Empowering Scientific Discovery

Nanjing Dazhan Testing Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelDZ5001
Price RangeUSD 2,800 – 7,000
Measurement PrincipleResonant Cavity / Series Resonance Method with Automatic Q-Factor Tracking
Frequency Range10 kHz – 100 MHz (DDS Synthesized, 7000:1 Sweep Ratio)
Frequency Accuracy±3×10⁻⁵ ±1 digit (6-digit resolution)
ADC Resolution12-bit
Q Factor Range1–1000 (Auto/Manual Range, 4-digit display, 0.1 resolution)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH (0.1 nH resolution, <3% error)
Main Tuning Capacitor17–240 pF (monolithic silver-plated, high-stability)
Capacitance Direct Measurement1 pF – 25 nF (±1 pF or <1%, 0.1 pF resolution)
Capacitance Auto-SearchStepper-motor-driven
Dielectric Constant (εᵣ) Accuracy±0.001 (LCD direct readout)
Dissipation Factor (tan δ) Accuracy±0.0001 (LCD direct readout)
Sample Thickness Range0.1 mm – 10 mm
ComplianceGB/T 1693–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelDZ5001
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Capacitance17–240 pF (silver-plated monolithic)
Capacitance Direct Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Accuracy±1 pF or <1%
Automatic Residual Inductance CompensationYes
Sample Thickness Range0.1–10 mm
tanδ Resolution1×10⁻⁴
εᵣ Resolution1×10⁻³
ComplianceGB/T 1693–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method (Q-Factor Based)
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000
Q Resolution0.1 (4-digit effective)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Capacitance Range (Tuning)17–240 pF
Capacitance Direct Measurement1 pF – 25 nF
Capacitance Accuracy±1 pF or <1%
Capacitance Resolution0.1 pF
AD Sampling12-bit
Automatic Residual Inductance CompensationYes
Motorized Capacitor TuningYes
DisplayLCD with Real-Time Parameters (F, L, C, Q, Lt, Ct, εᵣ, Tn)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
ModelDZ5001
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Signal SourceDDS Digital Synthesis
ADC Resolution12-bit
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Tuning Capacitance17–240 pF (silver-plated monolithic capacitor)
Capacitance Direct Measurement Range1 pF – 25 nF
Capacitance Accuracy±1 pF or <1%
Capacitance Resolution0.1 pF
Automatic Capacitance SearchYes (stepper motor-driven)
Resonance DetectionAuto-scan
Q Pass/Fail ThresholdProgrammable (5–1000)
DisplayLCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc.
Residual Inductance CompensationSupported
Test Lead Inductance CompensationSupported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Tuning Capacitance17–240 pF (silver-plated monolithic capacitor)
Capacitance Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Error±1 pF or <1%
Automatic Residual Inductance CompensationYes
Auto-Resonance SearchYes (stepper motor–driven)
DisplayLCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc.
ComplianceDesigned for ASTM D150, IEC 60250, GB/T 1409, and ISO 18732-compliant dielectric characterization workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelDZ 5001
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Sampling Resolution12-bit ADC
Q Factor Range1–1000
Q Resolution0.1 (4-digit effective)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Tuning Capacitance17–240 pF (silver-plated monolithic)
Capacitance Direct Measurement Range1 pF – 25 nF
Capacitance Accuracy±1 pF or <1%
Capacitance Resolution0.1 pF
Automatic Resonance SearchYes (stepper motor–driven)
Display ParametersF, L, C, Q, Lt, Ct, Er, Tn, residual inductance, lead inductance correction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN (Nanjing Dazhan Instrument Co., Ltd.)
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method (Q-factor-based)
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000
Q Resolution0.1 (4-digit effective)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Tuning Capacitance17–240 pF (silver-plated monolithic capacitor)
Direct Capacitance Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Accuracy±1 pF or <1%
Automatic Capacitance SearchYes (stepper motor-driven)
Residual Inductance CompensationYes
DisplayLCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, tanδ
ComplianceGB/T 1409–2006, GB/T 1693–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelDZ5001
Price RangeUSD 1,400 – 4,200
Measurement PrincipleHigh-Frequency Resonance Method (Series/Parallel Resonant Circuit)
Frequency Range10 kHz – 100 MHz (DDS Synthesis, 7000:1 Sweep Ratio)
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Capacitance Range1 pF – 25 nF (Direct Readout, ±1 pF or <1% error, 0.1 pF resolution)
Inductance Range1 nH – 140 mH (0.1 nH resolution, <3% error)
Q Factor Range1–1000 (4-digit display, 0.1 Q resolution, <5% measurement error)
Dielectric Constant (εᵣ) Accuracy±0.1% (3-digit LCD readout)
Dissipation Factor (tan δ) Accuracy±0.01% (4-digit LCD readout)
Sample Thickness Range0.1 mm – 10 mm
Auto-NullingResidual inductance & lead inductance compensation
ComplianceGB/T 1693–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method (Q-factor based)
Frequency Range10 kHz – 100 MHz
Capacitance Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Accuracy±1 pF or <1%
Inductance Measurement Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Accuracy<3%
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Dielectric Constant (εᵣ) Accuracy±0.001 (0.1%)
Dissipation Factor (tan δ) Accuracy±0.0001 (0.01%)
Sample Thickness Range0.1 mm – 10 mm
Compliance StandardGB/T 1693–2007
DisplayLCD with real-time parameters (F, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ)
Tuning MechanismMotorized auto-search capacitance bridge (17–240 pF main capacitor, silver-plated monolithic construction)
ADC Resolution12-bit
Signal Source Stability3×10⁻⁵ ±1 digit (6-digit frequency precision)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Capacitance Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Accuracy±1 pF or <1%
Inductance Measurement Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Accuracy<3%
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Dielectric Constant (εᵣ) Accuracy±0.001 (0.1%)
Dissipation Factor (tan δ) Accuracy±0.0001 (0.01%)
Sample Thickness Compatibility0.1 mm – 10 mm
ComplianceGB/T 1693–2007
Auto-NullingResidual inductance & lead inductance compensation
Tuning Capacitor17–240 pF (silver-plated monolithic)
Capacitor SearchMotorized step-driven auto-tuning
DisplayMulti-parameter LCD (f, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN (Nanjing Dazhan Instrument Co., Ltd.)
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method (Q-factor based)
Frequency Range10 kHz – 100 MHz (DDS Digital Synthesis, 7000:1 coverage ratio)
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000 (auto/manual range, 4-digit resolution, 0.1 Q step)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH (0.1 nH resolution, <3% error)
Main Tuning Capacitance17–240 pF (silver-plated monolithic capacitor)
Capacitance Direct Measurement Range1 pF – 25 nF (±1 pF or <1% error, 0.1 pF resolution)
Automatic Capacitance SearchStepper-motor-driven
Residual & Lead Inductance CompensationYes (automated subtraction)
DisplayLCD showing F, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ, etc.
AD Sampling12-bit high-precision ADC
Q Pre-set Pass/Fail Threshold5–1000 with audible/visual alert
Operating ModeAuto-resonance sweep or manual tuning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method
Frequency Range10 kHz – 100 MHz
Q Factor Range1–1000
Q Resolution0.1 (4-digit)
Q Accuracy<5%
Inductance Range1 nH – 140 mH (0.1 nH resolution)
Capacitance Range1 pF – 25 nF (0.1 pF resolution)
Main Tuning Capacitor17–240 pF (silver-plated, ±1 pF or <1% error)
Signal Source Stability3×10⁻⁵ ±1 digit
ADC Resolution12-bit
Auto-Null CompensationResidual inductance & lead inductance
DisplayLCD with real-time F, L, C, Q, Lₜ, Cₜ, εᵣ, tan δ
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelDZ5001
Price RangeUSD 2,800 – 7,000
Measurement PrincipleResonant Cavity / Series/Parallel Resonance Method (Q-factor based)
Frequency Range10 kHz – 100 MHz (DDS Synthesized, 7000:1 Sweep Ratio)
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Capacitance Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Accuracy±1 pF or <1%
Inductance Measurement Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Accuracy<3%
Q Factor Range1–1000
Q Resolution0.1 (4-digit effective)
Q Measurement Error<5%
Dielectric Constant (εᵣ) Display Accuracy±0.001 (3-digit decimal)
Loss Tangent (tan δ) / Dissipation Factor Accuracy±0.0001 (4-digit decimal)
Sample Thickness Range0.1 mm – 10 mm
Residual Inductance CompensationAutomatic (integrated lead & fixture inductance nulling)
Compliance StandardGB/T 1693–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelDZ5001
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Capacitance Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Accuracy±1 pF or <1%
Inductance Measurement Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Accuracy<3%
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Dielectric Constant (εᵣ) Display Accuracy±0.001
Dissipation Factor (tan δ) Display Accuracy±0.0001
Sample Thickness Range0.1 mm – 10 mm
ComplianceGB/T 1693–2007
Auto-Null FunctionResidual inductance & lead inductance compensation
Tuning Capacitor17–240 pF (silver-plated monolithic)
Resonance SearchMotorized auto-scan
DisplayLCD showing F, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ, etc.
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNanjing Dazhan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelDZ5001
Price RangeUSD 2,800 – 7,000
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
ADC Resolution12-bit
Q Factor Range1–1000
Q Resolution0.1 (4-digit effective)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Tuning Capacitance17–240 pF (silver-plated monolithic construction)
Capacitance Direct Measurement Range1 pF – 25 nF
Capacitance Accuracy±1 pF or <1%
Capacitance Resolution0.1 pF
Automatic Resonance SearchYes (stepper motor-driven)
Displayed ParametersF, L, C, Q, Lt, Ct, εᵣ, Tn
Residual Inductance CompensationYes
Lead Inductance CompensationYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000
Q Resolution0.1 (4-digit effective)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Tuning Capacitance17–240 pF (silver-plated monolithic)
Capacitance Direct Measurement Range1 pF – 25 nF
Capacitance Accuracy±1 pF or <1%
Capacitance Resolution0.1 pF
Auto Capacitance SearchYes (stepper motor driven)
DisplayLCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc.
Residual Inductance CompensationYes
Data InterfaceRS-232/USB for PC connectivity
ComplianceDesigned per IEC 60250 and ASTM D150 guidelines for dielectric property measurement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDAZHAN
ModelDZ5001
Measurement PrincipleHigh-Frequency Resonance Method (Parallel-Plate Capacitor Configuration)
Frequency Range10 kHz – 100 MHz
Frequency Accuracy±3×10⁻⁵ (6-digit resolution)
Q Factor Range1–1000
Q Resolution0.1 (4-digit display)
Q Measurement Error<5%
Inductance Range1 nH – 140 mH
Inductance Resolution0.1 nH
Inductance Error<3%
Main Tuning Capacitance17–240 pF (silver-plated monolithic capacitor)
Capacitance Direct Measurement Range1 pF – 25 nF
Capacitance Resolution0.1 pF
Capacitance Error±1 pF or <1%
Automatic Capacitance SearchYes (stepper motor-driven)
Residual & Lead Inductance CompensationYes
DisplayLCD showing F, L, C, Q, Lt, Ct, εᵣ, tanδ, Tn
ComplianceGB/T 1693–2007, ASTM D150, GB 9622.9–1988 / SJ/T 11043–1996
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0