Empowering Scientific Discovery

Nanjing Chuandi Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChuandi
ModelDDB-12B
TypePortable Conductivity Meter
Measurement ParameterSingle-parameter (Conductivity)
Conductivity Range0–20 mS/cm
Resistivity Range0–1 MΩ
Salinity Range0.01–0.3 mol/L
Temperature Compensation Range5–40 °C
Accuracy<1% FS
Minimum Resolution0.1 µS/cm
Electrode Constant InputUser-configurable (for automatic conductivity calculation)
Power SupplyTwo AA (1.5 V) batteries
Operating Ambient−10 to +60 °C, RH <90%
Dimensions135 × 65 × 24 mm
Weight<0.16 kg
Linearity (Voltage vs. Conductance)≥98%
ComplianceDesigned for field-deployable soil salinity and aqueous solution monitoring in accordance with standard electrochemical measurement practice
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelDDB-2 / DDB-3
PortabilityHandheld
Conductivity Range1 µS to 100 mS (5 auto-ranging decades)
Accuracy±1.5% FS
Temperature Compensation Error<±2%
Stability±0.1% FS ±1 digit/hour
Weight380 g (incl. batteries)
Dimensions180 × 100 × 40 mm
PowerTwo AA (1.5 V) batteries
Operating Temp0–45 °C
RH Limit≤85%
DDB-3 Additional FunctionIntegrated Temperature Measurement (–10 to 100 °C, resolution 0.1 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelCD-12
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelFJA-8
Price RangeUSD 430–710 (FOB)
Measured ParametersConductivity, TDS, Resistivity, Salinity, Temperature
PortabilityHandheld
Application EnvironmentField, Laboratory, Soil Monitoring
Conductivity Range1 µS/cm – 10 mS/cm (5 auto-ranging decades)
TDS Range0–100 g/L
Resistivity Range0–10 MΩ·cm
Salinity Range0–0.3 mol/L
Temperature Range0–60 °C
Accuracy±2% of reading ± 0.01 µS/cm
Minimum Resolution0.001 µS/cm
Data Storage200 readings
Power SupplyRechargeable 8.4 V Li-ion battery
Dimensions183 × 130 × 60 mm
Weight< 0.5 kg
Operating Temp.0–45 °C
Relative Humidity≤85% RH
InterfaceUSB for PC data export
Software SupportFJA-6 Series PC Application Suite (data logging, calibration history, CSV export)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelFJA-10
PortabilityHandheld / Field-Deployable
Calibration CompatibilityKCl/NaCl standard solutions (0.01–0.2 mol/L)
Electrode MaterialGraphite
Temperature CompensationIntegrated NTC thermistor
Response Time<20 s
Minimum Volumetric Water Content for Reliable Measurement~20% (varies with clay content)
Electrode ConstantAdjustable (factory-set to 100 cm⁻¹ for direct mS/cm readout)
Linearity (0.02–0.3 N)R² ≥ 0.98
RepeatabilityRelative average deviation ≤5% (max. 10%)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelFJA-6
PriceUpon Request
Form FactorBenchtop
Conductivity Range1 μS to 100 mS (5 auto-ranging spans)
Accuracy±1.5% of reading
Temperature Compensation Error<±2%
Stability±0.1% FS ±1 digit/hour
Dimensions183 × 130 × 60 mm
Weight<0.5 kg
Operating Temp0–45 °C
RH Limit≤85%
Power Supply5 V DC
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0