Moisture Analyzer
Filter
Showing 121–150 of 676 results
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DMS-4KEA |
| Price | USD 2,150 (FOB Shanghai) |
| Heating Method | Halogen Lamp |
| Weighing Range | 0–110 g |
| Weighing Accuracy | ±0.001 g |
| Moisture Determination Range | 0.001–100% |
| Temperature Control Range | 40–200 °C |
| Typical Measurement Time | ≤8 min |
| Display | 7-inch capacitive touchscreen |
| Language Support | English & Chinese |
| Built-in Functions | Auto-tare, one-touch preheat, temperature calibration, label printing, silent cooling fan, dual-drive automatic door opening |
| Optional Connectivity | Bluetooth 5.0 & Wi-Fi 802.11 b/g/n |
| User Management | Administrator & operator accounts with password protection |
| Internal Calibration | Scheduled interval setting with audit trail |
| Compliance | ASTM D4052, ISO 1183, USP <921>, GB/T 29246–2012 |
| Brand | Deleite |
|---|---|
| Origin | Shanghai, China |
| Model | DR-506 |
| Measurement Principle | Microbial Electrode Method |
| Standard Compliance | HJ/T 86–2002 |
| Measuring Range | 2–50 mg/L (up to 4000 mg/L with dilution) |
| Repeatability | ≤10% RSD |
| Accuracy | ±5% of reading |
| Resolution | 0.1 mg/L |
| Sample Throughput Time | 5–8 min per sample |
| Sample Volume Required | 50 mL per assay |
| Flow Rate | Constant-flow continuous injection (5 mL/min buffer consumption) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 100 W |
| Dimensions (W×D×H) | 560 × 360 × 210 mm |
| Net Weight | 16 kg (shipping weight ~20 kg) |
| Sample Handling | No pretreatment required |
| Microbial Sensor | Non-pathogenic, immobilized nitrifying bacteria strain |
| Data Output | Integrated thermal printer |
| Brand | Deleite |
|---|---|
| Origin | Shanghai, China |
| Model | HE100-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability | ±0.30% (with 3 g sample) |
| Temperature Range | 40–180 °C |
| Heating Time | 1–99 min (1 min increments) |
| Sample Pan Diameter | 100 mm |
| Communication Interface | RS232 |
| Displayed Parameters | % Moisture, % Solids, Time, Temperature, Weight, Date |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | C2010 |
| Price | USD 2,650 (approx.) |
| Transmitter | Vaisala HUMICAP® Humidity Sensor |
| Dew Point Range | –100 to +20 °C or –60 to +60 °C |
| Power Supply | 12–28 VDC |
| Output Signal | 4–20 mA (linear, full-scale span) |
| Interchangeability | Fully interchangeable transmitter modules |
| Accuracy | ±2 °C dew point (within calibrated range) |
| Operating Temperature | –40 to +60 °C |
| Temperature Compensation | Integrated digital temperature compensation |
| Maximum Working Pressure | 30 MPa |
| Flow Rate (Standard Sampling System) | 1–5 L/min |
| Flow Rate (Direct-Insertion Mode with 80 µm Sintered Filter) | 0–10 Nl/min |
| Traceability | Calibrated against NPL (UK) and NIST (US) standards for –75 to +20 °C dew point |
| Fault Indication | 23 mA (transmitter fault), 4 mA (below lower limit), 20 mA (above upper limit) |
| Brand | Denver |
|---|---|
| Origin | USA |
| Model | IR-120 |
| Weighing Range | 120 g |
| Readability | 0.1 mg |
| Moisture Resolution | 0.0001% |
| Repeatability | ±0.1% (≥1 g sample), ±0.02% (≥5 g sample) |
| Heating Temperature Range | 30–230 °C (1 °C increments) |
| Heating Modes | Standard, Rapid, Gentle, Step (3-stage, 0.1–999 min per stage) |
| Pre-stored Methods | 30 |
| Built-in Calibration Weight | Yes |
| GLP-Compliant Printing | Yes |
| Interface | RS-232C |
| Dimensions (W×D×H) | 350 × 453 × 156 mm |
| Weight | 8.0 kg |
| Brand | Denver |
|---|---|
| Origin | USA |
| Model | IR-35 |
| Maximum Sample Capacity | 35 g |
| Readability | 0.01% moisture |
| Sensor Resolution | 1 mg |
| Repeatability | ±0.2% (for 1–5 g initial sample), ±0.05% (for ≥5 g) |
| Heating Range | 40–160 °C (adjustable in 1 °C increments) |
| Heating Source | Long-life infrared metal tube heater with integrated reflector |
| Shut-off Modes | Automatic endpoint detection and timer mode (0.1–99 min) |
| Display Modes | % moisture, % dry weight, % ratio, residual mass (g) |
| Sample Chamber | Top-hinged lid with wide opening angle |
| Compliance | FDA/HACCP-compliant aluminum viewing panel (replaces glass), GLP-compliant reporting via RS-232C interface |
| Dimensions (W×D×H) | 224 × 366 × 191 mm |
| Net Weight | 5.8 kg |
| Data Storage | Single user-defined method |
| Interface | RS-232C for printer or PC connectivity |
| Brand | Denver |
|---|---|
| Origin | USA |
| Model | IR-60 |
| Maximum Sample Capacity | 60 g |
| Readability | 1 mg / 0.01% moisture |
| Repeatability | ±0.2% (for 1–5 g initial sample), ±0.05% (for ≥5 g initial sample) |
| Heating Range | 40–210 °C (1 °C increments) |
| Heating Source | Quartz infrared heater with quartz reflector plate |
| Programmable Heating Time | 0.1–99.9 min |
| Stored Methods | 5 user-defined protocols |
| Sample Pan Diameter | 90 mm |
| Calibration Weight | 50 g (E2 class) |
| Interface | RS-232C |
| Dimensions (W×D×H) | 213 × 320 × 181 mm |
| Net Weight | 5.1 kg |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DEWRanger DUO |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Dual-Ceramic Nanofilm Capacitive Sensor |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±2 °C |
| Repeatability | 0.5 °C |
| Dew Point Range | −100 °C to +20 °C |
| Flow Rate | 1–5 L/min |
| Gas Connection | 6 mm Push-to-Connect Fitting |
| Tubing | 6 mm PTFE |
| Max Operating Pressure | 3 MPa (Swagelok-compatible) |
| Display | Backlit LCD |
| Output | 4–20 mA Analog |
| Power Supply | Rechargeable Li-ion Battery |
| Enclosure | Yellow Polypropylene Housing |
| IP Rating | IP67 |
| Calibration Certificate | Traceable to NIST/PTB Standards |
| Dimensions (W×H×D) | 270 × 174 × 246 mm |
| Weight | 4.4 kg |
| Brand | Dickey-john |
|---|---|
| Origin | USA |
| Model | GAC2500INTL |
| Measurement Principle | 149 MHz Radio Frequency Capacitance |
| Sample Form | Whole-grain (no grinding required) |
| Measurement Time | ≤10 seconds per sample |
| Accuracy (Moisture) | ±0.2% w.b. vs. AOAC 985.17 reference method |
| Compliance | NTEP Certified (Class III, Certificate #19-063), compliant with USDA FGIS and ISO 712:2017 |
| Calibration Transfer | Compatible with GAC2100 calibration files |
| Interface | 7-inch color TFT capacitive touchscreen |
| Data Storage | Internal memory for ≥10,000 test records with timestamp, grain type, moisture, test weight, temperature |
| Optional Accessories | Through-type sample drawer, external USB mouse & keyboard, RS-232/USB data export |
| Brand | DKS |
|---|---|
| Origin | Germany |
| Model | AQUATRACE |
| Detection Limit | 0.05 vppm |
| Measurement Range | 0–2000 vppm |
| Resolution | 0.1 vppm |
| Accuracy | ±5% of reading (≥0.4 vppm) |
| Response Time (T10–T90) | <1 s (moisture event), ≤2 min (return to baseline) |
| Reproducibility | ±2% at 20.0 vppm |
| Measuring Gas Flow | 20 Nl/h |
| Gas Temperature Range | +5 to +65 °C |
| Max. Gas Pressure | 200 mbar g |
| Sensor Body Material | PVDF & stainless steel |
| Sensor Electrode Material | Noble metal |
| Analog Output | 4–20 mA (freely scalable) |
| Alarm Output | Relay (NO/NC), freely scalable |
| Status Relays | 3 × NAMUR-compliant |
| Gas Inlet | 6 mm locking ring |
| Cell Connector | 5-pole Binder plug |
| Standard Cable Length | 1.5 m (max. 100 m) |
| Auto Sensor Detection & Self-Check Function | Yes |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DSH-50A |
| Max Capacity | 50 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Temperature Range | 50–180 °C |
| Heating Time Setting | 1–99 min (1-min increments) |
| Heating Source | Halogen lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Interface | RS-232C |
| Display | Backlit dot-matrix LCD |
| End-point Detection | Timer-based & automatic moisture stabilization algorithm |
| Brand | EasyTest |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | FOM/mts |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Volumetric Water Content Range | 0–100% |
| Temperature Range | −20 to +50 °C |
| Bulk Electrical Conductivity Range | 0.000–1 S/m |
| VWC Accuracy | ±2% of reading |
| Temperature Accuracy | ±0.5 °C |
| EC Accuracy | ±0.01 S/m |
| VWC Resolution | 0.1% |
| Temperature Resolution | 0.1 °C |
| EC Resolution | 0.001 S/m |
| Measurement Time | <5 s |
| Operating Temperature | 0–50 °C |
| Dimensions | 180 × 85 × 58 mm |
| Weight | 0.35 kg (with battery) |
| Display | 160 × 128 pixel monochrome LCD |
| Pulse Shape | sin² waveform |
| Rise Time | 200 ps |
| Data Storage | 1,000 labeled measurements |
| Battery | 3.6 V, 1600 mAh Li-ion (no memory effect, auto-charging with overcharge protection) |
| Cable Length Options | 1.5–6.0 m |
| Storage Temp. | −10 to +50 °C |
| Maintenance Interval | Recharge every 3–4 months |
| Brand | EdgeTech |
|---|---|
| Origin | USA |
| Model | DPS |
| Type | Online Dew Point Meter |
| Principle | Chilled-Mirror Condensation |
| Operating Temperature Range | 20–99 °C |
| Accuracy | ±0.2 °C |
| Repeatability | ±0.05 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PM8202 I |
| Measurement Range | 0.00–20,000 ppm Ca²⁺ |
| Resolution | 0.0 / 0.1 / 1 ppm (selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for hardness or temperature) |
| Enclosure Rating | IP67-rated sealed housing |
| Electrode | BSENS740 calcium-selective electrode (solid-state, polymer membrane) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CMH-01 |
| Application | Laboratory-grade dew point measurement |
| Principle | Chilled-mirror hygrometry |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.2 °C dew point |
| Repeatability | ±0.1 °C dew point |
| Measurement Range (at 101.3 kPa) | −70 to +20 °C dew point (dependent on ambient temperature) |
| Cooling Capacity | >95 °C differential (4-stage Peltier) |
| Gas Flow Rate | 15–60 L/h (typical: 25–30 L/h) |
| Sample Pressure Range | 1 kPa–1 MPa |
| Display | 320×240 true-color TFT LCD |
| Power Supply | 20 V DC / 6.0 A (host) |
| Battery Life | >8 h continuous operation |
| Dimensions | 320 × 330 × 150 mm |
| Weight | ~4 kg |
| Brand | EONTECH |
|---|---|
| Origin | Beijing, China |
| Model | MT 1000 |
| Measurement Principle | Electrolytic Method |
| Operating Temperature | -10°C to +50°C |
| Accuracy | ±1% of full scale |
| Range Options | 0–10 / 0–100 / 0–1000 / 0–2500 ppm (user-selectable) |
| Resolution | 0.1 ppm |
| Display | Touchscreen LCD |
| Alarm Outputs | 2 relay outputs |
| Analog Output | 4–20 mA |
| Power Supply | 220 VAC, 50–60 Hz + internal rechargeable Li-ion battery |
| Power Consumption | 8 W |
| Enclosure Rating | IP65 |
| Dimensions (Analyzer) | 340 × 290 × 220 mm |
| Weight (Analyzer) | ~3 kg |
| Sensor Model | TMS-H/P/100 |
| Sensor Housing Material | Hastelloy |
| Electrode Material | Platinum |
| Electrolyte | Phosphoric acid (H₃PO₄) membrane |
| Sample Flow Rate | 100 NL/h |
| Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | +5°C to +150°C (recommended ≤50°C) |
| Sensor Response Time (T₅₀) | <8 s |
| Detection Limit | 0.1 ppm |
| Sealing Material | FEP |
| Gas Fitting | 6 mm compression fitting |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Electrical Connector | LEMO waterproof |
| Sensor Mounting | Vertical via three M4 screws |
| Sensor Dimensions | Ø43 × 120 mm |
| Sensor Weight | ~1.15 kg |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-2S |
| Titration Mode | Fully Automated |
| Method Type | Dual-Mode (Coulometric & Volumetric Karl Fischer) |
| Measurement Resolution | 0.01 μA |
| Water Content Range | 0.01 mg to 100% w/w |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | 0.1 μA |
| Drift Compensation | Automatic background drift correction (drift <5 µg H₂O/min) |
| Detection Limit | 0.01 mg H₂O |
| Sample Forms | Liquids, solids, gases, pastes |
| Display & Interface | Bilingual (Chinese/English) LCD with real-time titration curve visualization |
| Data Output | GLP/GMP-compliant report formats (%, ppm, mg), statistical analysis capability |
| Software | Embedded titration monitoring software with firmware upgrade support |
| Compliance | Designed for ISO 8533, ASTM E203, USP <921>, and EP 2.5.12 environments |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-3S |
| Titration Mode | Fully Automatic |
| Method Principle | Volumetric & Coulometric Karl Fischer Titration |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ±10 ppm |
| Minimum Dispensing Volume | 0.1 µL (1/20000 of burette volume) |
| Titration Control Precision | 0.1 µL |
| Polarization Voltage Output | 0–2550 mV (10 mV step, <±3% error) |
| Max Polarization Current | 5 mA |
| Current Range | 0–200 µA |
| Effective Current Accuracy | ±0.1 µA |
| Drift Compensation | Auto/manual background subtraction |
| Data Output Compliance | GLP/GMP-compliant reporting format |
| Interface | RS-232C (printer & PC connection) |
| Method Storage | 100 protocols |
| Optional | Dead-stop titration capability with accessory kit |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZDJ-600S |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ≤0.2% RSD |
| Minimum Dispensing Volume | 5 µL |
| Burette Precision | 1/20,000 |
| Burette Capacity | 10 mL (standard) |
| Burette Accuracy | ±10 µL @ 10 mL |
| Polarization Current Range | 0–200 µA |
| Polarization Voltage Range | 0–2550 mV |
| Polarization Voltage Step | 10 mV |
| Effective Current Accuracy | Better than ±0.1 µA |
| Repeatability (Pure Water) | <1% RSD |
| Standardization Repeatability | ±0.5% of mean across three consecutive runs |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-106RF / GMK-107RF |
| Measurement Principle | Capacitance Method |
| Accuracy | ±0.5% w/w |
| Resolution | 0.1% w/w |
| Response Time | 1.5 s |
| Sample Volume | ~180 mL |
| Display | Large LCD |
| Temperature Compensation | Automatic |
| Auto Power-Off | After 3 min inactivity |
| Power Supply | 9 V DC (1 × 9 V battery) |
| Dimensions (Instrument) | 150 W × 230 L × 56 H mm |
| Sample Cup Dimensions | 143 H × 75 Ø mm |
| Net Weight | 3 kg |
| Grain-Specific Calibration Ranges | GMK-106RF — Soybean (large): 6.0–30.0%, Soybean (small): 7.0–30.0%, Peanut: 5.0–20.0%, Mung Bean: 7.0–20.0%, Rice: 12.5–22.5%, Paddy: 8.0–32.0%, Corn: 8.0–32.0% |
| GMK-107RF — Millet | 7.0–30.0%, Pea: 9.7–21.5%, Rapeseed: 7.0–20.0%, Rye: 9.8–25.0%, Barley: 7.0–30.0%, Wheat: 7.0–30.0%, Corn: 7.0–30.0% |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-303 |
| Measurement Range (Rice) | 8.3–26.0% |
| Measurement Range (Brown Rice) | 8.3–36.0% |
| Measurement Range (Paddy) | 8.5–40.0% |
| Measurement Range (Wheat) | 8.5–35.0% |
| Measurement Range (Barley) | 8.3–35.0% |
| Measurement Range (Raw Wheat) | 8.5–35.0% |
| Accuracy | ±0.5% w/w |
| Display | Digital LCD |
| Temperature Compensation | Automatic |
| Power Supply | 4 × 1.5 V AA batteries |
| Dimensions | 164 × 94 × 40 mm |
| Weight | ~1.5 kg |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-303A |
| Measurement Principle | Capacitance Method |
| Sample Types | Rice, Paddy, Dried Paddy, Soybean, Barley, Wheat, Corn/Maize |
| Moisture Range (by crop) | Rice: 8.3–26.0% |
| Paddy | 8.5–40.0% |
| Dried Paddy | 6.8–29.8% |
| Soybean | 8.5–21.5% |
| Barley | 8.3–35.0% |
| Wheat | 8.5–35.0% |
| Corn/Maize | 8.7–22.8% |
| Accuracy | ±0.5% w/w |
| Display | Digital LCD |
| Temperature Compensation | Automatic |
| Power Supply | 4 × 1.5 V AA batteries |
| Dimensions | 164 × 94 × 40 mm (L × W × H) |
| Weight | ~1.5 kg |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-303C |
| Measurement Principle | Capacitance Method |
| Sample Type | Whole or Ground Coffee Beans |
| Moisture Range | 6.5–21.0% w/w |
| Resolution | 0.1% |
| Accuracy | ±0.5% |
| Measurement Time | ~3 seconds |
| Temperature Compensation | Automatic |
| Calibration | Auto-calibration with built-in reference protocol |
| Display | Backlit LCD |
| Power Supply | 4 × 1.5 V AA batteries |
| Dimensions | 164 × 94 × 40 mm (L×W×H) |
| Weight | ~1.8 kg |
| Data Handling | Auto-save, Auto-power-off |
| Interface | Touch-sensitive keypad |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-303CF |
| Measurement Principle | Capacitance Method |
| Display | Large LCD with Digital Readout |
| Temperature Compensation | Automatic |
| Calibration | Auto-Calibration Routine Prior to Each Measurement |
| Power Supply | 4 × 1.5 V AA Batteries |
| Accuracy | ±0.5% (w/w) |
| Dimensions | 164 × 94 × 40 mm |
| Weight | ~1.2 kg |
| Moisture Range (Coffee) | 6.5–23.5% |
| Rice | 8.3–26.0% |
| Paddy | 8.5–40.0% |
| Wheat | 8.5–35.0% |
| Soybean | 8.5–21.5% |
| Sunflower Seed | 4.5–13.5% |
| Maize/Corn | 8.7–22.8% |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-303F |
| Measurement Principle | Capacitance Sensing |
| Accuracy | ±0.5% |
| Display | Digital LCD |
| Temperature Compensation | Automatic |
| Power Supply | 4 × 1.5 V AA batteries |
| Dimensions | 164 × 94 × 40 mm (L × W × H) |
| Weight | ~1.2 kg |
| Grain-Specific Calibration Ranges | Chestnut (9.7–25.4%), Paddy Rice (8.5–30.0%), Peas (9.7–21.5%), Rye (9.8–25.0%), Soybean (8.5–21.5%), Wheat (8.5–30.0%), Corn (8.7–22.8%) |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-303RS |
| Measurement Principle | Capacitance Dielectric Method |
| Sample Types | Rice (8.3–26.0%), Paddy (8.5–40.0%), Soybean (8.5–21.5%), Red Bean (12.5–19.7%), Barley (8.3–35.0%), Wheat (8.5–35.0%), Corn/Maize (8.7–22.8%) |
| Accuracy | ±0.5% w.b. |
| Display | Digital LCD with Automatic Temperature Compensation |
| Power | 4 × 1.5 V AA batteries (low-battery indicator) |
| Dimensions | 164 × 94 × 40 mm |
| Weight | ~1.2 kg |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-305T |
| Measurement Range | 3.5–18.0% (w/w) |
| Accuracy | ±0.5% |
| Resolution | 0.1% |
| Temperature Compensation | Automatic |
| Display | LCD |
| Power | 4 × 1.5 V DC (AA batteries) |
| Dimensions | 220 × 148 × 60 mm (L×W×H) |
| Sample Chamber Diameter × Height | 80 × 130 mm |
| Weight | Approx. 2.0 kg |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-307C |
| Measurement Range | 4.0–15.8% w/w |
| Accuracy | ±0.5% |
| Resolution | 0.1% |
| Temperature Compensation | Automatic |
| Display | LCD (1.5 V DC × 4) |
| Dimensions | 220 × 148 × 60 mm (L×W×H) |
| Sample Chamber | Ø80 × 130 mm (D×H) |
| Weight | ~2.0 kg |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-308 NEW |
| Measurement Principle | Capacitance Dielectric Sensing |
| Target Matrices | Wheat flour, cassava starch, chili powder, sweet potato starch, potato starch, corn starch |
| Moisture Range (w/w%) | 8.5–23.5% (wheat), 10.5–23.0% (cassava), 8.5–21.5% (chili powder), 9.5–21.0% (sweet potato starch), 12.5–23.1% (potato starch), 13.5–22.7% (corn starch) |
| Resolution | 0.1% |
| Accuracy | ±0.5% |
| Power Supply | 4 × 1.5 V AA batteries |