| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-204-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low limit relays (user-definable) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC (Himsi) |
|---|---|
| Origin | Germany |
| Model | TMA-204-P-Ex |
| Type | Portable Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range | 0–10 / 100 / 1,000 / 2,500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual support (including Chinese) |
| Output | 0/4–20 mA (configurable) |
| Alarms | High/Low limit (user-definable) |
| Intrinsic Safety | Integrated Zener barrier (Ex ia IIC T4 Ga) |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-204-P-EX |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | -10 to 50 °C |
| Accuracy | ±0.2 °C dew point (equivalent to ±1% of full scale) |
| Repeatability | ±0.1 °C dew point |
| Detection Range | 0–10 / 100 / 1,000 / 2,500 ppmv H₂O (auto-ranging) |
| Display | Backlit LCD |
| Output | 4–20 mA or 0–10 V analog + 1 relay alarm |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-204-W |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.1% of Full Scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (Auto-ranging or Manual Selection) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Display | Touchscreen with Multilingual Interface (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 Relay Outputs |
| Enclosure Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Brand | CMC (Schimse) |
|---|---|
| Origin | Germany |
| Model | TMA-204-W-Ex |
| Product Type | In-line Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Intrinsic Safety | Integrated Zener barrier (Ex ia IIC T4 Ga) |
| Enclosure | IP65 |
| Dimensions | 300 × 260 × 280 mm (W × H × D) |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 ppmv |
| Repeatability | ±1 ppmv |
| Sample Flow Rate | 20 Nl/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature Range | 5–150 °C |
| T50 Response Time | <8 s |
| Environmental Operating Temperature | 5–65 °C |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Dimensions (Desktop) | 257 × 160 × 316 mm |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-D |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppmᵥ (auto-ranging) |
| Sensitivity | 0.1% of full scale |
| Response Time | <1 s (t₉₀) |
| Sample Flow Rate | 100 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| Ambient Temperature | 5–65 °C |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Enclosure Type | Benchtop (257 × 160 × 316 mm) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-210-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature Range | +5 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–2,500 ppm (auto/manual range switching) |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Alarm Outputs | Configurable high/low limit relays |
| Analog Output | 4–20 mA (user-configurable) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Environmental Operating Temp. | −10 °C to +50 °C |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1 ppm |
| Repeatability | ±0.1 ppm |
| Range | 0–10 / 100 / 1,000 / 2,500 ppm (Auto-ranging) |
| Sensitivity | ±0.1% of full scale |
| Display | Backlit LCD with multilingual interface (including English, German, French, Spanish, Chinese) |
| Alarm Output | 1 relay (SPDT) |
| Analog Output | 4–20 mA or 0–10 V (user-configurable) |
| Power Supply | Rechargeable NiMH battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-Ex |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to 50 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Measurement Range | 0–10 / 100 / 1,000 / 2,500 ppmv H₂O (auto-ranging) |
| Display | Backlit LCD |
| Output | 4–20 mA or 0–10 V analog + 1 relay alarm |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P-EX |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±1 ppm(v/v) |
| Repeatability | ±1 ppm(v/v) |
| Range | 0–10 / 100 / 1000 / 2500 ppm(v/v) (Auto-ranging) |
| Sensitivity | 0.1% of full scale |
| Display | Backlit LCD with multilingual interface (including English, German, French, Spanish, Chinese) |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Environmental Operating Range | 5–65 °C |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Dimensions (Portable Variant) | 257 mm (W) × 160 mm (H) × 316 mm (D) |
| Brand | CMC (Himsy) |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-Ex |
| Type | Portable Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | 5–150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual range switching) |
| Sensitivity | ±0.1% of full scale |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Alarm Outputs | High/Low configurable relay outputs |
| Analog Output | 0/4–20 mA (user-configurable) |
| Intrinsic Safety | Integrated Zener barrier |
| Power Supply | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Ambient Operating Temperature | −10 to +50 °C |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-IP54 |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | +5 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto-ranging or manual selection) |
| Response Time | <1 s |
| Sample Flow Rate | 100 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including English) |
| Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low limit relays (user-definable thresholds) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Enclosure | Portable aluminum-framed case, IP54 rated |
| Cable Length | Standard 3 m, optional up to 300 m |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P-ZB |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −5 to 50 °C |
| Accuracy | ±1 % of full scale |
| Repeatability | ±0.01 % of full scale |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppmᵥ (auto-ranging) |
| Sensitivity | 0.1 % of full scale |
| Response Time (T₉₀) | < 1 s |
| T₅₀ Response | < 8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| Ambient Temperature | 5–65 °C |
| Display | Multifunctional High-Resolution LCD |
| Analog Output | 4–20 mA |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Dimensions (Portable Version) | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P-ZB |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±1 ppmv |
| Repeatability | ±1 ppmv |
| Range | 0–10 / 100 / 1000 / 2500 ppmv (Auto-ranging) |
| Full-Scale Accuracy | ±1% FS |
| Sensitivity | 0.1% FS |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 Relay Outputs |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Total Response Time | <1 s |
| Ambient Operating Temperature | 5–65 °C |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Dimensions (Desktop) | 257 mm (W) × 160 mm (H) × 316 mm (D) |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-404 |
| Type | In-line Dew Point / Moisture Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–1 / 10 / 100 / 1000 ppmᵥ (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Power Supply | 80–230 VAC, 50–60 Hz |
| Enclosure Options | Rack-mount (482 × 133 × 350 mm), Wall-mount (300 × 260 × 280 mm), Bench-top (257 × 160 × 316 mm) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-100 |
| Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Flow Rate | 100 NL/h |
| Sample Gas Temperature Range | 5–50 °C |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Electrode Substrate | Hastelloy |
| Sensor Cell Housing | Borosilicate Glass |
| Sealing Material | FEP |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-100-P |
| Type | Portable Dew Point Meter |
| Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Gas Flow Rate | 100 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Measurement Cell Material | Hastelloy |
| Housing/Carrier Material | PEEK |
| Seal Material | FEP |
| Gas Inlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-20 |
| Type | Portable Dew Point Analyzer |
| Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Measuring Cell Material | Hastelloy |
| Electrode Material | Platinum |
| Substrate | Glass |
| Seal Material | FEP |
| Sample Gas Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-style compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-20-F |
| Type | Online Dew Point Analyzer |
| Principle | Electrolytic (P2O5) Sensor Technology |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Gas Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Measurement Cell Material | Hastelloy |
| Sensor Substrate | Borosilicate Glass |
| Seal Material | FEP (Fluorinated Ethylene Propylene) |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy C-276 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMS-SS-P-20 |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 ppmv |
| Repeatability | ±1 ppmv |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-SS-P-20 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Method |
| Operating Temperature | 5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sensor Cell Material | Stainless Steel |
| Electrode Material | Platinum |
| Substrate | Glass |
| Seal Material | Viton |
| Sample Gas Temperature Range | 5–50 °C |
| Flow Rate | 20 NL/h |
| Operating Pressure | 0.1–0.5 barg |
| Gas Inlet Fitting | 6 mm Swagelok®-style stainless steel compression fitting |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-SS-P-20-F |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Method |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sensor Cell Material | Stainless Steel |
| Electrode Material | Platinum |
| Substrate | Glass |
| Sealing Ring Material | Viton |
| Sample Gas Temperature Range | 5–50 °C |
| Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible stainless steel compression fitting |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | CMC-TM-H2O System |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Sample Flow Rate | 20 NL/h or 100 NL/h |
| Operating Pressure | 0.1–1.5 barg |
| Sensor Material Options | Stainless Steel, Monel 400, Hastelloy, Glass, PFA |
| Electrode Material | Platinum or Rhodium |
| Sealing Materials | Viton, FEP, or FFKM |
| Electrical Connector | LEMO waterproof |
| Enclosure Rating | IP20 (benchtop/rack), IP65 (wall-mount) |
| Power Supply | 80–230 VAC, 50/60 Hz |
| Power Consumption | 8 W |
| Dimensions (Analyzer) | 363 × 115 × 377 mm (portable), 482 × 133 × 350 mm (19″ rack), 300 × 260 × 280 mm (wall-mount), 257 × 160 × 316 mm (desktop) |
| Weight (Analyzer) | ~6 kg |
| Probe Dimensions | Ø43 × 120 mm |
| Probe Weight | ~300 g |
| Display | Backlit LCD |
| Output Signals | 4–20 mA / 0–20 mA / 0–10 V (user-configurable) |
| Digital Interface | RS232 |
| Relay Outputs | 2 alarm relays (230 VAC / 1 A), 5 range-indication relays |
| Input | 5 external relay contacts for range switching |
| Calibration | Automatic zero and span calibration at power-on |
| Response Time (T₅₀) | <8 s |
| Measurement Range (with TMA-202/204/210) | 0–10 / 100 / 1000 / 2500 ppmᵥ |
| Measurement Range (with TMA-404) | 0–1 / 10 / 100 / 1000 ppmᵥ |
| Environmental Operating Temp. | −10 °C to +50 °C |
| Sample Gas Temp. | +5 °C to +150 °C (recommended ≤50 °C |
| Ambient Temp. (Probe) | +5 °C to +65 °C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CMC-TW-H2O |
| Price Range | USD 14,000 – 28,000 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1 ppmv H₂O (in dry gas matrix) |
| Repeatability | ±1 ppmv H₂O |
| Sample Flow Rate | 20 NL/h (nominal) |
| Pressure Regulation | Dual-stage stainless steel pressure regulators (1.0 MPa inlet → 0.1 MPa sensor inlet) |
| Filtration | 320TP fully sealed PTFE membrane filter (0.1 µm pore size) |
| Drainage Architecture | Dual three-way valve + precision needle valve purge system for liquid water removal |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CT-3100 |
| Pricing | Available Upon Request |
| Sample Size | 10 mg–20 g |
| Resolution | 1 ppm (1 µg) |
| Moisture/Solids Range | 10 ppm (10 µg) to 100% |
| Heating Temperature Range | 25–275 °C |
| Stored Test Methods | 8 pre-programmed protocols |
| Compliance | ASTM D7191-05 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP305 |
| Pricing | Available Upon Request |
| Display | 5.0-inch color touchscreen (Chinese UI) |
| Measurement Principle | Photometric colorimetry based on Lambert-Beer law |
| Method Compliance | Chinese National Standard method using bis-cyclohexanone oxalyldihydrazone (BCO) reagent |
| Measurement Range | 0.00–200 μg/L |
| Accuracy | ±3% FS |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% FS / 4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | Cyclic memory for up to 256 test records |
| Calibration | Zero-point blank calibration and periodic calibration curve verification |
| Light Source | Imported monochromatic cold LED source |
| Circuit Design | High-integration SMT PCB architecture |
| Microcontroller | Advanced low-power embedded MCU |
| Environmental Compliance | Designed for industrial water chemistry labs per GB/T standards |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Type | Online Dew Point Analyzer |
| Accuracy | ±2% F.S. |
| Repeatability | ≤1.5% F.S. |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measurement Range | 0–6000 ppmv H₂O |
| Resolution | 0.1 ppmv |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Ingress Protection | IP66 |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Sample Pressure | Inlet: 140–310 kPa |
| Measurement Cell | 800–1200 mbara |
| Power Supply | 24 VDC ±20% or 100–240 VAC ±10%, 50/60 Hz, 10 W |
| Communication Interfaces | RS-485, 4–20 mA, Modbus RTU/TCP, Ethernet |
| Dimensions (L×W×H) | 400 × 400 × 250 mm |
| Weight | 36 kg |
| Brand | D&T |
|---|---|
| Origin | Tianjin, China |
| Model | EX-FH104A |
| Heating Source | Halogen Lamp |
| Weighing Range | 120 g |
| Readability | 0.1 mg |
| Repeatability (2 g sample) | 0.05% SD, ±0.1% |
| Repeatability (10 g sample) | 0.01% SD, ±0.05% |
| Moisture Readability | 0.001% MC |
| Calibration | Fully Automatic Internal Calibration |
| Drying Temperature Range | Single-Glass Mode: 40–160 °C |
| Dual-Glass Mode | 40–200 °C |
| Increment | 1 °C |
| Pan Diameter | Φ90 mm |
| Dimensions (W × D × H) | 200 × 385 × 120 mm |
| Moisture Range | 0.01–100% MC |
| Method Storage | 300 methods |
| Result Storage | 3000 records |
| Heating Programs | Standard, Stepwise, Rapid |
| Drying Termination Modes | Timed, Auto (5 preset weight-loss thresholds + user-defined threshold) |
| Warm-up Time | 20–30 min |
| Display Modes | %MC, %DC, g |
| Output Interfaces | RS232/RS485, LAN, USB1 (data export/firmware update), USB2 (dedicated printer) |
| Touchscreen | 7-inch capacitive |
| Sensor Type | Integrated electromagnetic force compensation sensor |
| Design | Separated weighing and display units |