- All
- Favorite
- Popular
- Most rated
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Control | PID-based Automatic Programmed Control |
| Thermal Environment | Triple-layer insulated furnace lid |
| Atmosphere Control | Dual-gas inlet with automatic switching (0–200 mL/min, ≤0.5 MPa) |
| Data Interface | Standard USB |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, six-segment programmable thermal profiles, real-time bidirectional control (instrument + PC) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-DSC1000 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 1050 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), plus dedicated purge gas inlet |
| Gas Flow Range | 0–300 mL/min |
| Max Gas Pressure | ≤1 MPa |
| Control Method | PID-based automated temperature programming |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Display | 7-inch industrial-grade LCD touchscreen |
| Calibration Standards Included | Indium and Tin reference materials |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Model | DSC300 |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel automated switching (N₂, air, or custom gases) |
| Gas Flow Rate | 0–300 mL/min (customizable) |
| Gas Pressure Rating | ≤5 MPa |
| Thermal Control Modes | Programmable multi-step heating, isothermal hold, and cooling |
| Max Program Segments | 6 |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, baseline correction, peak integration, ASTM/ISO-compliant reporting templates |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC100A |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | USB 2.0 bidirectional communication |
| Control Architecture | ARM Cortex-M3 microcontroller |
| Calibration | Integrated standard reference materials with one-click temperature & enthalpy calibration |
| Power Supply | AC 220 V / 50 Hz |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC400 |
| Temperature Range | Ambient to 600 °C |
| DSC Measurement Range | ±800 mW |
| Temperature Accuracy | ±0.0001 °C |
| Temperature Precision | ±0.0001 °C |
| Heating Rate | 0.1–100 K/min |
| Cooling Rate | −0.1–20 K/min |
| Temperature Stability | ±0.1 °C |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| DSC Noise Level | 0.1 µW |
| Gas Flow Control | Dual-channel mass flow controller (0–200 mL/min), with auxiliary purge gas inlet |
| Cooling Options | Forced-air cooling (standard), optional Peltier and liquid nitrogen cooling modules |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-DSC300C |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | −40 to 600 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| Temperature Precision | ±0.01 °C |
| Temperature Stability | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual gas channels with auto-switching (including inert purge), max flow 300 mL/min, max pressure 5 MPa |
| Calibration Standards Included | Indium, Tin, Lead |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Isothermal Hold Duration | Up to 24 h |
| Atmosphere Control | Dual-gas automatic switching (N₂, Air, Ar, or custom), 0–200 mL/min flow, ≤0.5 MPa pressure |
| Control Mode | Fully programmable 6-segment heating/holding/cooling sequences with PID regulation |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, real-time baseline correction, GLP-compliant data logging |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ3320C |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1500 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0 to ±2000 µV |
| Temperature Stability | ±0.1 °C |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Sensor Material | Pt-Rh Alloy |
| Interface | USB 2.0 Bidirectional |
| Display | 7-inch 24-bit Color TFT Touchscreen |
| Furnace Design | Top-opening Lid Structure |
| Atmosphere Control | Programmable Internal Gas Switching |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ3320A |
| Sample Capacity | Single |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Sensitivity | 0.01 µV |
| DTA Signal Range | 0–±2000 µV (expandable) |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Control Method | PID Temperature Control |
| Furnace Design | Top-opening vertical furnace |
| Atmosphere Control | Programmable internal gas switching |
| Data Interface | Standard USB 2.0 |
| Display | 7-inch 24-bit color LCD touchscreen |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Baseline Adjustment | Adjustable slope and intercept via software |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DZ-DSC100A |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Intelligent PID |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Sensor Material | Corrosion-Resistant Alloy |
| Gas Flow Control | Digital Mass Flow Meter |
| Interface | USB 2.0 Bidirectional Communication |
| Display | 7-inch 24-bit Color TFT Touchscreen |
| Calibration | Integrated Standard Reference Materials with One-Touch Temperature & Enthalpy Calibration |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DZ-DSC100A |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Control Mode | Fully Programmable Auto-Control |
| Atmosphere Control | Automated Gas Switching (N₂, Air, O₂) |
| Display | 7-inch 24-bit LCD Touchscreen |
| Interface | Standard USB 2.0 |
| Calibration | Certified Reference Materials Included |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | DZ-DSC300L |
| Sample Capacity | Single-sample |
| Temperature Range | −170 °C to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Atmosphere Control | Dual-gas auto-switching (N₂, Ar, O₂, or custom), flow rate 0–300 mL/min, max pressure ≤5 MPa |
| Thermal Program | Up to six segments (ramp/hold/cool), fully programmable |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DSC300C |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −40 °C to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.01 °C |
| DSC Signal Range | 0–±600 mW |
| Temperature Stability | ±0.01 °C |
| Brand | DZHAN |
|---|---|
| Model | DZ-DSC100A |
| Origin | Jiangsu, China |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Interface | USB 2.0 |
| Display | 7-inch 24-bit color TFT touchscreen |
| Power Supply | AC 220 V / 50 Hz |
| Compliance | Includes certified reference materials and one-click calibration for temperature and enthalpy |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Model | DT-3320C |
| Temperature Range | Ambient to 1500 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0 to ±2000 µV |
| DTA Sensitivity | 0.01 µV |
| DTA Accuracy | 0.1 µV |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Sensor Material | Pt-Rh Alloy |
| Interface | USB 2.0 Bidirectional |
| Display | 7-inch 24-bit Color LCD Touchscreen |
| Furnace Design | Top-Lifting Lid Configuration |
| Atmosphere Control | Programmable Internal Gas Switching |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DSC300C |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | -40 to 600 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0 to ±600 mW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 µW |
| Atmosphere Control | Dual gas channels with automatic switching, plus dedicated purge gas inlet |
| flow rate | 0–300 mL/min |
| max pressure | ≤5 MPa |
| Temperature Program | Up to 6 segments (ramp/hold) |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Calibration Standards Included | Indium, tin, lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Sample Capacity | Single-sample |
| Temperature Range | −40 to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| Temperature Accuracy | ±0.01 °C |
| Temperature Stability | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 µW |
| Atmosphere Control | Dual-gas auto-switching (N₂, air, or custom), plus dedicated purge gas inlet |
| Gas Flow Range | 0–300 mL/min |
| Max Gas Pressure | ≤5 MPa |
| Temperature Hold Time | User-defined |
| Thermal Program | Up to 6-segment ramp/hold sequences |
| Calibration Standards Included | Indium, Tin, Lead |
| Interface | USB 2.0 (auto-reconnect enabled) |
| Display | 7-inch 24-bit color TFT touchscreen |
| Power Supply | AC 220 V / 50 Hz (custom voltage options available) |
| Brand | NANJING DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | ±600 mW |
| Baseline Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Temperature Accuracy | ±0.001 °C |
| Atmosphere Control | Dual-gas auto-switching (N₂, Air, or custom gas) |
| Flow Rate | 0–300 mL/min |
| Max Pressure | ≤5 MPa |
| Thermal Program | Up to 6 segments (heating/holding/cooling) |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas automatic switching (N₂, Ar, air), flow rate 0–200 mL/min, max pressure 0.5 MPa |
| Thermal Program | Up to 6-segment ramp/hold/cool sequences, isothermal duration ≤24 h |
| Display | 7-inch 24-bit color TFT touchscreen |
| Data Interface | Standard USB 2.0 |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DSC 300 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.001 °C |
| Temperature Stability | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas automatic switching (programmable) |
| Gas Flow Rate | 0–300 mL/min (customizable) |
| Gas Pressure Rating | ≤5 MPa |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (custom voltage available) |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC100A |
| Price Range | USD 4,200–7,000 (FOB) |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Sensitivity | 0.01 mW |
| Gas Flow Control | Digital Mass Flow Controller (0–200 mL/min) |
| Display | 7-inch 24-bit color capacitive touchscreen LCD |
| Communication Interface | USB 2.0 (bidirectional) |
| Sensor Material | Corrosion-resistant alloy thermopile |
| Calibration | Integrated standard reference materials (e.g., In, Sn, Zn) with one-click auto-calibration for temperature and enthalpy |
| Power Supply | AC 220 V / 50 Hz (customizable for 110 V / 60 Hz) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DZ-DSC300C |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −40 °C to 600 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| Temperature Precision | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂, air, or user-specified), plus dedicated purge gas inlet |
| Gas Flow Range | 0–300 mL/min |
| Max Gas Pressure | ≤5 MPa |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.001 °C |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas automatic switching (0–300 mL/min, ≤5 MPa) |
| Temperature Calibration Standards | Indium, Tin, Lead included |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Model | DSC300L |
| Temperature Range | –170 °C to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0 mW to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Temperature Resolution | 0.001 °C |
| Temperature Stability | ±0.01 °C |
| Atmosphere Control | Dual-gas auto-switching (programmable), flow rate 0–300 mL/min, max pressure ≤5 MPa |
| Thermal Program | Up to 6-segment ramp/hold sequences |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
Show next