Moisture Analyzer
Filter
Showing 61–90 of 676 results
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | CMC-TM-H2O |
| Product Type | In-Line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Brand | CMC |
|---|---|
| Origin | Beijing, China |
| Model | CMC-TW-H2O |
| Product Type | Online Dew Point Sampling System |
| Measurement Principle | Electrolytic (P₂O₅-based) |
| Operating Temperature | 40 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.5% of full scale |
| Sample Flow Rate | 20 or 100 NL/h |
| Operating Pressure | 0.1–1.5 barg |
| Sensor Material Options | Stainless Steel, Monel 400, Hastelloy, Glass, PFA |
| Electrode Material | Platinum or Rhodium |
| Seal Material Options | Viton, FEP, or FFKM |
| Gas Fitting | 6 mm or 1/4″ compression fitting |
| Electrical Connector | LEMO waterproof connector |
| Mounting | Vertical installation via three M4 screws |
| IP Rating | IP20 (benchtop/rack), IP65 (wall-mount) |
| Power Supply | 80–230 VAC, 50/60 Hz |
| Power Consumption | 8 W |
| Ambient Temperature Range | −10 °C to +50 °C |
| Enclosure Dimensions (benchtop) | 363 × 115 × 377 mm |
| Weight (instrument) | ~6 kg |
| Probe Dimensions | Ø43 × 120 mm |
| Probe Weight | ~300 g |
| Response Time (T₅₀) | <8 s |
| Calibration | Automatic zero and span calibration at startup |
| Output Signals | 4–20 mA / 0–20 mA / 0–10 V (user-selectable) |
| Digital Interface | RS232 |
| Relay Outputs | 2 alarm relays (230 VAC / 1 A), 5 range-indication relays, 5 external range-switching inputs |
| Display | Backlit LCD |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual support (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low (user-definable thresholds) |
| Power Supply | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 420 × 115 × 390 mm (W × H × D) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-202 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Ambient Temperature | 5–65 °C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Dimensions (W×H×D) | 258 × 168 × 325 mm |
| Weight | ~5 kg |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC (Schimse) |
|---|---|
| Origin | Germany |
| Model | iTMA-202-19" |
| Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 / 100 / 1,000 / 2,500 ppm H₂O (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual support (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Dimensions | 483 mm (W) × 135 mm (H) × 345 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-202-19"-Ex |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Operating Range | 5–65 °C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Intrinsic Safety | Integrated Zener barrier |
| Enclosure | 19" rack-mount (482 mm W × 133 mm H × 350 mm D) |
| Cable Length | Standard 3 m, optional up to 300 m |
| Brand | CMC (Himsi) |
|---|---|
| Origin | Germany |
| Model | iTMA-202-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10, 0–100, 0–1000, 0–2500 ppm H₂O (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with optional Chinese language support |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low alarm (user-definable thresholds) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-202-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5°C to +50°C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Brand | CMC (Schimse) |
|---|---|
| Origin | Germany |
| Model | iTMA-202-W-Ex |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 / 100 / 1,000 / 2,500 ppm H₂O (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Intrinsic Safety | Integrated Zener barrier |
| Enclosure Rating | Ex d IIC T6 Ga (ATEX/IECEx certified) |
| Dimensions | 310 × 250 × 285 mm (W × H × D) |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204 |
| Product Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (auto/manual range switching) |
| Response Time (T₅₀) | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Operating Range | 5–65 °C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Dimensions (Desktop Unit) | 258 × 168 × 325 mm (W × H × D) |
| Weight | ~5 kg |
| Cable Standard | 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-19" |
| Product Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10°C to +50°C |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.1% of Full Scale |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Dimensions | 310 mm (W) × 250 mm (H) × 285 mm (D) |
| Cable Length | Standard 3 m, up to 300 m optional |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-W-Ex |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Rating | ATEX/IECEx certified for Zone 1/21 (Ex d ia IIC T4 Ga / Ex tD A21 IP66 T80°C) |
| Dimensions | 310 × 250 × 285 mm (W × H × D) |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-210-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppm (auto/manual range switching) |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Output | 4–20 mA analog, high/low alarm relay |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 420 × 115 × 390 mm |
| Weight | ~6 kg |
| Brand | CMC (Schimse GmbH) |
|---|---|
| Origin | Germany |
| Model | iTMA-210-P-Ex |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10, 0–100, 0–1000, 0–2500 ppm (auto/manual switching) |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Output | 4–20 mA analog, high/low alarm relay |
| Power | Rechargeable Li-ion battery or 80–230 VAC / 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 420 × 115 × 390 mm |
| Weight | ~6 kg |
| Intrinsic Safety | Integrated Zener barrier compliant with ATEX/IECEx Zone 1 requirements |
| Brand | CMC (Schimse) |
|---|---|
| Origin | Germany |
| Model | TMA-102-19" |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 to 50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual range switching) |
| Power Supply | 80–230 VAC, 50–60 Hz |
| Analog Output | 4–20 mA / 0–20 mA / 0–10 V (selectable) |
| Alarm Output | 1 relay output |
| Enclosure | 19" rack-mount chassis, IP20 |
| Dimensions | 445 mm × 88 mm × 308 mm (W × H × D) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-202 |
| Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | -20–80 °C |
| Accuracy | ±0.2 ppm(v) |
| Repeatability | ±0.1 ppm(v) |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppm(v), auto-ranging |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature Range | 5–150 °C |
| Ambient Temperature | 5–65 °C |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Cable Length | Standard 3 m, up to 300 m optional |
| Dimensions (Rack-mount) | 482 × 133 × 350 mm |
| (Wall-mount) | 300 × 260 × 280 mm |
| (Desktop) | 257 × 160 × 316 mm |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-202 |
| Application | Online dew point measurement in corrosive and combustible gases |
| Principle | Phosphorus pentoxide (P₂O₅) electrolytic sensor |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Operating Range | 5–65 °C |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Display | Touchscreen with optional Chinese language interface |
| Enclosure Options | 19" rack-mount (482 × 133 × 350 mm), wall-mount (300 × 260 × 280 mm), benchtop (257 × 160 × 316 mm), and ATEX-certified variants (TMA-202-Ex series) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-202-19 |
| Price Range | USD 13,500–27,000 (FOB) |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 ppmv (H₂O) |
| Repeatability | ±1 ppmv (H₂O) |
| Measurement Range | 0–10 / 0–100 / 0–1000 / 0–2500 ppmv (Auto-ranging) |
| Full-Scale Accuracy | ±1% FS |
| Sensitivity | 0.1% FS |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V (isolated) |
| Alarm Outputs | 2 SPDT relays (configurable) |
| Sample Flow Rate | 20 Nl/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| T₉₀ Response Time | <1 s |
| T₅₀ Response Time | <8 s |
| Ambient Operating Temperature | 5–65 °C |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Dimensions (Rack Mount) | 482 × 133 × 350 mm (W×H×D) |
| Dimensions (Wall Mount) | 300 × 260 × 280 mm |
| Dimensions (Desktop) | 257 × 160 × 316 mm |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-202-19" |
| Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10°C to +50°C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50°C |
| Ambient Temperature | 5–65°C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Dimensions | 482 mm (W) × 133 mm (H) × 350 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-202-W |
| Application | Laboratory-grade dew point analyzer for trace moisture in aggressive and inert gases |
| Principle | Phosphorus pentoxide (P₂O₅) electrolytic sensor |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–10 / 0–100 / 0–1000 / 0–2500 ppmv (auto-ranging) |
| Response Time (T₅₀) | <8 s |
| Sample Flow Rate | 20 NL/h or 100 NL/h |
| Sample Pressure | 0.1–1.5 barg |
| Sensor Materials | 316 stainless steel, Monel 400, Hastelloy, glass, PFA |
| Electrode Material | Platinum or rhodium |
| Sealing | Viton, FEP, or FFKM |
| Electrical Interface | LEMO waterproof connector |
| Enclosure Rating | IP20 (portable/desktop/rack-mount), IP65 (wall-mount) |
| Power Supply | 80–230 VAC, 50/60 Hz |
| Power Consumption | 8 W |
| Dimensions (Portable) | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Probe Dimensions | Ø43 × 120 mm |
| Probe Weight | ~300 g |
| Analog Output | 4–20 mA / 0–20 mA / 0–10 V (user-configurable) |
| Digital Interface | RS232 |
| Alarm Outputs | 2 relay outputs (230 VAC / 1 A max) |
| Range Indication Outputs | 5 relay outputs |
| External Range Control Inputs | 5 non-isolated or isolated dry contacts |
| Auto-zero & span calibration | Yes |
| NAMUR-compliant | Yes |
| Intrinsic safety option | Integrated Zener barrier available |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-202-W |
| Product Type | Online Dew Point Analyzer |
| Operating Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +50 °C |
| Accuracy | ±1 ppm(v) |
| Repeatability | ±1 ppm(v) |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppm(v) (Auto-ranging) |
| Full-Scale Accuracy | ±1% FS |
| Sensitivity | 0.1% FS |
| Display | Backlit LCD with Multilingual Interface (including Chinese) |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 Relay Outputs |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature Range | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Total Response Time | <1 s |
| Ambient Temperature Range | 5–65 °C |
| Cable Length | Standard 3 m, up to 300 m optional |
| Enclosure Options | Rack-mount (482 × 133 × 350 mm), Wall-mount (300 × 260 × 280 mm), Bench-top (257 × 160 × 316 mm) |
| Power Supply | NiMH Battery (replacing legacy lead-acid), Extended Runtime |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-202-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (auto/manual switching) |
| Sensitivity | 0.1% of full scale |
| Analog Output | 4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| T₅₀ Response Time | <8 s |
| Ambient Temperature Range | 5–65 °C |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Brand | CMC (Schimse) |
|---|---|
| Origin | Germany |
| Model | TMA-202-W-Ex |
| Product Type | In-line Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Temperature Range | 5–65 °C |
| Display | Touchscreen with optional Chinese language interface |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Intrinsic Safety | Integrated Zener barrier (Ex ia IIC T4 Ga) |
| Enclosure | IP65 |
| Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-202-W-EX |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 ppmv |
| Repeatability | ±1 ppmv |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppmv (Auto-ranging) |
| Full-Scale Accuracy | ±1% FS |
| Sensitivity | 0.1% FS |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Sample Flow Rate | 20 Nl/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Total Response Time | <1 s |
| Ambient Temperature Range | 5–65 °C |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Enclosure Options | Rack-mount (482 × 133 × 350 mm), Wall-mount (300 × 260 × 280 mm), Desktop (257 × 160 × 316 mm) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | TMA-202-ZB |
| Product Type | Portable Dew Point Analyzer |
| Operating Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +50 °C |
| Accuracy | ±1 ppm |
| Repeatability | ±0.1 ppm |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (Auto-ranging) |
| Full-Scale Accuracy | ±1% of reading |
| Sensitivity | ±0.1% of full scale |
| Display | Backlit LCD |
| Alarm Output | 1 relay (SPDT) |
| Analog Output | 4–20 mA or 0–10 V (user-configurable) |
| Power Supply | Internal rechargeable lead-acid battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions (W×H×D) | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-204 |
| Product Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.1% of Full Scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (Auto- or Manual-Range Selection) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with Multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 Relay Outputs |
| Enclosure Options | 19" Rack-Mount (482 × 133 × 350 mm), Wall-Mount (300 × 260 × 280 mm), Benchtop (257 × 160 × 316 mm), ATEX/IECEx Certified Variants Available |
| Cable Length | Standard 3 m, Optional up to 300 m |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-204-P |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 ppm(v) |
| Repeatability | ±1 ppm(v) |
| Range | 0–10 / 100 / 1000 / 2500 ppm(v) (Auto-ranging) |
| Sensitivity | 0.1% of full scale |
| Display | Backlit LCD |
| Analog Output | 0/4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Sample Flow Rate | 20 Nl/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Full Response Time | <1 s |
| Ambient Temperature Range | 5–65 °C |
| Cable Length | Standard 3 m, up to 300 m optional |
| Dimensions (Rack-mount) | 482 × 133 × 350 mm |
| Dimensions (Wall-mount) | 300 × 260 × 280 mm |
| Dimensions (Bench-top) | 257 × 160 × 316 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-204-P |
| Product Type | Online Dew Point Analyzer |
| Operating Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −5 to 50 °C |
| Accuracy | ±0.1 ppm (v/v) |
| Repeatability | ±0.5% of reading |
| Measurement Range | 0–10 / 0–100 / 0–1000 / 0–2500 ppm (v/v), auto-ranging |
| Full-Scale Accuracy | ±1% FS |
| Sensitivity | 0.1% FS |
| Analog Output | 4–20 mA or 0–10 V DC |
| Alarm Outputs | 2 SPDT relays |
| Display | Backlit LCD |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature Range | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Ambient Temperature Range | 5–65 °C |
| Cable Length | Standard 3 m, up to 300 m optional |
| Enclosure Options | 19″ rack-mount (482 × 133 × 350 mm), wall-mount (300 × 260 × 280 mm), benchtop (257 × 160 × 316 mm) |
| Brand | CMC (Himsy) |
|---|---|
| Origin | Germany |
| Model | TMA-204-P |
| Type | Portable Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 to 50 °C |
| Accuracy | ±0.2 °C dew point |
| Repeatability | ±0.1 °C dew point |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppmv H₂O (auto-ranging) |
| Sensitivity | ±0.1% of full scale |
| Display | Backlit LCD |
| Output | 1x 4–20 mA or 0–10 V analog output, 1x alarm relay |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |