Moisture Analyzer
Filter
Showing 151–165 of 165 results
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4300 / MW 4310 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 60 VA |
| Operating Temperature | 0–45 °C |
| Data Interfaces | 2× RS-232 (COM + Service), 1× Ethernet, 3× USB, 1× Analog Input (0/4–20 mA for optional IR sensor), 1× Pt100 temperature sensor input, PS/2 mouse & keyboard + VGA display support |
| Measurement Time | Millisecond-scale |
| Internal Data Storage | 6,000 measurements |
| External Server Storage | Unlimited |
| Display | MW 4300 — integrated 10.4" (26.4 cm) LCD color touchscreen |
| Sample Volume Range | 1–2000 mL |
| Max. Sensor Units Supported | 2 (lab-grade microwave sensors) |
| Calibration Profiles | Up to 200 product-specific calibration curves |
| Software | Pre-installed TEWS Moisture View© |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Sensor Types | Tubular, Planar, Fork-Type, TipTop & Custom Configurations |
| Application Scope | Laboratory QC, In-Line Process Monitoring, Batch Sampling |
| Material Compatibility | Powders, Granules, Tablets, Sheets, Fibers, Pellets, Non-Adhesive Bulk Solids |
| Construction | Stainless Steel (AISI 316L) + High-Strength Alumina Ceramic |
| Interface | Analog 4–20 mA / Digital RS-485 / EtherNet/IP (compatible with TEWS MW-E Series Electronics, excluding MW-T) |
| Compliance | CE, RoHS, ATEX Zone 22 (optional), ISO/IEC 17025 traceable calibration support |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW3012 |
| Measurement Principle | Microwave Absorption Spectroscopy (2.45 GHz) |
| Moisture Range | 10 ppm – 20 wt% |
| Sampling Rate | Up to 40,000 measurements per second |
| Response Time | < 1 ms |
| Sample Types | Powders, granules, tablets, capsules, fibers, films, sheets, yarns, cigarettes |
| Output | Simultaneous moisture content (%) and bulk density (g/cm³) |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible workflows |
| Interface | RS-485, Ethernet (TCP/IP), 4–20 mA analog output |
| Operating Temperature | 0–50 °C |
| Enclosure Rating | IP65 |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-WS3 |
| Titration Method | Manual & Automated Coulometric/Volumetric |
| Moisture Range | 0.01 µg – 100% (w/w) |
| Detection Limit | 0.01 µg H₂O |
| Accuracy | ±2 µg (for 5–1000 µg), ±0.2% (for >1 mg, excluding sampling error) |
| Repeatability | ≤2% RSD |
| Titration Resolution | 0.1 µL (volumetric) / ±0.1 µA (coulometric current resolution) |
| Electrolysis Rate | 2 min per titration |
| Stirring Speed | 10 adjustable levels |
| Zero-Balance Time | ≤1 min |
| Power Supply | 12 V DC / 3 A |
| Operating Environment | 5–40 °C, <85% RH |
| Dimensions | 235 × 270 × 130 mm |
| Weight | 2.0 kg |
| Data Storage Capacity | >200,000 records |
| Compliance | GB/T 7600, GB 6283, SH/T 0246, SH/T 0255, GB/T 11133, GB/T 7380, GB 10670, GB/T 606, GB/T 8350, GB/T 8351, GB/T 3776.1, GB/T 6023, GB/T 3727, GB/T 7376, GB/T 18619.1, GB/T 1600, GB/T 11146, GB/T 12717, GB/T 18826, Chinese Pharmacopoeia (ChP) General Chapter 0832 |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | TRQ-600 |
| Type | Online Dew Point Meter |
| Principle | Ceramic Capacitive Sensor (Not Semiconductor — Corrected per Technical Specification) |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 °C dp (at +20 to -60 °C) |
| Repeatability | 0.5 °C dp |
| Response Time (T95) | 5 min (dry-to-wet) |
| Measurement Range | -100 to +20 °C dew point |
| Moisture Output Range | 0–3000 ppmv |
| Analog Output | 4–20 mA (2-wire, current loop) |
| Supply Voltage | 12–28 V DC |
| Max Load Resistance | 250 Ω @ 12 V |
| Max Current Consumption | 23 mA |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ST-1513A |
| Price Range | USD 1,400 – 7,000 |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | ST-1523 |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 1 µg to 200 mg |
| Resolution | 0.1 µg |
| Accuracy | ±3 µg for 5–1000 µg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-100A-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Time Setting | 1–99 min (1 min increments) |
| Temperature Range | 50–160 °C |
| End Point Control | Timer-based or Auto-termination |
| Display | Backlit dot-matrix LCD showing moisture %, solids %, weight, elapsed time |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-10A |
| Heating Method | Halogen Lamp |
| Display | High-Resolution Backlit Dot-Matrix LCD |
| Interface | RS-232C |
| Features | Automatic Tare, Zero Drift Compensation, Real-Time Dryness Monitoring |
| Compliance | Designed for ISO 5725 (accuracy & reproducibility), ASTM E1447 (moisture in solids), and USP <921> (Loss on Drying) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 Halogen Moisture Analyzer |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| End Point Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight (g), Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Endpoint Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight, Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Interface | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-5 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–50 g |
| Readability | 5 mg |
| Temperature Range | 50–160 °C |
| Heating Time | 1–99 min (1-min increments) |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Repeatability (3 g sample) | ±0.3% |
| Display | Backlit dot-matrix LCD |
| Interface | RS232 |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| End-point Modes | Timed & Automatic |
| Heating Profile | Standard |
| Display Outputs | Moisture %, Solid %, Sample Weight, Elapsed Time |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | TSF-50A-5 |
| Heating Source | Halogen Lamp |
| Display | 4.3-inch Capacitive Touchscreen LCD |
| Readability | 0.01% / 1 mg |
| Compliance | GB/T 29249–2012 (Electronic Moisture Analyzer Based on Drying Method) |
| Interface | RS232 for Printer & PC Connectivity |
| Data Output | Real-time Drying Curve, Auto-finalization, Lock-on-Completion |
| Brand | Yuntang |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-NIR-T |
| Heating Method | Infrared |
| Measurement Range | 0–100% w/w |
| Accuracy | ±0.2% w/w (subject to material composition variation) |
| Light Source | Imported high-efficiency NIR source |
| Filter Cycle | 1–60 s |
| Illumination Diameter | 60–75 mm |
| Working Height | 350 mm + 100 mm tolerance |
| Measurement Channels | 50 |
| Probe Window Material | High-borosilicate quartz glass |
| Operating Environment | −40 °C to +70 °C, 5–95% RH (non-condensing) |
| Power Supply | 220 VAC / 50 Hz |
| Communication Interfaces | RS485, 4–20 mA analog output, RS232, Ethernet (LAN), LoRa wireless |
| Enclosure Rating | IP65 |
| Display | Integrated industrial touchscreen |
| Probe Housing | High-strength aluminum alloy |
| Brand | ZRTB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZB-305A |
| Maximum Capacity | 120 g |
| Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Heating Source | Halogen Lamp (Room Temp–180 °C, 1 °C Increments) |
| Drying Modes | Standard / Rapid / Gentle |
| Termination Modes | Auto-Stop / Timed Stop / Manual Stop |
| Weighing Sensor | HBM (Germany) |
| Processor | ARM (UK) |
| Calibration Weight | 100 g |
| Pan Diameter | φ110 mm |
| Interface | RS232 |
| Dimensions (L×W×H) | 330 × 205 × 165 mm |
| Application | Multi-industry moisture determination in plastics, polymers, pharmaceuticals, food, and chemicals |