| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROS 1 |
| Pricing | Available Upon Request |
| Measurement Principle | Standard Gravimetric Loss-on-Drying (LOD) with Real-Time Mass Monitoring |
| Heating Method | Resistive Coil Conduction (Not Halogen or Microwave) |
| Sample Capacity | 9 Independent Positions |
| Temperature Range | 50–150 °C (1 °C Increments) |
| Balance Readability | 0.0001 g |
| Max Load per Pan | 50 g |
| Sample Weight Range | 1–15 g |
| Moisture Range | 0.1–100 % w/w |
| Accuracy | ±0.15 % |
| Repeatability (4 g) | ±0.05 % |
| Repeatability (10 g) | ±0.01 % |
| Compliance | AOAC 937.02, ASTM D4442, ISO 4463, USP <921>, FDA 21 CFR Part 11 Ready (with optional software audit trail) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQV-2200 |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SDW-300S / SDW-600W / SDW-120F |
| Price | Upon Request |
| Weighing Accuracy | 0.01 g / 0.005 g / 0.005 g / 0.001 g |
| Max Capacity | 300 g / 300 g / 600 g / 120 g |
| Density Resolution | 0.001 g/cm³ / 0.001 g/cm³ / 0.001 g/cm³ / 0.0001 g/cm³ |
| Measurement Principle | Archimedean buoyancy method (hydrostatic weighing) |
| Sample Types | Solids, granules, foams, floating materials, porous bodies, thin films, and water-absorbing specimens |
| Measurement Time | ~10 seconds |
| Interface | RS-232 serial output |
| Compliance Standards | ASTM D792, ASTM D297, ISO 1183, ISO 2781, GB/T 1033, GB/T 2951, GB/T 3850, GB/T 533, JIS K6268, HG4-1468 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SE2 |
| Application | Field and Laboratory Quantitative Determination of Chlorine Dioxide in Water Samples |
| Light Source | 520 nm LED |
| Optical Stability | ±0.005 Abs/20 min |
| Detection Limit | 0.02 mg/L |
| Measurement Range | 0.00–3.00 mg/L |
| Measurement Time | 1 minute |
| Accuracy | ±5% |
| Power Supply | DC 9 V battery |
| Auto Power-Off | After 30 minutes idle |
| Battery Status Indicator | Integrated low-battery diagnostic circuit |
| Compliance | GB/T 5750.11–2006 (Standard Method for Examination of Disinfectants in Drinking Water) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SN |
| Application | Field-deployable photometric analyzer for residual and total chlorine in water |
| Detection Method | DPD colorimetric method per GB/T 5750.11–2006 |
| Detection Time | ≤3 min |
| Detection Range | 0.00–9.99 mg/L Cl₂ |
| LOD | 0.10 mg/L |
| Accuracy | ±5% of reading |
| Power Supply | 9 V alkaline battery (≥40 h continuous operation) |
| Reagent Format | Single-use, pre-packaged DPD reagent kits (50 tests per kit) |
| Included Accessories | Complete set of calibrated colorimetric cuvettes and reagents (50 tests) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SN2 |
| Application | Quantitative residual chlorine analysis in water samples |
| Detection Method | DPD colorimetric method per GB/T 5750.11–2006 |
| Detection Time | ≤3 minutes |
| Detection Range | 0.00–5.00 mg/L |
| Lower Detection Limit | 0.05 mg/L |
| Accuracy | ±5% of reading |
| Power Supply | 9 V alkaline battery (operating life: ≥40 hours) |
| Reagent Format | Single-use, pre-packaged DPD reagent kits (50 tests per kit) |
| Accessories Included | Complete set of calibrated colorimetric cuvettes and reagents (50 tests) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SV |
| Application | Quantitative sulfide analysis in drinking water, surface water, domestic wastewater, and treated effluent |
| Detection Method | Colorimetric (methylene blue method per GB/T 5750.5–2006) |
| Detection Time | ≤10 min |
| Detection Limit | 0.02 mg/L |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% |
| Power Supply | 9 V alkaline battery (operational life ≥40 h) |
| Reagent Format | Single-use, pre-packaged assay kits (50 tests per kit) |
| Included Accessories | Complete set of colorimetric glassware and reagents (50 assays) |
| Brand | Beifen Sanpu |
|---|---|
| Model | KS-1 |
| Standard Compliance | GB/T 3536, ASTM D92 |
| Flash Point Range | Ambient to 400 °C |
| Repeatability | ±2 °C (≤150 °C), ±4 °C (>150 °C) |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 400 W |
| Temperature Control | Solid-State Voltage Regulator (Continuous Ramp) |
| Dimensions (W×D×H) | 285 × 185 × 350 mm |
| Net Weight | 7 kg |
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KS100 |
| Compliance | GB/T 267–1988, GB/T 3536–2008, GB/T 1671–2008, ASTM D92 |
| Measurement Range | Ambient to 400 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤3 °C |
| Temperature Resolution | 0.1 °C |
| Sensor | Imported Class A PT100 Platinum Resistance Thermometer |
| Ignition Detection | Ionization Ring Sensor |
| Power Supply | AC 220 V ±20%, 50 Hz ±10% |
| Rated Power | 400 W |
| Dimensions | 440 × 280 × 290 mm |
| Weight | 18 kg |
| Operating Environment | 0–40 °C, ≤85% RH |
| Control Interface | Capacitive Touchscreen with Screen Protection |
| Data Storage | 255 Test Records with Timestamps |
| Heating Control | Adaptive PID Algorithm per Standard Protocols |
| Atmospheric Compensation | Integrated Barometric Sensor with Auto-Calibration |
| Ignition Options | Selectable Electronic Spark or Gas Flame Ignition |
| Multi-Furnace Capability | Single Host Controls Multiple Independent Test Furnaces |
| Automation Level | Full Cycle Automation (Heating, Lid Opening, Ignition, Flash Detection, Alarm, Cooling, Reporting) |
| Built-in Thermal Printer | High-Speed, Dot-Matrix, Offline Printing Support |
| Self-Diagnostic System | Real-Time Sensor Health Monitoring and Over-Temperature Safeguard |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SF101 |
| Application | Multi-purpose coulometric moisture determination for liquids, gases, and solids |
| Measurement Principle | Coulometric Karl Fischer titration (电量法) |
| Display | 7-inch color TFT LCD touchscreen with Chinese UI |
| Electrolysis Current Range | 0–400 mA (auto-controlled) |
| Measurement Range | 0.1 µg – 200 mg H₂O (equivalent to 0.1 ppm – 100% w/w) |
| Resolution | 0.1 µg H₂O (0.1 ppm) |
| Accuracy | ≤ ±0.2% for samples ≥1 mg H₂O |
| Data Storage | 256 test records |
| Sample Introduction Modes | Volumetric injection, gravimetric weighing, and dilution-based injection |
| Automatic Unit Conversion | µg H₂O, ppm, % w/w, mg H₂O/L, and mean values |
| Printer | High-speed thermal micro-printer |
| Power Consumption | 60 W |
| Operating Temperature | 5–45 °C |
| Relative Humidity Limit | ≤80% RH |
| Dimensions (W×D×H) | 350 × 230 × 180 mm |
| Weight | 8 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZFMD102 |
| Pricing | Available Upon Request |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Sample Positions | 2 |
| Power Rating | 1000 W |
| Supply Voltage | AC 220 V ±20%, 50 Hz ±10% |
| Operating Ambient | 0–40 °C, ≤85% RH |
| Dimensions (W×D×H) | 440 × 350 × 550 mm |
| Display | 320 × 240 dot-matrix LCD with capacitive touch keys |
| Interface | RS-232 serial port |
| Thermal Printer | Integrated high-speed thermal printer with offline printing capability |
| Compliance Standard | GB/T 1884–1992 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZFSZ100 |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | TOP RAY 160 |
| Pricing | Available Upon Request |
| Maximum Sample Capacity | 160 g |
| Readability | 0.001 g |
| Repeatability | ±0.0005 g |
| Moisture Range | 0.01–100.00% (w/w) |
| Temperature Range | 50–160 °C (adjustable in 1 °C increments) |
| Heating Source | Dual Heraeus quartz halogen lamps |
| Heating Chamber Material | Full stainless steel (AISI 304) |
| Power Supply | 230 V ±15%, 50/60 Hz |
| Drying Accuracy | ±1% (relative to reference method, e.g., Karl Fischer or loss-on-drying per ASTM E1868) |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 ppm |
| Moisture Content Range | 0.00001% (0.1 ppm) to 100% |
| Measurement Accuracy | ±0.1 ppm |
| Minimum Dispensing Volume | 0.5 µL |
| Titration Control Precision | ±0.1 mV |
| Repeatability | ≤0.0002% RSD |
| Linearity Correlation Coefficient | ≥0.9999 |
| Power Consumption | <50 W |
| Operating Voltage | AC 220 V ±10%, 50 Hz |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤85% RH (non-condensing) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HBD4-MS1204Dip |
| Price Range | USD 1,400–4,200 |
| Measurement Principle | High-Frequency Capacitance Sensing (1–10 MHz) |
| Range | 0.01–100.0% w/w moisture |
| Repeatability | ±0.5% FS |
| Accuracy | ±2.0% FS |
| Response Time | <100 ms (electrical), <15 s (full system stabilization at 25 °C) |
| Sample Temp. | −40 to +85 °C |
| Max. Process Pressure | <0.3 MPa |
| Ambient Temp. | −10 to +60 °C |
| Power Supply | Rechargeable 9 V NiCd battery (HBD5), 4 h continuous operation, 1 week standby |
| Total Power Consumption | <150 mW |
| Explosion Protection | Ex d ia IIC T5 (IEC 60079-0, -1, -11) |
| Output Interface | RS232 & RS485 (STIMcom default |
| Enclosure Rating | NEMA 2 |
| Sensor Dimensions | Ø24 × 240 mm (customizable) |
| Probe Mounting | 1″ NPT or ZG1″ thread |
| Instrument Dimensions | 98 × 32 × 185 mm |
| Weight | <0.7 kg |
| Long-Term Stability | ±1% over 5 years |
| Compliance | ASTM D6304, ISO 8533, IEC 61000-6-2/6-4 (EMC), RoHS |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Bigdipper Instruments Co., Ltd. |
| Model | T-BD5 MS1204p |
| Measurement Principle | Microwave attenuation (MS1204 sensor technology) |
| Operating Temperature | 100–350 °C |
| Pressure Rating | 1.6–4.0 MPa |
| Water Content Range | 0.02–101% w/w |
| Resolution | 0.02–0.1% |
| Repeatability | ±0.05% to ±1.0% FS |
| Output | 4–20 mA analog, RS232/RS485, Modbus RTU, IEEE 1451.2 STIM |
| Enclosure Rating | NEMA 7/8/9 |
| Intrinsic Safety | Ex ia IICT6 |
| Flameproof Protection | Ex d ia IIC T5 |
| Wetted Materials | 1Cr18Ni9Ti stainless steel, polyimide |
| Installation Options | Threaded (ZG1", NPT), flanged, clamp-type, bypass |
| Flow Orientation | Counter-flow (frontal insertion) |
| Sensor Geometry | Insertion-type probe with optimized electromagnetic field distribution |
| Compliance | ASTM D4006, ISO 9001, GB/T 11141-2014, ATEX Directive 2014/34/EU (via third-party certification), IEC 60079-0/-11/-14, FDA 21 CFR Part 11 (data integrity support via audit trail in BD5xCMD firmware) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | T-BD5-EMC1204 |
| Operating Temperature | -10°C to 40°C |
| Storage Temperature | -41°C to 71°C |
| Supply Voltage | DC 24 V |
| Output Signal | 4–20 mA |
| Response Time | <10 ms |
| Thread Interface | G1" (external) |
| Accuracy | ±0.5%–1.5% FS |
| IP Rating | IP65 |
| Intrinsically Safe Design | Ex ia IIC T6 |
| Hazardous Area Classification | Class I, Groups A/B/C/D |
| Contact Materials | 304 Stainless Steel + PTFE |
| Communication | RS232 / RS485 / IEEE 1451.2 STIM / Modbus RTU |
| Transmitter Options | BD5xCD (with local display) or BD5xC (no display) |
| Typical Measurands | Water-in-oil, oil-in-water, polymer solutions, emulsions, slurries, pulp suspensions, solvents, pharmaceutical intermediates |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | T-BD5IMD+MS1204pcR0.01-10T120 P1.6 |
| Operating Pressure | 1.6 MPa (standard) |
| Temperature Range | -40°C to +100°C |
| Moisture Range | 0–100.0% w/w |
| Accuracy | ≤0.1% FS |
| Repeatability | ±0.1% FS |
| Resolution | 0.01% |
| Insertion Depth | 240 mm (standard, customizable) |
| Enclosure Rating | IP56 / NEMA 4X |
| Explosion Protection | Ex ia IIC T4 Ga |
| Wetted Materials | 1Cr18Ni9Ti (AISI 321 stainless steel) |
| Power Supply | 9–24 V DC @ 100 mA |
| Output Signal | 4–20 mA (configurable, full-scale) |
| Total Length | <700 mm |
| Weight | 2.5–5 kg |
| Brand | Brabender |
|---|---|
| Origin | Germany |
| Model | MT-C |
| Measurement Principle | Convection Oven Drying (Gravimetric) |
| Compliance | ICC Standard 110/1, ISO 712, EC Regulation No. 2182/2005 (Tobacco), German Legal Metrology Approval for Tobacco Testing |
| Sample Capacity | Up to 10 samples simultaneously |
| Moisture Range | 0.1–99.9% w/w |
| Resolution | 0.1% moisture |
| Maximum Drying Temperature | 200 °C |
| Automation | Fully automated drying, cooling-free re-weighing, and data logging |
| Brand | Brookfield |
|---|---|
| Model | BS100 |
| Measurement Range | Ambient to 350 °C |
| Accuracy | ±1 °C (≤104 °C), ±2 °C (>104 °C) |
| Repeatability | ±2 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Sensor | Imported Class A PT100 Platinum Resistance Thermometer |
| Ignition Detection | Thermocouple-based Flash Sensor |
| Power Supply | AC 220 V ±20%, 50 Hz ±10% |
| Power Consumption | 400 W |
| Dimensions | 440 × 280 × 290 mm |
| Weight | 18 kg |
| Operating Environment | 0–40 °C, ≤90% RH |
| Compliance | GB/T 261–2008, ISO 2719, ASTM D93 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Computrac MAX-4000XL |
| Price Range | USD $12,500 – $37,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Computrac MAX-5000XL |
| Price Range | USD $13,500 – $40,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Computrac Vapor Pro XL |
| Application | Multi-purpose moisture analyzer |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 ppm |
| Repeatability | ≤10% C.V. (for samples >0.1% moisture), ≤15% C.V. (for samples <0.1% moisture) |
| Temperature Range | 25–300°C |
| Sample Weight | 0.01–8 g |
| Display Units | %, ppm, µg |
| Storage Capacity | 250 methods, 1000 results, 100 moisture curves |
| End Criteria | Predictive, Rate, Time, Time-Rate |
| Calibration | NIST-traceable capillary |
| Power | 100–120 V~ / 220–240 V~, 50/60 Hz |
| Dimensions | 17.2 × 47 × 27.9 cm |
| Weight | 8.0 kg |
| Certifications | UL, CE |
| Compliance Options | 21 CFR Part 11 (optional), ASTM D7191-10, ASTM D7546-15 |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | SMART Q |
| Heating Method | Infrared |
| Measurement Range | 0.01–15% moisture content |
| Resolution | 0.001% |
| Balance Precision | 0.0001 g (4-digit analytical balance with 3-digit moisture display) |
| Sample Types | Solids, powders, slurries, non-polar solvents, low-moisture polymers, coatings, pharmaceuticals |
| Compliance | Designed for GLP/GMP environments |
| Brand | PROCESS INSTRUMENTS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Chanscope II |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature Range | –20 °C to +40 °C |
| Accuracy | ±0.2 °C |
| Repeatability | ±0.1 °C |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CAT 7500 |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µA |
| Water Content Range | 1 ppm to 100% w/w |
| Accuracy | ≤0.05% |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Burette Control Precision | 0.15% |
| Display | 3.5″ 1/4 VGA TFT color screen (320 × 240 pixels) |
| Burette Options | 5 mL / 10 mL / 20 mL borosilicate glass (DURAN® 3.3), PTFE piston & valve |
| Electrode Interface | Dual platinum electrode (2 × 4 mm), polarization voltage adjustable 40–220 mV |
| Communication | 2 × USB-A, 1 × USB-B, 2 × RS232 |
| Dimensions (W×H×D) | 153 × 45 × 296 mm |
| Weight | 2.3 kg (host), 3.5 kg (complete system, excluding magnetic stirrer TM235KF) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Eurotherm |
| Sample Weight Range | 0.14–200 g |
| Moisture Accuracy | ±0.01% |
| Moisture Resolution | 0.01% |
| Heating Temperature Range | 50–180 °C |
| Heating Power | 350 W |
| Timer Range | 1–999 min |
| Balance Resolution | 0.001 g |
| Repeatability | ±0.001 g |
| Linearity | ±0.002 g |
| Pan Diameter | 120 mm |
| Dimensions (W×D×H) | 210 × 355 × 300 mm |
| Weight | 9 kg |
| Operating Ambient Temperature | 10–40 °C |
| Calibration | External |
| Interface | RS232 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | EUT |
| Heating Method | Infrared |
| Weighing Range | 200 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Linearity | ±0.002 g |
| Pan Diameter | Φ120 mm |
| Dimensions (W×D×H) | 210×355×300 mm |
| Weight | 9 kg |
| Minimum Sample Mass | 140 mg |
| Maximum Sample Mass | 200 g |
| Moisture Accuracy | ±0.01% |
| Moisture Resolution | 0.01% |
| Timer Range | 1–999 min |
| Heating Temperature Range | 50–180 °C |
| Max Heating Power | 350 W |
| Operating Ambient Temperature | 10–40 °C |
| Calibration | External |
| Interface | RS232 |
| Brand | Chengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Lab-Scale Dew Point Analyzer |
| Model | USI-3 |
| Pricing | Available Upon Request |
| Instrument Principle | Electrolytic (Phosphorus Pentoxide Sensor) |
| Operating Temperature | 5–35 °C |
| Accuracy | ±3% of total water mass |
| Repeatability | ≤1% RSD |
| Measurement Range | 0.0000–99.999 mg H₂O |
| Power Supply | AC 220 ± 22 V, 50–60 Hz or DC 10–45 V (for integrated dryer unit) |
| Carrier Gas | Ultra-Dry Nitrogen (<10 ppmv H₂O), Flow Rate: 70 ± 20 mL/min |