| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6300 |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Range | 0–100 / 1,000 / 10,000 pphm |
| Response Time | 5 s |
| Detection Limit | 1 pphm |
| Accuracy | ±0.2% of reading |
| Repeatability | ±0.2% of full scale |
| Temperature Control Range | 15–70 °C (RT = 23 °C) |
| Temp. Accuracy | ±5 K |
| Temp. Ramp Rate | 0.4 K/min |
| Humidity Range | 30–80% RH |
| Humidity Accuracy | –1 to +4% RH |
| Humidity Stabilization Time to 95% | ≤20 min |
| Ozone Control Range | 20–200 pphm |
| Ozone Control Accuracy | ±1 pphm |
| Ozone Stabilization Time to 95% | 10 min |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 680 × 650 × 400 mm |
| External Dimensions | 950 × 870 × 610 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM6200-T-CL |
| Chamber Volume | 230 L |
| Internal Dimensions (H×W×L) | 50 × 68 × 68 cm |
| Total Dimensions (H×W×L) | 181 (+43) × 99 × 120 (+10) cm |
| Weight | 400 kg |
| Power Supply | 230/120 VAC, 50/60 Hz |
| Ozone Concentration Range | 0–1000 pphmv |
| Airflow Velocity (in chamber) | 8–16 mm/s (longitudinal, laminar flow) |
| Reynolds Number (Re) | 300–1000 |
| Loading Factor | G = 12 s/m (per ISO 1431-1) |
| Certified Ozone Analyzer | MP60602 |
| Ozone Generator | Maintenance-Free Type |
| Control System | Siemens SIMATIC S7-300 PLC with 15″ Touchscreen HMI |
| Data Interface | RS232, USB |
| Safety Features | Catalytic ozone destruct, activated carbon filter, turbofan recirculation, interlocked safety door, audible/visual alarms |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM 8000 |
| Chamber Volume | 8000 L |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV Absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±1 pphm (ozone), ±5 K (temperature), −1 to +4 % RH (humidity) |
| Airflow Velocity in Test Zone | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6010T |
| Temperature Range | 26–60 °C (standard), 15–70 °C (extended) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Measurement Range | 0–100 / 1,000 / 10,000 pphm |
| Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±0.2 % of reading (ozone sensor) |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Recovery Time to 95 % Set Ozone Level | ≤10 min |
| Recovery Rate | 0.4 K/min |
| Temperature Compensation | Automatic, 0–60 °C ±1 °C |
| Pressure Compensation | Automatic, 600–1500 mbar ±2 mbar |
| Zero Drift | Auto-zeroing cycle every 2 s |
| Span Drift | None (single-beam optical design) |
| Power Supply | 230 V / 50 Hz |
| External Dimensions | 950 × 870 × 610 mm |
| Usable Internal Volume | 680 × 650 × 400 mm |
| Generator/Controller/Detector Cabinet | 1600 × 550 × 600 mm |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM6300-T-CL |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Ozone Generation | Maintenance-free corona discharge generator |
| Ozone Monitoring | Certified ozone analyzer (MP series) with closed-loop feedback control |
| Control System | Programmable logic controller (PLC) with interrupt-resume functionality for long-term durability testing |
| Air Circulation | Recirculating turbojet system integrated with catalytic ozone destruct unit and activated carbon filter |
| Sample Mounting | Dual-mode fixture—static test racks and dynamic rotating sample disc (4-position V-groove clamping) |
| Data Interface | RS232 serial port for real-time logging to ANSEROS on-board monitoring software |
| Chamber Configuration | Climate-controlled enclosure with temperature stabilization (ambient to +70 °C, ±0.5 °C uniformity) |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM-6300 |
| Internal Dimensions | 680 × 680 × 500 mm |
| External Dimensions | 1610 × 1500 × 1000 mm |
| Gas Flow Velocity | 8–700 mm/s |
| Air Exchange Rate | 50–500 L/min |
| Air Replacement Rate | 1–2000 dm³/h (33 L/min) |
| Temperature Range | RT to 70 °C ±0.5 °C |
| Humidity Range | 30–90 %RH (±1/+4 %RH) |
| Ozone Measurement Principle | Single-beam NDUV Photometry |
| Ozone Concentration Range | 0–1999 mg O₃/Nm³ or 0–1000 ppmv |
| Sensitivity | 0.001 ppmv |
| Accuracy | <1 % SCE |
| Linearity | 98 % SCE |
| Ozone Generation Method | Corona Discharge (COM-ADM) |
| Ozone Output Capacity | 10–2000 mg/h |
| Ozone Flow Rate | 100–2000 NL/h |
| Power Consumption | 3000 W |
| Voltage | 230 V, 10 A |
| Weight | 250 kg |
| Compliant Standards | ASTM D1149, ASTM D2802, ASTM D4246-02, ASTM D4575, ASTM D470, ASTM D518, BS 903 A43, DIN 53509-2-1, FORD FLTM BP101-01, GB/T 11206-2009, GB/T 13642-1992, GB/T 2951.1–2951.10-1997, GB/T 2951.21-2008, GB/T 7762-2003, HG/T 2716-2008, HG/T 2869-1997, ISO 1431-1 & -3, MIL-STD-1344A, NGF 37112, SAE J1401, SIS 16 12 10 |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6050-T |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity in Test Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm |
| External Dimensions | 670 × 620 × 510 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 7500 |
| Temperature Range | 26–60 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive ultraviolet (NDUV) absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm (standard) |
| Power Supply | 230 V / 50 Hz |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Xenon Lamp Power | 1800 W |
| Lamp Cooling | Air-cooled |
| Lamp Lifetime | ~1500 hours |
| Filter Options | Daylight-F / Daylight-Q / Daylight-B/B / Window-Q / Window-B/SL / Window-SF-5 / Window-IR / Extended UV-Q/B |
| Sample Mounting | Horizontal flat tray |
| Chamber Type | Benchtop |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUV (Imported from USA) |
| Quotation | Upon Request |
| Illuminant Temperature Range (°C) | Configurable per test standard |
| Black Panel Temperature Range (°C) | 35–80 °C (typical operating range) |
| UV Wavelength Range (nm) | 295–400 nm (selectable via lamp type: UVA-340 or UVB-313) |
| Chamber Dimensions (L×W×H) | 1100 × 500 × 420 mm (standard QUV se model) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HDS |
| Lamp Type | Air-Cooled Xenon Arc Lamp (3-lamp configuration) |
| Spectral Range | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, or TUV 300–400 nm) |
| Black Panel Temperature Range | 42–120 °C |
| Chamber Air Temperature Range | Ambient to 90 °C (with optional refrigerated cooling unit) |
| Relative Humidity Control | 10–95% RH (standard) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Sample Capacity | Up to 51 specimens (51 mm × 102 mm) |
| Dual Spray System | Standard (deionized water + secondary solution, e.g., acid rain or detergent) |
| Calibration | AUTOCAL® automated calibration system |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Interface | Touchscreen controller with built-in Ethernet, self-diagnostic alerts, GLP/GMP-ready audit trail logging |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/SE |
| Chamber Dimensions (L×W×H) | 114 × 50 × 40 cm |
| Light Source Options | UVA-340 or UVB-313 fluorescent lamps |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Black Panel Temperature Range | 35–80 °C |
| Condensation Temperature Range | 40–60 °C |
| Illumination Temperature Range | 45–80 °C |
| Sample Capacity | 48 specimens (75 × 150 mm) |
| Power Supply | 120 V / 60 Hz, 16 A or 230 V / 50–60 Hz, 8 A |
| Water Consumption | 8 L/day (condensation mode) |
| Lamp Life (avg.) | 5000 h |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN B02-S |
| Xenon Lamp Power | 1800 W |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM 16 (Option 2 & 3), AATCC TM 169, M&S C9/C9A |
| Sample Capacity | 31 AATCC pre-cut specimens (1882 cm² total exposure area) |
| Lamp Type | Air-cooled xenon arc lamp |
| Lamp Life | ~1500 hours |
| Temperature Control | Blackboard temperature (35–103 °C), chamber air temperature |
| Humidity Control | Relative humidity (RH) with optional water spray |
| Filter System | Dual-filter assembly (outer borosilicate tube + inner 7-element filter set) for Window-IR (ISO/M&S) or Window-B/SL (AATCC) spectral profiles |