| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Bigdipper Instruments Co., Ltd. |
| Model | T-BD5 MS1204p |
| Measurement Principle | Microwave attenuation (MS1204 sensor technology) |
| Operating Temperature | 100–350 °C |
| Pressure Rating | 1.6–4.0 MPa |
| Water Content Range | 0.02–101% w/w |
| Resolution | 0.02–0.1% |
| Repeatability | ±0.05% to ±1.0% FS |
| Output | 4–20 mA analog, RS232/RS485, Modbus RTU, IEEE 1451.2 STIM |
| Enclosure Rating | NEMA 7/8/9 |
| Intrinsic Safety | Ex ia IICT6 |
| Flameproof Protection | Ex d ia IIC T5 |
| Wetted Materials | 1Cr18Ni9Ti stainless steel, polyimide |
| Installation Options | Threaded (ZG1", NPT), flanged, clamp-type, bypass |
| Flow Orientation | Counter-flow (frontal insertion) |
| Sensor Geometry | Insertion-type probe with optimized electromagnetic field distribution |
| Compliance | ASTM D4006, ISO 9001, GB/T 11141-2014, ATEX Directive 2014/34/EU (via third-party certification), IEC 60079-0/-11/-14, FDA 21 CFR Part 11 (data integrity support via audit trail in BD5xCMD firmware) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | T-BD5-EMC1204 |
| Operating Temperature | -10°C to 40°C |
| Storage Temperature | -41°C to 71°C |
| Supply Voltage | DC 24 V |
| Output Signal | 4–20 mA |
| Response Time | <10 ms |
| Thread Interface | G1" (external) |
| Accuracy | ±0.5%–1.5% FS |
| IP Rating | IP65 |
| Intrinsically Safe Design | Ex ia IIC T6 |
| Hazardous Area Classification | Class I, Groups A/B/C/D |
| Contact Materials | 304 Stainless Steel + PTFE |
| Communication | RS232 / RS485 / IEEE 1451.2 STIM / Modbus RTU |
| Transmitter Options | BD5xCD (with local display) or BD5xC (no display) |
| Typical Measurands | Water-in-oil, oil-in-water, polymer solutions, emulsions, slurries, pulp suspensions, solvents, pharmaceutical intermediates |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | T-BD5IMD+MS1204pcR0.01-10T120 P1.6 |
| Operating Pressure | 1.6 MPa (standard) |
| Temperature Range | -40°C to +100°C |
| Moisture Range | 0–100.0% w/w |
| Accuracy | ≤0.1% FS |
| Repeatability | ±0.1% FS |
| Resolution | 0.01% |
| Insertion Depth | 240 mm (standard, customizable) |
| Enclosure Rating | IP56 / NEMA 4X |
| Explosion Protection | Ex ia IIC T4 Ga |
| Wetted Materials | 1Cr18Ni9Ti (AISI 321 stainless steel) |
| Power Supply | 9–24 V DC @ 100 mA |
| Output Signal | 4–20 mA (configurable, full-scale) |
| Total Length | <700 mm |
| Weight | 2.5–5 kg |
| Brand | Brabender |
|---|---|
| Origin | Germany |
| Model | MT-C |
| Measurement Principle | Convection Oven Drying (Gravimetric) |
| Compliance | ICC Standard 110/1, ISO 712, EC Regulation No. 2182/2005 (Tobacco), German Legal Metrology Approval for Tobacco Testing |
| Sample Capacity | Up to 10 samples simultaneously |
| Moisture Range | 0.1–99.9% w/w |
| Resolution | 0.1% moisture |
| Maximum Drying Temperature | 200 °C |
| Automation | Fully automated drying, cooling-free re-weighing, and data logging |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Computrac MAX-4000XL |
| Price Range | USD $12,500 – $37,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Computrac MAX-5000XL |
| Price Range | USD $13,500 – $40,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Computrac Vapor Pro XL |
| Application | Multi-purpose moisture analyzer |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 ppm |
| Repeatability | ≤10% C.V. (for samples >0.1% moisture), ≤15% C.V. (for samples <0.1% moisture) |
| Temperature Range | 25–300°C |
| Sample Weight | 0.01–8 g |
| Display Units | %, ppm, µg |
| Storage Capacity | 250 methods, 1000 results, 100 moisture curves |
| End Criteria | Predictive, Rate, Time, Time-Rate |
| Calibration | NIST-traceable capillary |
| Power | 100–120 V~ / 220–240 V~, 50/60 Hz |
| Dimensions | 17.2 × 47 × 27.9 cm |
| Weight | 8.0 kg |
| Certifications | UL, CE |
| Compliance Options | 21 CFR Part 11 (optional), ASTM D7191-10, ASTM D7546-15 |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | SMART Q |
| Heating Method | Infrared |
| Measurement Range | 0.01–15% moisture content |
| Resolution | 0.001% |
| Balance Precision | 0.0001 g (4-digit analytical balance with 3-digit moisture display) |
| Sample Types | Solids, powders, slurries, non-polar solvents, low-moisture polymers, coatings, pharmaceuticals |
| Compliance | Designed for GLP/GMP environments |
| Brand | PROCESS INSTRUMENTS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Chanscope II |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature Range | –20 °C to +40 °C |
| Accuracy | ±0.2 °C |
| Repeatability | ±0.1 °C |
| Brand | Chengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Lab-Scale Dew Point Analyzer |
| Model | USI-3 |
| Pricing | Available Upon Request |
| Instrument Principle | Electrolytic (Phosphorus Pentoxide Sensor) |
| Operating Temperature | 5–35 °C |
| Accuracy | ±3% of total water mass |
| Repeatability | ≤1% RSD |
| Measurement Range | 0.0000–99.999 mg H₂O |
| Power Supply | AC 220 ± 22 V, 50–60 Hz or DC 10–45 V (for integrated dryer unit) |
| Carrier Gas | Ultra-Dry Nitrogen (<10 ppmv H₂O), Flow Rate: 70 ± 20 mL/min |
| Brand | CMC (Schimse) |
|---|---|
| Origin | Germany |
| Model | TMA-202-W-Ex |
| Product Type | In-line Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Temperature Range | 5–65 °C |
| Display | Touchscreen with optional Chinese language interface |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Intrinsic Safety | Integrated Zener barrier (Ex ia IIC T4 Ga) |
| Enclosure | IP65 |
| Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Brand | D&T |
|---|---|
| Origin | Tianjin, China |
| Model | EX-FH104A |
| Heating Source | Halogen Lamp |
| Weighing Range | 120 g |
| Readability | 0.1 mg |
| Repeatability (2 g sample) | 0.05% SD, ±0.1% |
| Repeatability (10 g sample) | 0.01% SD, ±0.05% |
| Moisture Readability | 0.001% MC |
| Calibration | Fully Automatic Internal Calibration |
| Drying Temperature Range | Single-Glass Mode: 40–160 °C |
| Dual-Glass Mode | 40–200 °C |
| Increment | 1 °C |
| Pan Diameter | Φ90 mm |
| Dimensions (W × D × H) | 200 × 385 × 120 mm |
| Moisture Range | 0.01–100% MC |
| Method Storage | 300 methods |
| Result Storage | 3000 records |
| Heating Programs | Standard, Stepwise, Rapid |
| Drying Termination Modes | Timed, Auto (5 preset weight-loss thresholds + user-defined threshold) |
| Warm-up Time | 20–30 min |
| Display Modes | %MC, %DC, g |
| Output Interfaces | RS232/RS485, LAN, USB1 (data export/firmware update), USB2 (dedicated printer) |
| Touchscreen | 7-inch capacitive |
| Sensor Type | Integrated electromagnetic force compensation sensor |
| Design | Separated weighing and display units |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DMS-4KEA |
| Price | USD 2,150 (FOB Shanghai) |
| Heating Method | Halogen Lamp |
| Weighing Range | 0–110 g |
| Weighing Accuracy | ±0.001 g |
| Moisture Determination Range | 0.001–100% |
| Temperature Control Range | 40–200 °C |
| Typical Measurement Time | ≤8 min |
| Display | 7-inch capacitive touchscreen |
| Language Support | English & Chinese |
| Built-in Functions | Auto-tare, one-touch preheat, temperature calibration, label printing, silent cooling fan, dual-drive automatic door opening |
| Optional Connectivity | Bluetooth 5.0 & Wi-Fi 802.11 b/g/n |
| User Management | Administrator & operator accounts with password protection |
| Internal Calibration | Scheduled interval setting with audit trail |
| Compliance | ASTM D4052, ISO 1183, USP <921>, GB/T 29246–2012 |
| Brand | Deleite |
|---|---|
| Origin | Shanghai, China |
| Model | DR-506 |
| Measurement Principle | Microbial Electrode Method |
| Standard Compliance | HJ/T 86–2002 |
| Measuring Range | 2–50 mg/L (up to 4000 mg/L with dilution) |
| Repeatability | ≤10% RSD |
| Accuracy | ±5% of reading |
| Resolution | 0.1 mg/L |
| Sample Throughput Time | 5–8 min per sample |
| Sample Volume Required | 50 mL per assay |
| Flow Rate | Constant-flow continuous injection (5 mL/min buffer consumption) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 100 W |
| Dimensions (W×D×H) | 560 × 360 × 210 mm |
| Net Weight | 16 kg (shipping weight ~20 kg) |
| Sample Handling | No pretreatment required |
| Microbial Sensor | Non-pathogenic, immobilized nitrifying bacteria strain |
| Data Output | Integrated thermal printer |
| Brand | Deleite |
|---|---|
| Origin | Shanghai, China |
| Model | HE100-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability | ±0.30% (with 3 g sample) |
| Temperature Range | 40–180 °C |
| Heating Time | 1–99 min (1 min increments) |
| Sample Pan Diameter | 100 mm |
| Communication Interface | RS232 |
| Displayed Parameters | % Moisture, % Solids, Time, Temperature, Weight, Date |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | C2010 |
| Price | USD 2,650 (approx.) |
| Transmitter | Vaisala HUMICAP® Humidity Sensor |
| Dew Point Range | –100 to +20 °C or –60 to +60 °C |
| Power Supply | 12–28 VDC |
| Output Signal | 4–20 mA (linear, full-scale span) |
| Interchangeability | Fully interchangeable transmitter modules |
| Accuracy | ±2 °C dew point (within calibrated range) |
| Operating Temperature | –40 to +60 °C |
| Temperature Compensation | Integrated digital temperature compensation |
| Maximum Working Pressure | 30 MPa |
| Flow Rate (Standard Sampling System) | 1–5 L/min |
| Flow Rate (Direct-Insertion Mode with 80 µm Sintered Filter) | 0–10 Nl/min |
| Traceability | Calibrated against NPL (UK) and NIST (US) standards for –75 to +20 °C dew point |
| Fault Indication | 23 mA (transmitter fault), 4 mA (below lower limit), 20 mA (above upper limit) |
| Brand | EdgeTech |
|---|---|
| Origin | USA |
| Model | DPS |
| Type | Online Dew Point Meter |
| Principle | Chilled-Mirror Condensation |
| Operating Temperature Range | 20–99 °C |
| Accuracy | ±0.2 °C |
| Repeatability | ±0.05 °C |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-2S |
| Titration Mode | Fully Automated |
| Method Type | Dual-Mode (Coulometric & Volumetric Karl Fischer) |
| Measurement Resolution | 0.01 μA |
| Water Content Range | 0.01 mg to 100% w/w |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | 0.1 μA |
| Drift Compensation | Automatic background drift correction (drift <5 µg H₂O/min) |
| Detection Limit | 0.01 mg H₂O |
| Sample Forms | Liquids, solids, gases, pastes |
| Display & Interface | Bilingual (Chinese/English) LCD with real-time titration curve visualization |
| Data Output | GLP/GMP-compliant report formats (%, ppm, mg), statistical analysis capability |
| Software | Embedded titration monitoring software with firmware upgrade support |
| Compliance | Designed for ISO 8533, ASTM E203, USP <921>, and EP 2.5.12 environments |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-3S |
| Titration Mode | Fully Automatic |
| Method Principle | Volumetric & Coulometric Karl Fischer Titration |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ±10 ppm |
| Minimum Dispensing Volume | 0.1 µL (1/20000 of burette volume) |
| Titration Control Precision | 0.1 µL |
| Polarization Voltage Output | 0–2550 mV (10 mV step, <±3% error) |
| Max Polarization Current | 5 mA |
| Current Range | 0–200 µA |
| Effective Current Accuracy | ±0.1 µA |
| Drift Compensation | Auto/manual background subtraction |
| Data Output Compliance | GLP/GMP-compliant reporting format |
| Interface | RS-232C (printer & PC connection) |
| Method Storage | 100 protocols |
| Optional | Dead-stop titration capability with accessory kit |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZDJ-600S |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ≤0.2% RSD |
| Minimum Dispensing Volume | 5 µL |
| Burette Precision | 1/20,000 |
| Burette Capacity | 10 mL (standard) |
| Burette Accuracy | ±10 µL @ 10 mL |
| Polarization Current Range | 0–200 µA |
| Polarization Voltage Range | 0–2550 mV |
| Polarization Voltage Step | 10 mV |
| Effective Current Accuracy | Better than ±0.1 µA |
| Repeatability (Pure Water) | <1% RSD |
| Standardization Repeatability | ±0.5% of mean across three consecutive runs |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | W202-1 |
| Application | Multi-purpose WVTR analyzer for films, sheets, and packaging containers |
| Test Range | 0.001–100 g/(m²·24h) |
| Test Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional 5–55°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0%RH, 30–95%RH |
| Humidity Control Accuracy | ±1%RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 chambers (independent operation) |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–100 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 585 × 485 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz |
| Compliance | GB/T 21529-2008, YBB 00092003-2015, BS EN ISO 15106-3:2005, ASTM E398-2013, DIN 53122-2 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AKF-V6 |
| Pricing | USD 6,800 (FOB Shanghai) |
| Titration Mode | Fully Automated Volumetric Titration |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Volumetric & Coulometric Capable via Optional Module) |
| Measurement Resolution | 0.1 ppm |
| Water Content Range | 10 ppm – 100% (0.001% – 100% H₂O) |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (with 20 mL burette) |
| Repeatability | ≤ 0.3% RSD |
| Linearity Correlation Coefficient | ≥ 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Control Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records (expandable via USB export) |
| Brand | ICT International |
|---|---|
| Country of Origin | Australia |
| Model | MPKit (comprising MP406 sensor and MPM160 meter) |
| Measurement Principle | Time-Domain Transmission (TDT) via high-frequency electromagnetic wave propagation |
| Measurement Range | 0–100% volumetric water content (VWC) |
| Accuracy | ±1% VWC (soil-specific calibration), ±5% VWC (generic mineral soil calibration) |
| Response Time | <0.5 s |
| Probe Preheat Time | 3 s |
| Ingress Protection | IP68 (fully sealed, permanently embeddable) |
| Probe Dimensions | 60 mm active length, 4 mm radius, stainless steel 316 body |
| Total Probe Length | 215 mm |
| Cable Standard | 4.5 m (extendable up to 100 m) |
| Readout Meter Display | 16-character LCD, showing battery status, raw mV output (0–1200 mV), calibrated VWC, and unit indicators |
| Resolution | 0.1% VWC |
| Data Storage | 1 MB flash memory (~1024 readings) |
| Interface | RS-232 + USB download cable |
| Software | Windows-based ICT Data Manager (CSV export supported) |
| Sleep Current | 1 µA |
| Accessories Included | Stainless steel extension rod (enables 80 cm depth measurement), rugged ABS plastic carrying case |
| Compliance | Designed for field-deployable GLP-aligned environmental monitoring |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Model | HT-350 |
| Measurement Principle | High-frequency electromagnetic wave (radio frequency, 1–10 MHz) |
| Moisture Range | 0–80% w/w |
| Accuracy | ±(0.5% of reading + 1%) |
| Resolution | 0.1% |
| Response Time | 1 second |
| Operating Temperature | −10 °C to 50 °C |
| Operating Humidity | 35–85% RH |
| Display | 4-digit LCD with backlight |
| Power Supply | 4 × AAA batteries |
| Dimensions (main unit) | 140 mm × 60 mm × 24 mm |
| Sensor Probe Length | Standard 235 mm (custom lengths available) |
| Net Weight | ~120 g |
| Compliance | Designed for industrial QC environments |
| Brand | KETT |
|---|---|
| Origin | Japan |
| Model | RN-300 |
| Heating Method | Infrared |
| Sample Type | Brown Rice & Polished Rice (polished rice analysis requires optional accessories) |
| Image Sensor | Color CCD Camera |
| Light Source | White Cold-Cathode Fluorescent Lamp |
| Maximum Sample Capacity | 1,148 grains per measurement |
| Analysis Time | Approx. 24 seconds |
| Display | Grain-by-grain classification, count, percentage composition (by number and mass), length/width/projection area, typicality index, embryo retention rate (0 / ½ / full), crack detection |
| Power Supply | AC 100 V ±10%, 50/60 Hz |
| Dimensions (Transport) | 580 × 230 × 420 mm |
| Dimensions (Operation) | 840 × 580 × 115 mm |
| Weight | ~12 kg |
| Brand | KEWLAB |
|---|---|
| Model | MA113TA |
| Heating Source | Halogen Lamp |
| Capacity | 110 g |
| Readability | 0.001 g / 0.01% |
| Repeatability | ±0.002 g |
| Temperature Range | 40–230 °C |
| Timer Range | 1–99 min |
| Operating Environment | 5–35 °C |
| Interface | RS232, RJ45 Ethernet |
| Display | Large Capacitive Touchscreen |
| Power Supply | 220 V / 50 Hz |
| Dimensions (L×W×H) | 215 × 195 × 415 mm |
| Sample Pan Material | Precision Cast Aluminum |
| Chamber Material | Multi-layer Stainless Steel |
| Cooling | Dual Fan System |
| Connectivity | Wired (TA series) |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | KLY-2 |
| Pricing | Upon Request |
| Product Type | Portable Dew Point Meter |
| Measurement Range | –80 to +20 °C dew point (approx. 0.5–23,632 µL/L H₂O) |
| Accuracy | ≤±0.5 °C (at factory calibration) |
| Response Time | <30 s (63%), <60 s (90%) for rise at DP < –40 °C |
| Output Signal | 4–20 mA analog |
| Operating Media Conditions | Gas temperature < +60 °C, pressure < 2 MPa, flow rate 200 mL/min |
| Dimensions | 260 mm × 170 mm × 300 mm (W×H×D) |
| Brand | KPM Sensortech |
|---|---|
| Origin | USA |
| Model | PMT-330 |
| Type | Capacitance-Based RF Moisture Analyzer |
| Application | Non-Destructive In-Line and Spot Measurement in Lumber, Plywood, Particleboard, Corrugated Paperboard, and Gypsum Wallboard |
| Compliance | Meets ASTM D4442 (Wood), ISO 8781-3 (Paper & Board), and ASTM C117 (Gypsum) moisture test method principles |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001% (10 ppm) to 100% |
| Power Supply | AC 220 V ±10%, 50 Hz ±2.5 Hz |
| Data Storage | Automatic storage of up to 1,000 test records |