC |
| Current Range | ±6 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±6 A |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Compliance Voltage | ±50 V |
| Minimum Sampling Interval | 1 µs |
| Floating Mode | Optional |
| Dual Reference Electrode Support (S2) | Yes |
| Electrochemical Cell Isolation | Yes |
| Oscillation Protection | Yes |
| Independent Cell Switch | Yes |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Single-Channel Potentiostat/Galvanostat |
| Max Current Output | ±100 mA |
| Current Range | 10 nA – 10 mA (7 decades) |
| Current Resolution | 30 fA (at 10 nA range) |
| Current Accuracy | ±0.2% of reading ± 0.2% of range |
| Potential Range | ±10 V |
| Applied Potential Accuracy | ±2 mV ± 0.2% of setting |
| Potential Resolution | 150 µV (applied), 3–300 µV (measured, selectable) |
| Potentiostat Bandwidth | 1 MHz |
| Rise/Fall Time (1 V step, 10–90%) | < 250 ns |
| Input Impedance | > 100 GΩ |
| Bias Current (25°C) | < 1 pA |
| Coulometric Integrator | Built-in, hardware-based |
| iR Compensation | Positive feedback and current-interrupt modes |
| Electrode Configuration | 2-, 3-, or 4-electrode |
| Analog I/O | 16-bit DAC/ADC, programmable voltage/current control and monitoring |
| Software | NOVA 2.1+ (Windows only) |
| Compliance | CE, RoHS, ISO 9001 certified design |
| Data Integrity | Audit-trail enabled in NOVA for GLP/GMP environments |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 910 |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±2 nA to ±200 µA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±2.048 V |
| Impedance Frequency Range | Not supported (DC-only operation) |
| Potential Resolution | 1 mV |
| Current Resolution | 1 pA (at 2 nA range) |
| Dimensions | 80 × 54 × 23 mm |
| Weight | 94 g |
| Power Supply | 5 V DC / ≤45 mA via USB |
| Interface | Mini-USB + 8-pin Mini-DIN (5 digital I/O, 3 analog inputs @ 10-bit ADC, 1 analog output 0–5 V) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Modular Bipotentiostat/Galvanostat |
| Channels | Dual-channel (expandable to multi-channel via MUX module) |
| Current Range | 10 nA – 1 A (9 auto-ranging decades) |
| Current Accuracy | ±0.2% of reading and ±0.2% of range |
| Potential Accuracy | ±2 mV + 0.2% of set value |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A |
| Maximum Output Voltage | ±30 V |
| CV Scan Rate | up to 250 V/s |
| Input Impedance | >1 TΩ |
| Response Time | <250 ns |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Sampling Rate | up to 50 kHz (standard), 10 MHz with ADC10M module |
| EIS Modes | 6 distinct impedance acquisition protocols including potential-frequency, time-frequency, current-frequency sweeps |
| Software Platform | NOVA 2.x (Windows-based, FDA 21 CFR Part 11 compliant with audit trail and electronic signature support) |
| Brand | Metrohm Autolab |
|---|---|
| Model | μAUTOLAB III |
| Max Output Current | ±250 mA |
| Max Output Voltage | ±100 V |
| Potential Range | ±10 V |
| Applied Potential Accuracy | ±2 mV ± 0.2% of set value |
| Applied Potential Resolution | 150 µV |
| Measured Potential Resolution | 30 µV (high-res mode) or 300 µV |
| Current Range | 10 nA to 100 mA (8 decades) |
| Current Accuracy | ±0.2% of reading ± 0.2% of range |
| Applied Current Resolution | 0.03% of range |
| Measured Current Resolution | 0.0003% of range (30 fA at 10 nA range) |
| Potentiostat Bandwidth | >400 kHz |
| Rise/Fall Time (1 V step, 10–90%) | <500 ns |
| Electrometer Input Impedance | >100 GΩ |
| Input Bias Current (@25°C) | <1 pA |
| Electrometer Bandwidth | >4 MHz |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Sampling Rate | up to 750 kHz (with ADC750 module) |
| iR Compensation Range | 0–200 MΩ, resolution 0.025% |
| Electrode Configurations | 2-, 3-, or 4-electrode modes |
| Analog I/O | Dual-channel DAC/ADC for external control and synchronization |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multi Autolab/M204 |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 12 independent channels |
| Current Range | 10 mA to 10 nA (7 decades) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PGSTAT 302F |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Multi-Channel Workstation |
| Current Range | 10 nA – 1 A |
| Current Accuracy | ±0.2% of reading or range |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 10 µHz – 1 MHz |
| Floating Mode Capability | Yes (dual-mode operation: grounded and floating) |
| Input Bias Current (25°C) | <1 pA |
| Potential Resolution | 300 nV |
| Current Resolution (at 10 nA range) | 30 fA |
| Compatible FRA Module | FRA32M (±2 A max output, ±30 V max output, 9 current ranges) |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Model | AUT-RDE |
| Rotation Speed Range | 0–10,000 rpm (1 rpm step size, acceleration: 4,000 rpm/s) |
| Speed Control | Manual or external potentiostat-triggered (e.g., Autolab, CHI, Biologic) |
| Speed Feedback | Integrated optical encoder with closed-loop control (±2 rpm accuracy at 10,000 rpm) |
| Contact Method | Dual-seal mercury pool (liquid Hg-based conduction, no carbon brushes required) |
| Sealing | Fully sealed rotating assembly immersed in electrolyte cell |
| Electrode Head Compatibility | Interchangeable RRDE and RDE heads |
| RRDE Head Options | Pt/Pt, Au/Pt, GC/Pt |
| Collection Efficiency | 24.9% (calibrated per ASTM D3765-18 practice) |
| Disk-Ring Gap | 375 µm |
| Max Current Rating | 500 mA |
| Footprint | Compact design optimized for glovebox integration (W × D × H: 185 × 160 × 320 mm) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Research-Grade Potentiostat/Galvanostat |
| Model | PGSTAT204 |
| Channel Configuration | Multi-Channel Workstation |
| Current Range | 10 nA – 100 mA (8 decades) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±10 V |
| Maximum Output Current | ±400 mA |
| Compliance Voltage | ±20 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Potential Resolution | 3 µV |
| Current Resolution (10 nA range) | 30 fA |
| Input Bias Current (@25°C) | <1 pA |
| Potentiostat Bandwidth | 1 MHz |
| Analog Integrator | Built-in, with integration times of 0.01 s, 0.1 s, 1 s, and 10 s |
| Electrode Configurations | 2-, 3-, or 4-electrode |
| Analog I/O | Bidirectional analog input/output for external signal synchronization |
| Expansion Slot | 1 × modular expansion slot (supports FRA32M, BA, pX1000, MUX, EQCM modules) |
| Interface | USB 2.0 |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Status | Imported |
| Model | SPELEC |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±4 V |
| EIS Frequency Range | 10 mHz – 1 MHz |
| Optical Detection Ranges | 200–900 nm or 350–1050 nm (user-selectable) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SPELEC RAMAN |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% of full scale |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±4 V |
| AC Impedance Frequency Range | Not specified |
| Optical Detection Range | 350–1050 nm (UV/VIS spectrometer integrated) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Single-Channel Electrochemical Workstation |
| Current Range | 1 nA to 100 mA |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| EIS Measurement Accuracy | >99.7% |
| Software | NOVA 2.x |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SECM |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | 10 pA – 100 pA |
| Current Resolution | 0.3 fA |
| Potential Accuracy | ±0.3 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Positioning System | XYZ Stepper Motor Control |
| Scan Volume (Standard) | 25 × 25 × 25 mm |
| Max Linear Scan Speed | 10 mm/s |
| Spatial Resolution | 20 nm |
| Operating Modes | Feedback Mode, Generation-Collection (GC) Mode, Direct Mode, AC-SECM (Local Impedance), 4D Mode, Shear-Force Mode |
| Scan Types | 2D, 3D, Equidistant, Fast Equidistant, User-Defined Electrochemical Protocol Scans |
| Brand | Autolab |
|---|---|
| Origin | Imported (Netherlands) |
| Instrument Type | Electrochemical Impedance Spectroscopy (EIS) Control & Analysis Software |
| Frequency Range | 10 Hz – 1 MHz (single-sweep, no segmentation required) |
| Supported Measurement Modes | Potentiostatic EIS, Galvanostatic EIS, Potential Sweep EIS, Current Sweep EIS, Time-Resolved EIS |
| Data Visualization | Nyquist, Bode ( |
| Curve Fitting Engine | EQUIVCRT-based equivalent circuit modeling |
| Validation Tools | Kramers–Kronig transform consistency testing |
| Compliance | Fully compatible with Autolab PGSTAT series potentiostats/galvanostats |
Show next