- All
- Favorite
- Popular
- Most rated
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Classic |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.1 K (intrinsic) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris® Select-P |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –170 to 600 °C |
| Heating/Cooling Rate | 0 to 500 K/min |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (software-enabled), ISO 11357, ASTM E794, ASTM E1356 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 F1 Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –180 °C to 700 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 200 K/min |
| Sensor Options | τ-type (time constant 0.6 s), μ-type (high-sensitivity) |
| Cooling Options | Liquid nitrogen (LN₂), mechanical refrigeration (–85 °C to 600 °C), compressed air, cooling cup |
| Sample Capacity | Multi-sample capability (optional 64-position ASC auto-sampler) |
| Atmosphere Control | Integrated mass flow controller, gas-tight furnace design compatible with FTIR/MS coupling |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 500 °C/min |
| Detection Limit | 0.1 μW |
| Atmosphere Control | Dynamic or static inert, reducing, or oxidizing (automated gas switching) |
| Cooling Options | Compressed air, mechanical refrigeration, liquid nitrogen (dual-cooling system optional, software-switchable) |
| Optional Accessories | Photo-DSC module, ASC automatic sample changer (20 positions), TMDSC upgrade |
| Software Features | Intelligent Mode, Expert Mode, Auto-Calibration, Auto-Analysis, Pattern Recognition, Tau-R® advanced thermal lag correction, DSC spectral database and search engine |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F3 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 3500 Sirius |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Sample Capacity (with ASC) | Up to 20 positions (samples + references) |
| Instrument Type | Differential Scanning Calorimeter |
| 炉 Body Material | Silver-based furnace block |
| Sensor Architecture | Monolithic sensor design |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 HP Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –150 °C to 600 °C (under vacuum to 15 MPa) |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–100 K/min |
| Pressure Range | 0–15 MPa (0–150 bar) |
| Atmosphere Compatibility | Static or dynamic O₂, N₂, Ar, He, H₂, CO₂, CH₄, and other process gases |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Supreme-H |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −180 °C to 750 °C |
| Heating/Cooling Rate | 0 to 200 K/min |
| Module Architecture | Interchangeable Multi-Module Platform |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software package) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F1 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Sensor Types | Replaceable DSC (−150 to 1650 °C) and DTA (up to 2000 °C) |
| Vacuum Capability | High-vacuum sealed system |
| Gas Control | Integrated stainless-steel gas lines with metal-encapsulated mass flow controllers (MFCs) |
| Optional Automation | Stepper-motor-driven dual-furnace configuration and 20-position auto-sampler |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 to 650 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Module Configuration | Sensor + Furnace Assembly (S-Module) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (with optional software package) |
| Key Software Features | BeFlat®, Tau-R Correction, TM-DSC (optional), Automatic Baseline Subtraction, Crystallinity Calculation, Cp Measurement |