| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-310 |
| Measurement Principle | Capacitive (not resistive — corrected per industry standard classification for GMK-310) |
| Moisture Range (Capsicum) | 8.0–27.5% w/w |
| Accuracy | ±0.5% w/w |
| Display | LCD |
| Power | 4 × 1.5 V AA batteries |
| Dimensions | 155 × 65 × 25 mm (L×W×H) |
| Probe Length | 170 mm |
| Weight | ~800 g |
| Temperature Compensation | Automatic |
| Data Output | Average reading function |
| Low-Battery Indicator | Yes |
| Probe Type | Insertion-type capacitive sensor |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-315AC |
| Measurement Range | 12–40% w/w |
| Accuracy | ±0.2% |
| Resolution | 0.1% |
| Temperature Compensation | Automatic |
| Display | LCD (Large-Digit) |
| Power Supply | 9 V DC (1 × 9V battery) |
| Dimensions | 154 × 105 × 43 mm |
| Weight | ~1.0 kg |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-3306 |
| Measurement Principle | Electrical Resistance Method |
| Moisture Range | 11–40% (w/w) |
| Accuracy | ±0.5% |
| Resolution | 0.1% |
| Measurement Time | ~3 s |
| Power Supply | 9 V alkaline battery (1 pc) |
| Instrument Dimensions | 85 × 170 × 36 mm (W × L × H) |
| Sensor Length | 170 mm |
| Net Weight | ~1.7 kg |
| Auto-Temperature Compensation | Yes |
| Auto-Calibration | Yes (pre-boot, algorithm-driven, mandatory for valid measurement) |
| Display | Large LCD with backlight |
| Auto-Hold & Auto-Power-Off | Yes |
| Battery Low Indicator | Yes |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-3306 |
| Measurement Principle | Electrical Resistance Method |
| Moisture Range | 11–40% w/w |
| Accuracy | ±0.5% |
| Resolution | 0.1% |
| Measurement Time | ~3 seconds |
| Power Supply | 9 V alkaline battery (1 pc) |
| Dimensions (Instrument) | 85 × 170 × 36 mm (W × L × H) |
| Sensor Length | 170 mm |
| Weight | ~1.7 kg |
| Display | Large LCD with backlight |
| Auto-Calibration | Yes (pre-programmed G-WON proprietary algorithm, performed at power-on) |
| Temperature Compensation | Automatic |
| Auto-Hold & Auto-Power-Off | Yes |
| Battery Low Indicator | Yes |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-3308 |
| Measurement Range (Hay) | 12.0–41.5% w/w |
| Resolution | 0.1% |
| Accuracy | ±0.5% |
| Measurement Time | ~3 s |
| Temperature Compensation | Automatic |
| Calibration | Fully Automated Self-Calibration Routine |
| Display | Large LCD |
| Power Supply | 9 V alkaline battery (1 pc) |
| Instrument Dimensions | 170 × 85 × 36 mm (L×W×H) |
| Sensor Length | 430 mm |
| Net Weight | ~2.0 kg |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-340 |
| Measurement Range | 13.0–40.0% w/w |
| Accuracy | ±0.5% |
| Resolution | 0.1% |
| Display | LCD |
| Power Supply | 9 V DC |
| Dimensions | 120 × 78 × 26 mm |
| Weight | ~750 g |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-503S |
| Measurement Principle | Electrical Resistance (Capacitance-Compensated) |
| Accuracy | ±0.5% w/w |
| Sample Types | Seeds & Fresh Horticultural Produce |
| Temperature Compensation | Automatic |
| Display | Large LCD |
| Power Supply | 4 × 1.5 V AA Batteries |
| Dimensions | 164 × 94 × 40 mm |
| Weight | ~1.2 kg |
| Compliance | Designed for ISO 712 and ASTM D4940-aligned field and lab moisture assessment |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | SIGMA-3030 |
| Measurement Principle | Electrical Resistance Method |
| Grain Types Supported | Paddy, Barley, Naked Barley, Brown Rice, Rice, Wheat |
| Moisture Range | 11.0–40.0% (varies by grain type) |
| Accuracy | ±0.5% (for moisture <20%) |
| Resolution | 0.1% |
| Throughput | 60 kernels/min |
| Measurement Modes | By Kernel Count (10–180 pcs) or Time Duration (20–60 sec) |
| Temperature Compensation | Automatic |
| Operating Temp | 5–50 °C |
| Interface | RS-232C |
| Power | AC 100–240 V, 50/60 Hz |
| Dimensions | 295 × 193 × 281 mm |
| Weight | ~8 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | W202-1 |
| Application | Multi-purpose WVTR analyzer for films, sheets, and packaging containers |
| Test Range | 0.001–100 g/(m²·24h) |
| Test Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional 5–55°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0%RH, 30–95%RH |
| Humidity Control Accuracy | ±1%RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 chambers (independent operation) |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–100 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 585 × 485 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz |
| Compliance | GB/T 21529-2008, YBB 00092003-2015, BS EN ISO 15106-3:2005, ASTM E398-2013, DIN 53122-2 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W403C |
| Test Range | 0.001–100 g/m²·24h |
| Test Accuracy | 0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0% RH (dry), 30–90% RH, and 100% RH |
| Humidity Control Accuracy | ±1% RH |
| Permeation Area | 50.24 cm² (reducible to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 independent test chambers |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Compliance Standards | GB/T 26253-2010, YBB 00092003-2015, BS EN ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SQ2 |
| Application | On-site quantitative determination of Chemical Oxygen Demand (COD) in industrial wastewater |
| Measurement Principle | Sealed reflux digestion coupled with colorimetric detection per GB 11914–1989 |
| Detection Time | 20 min per sample |
| Power Supply | 9 V alkaline battery (up to 40 h continuous operation) |
| Detection Limit | 30 mg/L |
| Range | 0–300 mg/L |
| Accuracy | ±5% |
| Kit Includes | 1 set of colorimetric apparatus, 1 set of sample pretreatment tools, and 1 reagent kit (50 determinations) |
| Brand | GFS |
|---|---|
| Origin | Germany |
| Model | NP330-F |
| Measurement Principle | Capacitive Dielectric Sensing (ASTM D1533 Traceable Calibration) |
| Measurement Range (Sensor) | 10–20,000 ppm H₂O in oil |
| Temperature Range (Sensor) | −20 °C to +70 °C |
| Pressure Rating (Sensor) | 0–300 bar |
| Sensor Thread | 1/2″ NPT |
| IP Rating (Sensor) | IP65 |
| Display Range (Desktop Unit) | 0–1999 ppm |
| Desktop Operating Temp. | 0–50 °C |
| Desktop Power | 230 V AC, 50–60 Hz |
| Desktop Enclosure | IP50 |
| Portable Unit Housing | Die-cast aluminum |
| Portable IP Rating | IP54 |
| Portable Power | Rechargeable Ni-Mn battery (4×AA equivalent) |
| Display | 2-line LCD, 16 characters/line |
| Data Storage Capacity | 12,000 records |
| Data Logging Interval | User-adjustable |
| Connector | Binder 723 |
| Interface | USB |
| Portable Operating Temp. | 0–40 °C |
| Dimensions (Desktop) | 150 × 65 × 210 mm (W×H×D) |
| Dimensions (Portable) | 100 × 220 × 42.4 mm (W×H×D) |
| Installation Depth | 50 mm |
| Brand | GFS |
|---|---|
| Origin | Germany |
| Model | NP330-G |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Aluminum Oxide Capacitive Sensor |
| Range | Standard −80 °C to +20 °C (optional −100 °C to +20 °C) |
| Accuracy | ±2 °C |
| Sample Gas Temperature | ≤ +60 °C |
| Operating Pressure | Up to 300 bar |
| Recommended Flow Rate | 1–5 L/min |
| Power Supply | 18–28 V DC, max. 70 mA |
| Ambient Temperature | −20 °C to +60 °C |
| Cable Length | 3 m |
| Ingress Protection | IP65 |
| Filter | 80 µm Sintered Stainless Steel |
| Sensor Thread | G1/2″, Insertion Depth: 50 mm |
| Calibration Interval | Annually Recommended |
| Dimensions | Total Length 176 mm |
| Weight | ~450 g |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Aqualysis 800PA |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DPD-Aqualysis800 |
| Price | Upon Request |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (hardness-dependent) |
| Accuracy | ±2% of selected reagent’s upper range |
| Repeatability | ±2% of selected reagent’s upper range |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 180 mm |
| Weight | 4 kg |
| Display | Color LCD with bilingual (English/Chinese) interface |
| Measurement Modes | Continuous or interval (1–360 min) |
| Sample Temperature Range | 5–40 °C |
| Ambient Operating Temperature | 10–40 °C |
| Sample Pressure Range | 0.2–5 bar (recommended: 1–2 bar) |
| Sample pH Range | 4–10 |
| Interference Limits | Fe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm |
| Output Options | 4 programmable relay outputs (max. 250 V, 4 A), 1 isolated 4–20 mA output (max. 750 Ω), 1 RS485 Modbus RTU port |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Flush Duration | Configurable (15–1800 s) |
| Reagent Kits | TH7000 to TH7100 (7 ranges, covering 0.177–625.8 ppm CaCO₃ equivalent) |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202CL |
| Price | Upon Request |
| Measurement Principle | Amperometric (Constant Voltage Detection) |
| Measurable Parameters | Free Chlorine, Chlorine Dioxide, Ozone |
| Sensor Type | Dual Platinum Electrode (Membrane-Free, Reagent-Free) |
| Flow Cell | BAF615 Flow-Through Cell |
| Pipe Compatibility | DN50–DN100 |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 Records |
| Output | Dual Isolated 4–20 mA (0.1% FS), RS485 Modbus RTU, Relay Alarms (2× Hi/Lo, 5 A) |
| Cleaning Control | Programmable Interval (0.1–1000 h) & Duration (1–1000 s) |
| Temp. Compensation | Automatic/Manual (NTC10K or PT1000), Range: −10 to +130 °C |
| Operating Temp. | −10 to +70.0 °C |
| Storage Temp. | −20 to +70.0 °C |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202I |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PM8202I |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) for Calcium |
| Range | 0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent) |
| Resolution | 0.01 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 ppm (≤10 ppm), ±0.1 ppm (10–100 ppm), ±1 ppm (>100 ppm) |
| Temperature Compensation | -10 to +130 °C (NTC30k or PT1000 sensor, manual/automatic) |
| Operating Temperature | -10 to +70.0 °C |
| Storage Temperature | -20 to +70.0 °C |
| Display | Backlit high-resolution dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Optional | 24 VDC |
| Output | Two isolated 4–20 mA analog outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for calcium concentration and temperature |
| Relay Output | One multifunctional relay (cleaning trigger, periodic alarm, fault alert) |
| Enclosure Rating | IP67-rated sealed housing |
| Electrode | Integrated BSENS740 calcium-selective composite electrode |
| Calibration | Two-point calibration with standard solutions (e.g., 100 ppm & 1000 ppm Ca²⁺) |
| Compliance | Designed per IEC 61000-6-2 (EMC immunity), IEC 61000-6-4 (EMC emission), and EN 61326-1 (laboratory & industrial measurement equipment) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PM8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent) |
| Resolution | 0.01 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 ppm (≤10 ppm), ±0.1 ppm (10–100 ppm), ±1 ppm (>100 ppm) |
| Temperature Compensation | –10 to +130 °C (NTC30k or PT1000 sensor input, manual/automatic) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for Ca²⁺ concentration or temperature) |
| Communication | RS485 Modbus RTU |
| Cleaning Cycle Control | Interval adjustable from 0.1 to 1000 h |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC), with user-defined hysteresis |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202I |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SC D8 200 |
| Price | Upon Request |
| Power Supply | 100–240 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" |
| Outlet Connection | 3/4" |
| Response Time | 1 s |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication | MODBUS (optional) |
| Alarm Outputs | High/Low relay |
| Enclosure Rating | IP65 |
| Dimensions | 11.0" × 6.00" |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SC D8200 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Measurement Range | –1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" NPT |
| Outlet Connection | 3/4" NPT |
| Response Time | ≤1 s |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, –10 to +10 V, 0–10 V |
| Communication | MODBUS RTU (RS-485, optional) |
| Alarm Outputs | Dual SPDT relays (high/low) |
| Enclosure Rating | IP65 |
| Dimensions | 279 mm × 152 mm (11.0" × 6.0") |
| Weight | 9 kg |
| Zero Calibration | Automatic |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD 8200 |
| Price | Upon Request |
| Power Supply | 100–240 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" |
| Outlet Connection | 3/4" |
| Response Time | 1 s |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication | Optional MODBUS RTU (RS-485) |
| Alarm Outputs | High/Low Relay |
| Enclosure Rating | IP65 |
| Dimensions | 279 × 152 mm (11.0" × 6.00") |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD8200 |
| Power Supply | 100–240 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" NPT |
| Outlet Connection | 3/4" NPT |
| Response Time | 1 s |
| Auto-zero Calibration | Yes |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication Protocol | MODBUS RTU (optional) |
| Alarm Outputs | High/Low relay contacts |
| Enclosure Rating | IP65 |
| Dimensions | 279 mm × 152 mm (11.0" × 6.0") |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD8200 |
| Price | Upon Request |
| Power Supply | 230 VAC, 50 Hz |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" |
| Outlet Connection | 3/4" |
| Response Time | 1 s |
| Zero Auto-Calibration | Yes |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication Protocol | MODBUS (optional) |
| Alarm Outputs | High/Low relay |
| Enclosure Rating | IP65 |
| Dimensions | 11.0" × 6.00" |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD8200 |
| Price | Upon Request |
| Power Supply | 100–240 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" |
| Outlet Connection | 3/4" |
| Response Time | 1 s |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication | MODBUS RTU (optional) |
| Alarm Outputs | High/Low relay contacts |
| Enclosure Rating | IP65 |
| Dimensions | 279 × 152 mm (11.0" × 6.0") |
| Weight | 9 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCGEST-121C |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 1×10⁻¹⁶ A to 2×10⁻⁴ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Accuracy | ±1% (≤1×10¹⁰ Ω), ±5–10% (>1×10¹⁰ Ω) |
| Display | Dual-line LCD showing voltage, resistance, and current simultaneously |
| Power Supply | 220 V AC / 50 Hz |
| Dimensions (L×W×H) | 300 mm × 300 mm × 150 mm |
| Weight | ~5 kg |
| Standard Electrode | 63 mm diameter, 2.5 kg |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TL23 Benchtop Turbidimeter |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TU5 Series Turbidimeter |
| Pricing | Upon Request |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI2002 |
| pH Range | -2.000 to 16.000 |
| pH Resolution | 0.001 / 0.01 |
| pH Accuracy | ±0.002 / ±0.01 |
| mV Range (pH-mV) | ±1000 mV |
| ORP Range | ±2000 mV |
| mV Resolution/Accuracy | 0.1 mV / ±0.2 mV (±999.9 mV), ±1 mV (±2000 mV) |
| Temperature Range | -20.0 to 120.0 °C |
| Temp Resolution/Accuracy | 0.1 °C / ±0.5 °C |
| Calibration | Up to 5-point auto-recognizing pH, single-point ORP |
| Data Storage | 1000 auto, 200 interval, 600 manual |
| Interface | micro-USB + USB-A |
| Power | Rechargeable Li-ion battery with 5 V adapter |
| Dimensions | 202 × 140 × 12 mm |
| Weight | 250 g |