| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S5200 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | 120 vials (2 × 60-position trays) |
| Standard Loop Volume | 20 µL (exchangeable) |
| Precision | RSD < 0.5% (fixed-volume mode) |
| Carryover | < 0.01% (low-pressure wash) |
| Programmable Wash Protocol | Yes |
| Control Interface | Analog signal or RS-232 digital |
| Dimensions | 415 × 300 × 445 mm |
| Weight | ~20 kg |
| Brand | CETAC |
|---|---|
| Origin | Imported |
| Model | Aridus3 |
| Instrument Type | Multifunctional Autosampler for ICP-MS/ICP-OES |
| Construction Materials | PFA-only fluid path |
| Nebulizer Type | Low-flow, micro-consumption concentric nebulizer |
| Desolvation Technology | Heated hydrophobic membrane-based solvent removal |
| Waste Liquid Handling | Active vacuum-assisted back-purge |
| Gas Control | Integrated mass flow controllers (MFCs) for carrier and make-up gases |
| Software Interface | Aridus Link with remote temperature and flow setpoint control |
| Compliance | Compatible with GLP/GMP workflows |
| Safety | Full PFA compatibility enables direct analysis of HF-containing matrices (e.g., geological digests, semiconductor etchants) |
| Brand | CETAC |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | U5000AT+ |
| Instrument Type | Multifunctional Autosampler for ICP-OES and ICP-MS |
| Nebulization Principle | High-Efficiency Ultrasonic Nebulization (USN) |
| Detection Limit Improvement | 5–25× vs. Conventional Pneumatic Nebulizers |
| Compatibility | Integrated with Teledyne CETAC Apex Q, Apex HF, and standard ICP/OES/MS sample introduction systems |
| Energy Control | Closed-loop automatic RF power tuning for real-time droplet size stabilization |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AI/AS 1310 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity | 8-position (AI 1310) or 155-position (AS 1310) |
| Needle Wash Options | Single or dual-solvent (A/B/C/D, A+B, C+D) pre- and post-injection |
| Injection Modes | Minimum Needle Depth & Standard Needle Depth |
| Compatibility | Thermo Scientific GC systems (e.g., TRACE 1300/1600 series) |
| Upgrade Path | AI 1310 → AS 1310 |
| Optional Dual-Inlet Kit | AS 1310 Gemini Kit (enables simultaneous dual-port injection) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-AP |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 1152 positions (microtiter plate) / 81 vials (10 mL) |
| Injection Cycle Time | <30 s for 5 µL injection |
| Precision | RSD <0.3% |
| Fluidic Path | Full PEEK™ construction |
| Needle Design | Moving-needle architecture |
| Temperature Control | 4–60 °C sample tray cooling |
| Integrated Pre-injection Analysis | Conductivity & pH measurement |
| Automation Capabilities | Automated internal standard addition, on-line dilution, pre-column derivatization, matrix removal, analyte preconcentration, fraction collection, re-injection, and sample ejection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-DV |
| Instrument Category | Multifunctional Autosampler |
| Fluidic Path Material | PEEK™ |
| Compatible Systems | All Dionex ICS Ion Chromatography Systems |
| Sample Vial Capacity | 5.0 mL and 0.5 mL polymer vials |
| Valve Options | Optional 6-port or 10-port switching valves |
| Software Control | Thermo Scientific Chromeleon CDS (v7.3 or later) |
| Audit Trail & Electronic Signatures | Compliant with 21 CFR Part 11 |
| Dual-IC System Operation | Supported |
| Sample Overlap Injection | Enabled |
| Filtration Option | Available with filter cap accessory |
| Detection Limit Enhancement | Via automated on-line preconcentration and matrix elimination |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-HV |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 250 mL |
| Syringe/Pump Options | Syringe, Peristaltic, or Piston Pump |
| Rack Compatibility | 21-position (50 mL vials, 30 mm O.D.), 24-position (26 mL vials, 24 mm O.D.), 40-position (15 mL vials, 20 mm O.D.), 60-position (10 mL vials, 16 mm O.D.), or 21-position (60/40 mL ASE™ Collection Vials) |
| Fluid Path Material | All-PEEK™ |
| Loading Mode | Programmable “push” or “pull” |
| Arm Motion | High-speed, high-precision robotic positioning |
| Footprint | Compact benchtop design |
| Optional Integration | Dionex AutoPrep™ system, RFIC™-ESP platform, trace analysis cover |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | SSL Inlet |
| Instrument Type | Gas Chromatography Injector |
| Compatibility | GC and GC-MS systems |
| Operating Modes | Split, Splitless, Cool-on-Column (COC), Large Volume Injection (LVI) |
| Thermal Management | Optimized heater profile with minimal thermal stress on septum |
| Septum Compatibility | Merlin Microseal™ (with adapter) |
| Column Compatibility | Capillary columns (50–530 µm ID) |
| Maintenance Design | Tool-free, top-access inlet body with removable liner and septum assembly |
| Oxygen-Free Operation | Certified inert flow path for high-fidelity transfer to mass spectrometers |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PTV Inlet |
| Instrument Type | Gas Chromatography (GC) Programmable Temperature Vaporizing Inlet |
| Temperature Range | Ambient +5 °C to 450 °C (standard) |
| Optional Cryogenic Cooling | Liquid Nitrogen to –100 °C or CO₂ to –50 °C |
| Max Ramp Rate | 870 °C/min |
| Programmable Temperature Steps | Up to 3 gradients |
| Compatible Autosamplers | Thermo AI/AS 1310 (requires syringe 365D1831), TriPlus 100LS & TriPlus RSH (requires syringe 365D0391) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Italy |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TriPlus 500 |
| Instrument Category | Multifunctional Headspace Autosampler |
| Software Compliance | 21 CFR Part 11 |
| Validation Support | Built-in IQ/OQ/PQ and System Suitability Test Wizards |
| Sample Capacity | Expandable from 12 to 240 vials |
| Shaking Technology | Patented Quick Spin Shaking |
| Gas Path Design | Direct quantitative loop–GC column coupling with integrated leak detection and purge control |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | TriPlus RSH |
| Instrument Category | Gas Chromatography Autosampler |
| Sample Capacity | 972 × 2 mL vials + multiple 100 mL wash/waste bottles |
| Needle Exchange | Automatic Tool Change (ATC) |
| Minimum Sample Uptake | 5 µL (with bottom-sensing precision) |
| Liquid Injection Modes | Conventional, Fast (<100 ms), Sandwich |
| Headspace Capacity | 300 × 10/20 mL vials |
| SPME Automation | Full cycle (conditioning, extraction, desorption, cleaning) |
| Integrated Functions | Continuous dilution, spiking, derivatization, vortexing, barcode reading |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TriPlus 100 LS |
| Instrument Type | Gas Chromatography Autosampler |
| Price Range | USD 13,500 – 27,000 (FOB) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Thermo Fisher OEM/ODM partnership) |
| Model | iSC-65 |
| Voltage | 100–240 VAC |
| Rack Capacity | 4 × (21 / 24 / 40 / 60 / 90 vial positions) |
| Rack Options | 10-position 50 mL round- or flat-bottom standard rack |
| Rinse System | Dual-channel variable-speed rinse pump with Luer-lock fittings |
| Motion Control | X/Y/Z drive obstruction detection |
| Rinse Logic | Step Ahead™ (rinse sequence initiated during ongoing analysis) |
| Display | Multi-color LED status interface |
| Software Integration | Fully embedded in Thermo Scientific Qtegra™ ISDS Software (v3.5+) for alignment, method setup, and real-time parameter control |
| Connectivity | Ethernet (TCP/IP), 2 auxiliary I/O ports |
| Environmental Certification | ACT Label (My Green Lab verified) |
| Compatible Instruments | iCAP PRO X, PRO XP, PRO XPS ICP-OES |
| Unit Size | Each |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AMSP-100 |
| Instrument Type | Multifunctional Autosampler |
| Sample Introduction Modes | Headspace, Liquid Injection, Solid-Phase Microextraction (SPME) |
| Automation Features | Automatic Needle Exchange, Bottle Bottom Detection, Collision Detection, Oscillatory Mixing |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software Interface | RS-232/USB/Ethernet-compatible control protocol |
| Brand | Youlian Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3265 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | Up to 120 vials (configurable trays) |
| Injection Volume Range | 3–250 µL |
| Precision | RSD < 0.5% (peak area, typical) |
| Carryover | < 0.02% |
| Wash Volume | 0–250 µL (adjustable) |
| Wash Cycles | 1–9 (user-selectable) |
| Syringe Capacity | 250 µL |
| Gradient Accuracy | ±1% |
| Operating Temperature | 10–30 °C |
| Sample Cooling Range | 4–40 °C (±2 °C stability) |
| Display | 4.3-inch TFT LCD touchscreen |
| Controller | 32-bit ARM7 embedded microprocessor |
| Communication | RS-232 / RS-485 |
| Injection Mode | X-Y-Z robotic motion with repeat-injection capability (1–99× per vial) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | AS1020 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | 120 × 1.8 mL vials (2 × 60-position racks) |
| Injection Modes | Full-loop, Partial-loop, and Needle-Over-Loop (NOL) / Zero-dead-volume injection |
| Minimum Injection Volume | 0.1 µL (with 250 µL syringe pump) |
| Syringe Pump Volume | 250 µL (standard) |
| Loop Volume | 100 µL (standard) |
| Injection Valve Switching Time | <100 ms |
| Positioning Accuracy | <0.3 mm |
| Motion Architecture | XYZ three-axis Cartesian coordinate system |
| Needle Wash | Dual internal/external wash with programmable unlimited rinse cycles |
| Carryover | <0.01% |
| Precision (RSD) | <0.5% |
| Linearity (r²) | >0.999 |
| Dimensions (W×D×H) | 300 × 505 × 230 mm |
| Power Supply | AC 220 V, 50 Hz |
| Operating Temperature Range | 10–40 °C |
| Brand | VICI |
|---|---|
| Model | PS-050025 |
| Volume | 100 µL |
| Needle | RN (Removable Needle), Bevel Tip, 0.029" OD × 0.005" ID × 2" L |
| Maximum Pressure Rating | 250 psi |
| Seal Material | PTFE Plunger Tip & Needle Seal |
| Barrel Material | Glass |
| Valve Type | Integrated Push-Button Actuated On/Off Valve |
| Compliance | Designed for GLP/GMP-compliant chromatographic workflows requiring trace-level sample integrity |
| Brand | Wufeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Arcus 5 |
| Instrument Type | HPLC Autosampler |
| Max Sample Capacity | 192 × 1 mL vials |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 50 µL (configurable) |
| Positioning Accuracy | ±0.1 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal & external wall washing |
| Mechanical Durability | ≥1,000,000 injection cycles |
| Sample Carryover | <0.05% |
| Injection Precision | RSD <0.25% (full-loop), <0.5% (partial-loop, >10 µL), <0.8% (low-volume, <5 µL) |
| Max System Pressure | 40 MPa (standard HPLC), 60 MPa (UHPLC-compatible) |
| Sample Tray Options | 2 mL × 108 vials (standard) or configurable layouts |
| Injection Modes | Full-loop, Partial-loop, and Zero-dead-volume (ZDV) injection |
| Brand | Wufeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ARCUS 7 |
| Instrument Type | HPLC Autosampler |
| Max Sample Capacity | 192 × 1 mL vials |
| Minimum Injection Volume | 0.1–120 µL |
| Loop Volume Range | 0.1–120 µL |
| Positioning Accuracy | ±0.1 µL at 200 µL |
| Motion Architecture | XYZ 3-axis robotic arm |
| Needle Wash | Internal & external wall washing, unlimited cycles |
| Re-injection Capability | Unlimited repeat injections |
| Sample Tray Configurations | (1) 54 × 2 mL (standard), (2) 15 × 10 mL, (3) 35 × 4 mL, (4) 96 × 1 mL — dual-side modular trays, auto-recognized, max 192 positions (1 mL vials) |
| Max Vial Height | ≤52 mm (including septum & cap) |
| Pump Volume | 200 µL (accuracy ±0.1 µL) |
| Sampling Modes | Full-loop, Partial-loop, and Zero-dead-volume (ZDV) sampling |
| Carryover | ≤0.005% (with validated wash protocol) |
| Max System Pressure Tolerance | 60 MPa |
| Safety Protections | Vial-missing detection, needle-strike alarm, plunger/piston stall detection, leak sensing |
| Power Supply | AC 115–230 V, 50/60 Hz |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-D-12 |
| Heating Zones | 3 (Headspace Oven, Transfer Line, Six-Port Valve) |
| Temperature Range (Headspace Oven) | Ambient to 260 °C (1 °C adjustable increment) |
| Temperature Range (Transfer Line & Valve) | Ambient to 220 °C (1 °C adjustable increment) |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 12 × 10 mL or 20 mL vials |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Precision (RSD) | <1.5% for 200 ppm ethanol in water |
| Power Consumption | 1000 W |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 420 mm × 180 mm × 500 mm |
| Weight | ~17.5 kg |
| Brand | Zhonghui Pu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GI Series |
| Instrument Type | Gas Chromatography Gas Bag Autosampler |
| Maximum Sample Capacity | 136 positions |
| Optional Heating Range for 6/10-Port Valve | 40–240 °C (±1 °C) |
| Optional Heating Range for Transfer Line | 40–240 °C (±1 °C) |
| Sample Position Options | 34 / 68 / 102 / 136 |
| RSD | ≤1% (at 100 ppm methane) |
| Power Consumption | Main Unit — 100 W (avg) |
| Dimensions (L×W×H) | Main Unit — 520 × 520 × 550 mm |
| Backflush Flow Rate | 10–1000 mL/min |
| Net Weight | ~30 kg |
| Optional Features | Integrated Dynamic Dilution Module, Dual-Channel 10-Port Valve Configuration, PTFE Seals, RESTEK Siltek®/Sulfinert®-Treated Stainless Steel Quantitative Loop |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AS-30G |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 30 samples |
| Construction Materials | PEEK-lined fluidic path and valve manifold |
| Sampling Interface | Gas-tight syringes and Tedlar®/FlexFoil® gas bags |
| Integrated Features | Automated line purge & rinse cycle, flow-controlled sampling, PC-based control software, optional wireless communication module, optional temperature-stabilized sample enclosure |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AS-60G |
| Maximum Sample Capacity | 60 positions |
| Interface Compatibility | GC-compatible (TTL/RS-232) |
| Temperature Control Range | Ambient to 200 °C (valve & transfer lines) |
| Injection Volume Accuracy | ±1% RSD (with calibrated loop) |
| Cleaning Protocol | Automated pre- and post-injection purge with carrier gas |
| Sample Introduction Options | Gas-tight syringe, Tedlar® bag, or stainless-steel sampling canister |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Positions | 16 |
| Standard Quantitative Loop Volume | 100 µL (customizable) |
| Leak Detection | Pre-valve-opening automated leak check |
| Flow Path Treatment | Passivated (inertized) tubing and valves |
| Cleaning Protocol | Software-controlled reverse-flush for all flow paths |
| Valve Architecture | Multi-position rotary valve |
| Control Interface | PC-based method programming with unattended operation (scheduled, repetitive, continuous injection) |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | STP-6 |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Positions | 6 |
| Repeat Injection Capability | Unlimited cycles per tube |
| Flow Control | Mass Flow Controller (MFC) |
| Vaporization Chamber | Heated, Temperature-Controlled |
| Valve Architecture | Integrated Solenoid Valve Manifold |
| User Interface | Standalone Touchscreen Control Panel |
| Power Supply | 220 V / 110 V (±10%), 50 Hz / 60 Hz (±2%) |