Empowering Scientific Discovery

Nanjing Chuandi Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelMIA-4
Instrument TypeMercaptan Sulfur & Basic Nitrogen Analyzer
Measurement Range≥3 µg/g
Potentiometric Range0 to ±1999.9 mV, Resolution: 0.1 mV
Accuracy±0.025% of reading + 2 digits
Input Impedance≥1 × 10¹² Ω
Burette Capacity10 mL, Minimum Dispensing Volume: 0.01 mL
Relative Error≤5%
RepeatabilityCompliant with GB/T 1792 and ASTM D3227
Dimensions (W×D×H)240 × 120 × 210 mm
Weight5 kg
Power Consumption≤10 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelJXD-2
Instrument TypeAlkaline Nitrogen & Mercaptan Sulfur Analyzer
Measurement Range≥3 µg/g
Potential Range0 to ±1999.9 mV, Resolution: 0.1 mV
Potential Accuracy±0.025% of reading + 2 digits
Input Impedance≥1 × 10¹² Ω
Burette Capacity10 mL, Minimum Dispense Volume: 0.01 mL
Relative Error≤5%
RepeatabilityCompliant with SH/T 0162
Dimensions240 × 120 × 210 mm
Weight5 kg
Power Consumption≤10 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelDAB-2
Price RangeUSD 700 – 7,000
Instrument TypeGeneral-Purpose Potentiometric Titrator
Display Resolution0.01 mL
PrecisionCV ≤ 0.3%
Power Supply12 V DC (battery-compatible)
Communication InterfaceRS232
Syringe Capacity10 mL
Valve MaterialPTFE rotary valve
CalibrationUser-performed gravimetric calibration via titration factor adjustment
Control SignalsBusy output, pulse-triggered titration input, TTL-level stop/drop control input
Operating ModeContinuous titration with auto-refill and void compensation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChuandi
OriginJiangsu, China
Instrument TypeUniversal Potentiometric Titrator
Voltage Measurement Range−1999.9 mV to +1999.9 mV
Voltage Resolution0.1 mV
Voltage Accuracy±0.025% of reading ±2 digits
Input Impedance>10¹² Ω
Titration Precision0.01 mL
Minimum Dispensed Volume0.001 mL
Titration Error<0.2% (using 0.1 mol/L HCl vs. 0.1 mol/L NaOH)
Communication InterfaceRS-232 (USB-compatible via adapter)
Software Modules25 preconfigured titration & analytical methods (potentiometric, photometric, amperometric, coulometric, Karl Fischer water determination, acid-base, redox, complexometric, precipitation, pH-metric, and endpoint detection algorithms)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelFJA-2
Instrument TypeUniversal Potentiometric Titrator
Voltage Measurement Range−1999.9 to +1999.9 mV
Resolution0.1 mV
Voltage Accuracy±0.025% of reading ±2 digits
Input Impedance>10¹² Ω
Titration Precision0.01 mL
Minimum Dispensed Volume0.001 mL
Titration Error≤0.2% (using 0.1 mol/L HCl vs. 0.1 mol/L NaOH)
ComplianceGB/T 1792–1988 (mercaptan sulfur in petroleum products)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0