Empowering Scientific Discovery

NETZSCH Thermal Analysis GmbH

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNETZSCH
OriginGermany
ModelDSC 300 Caliris Classic
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range−170 °C to 600 °C
Heating/Cooling Rate0.001–100 K/min
Temperature Accuracy±0.1 K (intrinsic)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNetzsch
OriginGermany
ModelDSC 300 Caliris® Select-P
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range–170 to 600 °C
Heating/Cooling Rate0 to 500 K/min
ComplianceGLP/GMP, FDA 21 CFR Part 11 (software-enabled), ISO 11357, ASTM E794, ASTM E1356
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNetzsch
OriginGermany
ModelDSC 204 F1 Phoenix
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range–180 °C to 700 °C
Temperature Accuracy±0.1 K
Heating/Cooling Rate0 to 200 K/min
Sensor Optionsτ-type (time constant 0.6 s), μ-type (high-sensitivity)
Cooling OptionsLiquid nitrogen (LN₂), mechanical refrigeration (–85 °C to 600 °C), compressed air, cooling cup
Sample CapacityMulti-sample capability (optional 64-position ASC auto-sampler)
Atmosphere ControlIntegrated mass flow controller, gas-tight furnace design compatible with FTIR/MS coupling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNetzsch
OriginGermany
Instrument TypeDSC
Temperature Range−170 °C to 600 °C
Temperature Accuracy±0.1 K
Heating/Cooling Rate0 to 500 °C/min
Detection Limit0.1 μW
Atmosphere ControlDynamic or static inert, reducing, or oxidizing (automated gas switching)
Cooling OptionsCompressed air, mechanical refrigeration, liquid nitrogen (dual-cooling system optional, software-switchable)
Optional AccessoriesPhoto-DSC module, ASC automatic sample changer (20 positions), TMDSC upgrade
Software FeaturesIntelligent Mode, Expert Mode, Auto-Calibration, Auto-Analysis, Pattern Recognition, Tau-R® advanced thermal lag correction, DSC spectral database and search engine
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNetzsch
OriginGermany
ModelDSC 404 F3 Pegasus
Temperature Range−150 to 2000 °C
Temperature Accuracy±0.1 K
Heating/Cooling Rate0–50 K/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNETZSCH
OriginGermany
ModelDSC 3500 Sirius
Temperature Range−170 °C to 600 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0–100 K/min
Sample Capacity (with ASC)Up to 20 positions (samples + references)
Instrument TypeDifferential Scanning Calorimeter
炉 Body MaterialSilver-based furnace block
Sensor ArchitectureMonolithic sensor design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNetzsch
OriginGermany
ModelDSC 204 HP Phoenix
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range–150 °C to 600 °C (under vacuum to 15 MPa)
Temperature Accuracy±0.1 K
Heating/Cooling Rate0–100 K/min
Pressure Range0–15 MPa (0–150 bar)
Atmosphere CompatibilityStatic or dynamic O₂, N₂, Ar, He, H₂, CO₂, CH₄, and other process gases
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNETZSCH
OriginGermany
ModelDSC 300 Caliris Supreme-H
Instrument TypeDifferential Scanning Calorimeter
Temperature Range−180 °C to 750 °C
Heating/Cooling Rate0 to 200 K/min
Module ArchitectureInterchangeable Multi-Module Platform
ComplianceGLP, GMP, FDA 21 CFR Part 11 (with optional software package)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNetzsch
OriginGermany
ModelDSC 404 F1 Pegasus
Temperature Range−150 to 2000 °C
Temperature Accuracy±0.1 K
Heating/Cooling Rate0–50 K/min
Sensor TypesReplaceable DSC (−150 to 1650 °C) and DTA (up to 2000 °C)
Vacuum CapabilityHigh-vacuum sealed system
Gas ControlIntegrated stainless-steel gas lines with metal-encapsulated mass flow controllers (MFCs)
Optional AutomationStepper-motor-driven dual-furnace configuration and 20-position auto-sampler
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNetzsch
OriginGermany
Instrument TypeDSC
Temperature Range−170 to 650 °C
Heating/Cooling Rate0–100 K/min
Module ConfigurationSensor + Furnace Assembly (S-Module)
ComplianceGLP/GMP, FDA 21 CFR Part 11 (with optional software package)
Key Software FeaturesBeFlat®, Tau-R Correction, TM-DSC (optional), Automatic Baseline Subtraction, Crystallinity Calculation, Cp Measurement
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0