Moisture Analyzer
Filter
Showing 121–150 of 165 results
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM120 |
| Maximum Capacity | 124 g |
| Minimum Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Drying Time Range | 0.1–99.9 min |
| Termination Modes | Automatic, Semi-Automatic (Δdigit/sec or Δ%/sec), Fixed-Time |
| Data Output Interval | 0.1–10.0 min |
| Password Protection | Yes |
| Statistical Functions | Count, Mean, Max, Min, Standard Error |
| Interface | RS232 |
| Memory | 50 Method Programs, 999 Test Records |
| Preheating | 30–100 °C |
| Multi-Stage Heating | 3 programmable segments (temp + time per stage) |
| Boost Mode | 140% target temp for first 3 min |
| Firmware Update | Remote via network |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM60 |
| Maximum Capacity | 62 g |
| Minimum Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost Function (140% target temp for first 3 min) |
| Termination Modes | Automatic, Semi-Automatic (user-defined mass change per second), Timed (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Preset Methods | 5 |
| Security | Password Protection, Physical Lock Slot |
| Interface | RS232 |
| Firmware Update | Remote download via network |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRDZT-380 |
| Application | Wood Moisture & Insulation Resistance Testing |
| Resistance Range | 10² Ω to 10¹⁶ Ω (extendable to 10²⁰ Ω via current extrapolation) |
| Resistivity Range | up to 10²² Ω·cm |
| Voltage Accuracy | ±0.5% ±1 V |
| Measurement Speed | Fast mode — 5 readings/sec |
| Display | 4.3″ high-resolution TFT LCD |
| Interface | Banana jacks, BNC connectors |
| Compliance Reference | GB/T 10580–2003, IEC 60260, ASTM D257, ISO 3915 |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | LMA200PM (Discontinued, succeeded by MA160) |
| Measurement Principle | Microwave-assisted thermogravimetric loss-on-drying |
| Max Sample Capacity | 70 g |
| Readability | 0.1 mg |
| Moisture Range | 8–100% w/w |
| Heating Source | 1000 W adjustable microwave generator (2–100% power, 1% increments) |
| Endpoint Detection | Dual-sensor mode (mass loss + moisture vapor monitoring), timer mode, or user-defined mass/time thresholds |
| Programmable Methods | 320 stored methods |
| Compliance | GLP-compliant reporting, 21 CFR Part 11-ready software interface |
| Dimensions (W×D×H) | 510 × 535 × 304 mm |
| Power Supply | 230 V AC, 50 Hz, max. 1200 VA |
| Interfaces | RS-232, Ethernet |
| Display Language | English, French, German, Italian, Spanish |
| Printer | Built-in thermal printer (non-fading paper) |
| Sample Tray | 90 mm diameter glass fiber pad |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MA100 |
| Heating Method | Infrared |
| Key Features | 0.1 mg weighing precision, EC-type approval with CE conformity certificate, integrated motor-driven heating unit and sample chamber, SPRM auto-optimization function, modular heating source options (infrared ceramic, halogen, quartz), Plug&Dry™ cleaning system, optional built-in thermal printer |
| Compliance | CE-marked, compliant with ISO 8573-1 (for moisture in compressed air applications), supports GLP/GMP documentation requirements via audit trail-capable software |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA100 |
| Heating Method | Infrared (with optional halogen and quartz heating elements) |
| Readability | 0.1 mg |
| Certification | EC Type Approval for heating unit and weighing system |
| Drive Mechanism | Motor-driven integrated heating unit |
| Optional | Built-in thermal printer |
| Cleaning Design | Plug & Dry™ removable heating module |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA160 |
| Heating Method | Infrared |
| Application Scope | Laboratory & QC Environment |
| Method Storage Capacity | 100 methods |
| Cleaning Design | Removable heated module and sample chamber base plate (dishwasher-safe) |
| Status Indication | Visual status LED array |
| Method Development Time | ≤45 minutes (3-step guided workflow) |
| Performance Verification | Integrated test routine with ReproEasy reference pads |
| Compliance Context | Designed to support GLP/GMP workflows, audit-ready method documentation, and traceable instrument qualification |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA160-1CN |
| Heating Method | Infrared |
| Application Category | Laboratory & QC Moisture Analysis |
| Compliance Context | Designed for GLP/GMP environments, supports 21 CFR Part 11–compliant data integrity workflows (when integrated with optional software) |
| Method Storage Capacity | Up to 100 user-defined methods |
| Method Development Time | ≤45 minutes per new method (3-step guided workflow) |
| Cleaning Design | Removable heating module and sample chamber base plate, dishwasher-safe |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MA35M |
| Heating Method | Infrared (Dual Metal-Tube IR Emitters) |
| Max Capacity | 35 g |
| Readability | 1 mg |
| Temperature Range | 40–160 °C (1 °C increments) |
| Heating Technology | IRPlug&Dry® Reflective Infrared Heating |
| Endpoint Detection | Automatic or Timed (0.1–99 min) |
| Compliance | FDA/HACCP-compliant versions available (V2 suffix) |
| Dimensions (W×D×H) | 224 × 366 × 191 mm |
| Weight | ~5.8 kg |
| Interface | RS-232C (unidirectional) |
| Sample Pan Diameter | 90 mm |
| Display | Graphical LCD with intuitive icon-based navigation |
| Reporting | GLP-compliant print templates (via optional thermal printer) |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MA37 |
| Heating Method | Infrared (Metal Halide Heater) |
| Weighing Capacity | 70 g |
| Weighing Accuracy | ±0.2% for samples >1 g |
| Heating Source | Metal Halide Infrared Heater |
| Power Consumption | 640 VA |
| Line Voltage | 115 V / 230 V |
| Line Frequency | 50/60 Hz |
| Sample Chamber Access | Removable hood with wide-opening angle and SoftClose mechanism |
| Recommended Moisture Range | 0.01–100.00% (w/w) |
| Application Scope | Standard & thermosensitive materials |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA37 |
| Heating Method | Infrared |
| Weighing Capacity | 70 g |
| Heating Source | Metal Heater |
| Power Consumption | 640 VA |
| Line Voltage | 115 V / 230 V |
| Line Frequency | 50 / 60 Hz |
| Hood | Removable with Wide Opening Angle & SoftClose Mechanism |
| Weighing Accuracy | > 1 g: ±0.2 % |
| > 5 g | ±0.05 % |
| Recommended Moisture Range | 1–100 % |
| Brand | Sartorius |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MA37-1CN |
| Price | USD 2,950 (approx.) |
| Heating Method | Infrared Metal Heater |
| Maximum Sample Capacity | 70 g |
| Readability | 1 mg / 0.01% |
| Voltage | 115 V / 230 V AC |
| Moisture Range | 0.01–99.99% |
| Programmable Methods | Yes |
| Compliance | Designed for GLP/GMP environments with audit-ready operation log |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | QFS601 |
| Measurement Range | -80 to +20 °C dew point (≈ 0.5–23,632 µL/L H₂O) |
| Accuracy | ≤ ±1 °C |
| Response Time | <30 s (63%), <60 s (90%) for rise at DP < -40 °C |
| Output Signals | 4–20 mA, RS232 or USB (user-specified) |
| Power Supply | AC 220 ± 22 V, 50–60 Hz / Internal rechargeable battery (DC) |
| Operating Conditions | Gas Temp < +60 °C, Pressure < 2 MPa, Recommended Flow Rate: 200 mL/min |
| Dimensions | 260 × 170 × 300 mm (W × H × D) |
| Brand | scchengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | USI-1AB |
| Product Type | Online Dew Point Moisture Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–40 °C (ambient) |
| Supply Gas Pressure | <100 kPa |
| Accuracy | ±5% of reading |
| Repeatability | <0.08 µL/L at sample moisture ≤260 µL/L |
| Range | 0–1000 µL/L (ppmv) |
| Response Time (t₆₃) | ≤3 min |
| Output Signals | 0–10 mV and 4–20 mA |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Sample Flow Rate | 100 mL/min (measurement), 1 L/min (bypass) |
| Dimensions | 380 × 300 × 170 mm |
| Weight | 6.5 kg |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Burette Capacity | 20 mL (DURAN® borosilicate glass, Class 3, UV-protected jacket) |
| Valve System | PTFE/ECTFE three-way safety valve |
| Tubing | UV-resistant FEP tubing with PTFE check valves |
| Dispensing Accuracy | ±0.03–0.07% (burette), ±0.1–0.2% (system) |
| Display | Backlit LCD (69 × 39 mm, 64 × 128 characters), auto-adjusting brightness |
| Electrode | Dual platinum electrode, polarizing voltage adjustable from 5–200 mV (default 100 mV) |
| Current Measurement Range | 0–99.9 µA, resolution 0.1 µA |
| Interfaces | Dual RS-232 ports (PC/printer + balance/expansion) |
| Calibration Modes | Pure water, certified standard, sodium tartrate dihydrate (with solvent/gas blank correction) |
| Reporting | On-screen results + printable reports (Basic, Standard, GLP-compliant) |
| Calculation Units | ppm, mg, mg/L, mg/pc |
| Stirring Speed | 50–1000 rpm |
| Power Supply | AC 230 V, 50/60 Hz, 30 VA |
| Dimensions (W × H × D) | 310 × 265 × 205 mm (including titration unit) |
| Weight | 3.2 kg |
| Compliance | DIN 12650 Part 5, EN ISO 8655-3 |
| Qualification Support | DQ/IQ/OQ/PQ documentation available on request |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SADP-D |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Sensor |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±3 °C to ±4 °C |
| Repeatability | ±0.5 °C |
| Dew Point Range | -100 °C to +20 °C |
| Display | Backlit LCD (°C/°F selectable) |
| Power Supply | Standard C-cell batteries |
| Battery Life | >150 hours continuous operation |
| Certification | ATEX II 2G Ex ia IIC T4 Ga, IECEx EXA 22.0001X |
| Calibration | NIST-traceable certificate included |
| Accessories | 2 m PTFE sampling hose, leather carry case with shoulder strap, desiccant-dried test chamber, user manual |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SDA-P |
| Type | Online Dew Point Meter |
| Principle | Chilled Mirror (Electrochemical Sensor Variant) |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±3 °C |
| Repeatability | ±3 °C |
| Measuring Range | -100 °C to 0 °C |
| Display | 3½-digit backlit LCD |
| Output | 4–20 mA analog signal, dual relay alarms (240 V AC @ 3 A) |
| Power Supply | 220 V AC, 50 Hz |
| Installation | Panel mount (cutout: 135 mm × 66 mm × 175 mm depth) |
| Sample Pressure | 1–30 psi (up to 200 bar sensor-rated) |
| Sample Flow Rate | 1–5 L/min (recommended: 1 L/min) |
| Gas Connection | 1/4" or 1/8" compression fittings |
| Intrinsic Safety | Sensor certified intrinsically safe |
| Calibration | Automatic 1-minute ambient air zero calibration |
| Compliance | ISO 9002 quality management system |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MOC-120H |
| Price Range | USD 1,400 – 4,200 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Designation | ASTM-compliant GC-BID Configuration |
| Pricing | Available upon Request |
| Brand | Shimadzu |
|---|---|
| Model | Unibloc MOC63U |
| Heating Source | Halogen Lamp |
| Temperature Range | 50–200 °C |
| Minimum Sample Weight | 0.001 g |
| Display | Backlit LCD |
| Interfaces | RS-232C, USB, DATA I/O |
| Data Export | Direct to Microsoft Excel via Windows Pass-Through Window |
| Measurement Modes | Auto-Stop, Time-Stop, Standard/Fast/Slow/Step Drying |
| Dimensions (L) | 202 mm |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPS Series |
| Pricing | Available Upon Request |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | DHS Series |
| Heating Method | Infrared |
| Max Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (DHS-16A), 50–200 °C (DHS-20A) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min steps) |
| Termination Modes | Auto (weight stability), Timed, Manual |
| Built-in Methods | 50 user-programmable protocols |
| Output Parameters | Initial mass (g), Residual mass (g), Moisture content (% w/w), Dry matter (%), Moisture loss (%), Regain (%), Wet basis moisture (%), Heating mode, Set temperature, Duration |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation templates available |
| Power Supply | 220 VAC (±15% / −10%), 50 Hz |
| Power Consumption | 400 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | LHS Series |
| Heating Method | Halogen Lamp |
| Maximum Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (LHS-16 models), 50–200 °C (LHS-20 models) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min increments) |
| Termination Modes | Automatic (weight change-based), Timed, Manual |
| Built-in Methods | 50 pre-programmed |
| Result Outputs | Initial mass (g), Residual mass (g), Moisture content (%), Dry matter (%), Moisture loss (%), Rehydration ratio, Wet basis moisture (%) |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation support |
| Power Supply | 220 VAC (−15% to +10%), 50 Hz |
| Power Consumption | 420 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Net Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | MaxTira20Q |
| Pricing | Upon Request |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | MaxTitra20V |
| Pricing | Upon Request |
| Titration Method | Volumetric Karl Fischer |
| Endpoint Detection | AC Polarization Potential Difference |
| Measurement Range | 0.1 mg – 500 mg H₂O (equivalent to 10 ppm – 100% w/w) |
| Minimum Dispensing Volume | 0.005 mL |
| Data Storage | 20 built-in methods & results |
| Display | 16-character × 2-line LCD with backlight |
| Interfaces | RS-232 for balance, printer, and PC |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 W |
| Dimensions | 310 W × 270 D × 310 H mm |
| Weight | ~6 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YLS-B Series |
| Price Range | USD 700 – 1,400 (FOB) |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g (YLS-B Plus) / 20 g (YLS-B Standard) |
| Readability | 1 mg (60 g model) / 2 mg (20 g model) |
| Moisture Resolution | 0.02–0.1% |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Time | 0–99 min (1 min steps) |
| Display | Backlit dot-matrix LCD with dual blue/white background |
| Data Storage | 50 sample profiles |
| Interface | RS232C |
| Calibration | External weight calibration (20 g for YLS-B |
| Compliance | Supports IQ/OQ/PQ validation |
| Power Supply | 220 VAC (±15%/+10%), 50 Hz |
| Power Consumption | 300 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Recommended Ambient | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 458 × 278 × 246 mm |
| Net Weight | 5.5 kg |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1100 |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature Range | 0–40 °C |
| Measurement Time | < 1 s |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Display | 3.5-inch backlit graphical LCD |
| Data Storage | EEPROM, up to 250 measurements |
| Memory Slots | 25 product-specific calibration profiles |
| Power Supply | NiMH rechargeable battery |
| Battery Life | ~5 h (median usage, fully charged) |
| Protection Rating | IP20 |
| Interface | USB |
| Software | TEWS Moisture View Lite © |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1150 |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Measurement Time | <1 s |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Sample Temperature Range | 5–60 °C (with optional Pt100 or IR temperature sensor and auto thermal stabilization compensation) |
| Ambient Temperature Range | 0–40 °C |
| Enclosure Rating | IP20 |
| Display | Backlit LCD graphic display (320 × 240 pixels), 5.7-inch diagonal |
| Internal Memory | EEPROM storage for up to 25 product profiles and 250 measurement records |
| Data Interface | USB (PC connectivity) |
| Analog Output | 0(4)–20 mA with current isolation |
| Software Support | TEWS Moisture View Lite © |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 3012 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Temperature | 0–40 °C |
| Analog Input | Product Temperature |
| Analog Output | Measured Values |
| Digital I/O | Control & Status Signals |
| Communication Interfaces | RS-232/RS-485 Serial, Ethernet (10/100BASE-T), CAN 2.0A/B, LAN |
| Max Sampling Rate | 40,000 readings/s |
| Application Scope | In-line moisture & density measurement of fast-moving discrete or continuous materials (e.g., cigarettes, yarns, tablets, capsules, filter rods) |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4260 / MW 4270 / MW 4200 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 160 VA (MW 4260), 200 VA (MW 4270) |
| Operating Temperature | 0–45 °C |
| Display | 10.4" LED color touchscreen (MW 4270), 5" LCD (MW 4260), single-line LED (MW 4200) |
| Data Interfaces | 1× Ethernet, 1× analog input (0/4–20 mA), 3× analog outputs (0/4–20 mA), 8× passive digital outputs, 8× digital inputs |
| Measurement Rate | up to 3,500 readings per second |
| Internal Data Storage | 60,000 measurements |
| Enclosure Rating | IP55 (industrial duty), ATEX-certified variants available for gas/dust hazardous areas |
| Sensor-to-Display Distance | up to 8 m (MW 4200 optimized for remote mounting) |