BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTransient Plane Source Method
Thermal Conductivity Range0.0001–300 W/(m·K)
Accuracy±3%
Repeatability≤3%
Measurement Time5–160 s
Sample FormsSolid blocks, pastes, granules, gels, liquids, powders, coatings, thin films
Probe Diameters7.5 mm, 15 mm, 50 mm (optional)
Sample Dimensions (min.)15×15×3.75 mm (for 7.5 mm probe), 30×30×7.5 mm (for 15 mm probe), 50×50×7.5 mm (for 50 mm probe)
Operating TemperatureAmbient to 130 °C
Power SupplyAC 220 V, <500 W
Dimensions (L×W×H)440×390×220 mm
ComplianceDesigned for ISO 22007-2, ASTM D5470, and GB/T 32064–2015 conformance
SoftwareEmbedded ARM-based control system with real-time data acquisition, GLP-compliant audit trail, and exportable CSV/Excel reports
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelDTA-3320A
Instrument TypeDifferential Thermal Analyzer (DTA)
Temperature RangeAmbient to 1150 °C
Temperature Accuracy±0.1 °C
Temperature Resolution0.01 °C
Temperature Repeatability±0.1 °C
Heating/Cooling Rate0.1–100 °C/min
DTA Signal Range0–±2000 µV (expandable)
DTA Sensitivity0.01 µV
Baseline AdjustmentAdjustable slope and intercept
CalibrationIntegrated standard reference materials with one-click temperature calibration
Control SystemARM-based embedded controller
InterfaceUSB 2.0 bidirectional communication
Display7-inch 24-bit color LCD touchscreen
Furnace DesignTop-opening vertical furnace architecture
Atmosphere ControlProgrammable internal gas switching (N₂, Ar, air, O₂)
Power SupplyAC 220 V, 50 Hz (custom voltage/frequency available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method (Parallel-Plate Capacitor Configuration)
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Tuning Capacitance17–240 pF (silver-plated monolithic capacitor)
Capacitance Direct Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Error±1 pF or <1%
Automatic Capacitance SearchYes (stepper motor-driven)
Residual & Lead Inductance CompensationYes
DisplayLCD showing F, L, C, Q, Lt, Ct, εᵣ, tanδ, Tn
ComplianceGB/T 1693–2007, ASTM D150, GB 9622.9–1988 / SJ/T 11043–1996