| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Control | PID-based Automatic Programmed Control |
| Thermal Environment | Triple-layer insulated furnace lid |
| Atmosphere Control | Dual-gas inlet with automatic switching (0–200 mL/min, ≤0.5 MPa) |
| Data Interface | Standard USB |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, six-segment programmable thermal profiles, real-time bidirectional control (instrument + PC) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard range), 1 mg to 2 g (high-precision range) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Accuracy | 0.01 mg |
| Minimum Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas channel with integrated mass flow meters |
| Display | 7-inch high-resolution Chinese-language LCD touchscreen |
| Data Interface | Standard USB port |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel export, PDF report generation, thermal calibration correction (multi-point), and FDA 21 CFR Part 11–compliant audit trail (optional module) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-DSC1000 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 1050 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), plus dedicated purge gas inlet |
| Gas Flow Range | 0–300 mL/min |
| Max Gas Pressure | ≤1 MPa |
| Control Method | PID-based automated temperature programming |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Display | 7-inch industrial-grade LCD touchscreen |
| Calibration Standards Included | Indium and Tin reference materials |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Price | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −40 °C/min (cooling) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Sample Capacity | 30 g max |
| Mass Measurement Range | 0.01 mg–3 g (expandable to 50 g) |
| Mass Accuracy | 0.01 mg |
| Mass Resolution | 0.01 µg |
| DSC Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Atmosphere Control | Integrated Digital Mass Flow Controller |
| Cooling Mode | Optional External Water Chiller (−10 to 60 °C) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TGA 101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.01 mg–2 g (expandable to 30 g) |
| Balance Sensitivity | 0.01 mg |
| Minimum Detection Limit | 0.1 µg |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Atmosphere Control | Dual-gas inlet with integrated mass flow meters |
| Display | 7-inch Chinese-language LCD |
| Data Interface | Standard USB |
| Software | Proprietary TGA analysis suite with TG/DTG curve processing, Excel export, PDF report generation, temperature multi-point calibration, and free version upgrades |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Model | DZ-STA200 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing |
| TG Resolution | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit LCD Touchscreen |
| Gas Control | Dual-channel mass flow control with integrated flow meters |
| Software | Integrated thermal analysis suite with TG, DTG, and TG-DSC overlay, calibration support (temperature & enthalpy), PDF/Excel export, audit-trail-capable data logging |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Model | DSC300 |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel automated switching (N₂, air, or custom gases) |
| Gas Flow Rate | 0–300 mL/min (customizable) |
| Gas Pressure Rating | ≤5 MPa |
| Thermal Control Modes | Programmable multi-step heating, isothermal hold, and cooling |
| Max Program Segments | 6 |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, baseline correction, peak integration, ASTM/ISO-compliant reporting templates |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single-sample |
| Instrument Type | General-purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard), extendable to 30 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | USB 2.0 |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel/PDF export, GLP-compliant audit trail, multi-point temperature calibration, and remote instrument control |
| Brand | NANJING DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC100A |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | USB 2.0 bidirectional communication |
| Control Architecture | ARM Cortex-M3 microcontroller |
| Calibration | Integrated standard reference materials with one-click temperature & enthalpy calibration |
| Power Supply | AC 220 V / 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.1 mg–3 g (extendable to 30 g) |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Acquisition | 48-bit quadruple-channel ADC for simultaneous TG, DTG, DSC (optional), and temperature signals |
| Interface | USB 2.0 (bidirectional) |
| Display | 7-inch 24-bit color touchscreen (Chinese/English UI) |
| Calibration | On-screen TG baseline and temperature multi-point calibration |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample per test |
| Test Environment | Ambient temperature (with optional environmental chamber integration) |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Temperature Range | –30 °C to 200 °C |
| Resolution | 0.00001 W/(m·K) |
| Repeatability | ≤1% RSD |
| Accuracy | ±2% (traceable to NIST-certified reference materials) |
| Sample Forms | Solids (bulk, thin films, foams), liquids, powders, pastes, gels, and elastomers |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 7.5 mm (Probe #1) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Time | ≤160 s per test |
| Power Consumption | <300 W |
| Display | 7-inch color capacitive touchscreen interface |
| Control Architecture | Bidirectional software–instrument communication (USB/Ethernet) |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC400 |
| Temperature Range | Ambient to 600 °C |
| DSC Measurement Range | ±800 mW |
| Temperature Accuracy | ±0.0001 °C |
| Temperature Precision | ±0.0001 °C |
| Heating Rate | 0.1–100 K/min |
| Cooling Rate | −0.1–20 K/min |
| Temperature Stability | ±0.1 °C |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| DSC Noise Level | 0.1 µW |
| Gas Flow Control | Dual-channel mass flow controller (0–200 mL/min), with auxiliary purge gas inlet |
| Cooling Options | Forced-air cooling (standard), optional Peltier and liquid nitrogen cooling modules |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-DSC300C |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | −40 to 600 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| Temperature Precision | ±0.01 °C |
| Temperature Stability | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual gas channels with auto-switching (including inert purge), max flow 300 mL/min, max pressure 5 MPa |
| Calibration Standards Included | Indium, Tin, Lead |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TGA 101 |
| Sample Capacity | Single-sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | Ambient to 1550 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.1 mg–2 g (extendable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | Standard USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | NANJING DAZHAN |
|---|---|
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static/dynamic) |
| Balance Resolution | 0.1 µg |
| Balance Accuracy | ±0.01 mg |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color touchscreen |
| Communication | USB 2.0 bidirectional interface |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, GLP-compliant report generation |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Isothermal Hold Duration | Up to 24 h |
| Atmosphere Control | Dual-gas automatic switching (N₂, Air, Ar, or custom), 0–200 mL/min flow, ≤0.5 MPa pressure |
| Control Mode | Fully programmable 6-segment heating/holding/cooling sequences with PID regulation |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, real-time baseline correction, GLP-compliant data logging |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Price Range | USD 21,000–28,000 |
| Temperature Range | Ambient to 1250 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −40 °C/min (cooling) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Maximum Sample Mass | 30 g (expandable to 50 g) |
| Mass Resolution | 0.01 mg |
| Mass Accuracy | ±1 mg |
| DSC Sensitivity | ±1000 mW |
| Atmosphere Control | Triple-gas mass flow control (digital MFCs) |
| Data Acquisition Interval | Real-time, 2 s, 5 s, or 10 s selectable |
| Cooling Time | ≤15 min (1000 °C → 50 °C) |
| External Water Cooling | Integrated chiller interface (−10 °C to 60 °C) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ5001 |
| Price Range | USD 2,800 – 7,000 |
| Measurement Principle | Resonant Cavity / Series Resonance Method with Automatic Q-Factor Tracking |
| Frequency Range | 10 kHz – 100 MHz (DDS Synthesized, 7000:1 Sweep Ratio) |
| Frequency Accuracy | ±3×10⁻⁵ ±1 digit (6-digit resolution) |
| ADC Resolution | 12-bit |
| Q Factor Range | 1–1000 (Auto/Manual Range, 4-digit display, 0.1 resolution) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution, <3% error) |
| Main Tuning Capacitor | 17–240 pF (monolithic silver-plated, high-stability) |
| Capacitance Direct Measurement | 1 pF – 25 nF (±1 pF or <1%, 0.1 pF resolution) |
| Capacitance Auto-Search | Stepper-motor-driven |
| Dielectric Constant (εᵣ) Accuracy | ±0.001 (LCD direct readout) |
| Dissipation Factor (tan δ) Accuracy | ±0.0001 (LCD direct readout) |
| Sample Thickness Range | 0.1 mm – 10 mm |
| Compliance | GB/T 1693–2007 |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ5001 |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Capacitance | 17–240 pF (silver-plated monolithic) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Automatic Residual Inductance Compensation | Yes |
| Sample Thickness Range | 0.1–10 mm |
| tanδ Resolution | 1×10⁻⁴ |
| εᵣ Resolution | 1×10⁻³ |
| Compliance | GB/T 1693–2007 |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Heat Flow Method |
| Model | DZDR-R |
| Dimensions (L×W×H) | 220 × 270 × 600 mm |
| Accuracy | Better than ±3% |
| Thermal Conductivity Range | 0.015–10 W/m·K |
| Repeatability | ≤3% |
| Sample Size | 100 mm × 100 mm |
| Sample Thickness | 2–15 mm |
| Operating Temperature Range | Ambient to 80 °C |
| Power Supply | 220 V / 50 Hz |
| Compliance Standards | MIL-I-49456A, GB 5598–1985, ASTM D5470–95 |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region Classification | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Mass Resolution | 1 µg |
| Mass Accuracy | ±1 µg |
| Dynamic Weighing Capacity | 0.01 mg–3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Load | 50 g |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Balance Sensitivity | 0.01 mg |
| Balance Range | 0.01 mg–3 g (extendable to 30 g) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Programmable Stages | Up to 5 temperature segments |
| Isothermal Hold Duration | 0–300 min per segment (configurable up to 72 h total) |
| Display | 7-inch Chinese-language LCD |
| Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | Ambient to 130 °C (extendable to 300 °C) |
| Sample Forms | Solid, Liquid, Gel, Paste, Powder |
| Probe Options | 7.5 mm, 15 mm, 50 mm diameter planar sensors |
| Measurement Time | 5–160 s |
| Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Power Supply | AC 220 V, <500 W |
| Sample Size Requirements | ≥15×15×3.75 mm (for 7.5 mm probe), ≥30×30×7.5 mm (for 15 mm probe), ≥50×50×15 mm (for 50 mm probe) |
| Compliance | ASTM D5334, ISO 22007-2, GB/T 32064–2015 |