Empowering Scientific Discovery

Onkel Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 6300
Ozone Measurement PrincipleNon-dispersive UV absorption
Ozone Range0–100 / 1,000 / 10,000 pphm
Response Time5 s
Detection Limit1 pphm
Accuracy±0.2% of reading
Repeatability±0.2% of full scale
Temperature Control Range15–70 °C (RT = 23 °C)
Temp. Accuracy±5 K
Temp. Ramp Rate0.4 K/min
Humidity Range30–80% RH
Humidity Accuracy–1 to +4% RH
Humidity Stabilization Time to 95%≤20 min
Ozone Control Range20–200 pphm
Ozone Control Accuracy±1 pphm
Ozone Stabilization Time to 95%10 min
Airflow Velocity in Chamber600 mm/s
Air Exchange Rate400 L/h
Chamber Internal Dimensions680 × 650 × 400 mm
External Dimensions950 × 870 × 610 mm
Power Supply230 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM6200-T-CL
Chamber Volume230 L
Internal Dimensions (H×W×L)50 × 68 × 68 cm
Total Dimensions (H×W×L)181 (+43) × 99 × 120 (+10) cm
Weight400 kg
Power Supply230/120 VAC, 50/60 Hz
Ozone Concentration Range0–1000 pphmv
Airflow Velocity (in chamber)8–16 mm/s (longitudinal, laminar flow)
Reynolds Number (Re)300–1000
Loading FactorG = 12 s/m (per ISO 1431-1)
Certified Ozone AnalyzerMP60602
Ozone GeneratorMaintenance-Free Type
Control SystemSiemens SIMATIC S7-300 PLC with 15″ Touchscreen HMI
Data InterfaceRS232, USB
Safety FeaturesCatalytic ozone destruct, activated carbon filter, turbofan recirculation, interlocked safety door, audible/visual alarms
ComplianceASTM D1149, ISO 1431-1, DIN ISO 1431-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANSEROS
OriginGermany
ModelSIM 8000
Chamber Volume8000 L
Temperature Range15–70 °C (RT = 23 °C)
Humidity Range30–80 % RH
Ozone Concentration Control20–200 pphm
Ozone Measurement PrincipleNon-dispersive UV Absorption
Ozone Detection Limit1 pphm
Response Time5 s
Accuracy±1 pphm (ozone), ±5 K (temperature), −1 to +4 % RH (humidity)
Airflow Velocity in Test Zone600 mm/s
Air Exchange Rate400 L/h
Power Supply230 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 6010T
Temperature Range26–60 °C (standard), 15–70 °C (extended)
Humidity Range30–80 % RH
Ozone Concentration Control Range20–200 pphm
Ozone Measurement PrincipleNon-dispersive UV absorption
Ozone Measurement Range0–100 / 1,000 / 10,000 pphm
Detection Limit1 pphm
Response Time5 s
Accuracy±0.2 % of reading (ozone sensor)
Airflow Velocity in Chamber600 mm/s
Air Exchange Rate400 L/h
Recovery Time to 95 % Set Ozone Level≤10 min
Recovery Rate0.4 K/min
Temperature CompensationAutomatic, 0–60 °C ±1 °C
Pressure CompensationAutomatic, 600–1500 mbar ±2 mbar
Zero DriftAuto-zeroing cycle every 2 s
Span DriftNone (single-beam optical design)
Power Supply230 V / 50 Hz
External Dimensions950 × 870 × 610 mm
Usable Internal Volume680 × 650 × 400 mm
Generator/Controller/Detector Cabinet1600 × 550 × 600 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANSEROS
OriginGermany
ModelSIM6300-T-CL
ComplianceASTM D1149, ISO 1431-1, DIN ISO 1431-1
Ozone GenerationMaintenance-free corona discharge generator
Ozone MonitoringCertified ozone analyzer (MP series) with closed-loop feedback control
Control SystemProgrammable logic controller (PLC) with interrupt-resume functionality for long-term durability testing
Air CirculationRecirculating turbojet system integrated with catalytic ozone destruct unit and activated carbon filter
Sample MountingDual-mode fixture—static test racks and dynamic rotating sample disc (4-position V-groove clamping)
Data InterfaceRS232 serial port for real-time logging to ANSEROS on-board monitoring software
Chamber ConfigurationClimate-controlled enclosure with temperature stabilization (ambient to +70 °C, ±0.5 °C uniformity)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANSEROS
OriginGermany
ModelSIM-6300
Internal Dimensions680 × 680 × 500 mm
External Dimensions1610 × 1500 × 1000 mm
Gas Flow Velocity8–700 mm/s
Air Exchange Rate50–500 L/min
Air Replacement Rate1–2000 dm³/h (33 L/min)
Temperature RangeRT to 70 °C ±0.5 °C
Humidity Range30–90 %RH (±1/+4 %RH)
Ozone Measurement PrincipleSingle-beam NDUV Photometry
Ozone Concentration Range0–1999 mg O₃/Nm³ or 0–1000 ppmv
Sensitivity0.001 ppmv
Accuracy<1 % SCE
Linearity98 % SCE
Ozone Generation MethodCorona Discharge (COM-ADM)
Ozone Output Capacity10–2000 mg/h
Ozone Flow Rate100–2000 NL/h
Power Consumption3000 W
Voltage230 V, 10 A
Weight250 kg
Compliant StandardsASTM D1149, ASTM D2802, ASTM D4246-02, ASTM D4575, ASTM D470, ASTM D518, BS 903 A43, DIN 53509-2-1, FORD FLTM BP101-01, GB/T 11206-2009, GB/T 13642-1992, GB/T 2951.1–2951.10-1997, GB/T 2951.21-2008, GB/T 7762-2003, HG/T 2716-2008, HG/T 2869-1997, ISO 1431-1 & -3, MIL-STD-1344A, NGF 37112, SAE J1401, SIS 16 12 10
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 6050-T
Temperature Range15–70 °C (RT = 23 °C)
Humidity Range30–80 % RH
Ozone Concentration Control Range20–200 pphm
Ozone Measurement PrincipleNon-dispersive UV absorption
Ozone Detection Limit1 pphm
Response Time5 s
Temperature Accuracy±5 K
Humidity Accuracy−1 to +4 % RH
Airflow Velocity in Test Chamber600 mm/s
Air Exchange Rate400 L/h
Chamber Internal Dimensions425 × 460 × 270 mm
External Dimensions670 × 620 × 510 mm
Power Supply230 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 7500
Temperature Range26–60 °C (RT = 23 °C)
Humidity Range30–80 % RH
Ozone Concentration Control Range20–200 pphm
Ozone Measurement PrincipleNon-dispersive ultraviolet (NDUV) absorption
Ozone Detection Limit1 pphm
Response Time5 s
Temperature Accuracy±5 K
Humidity Accuracy−1 to +4 % RH
Airflow Velocity600 mm/s
Air Exchange Rate400 L/h
Chamber Internal Dimensions425 × 460 × 270 mm (standard)
Power Supply230 V / 50 Hz