| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TFP External Cladding Fire Test System |
| Standards Compliance | DIN 4102-20, ONORM B3800-5, BS 8414-1 |
| Combustion Chamber Base | Stainless steel roller bed with gravel fill, non-return valve, ignition system, and flame detection sensor |
| Exhaust System | Radial exhaust fan with mass-flow control (0–200 L/min), stainless steel exhaust hood and collector |
| Cooling | Peltier cooler (down to −10 °C) |
| Gas Analysis | Siemens paramagnetic O₂ analyzer (16–21% v/v, resolution 0.001%), NDIR CO₂ analyzer (0–10% v/v) |
| Temperature Measurement | −100 °C to 1300 °C, resolution 0.1 K, cold-junction compensation |
| Pressure Differential Sensor | 0–20 Pa, accuracy ±1% |
| Propane Mass Flow Controller | 0–0.5 kg/min |
| Measurement Tube | Stainless steel, Ø600 mm |
| Control Unit | Integrated single-board computer with 10.1″ color touchscreen interface for real-time monitoring and automated reporting |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | SBI Single Burning Item Test System |
| Compliance | EN 13823, GB/T 20284, GB/T 20248 |
| Sample Configuration | Two perpendicular non-flooring building material specimens mounted on a trolley |
| Ignition Source | Sand-boxed J-type burner |
| Exhaust Duct | Ø(315 ± 5) mm |
| Mass Flow Controller Range | >0–2.1 g/s, accuracy better than ±1.5% of reading |
| Burner Switching Response Time | ≤12 s |
| Oxygen Analyzer | Paramagnetic, 16–21% (v/v), resolution 0.001% |
| CO₂ Analyzer | NDIR, 0–10% (v/v) |
| Smoke Measurement | White-light or laser-based optical density system |
| Cooling | Peltier-cooled gas conditioning unit |
| Data Acquisition | Integrated modular control and acquisition platform |
| Interface | High-resolution color touchscreen HMI |
| Gas Analysis | Siemens OEM analyzer with bidirectional communication and auto-calibration capability |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | HBK Horizontal Burning Chamber |
| Compliance Standards | ISO 3795, DIN 75200, FMVSS 302, GB 8410, CMVSS 302, FAR 25.853 |
| Sample Dimensions | 356 × 100 × ≤13 mm |
| Fuel | ≥95% purity propane |
| Gas Pressure | 4.0 bar |
| Chamber Dimensions (W×D×H) | 385 × 210 × 365 mm |
| Weight | 26 kg |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TBB Radiant Panel Test Apparatus |
| Standard Compliance | EN ISO 9239-1 |
| Chamber Dimensions (H×W×D) | 212 × 53 × 142 cm |
| Specimen Dimensions (H×W×D) | 2.2 × 32.5 × 114 cm |
| Radiant Heat Source Temperature Range | 300–1000 °C |
| Temperature Resolution | 0.1 K |
| Heat Flux Measurement Range (Schmidt-Boelte Type) | 0–20 kW/m² |
| Light Source | 10 W Halogen Spot Lamp, Color Temperature 2900 K |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | LOI Oxygen Index Analyzer |
| Compliance | ISO 4589-2, DIN 22117, ASTM D2863 |
| Dimensions (W × D × H) | 360 × 360 × 630 mm |
| Glass Column Dimensions (Ø × H) | 75 × 450 mm |
| Test Accuracy | ±0.1% O₂ |
| Weight | 8.2 kg |
| Oxygen Sensor Type | Paramagnetic |
| Display | Color High-Resolution Touchscreen |
| Sample Holders | Supported & Unsupported Configurations |
| Data Interface | USB & Ethernet |
| Automation | Fully Automated Calibration & Test Sequence |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TCC918 Cone Calorimeter |
| Cone Heater | 220 V, 5 kW, adjustable heat flux 0–100 kW/m² |
| Thermocouple Accuracy | ±0.5 °C, tolerance 0.004 |
| Specimen Holder | 100 × 100 × 50 mm (expandable for vertical drip testing) |
| Load Cell | 8.2 kg max capacity, resolution 0.01 g, linearity ±0.02 g |
| Heat Flux Meter | fully automated control, accuracy ±2%, repeatability ±0.5% |
| O₂ Analyzer | paramagnetic, 0–25% vol, accuracy 0.001%, noise & drift <100 ppm |
| CO₂ Analyzer | NDIR, 0–10% vol, accuracy 0.001% |
| CO Analyzer | NDIR, 0–1% vol, accuracy 0.001% |
| C-factor Range | 0.036–0.044, calibration deviation ≤5% |
| Peltier Cooling | down to −10 °C |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | KBT Cable Fire Testing System |
| Standards Compliance | EN 50399, IEC 60332-3, GB/T 31248, GB/T 18380.31, IEC 60332-3-10 |
| Chamber Dimensions (W × D × H) | 135 × 235 × 430 cm |
| Exhaust Opening (W × D) | 100 × 30 cm |
| Fume Hood Dimensions (H × W × D) | 100 × 150 × 100 cm |
| Temperature Measurement Range | −100 to 1300 °C, Resolution: 0.1 K |
| Mass Flow Controller Range | 0–1 L/min, Accuracy: ±0.3 L/min |
| Paramagnetic O₂ Analyzer | 16–21 % (v/v), Max. Resolution: 0.001 % |
| NDIR CO₂ Analyzer | 0–10 % (v/v) |
| Peltier Condenser | Min. Temp. −10 °C, Dryer-Free Operation |
| Gas Sampling Probes | High-Precision Bidirectional |
| Control System | Siemens Gas Analyzers with Auto-Calibration & Dual-Direction Data Exchange |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TSP Smoldering Test Apparatus |
| Compliance Standard | DIN EN 16733 |
| Sample Dimensions | 800 mm (L) × 300 mm (W) × ≤100 mm (T) |
| Sample Holder Material | Stainless Steel |
| Thermocouple Type | K-type NiCr–Ni armored |
| Ambient Operating Temperature | +20 ± 10 °C |
| Fire Suppression Plate Material | Calcium Silicate |
| Gas Control | Front-mounted main gas valve and pressure regulator |
| Flow Control | Adjustable flow restrictor and variable-area rotameter |
| Safety Features | Integrated flame-quenching plate with certified thermal inertia |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | KBK Flammability Test Chamber |
| Compliance | EN ISO 11925-2 |
| Sample Dimensions | 250 × 90 × ≤60 mm |
| Fuel | Propane (≥95% purity) |
| Gas Pressure | 4.0 bar |
| Airflow Velocity Accuracy | ±0.1 m/s |
| Operating Temperature | +23 ± 5 °C |
| Chamber Dimensions (W×D×H) | 700 × 400 × 980 mm |
| Construction Material | Corrosion-Resistant Stainless Steel |
| Viewing Windows | Dual Large-Sized Fire-Rated Glass Doors |
| Adjustable Sample Holder | Horizontal & Vertical Positioning |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | FRG Structural Adhesion Tester |
| Compliance | DIN EN 520 |
| Sample Dimensions (L × W × T) | 300 × 45 × 9.5 / 12.5 / 15.0 mm |
| Propane Purity | ≥95%, Operating Pressure: 4.0 bar |
| Device Dimensions (W × D × H) | 450 × 400 × 300 mm |
| Weight | 37 kg |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TNB Non-Combustibility Furnace |
| Compliance | ISO 1182, EN 13501-1, GB 8624 |
| Chamber Material | Stainless Steel |
| Viewing Mirror | 300 × 320 mm, 30° tilt |
| Thermocouple Type | Armored N- or K-type |
| Temperature Range | Up to 1300 °C |
| Resolution | 0.1 K with Cold-Junction Compensation |
| Integrated Control Unit | Single-board computer with 32 GB SSD |
| Data Interface | USB and Ethernet |
| Heating Control | Digital linear ramping with real-time monitoring |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | SBK Flammability Test Chamber for Toys |
| Compliance | EN 71-2 |
| Sample Dimensions (H × W) | 610 (310) × 100 mm |
| Sample Holder | Adjustable in Horizontal and Vertical Planes |
| Fuel | Propane (≥95% purity) |
| Gas Pressure | 4.0 bar |
| Operating Temperature | +23 ± 5 °C |
| Chamber Dimensions (W × D × H) | 70 × 70 × 121 cm |
| Construction | Corrosion-Resistant Stainless Steel |
| Viewing | Dual Large Fire-Rated Glass Doors |
| Gas Control | Front-Mounted Main Shut-Off Valve and Fine-Tuning Burner Control Valve |
| Pressure Monitoring | Integrated Pressure Gauge Regulator |
| Burner Positioning | Contaminant-Shielded Burner Displacement Mechanism |
| Application Scope | Textiles, Furnishings, Toy Accessories (e.g., Wigs, Facial Hair Simulants, Plush Trim) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TRDL Helium-Neon Laser Smoke Density Tester |
| Light Source | He–Ne laser (632.8 nm) |
| Optical Path Length | 10 m (unobstructed) |
| Calibration Filters | Neutral density filters with OD 0.3 and 0.8 |
| Compliance | ISO 5660-2, ASTM E662, NFPA 265, UL 94, IEC 60695-2-2 |
| Interface | USB + RS232 |
| Control System | Integrated single-board computer with Windows OS, high-resolution color touchscreen, TRDL proprietary software |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | UL94 Vertical/Horizontal Flame Chamber |
| Standards Compliance | UL 94 (5th Ed.), IEC/EN 60695-11-10, -11-20, -11-3, -11-4, ISO 9773 |
| Sample Dimensions (Strip) | 125.0 ± 5.0 mm × 13.0 ± 0.5 mm |
| Sample Dimensions (Sheet) | ≥150.0 ± 5.0 mm × ≥150.0 ± 5.0 mm |
| Burner Power | 50 W / 500 W |
| Burner Tilt Angles | 0°, 20°, 45° |
| Touchscreen Interface | 10" High-Resolution Capacitive Display |
| Enclosure Material | Sandblasted Stainless Steel (AISI 304) |
| Integrated Control Unit | Embedded Industrial PC with 32 GB SSD Storage |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TRDA Optical Smoke Density Measurement System |
| Light Source | 10 W halogen lamp, color temperature 2900 K |
| Beam Diameter | 22–500 mm |
| Photometric Linearity | < ±1.5% |
| Compliance | DIN 50055 |
| Control Interface | USB & RS232 |
| Integrated Computing | Single-board computer with Windows OS, TRDA software, high-resolution color touchscreen |
| Accessories Support | Compatibility with single-burner and bundled-cable fire testing configurations |
| Software Licensing | TRDA software — exclusive licensed implementation |