| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-008TNIR |
| Sensor Type | InGaAs |
| Spectral Range | 900–1700 nm |
| Resolution | 320(H) × 256(V) |
| Pixel Size | 30 µm × 30 µm |
| Active Imaging Area | 9.6 mm × 7.68 mm |
| Shutter Type | Global Shutter |
| Scan Mode | Progressive Scan |
| Interface | USB 2.0 |
| Frame Rate | 90 fps |
| A/D Resolution | 12-bit |
| Cooling | Uncooled (TEC optional on higher models) |
| Lens Mount | C-Mount |
| Power Supply | DC 12 V |
| Operating Temperature | 0–35 °C |
| Dimensions | 71.6(W) × 61.5(H) × 125(D) mm |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-031TNIR |
| Sensor Type | InGaAs |
| Spectral Range | 900–1700 nm |
| Resolution | 640(H) × 512(V) |
| Pixel Size | 25 µm × 25 µm |
| Active Imaging Area | 16.0 mm × 12.8 mm |
| Shutter Type | Global Shutter |
| Scan Mode | Progressive Scan |
| Interface | USB 2.0 |
| A/D Resolution | 12-bit |
| Frame Rate | 27.4 fps |
| Exposure Time | 5.4 µs – 4.408 s |
| Detectivity | ≥5 × 10¹² Jones |
| Full Well Capacity | High Gain: 118 ke⁻, Low Gain: 1.9 Me⁻ |
| Cooling | Integrated TEC (Thermoelectric Cooler) |
| Lens Mount | C-Mount |
| Power Supply | DC 12 V |
| Power Consumption | <20 W |
| Operating Temperature | 0–35 °C |
| Dimensions | 71.6 × 61.5 × 125 mm |
| Weight | ~400 g |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-131TNIR |
| Spectral Range | 900–1700 nm |
| Sensor Type | InGaAs (Indium Gallium Arsenide) |
| Interface | GigE Vision or USB3 Vision (configurable) |
| Resolution | 640 × 512 pixels |
| Pixel Size | 15 µm |
| Cooling | Thermoelectric (TE) stabilized |
| Dynamic Range | ≥60 dB (typ.) |
| Frame Rate | Up to 120 fps at full resolution |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-2020UV-USB3 |
| Sensor Type | CMOS (GSENSE2020BSI back-illuminated) |
| Spectral Response | 200–1100 nm |
| Resolution | 2048 × 2048 pixels |
| Pixel Size | 6.5 µm × 6.5 µm |
| Imaging Area | 13.3 mm × 13.3 mm |
| Shutter Mode | Rolling shutter with global reset capability |
| Frame Rate | 23 fps |
| Exposure Time | 11.2 µs – 1 s |
| A/D Resolution | 11/12 bits |
| Output Bit Depth | 12-bit |
| Interface | USB 3.0 |
| Lens Mount | C-mount |
| Power Supply | DC 12 V |
| Power Consumption | ~6 W |
| Operating Temperature | 0–35 °C |
| Dimensions (W×H×D) | 71.6 × 61.5 × 51.5 mm |
| Weight | ~240 g |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-487UV |
| Sensor Type | CMOS |
| Resolution | 2848 × 2848 |
| Pixel Size | 2.74 µm |
| Spectral Range | 200 nm – 1000 nm |
| Frame Rate | 38 fps |
| Interface | USB 3.0 |
| Shutter Mode | Global Shutter |
| ADC Resolution | 12 bit |
| Exposure Time | 0.1 ms – 26 ms |
| Lens Mount | C-Mount |
| Power Supply | 5 VDC |
| Operating Temperature | 0 °C – +35 °C |
| Dimensions (W×H×L) | 50 mm × 47 mm × 42.7 mm |
| Weight | 130 g |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-640P2-THERMO |
| Spectral Range | 8–14 µm |
| Resolution | 640 × 480 pixels |
| Type | Cooled or Uncooled Microbolometer (Inferred from Class & Spec) |
| Compliance | CE, RoHS, JIS C 1609-1 (Thermal Imaging Equipment Standard) |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-9701UV |
| Sensor Type | CMOS |
| Resolution | 1280 × 1024 |
| Pixel Size | 9.76 µm |
| Spectral Range | 200 nm – 1000 nm |
| Shutter Mode | Rolling Shutter |
| Frame Rate | 30 fps |
| ADC Resolution | 12 bit |
| Exposure Time | 37 µs – 2 s |
| Lens Mount | C-Mount |
| Interface | USB 3.0 |
| Power Supply | 5 VDC |
| Operating Temperature | 0 °C – +35 °C |
| Dimensions (W×H×L) | 50 mm × 47 mm × 42.7 mm |
| Weight | 110 g |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-991SWIR-TEC |
| Spectral Range | 400–1700 nm |
| Sensor Type | InGaAs (Indium Gallium Arsenide) |
| Cooling | Thermoelectrically Cooled (TEC) |
| Application Domain | SWIR Imaging, Laser Beam Profiling, Optical Metrology, Semiconductor Inspection |
| Brand | AS ONE |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Manufacturer |
| Country of Origin | China (Domestic) |
| Model No. | 1-5818-01 |
| Sensor Type | Silicon Photodiode |
| Display | 3.5-digit LCD with backlight |
| Accuracy | ±(5% rdg + 10 digits) |
| Sampling Rate | 2.5 samples/sec |
| Units | Lux (lx) and Foot-candles (fc), switchable via single button |
| Data Hold Function | Yes |
| Peak Hold Function | Yes |
| Sensor Mounting | Integrated fixing pin for secure sensor-to-body attachment |
| Power Supply | Not specified in source data |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AS3 |
| Price | Upon Request |
| Operating Pressure | Up to 20 bar |
| Sensor Max Temp | 90°C (110°C with air cooling) |
| Hazardous Area Options | ATEX Zone 1 & Zone 2 / UL Class I Div 1 |
| Sensor Length | ~300 mm (custom lengths available) |
| Measurement Range | 0–5 NTU to 0–5,000 NTU |
| Accuracy | ±1% of reading |
| Transducer Frequencies | 5 MHz and 15 MHz |
| Enclosure Rating | NEMA 4X / IP65 |
| Process Integration | Ball-valve-mounted insertion probe |
| Compatibility | AT3 interface |
| Brand | Asphericon |
|---|---|
| Origin | Germany |
| Model | ALL12-25-P-U |
| Numerical Aperture (NA) | 0.25 |
| Wavelength Optimization | 780 nm |
| Substrate Material | N-BK7 |
| Diameter | 12.5 mm |
| Effective Focal Length Tolerance | ≤ ±0.1 % |
| Surface Form Error (RMSi) | ≤ 0.1 µm |
| Surface Quality | 60–40 scratch-dig |
| Clear Aperture | ≥ 90 % |
| Coating Options | Standard AR Coatings A (400–600 nm), B (600–1050 nm), C (1000–1600 nm) |
| Laser Induced Damage Threshold (LIDT) | 12 J/cm² @ 100 Hz, 6 ns, 532 nm |
| Mounting | Unmounted (U) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 1T |
| Measurement Range | nD 1.3000–1.7000 / Brix 0.0–95.0% |
| Resolution | 0.001 (nD) / 0.5% (Brix) |
| Accuracy | ±0.0002 (nD) / ±0.1% (Brix) |
| Temperature Range | 0.0–50.0°C (Resolution: 0.1°C, Accuracy: ±0.2°C) |
| Light Source | 8 V, 0.15 A tungsten lamp |
| Power Supply | 100–240 VAC, 50/60 Hz, 6 VA |
| Dimensions & Weight | 13 × 18 × 23 cm, 3.4 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 60-C5 |
| Temperature Range | 10–60°C (water) |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.2°C |
| Bath Capacity | 1.0 L |
| Power Consumption | 250 VA |
| Input Voltage | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 20.4 × 33.6 × 28.9 cm |
| Weight | 9.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | ATAGO 60-C5 |
| Product Type | Benchtop Refractometer Accessory |
| Temperature Control | Yes |
| Digital Display | Yes |
| Temperature Range | 10–60°C (water) |
| Temperature Accuracy | ±0.2°C |
| Resolution | 0.1°C |
| Tank Capacity | 1.0 L |
| Power Input | AC 100–240 V, 50/60 Hz |
| Power Consumption | 250 VA |
| Dimensions (W×D×H) | 20.4 × 33.6 × 28.9 cm |
| Weight | 9.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-780 |
| Measurement Range | 0.0–78.0% Brix |
| Resolution | 0.1% Brix |
| Accuracy | ±0.2% Brix |
| Temperature Compensation | Automatic, 5–60 °C |
| Prism Material | Sapphire |
| Wetted Parts | SUS316 Stainless Steel |
| Output Interfaces | RS-232C, 4–20 mA analog (DC) |
| Power Supply | DC 24 V |
| Compliance | Designed for continuous industrial process monitoring in food, beverage, and chemical manufacturing environments |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α-SW |
| Measurement Range | 0.0–28.0% (ATC) |
| Accuracy | ±0.1% (salinity), ±1°C/°F (temperature) |
| Resolution | 0.01% (≤9.99%), 0.1% (≥10.0%) |
| Temperature Compensation Range | 5–100°C |
| Output | DC 4–20 mA, RS-232C |
| Light Source | LED (approx. 589 nm, D-line equivalent) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L Stainless Steel |
| IP Rating | IP67 |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Measurement Interval | ~1 s (configurable to 5 presets) |
| Environmental Operating Temp. | 5–40°C |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-ISα |
| Type | In-Line Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | Brix 0.0–80.0% |
| Refractive Index Accuracy | ±0.0002 |
| Brix Accuracy | ±0.1% |
| Temperature Range | −15 to 160 °C |
| Resolution | RI 0.00001, Brix 0.01% or 0.1%, Temp 0.1 °C |
| ATC Range | 5–100 °C |
| Output | 4–20 mA DC or RS-232C |
| Power Supply | 24 V DC |
| Explosion Protection | Ex ia IIB T3 Ga TA |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1 |
| Measurement Range | 1.3000–1.7100 (nD) / 0.0–95.0% Brix |
| Resolution | 0.0001 (nD) / 0.1% Brix |
| Accuracy | ±0.0002 (nD) / ±0.1% Brix |
| Automatic Temperature Compensation | 5–50°C |
| Temperature Measurement Range | 5–50°C (0.1°C resolution) |
| Power Supply | 100–240 VAC, 50/60 Hz, 10 VA |
| Dimensions & Weight | 13 × 29 × 31 cm, 6.0 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DR-A1 |
| Pricing | Available Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-Plus |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0.0–100.0% Brix (or refractive index equivalent) |
| Accuracy | ±0.1% Brix |
| Compliance | ISO 21745, ASTM D1218, JIS K0061 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4/1550(A) |
| Type | Benchtop Refractometer |
| Digital Display | Yes |
| Temperature Control | None |
| Refractive Index Range | 1.5167–1.9166 (at 450 nm) |
| Accuracy | ±0.0002 RI (at 589 nm) |
| Wavelength Range | 450–1550 nm |
| Resolution | 0.0001 RI / 0.1 Abbe Number |
| Operating Temperature | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (Main Unit) | 13 × 29 × 31 cm |
| Weight (Main Unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | ES-421 |
| Measurement Range | 0.00–10.0% (g/100g) |
| Accuracy | ±0.05% (0.00–0.99%), ±5% relative (1.00–10.0%) |
| Resolution | 0.01% (0.00–0.99%), 0.1% (3.0–10.0%) |
| Temperature Compensation | Automatic (ATC), 10–40°C |
| Power Supply | 9V alkaline battery (006P) |
| IP Rating | IP64 |
| Dimensions & Weight | 17 × 9 × 4 cm, 220 g (instrument only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | MASTER-53S |
| Product Type | Handheld Analog Refractometer |
| Measurement Range | 0.0–53.0% Brix |
| Resolution | 0.2% Brix |
| Accuracy | ±0.2% Brix at 20°C |
| Temperature Compensation | Automatic (ATC) |
| Dimensions | 3.2 × 3.4 × 16.8 cm |
| Weight | 130 g |
| Optical Scale Type | Analog (non-digital), Visual Reading via Eyepiece |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | MASTER-M |
| Measurement Range | Brix 0.0–32.0% |
| Scale Division | 0.20% |
| Maximum Operating Temperature | 40°C |
| Prism Housing | Metal (Aluminum Alloy) |
| Optical System | Single-lens, high-transmittance eyepiece |
| Ergonomic Design | Balanced weight distribution, optimized grip geometry |
| Liquid Clearance | Rapid drainage groove on prism surface |
| Compliance | Designed per JIS K 0061 and ISO 21527-1 for refractometric sugar analysis |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 2391 |
| Product Type | Handheld Refractometer |
| Temperature Compensation | Automatic (ATC) |
| Measurement Range | 0.0–33.0% Brix |
| Minimum Scale Division | 0.2% Brix |
| Accuracy | ±0.2% Brix (at 10–30°C) |
| Repeatability | ±0.1% Brix |
| Dimensions | 3.3 × 3.3 × 20.4 cm |
| Weight | 100 g |
| IP Rating | IP65 (excluding eyepiece area) |
| Accessories | RE-29401 Extractor, RE-110010 (10% sucrose standard, ±0.03%), RE-110030 (30% sucrose standard, ±0.03%), RE-2311-55M micro-sample prism cover, RE-2311-54M daylight plate |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MASTER-α |
| Price | Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | NAR-4T High-Index Abbe Refractometer |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | nD 1.4700–1.8700 |
| Accuracy | ±0.0002 nD |
| Resolution | 0.001 nD |
| Temperature Range | 5–50 °C |
| Temperature Accuracy | ±0.2 °C (ambient) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 5 VA |
| Dimensions (main unit) | 13 × 18 × 23 cm |
| Weight (main unit) | 1.8 kg |
| Dimensions (temperature display module) | 10 × 11 × 7 cm |
| Weight (temperature display module) | 0.5 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | NAR-4T |
| Product Type | Benchtop Abbe Refractometer |
| Temperature Control | Yes |
| Digital Display | No |
| Measurement Range (nD) | 1.4700–1.8700 |
| Resolution (nD) | 0.001 |
| Accuracy (nD) | ±0.0002 |
| Temperature Range | 5–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C (0–99 °C) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 5 VA |
| Dimensions (Main Unit) | 13 × 18 × 23 cm |
| Weight (Main Unit) | 1.8 kg |
| Dimensions (Temperature Display Unit) | 10 × 11 × 7 cm |
| Weight (Temperature Display Unit) | 0.5 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | NAR-4T (High Refractive Index) |
| Measurement Range | 1.4700–1.8700 nD |
| Accuracy | ±0.0002 nD |
| Temperature Control | Yes |
| Digital Display | Yes |
| Instrument Type | Benchtop Abbe Refractometer |
| Compliance | ISO 2163, ASTM D1218, JIS K0061 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-03S (Clinical & Sports Series) |
| Type | Handheld Digital Refractometer |
| Measurement Range | 0.0–45.0% (w/w NaCl equivalent) |
| Accuracy | ±0.4% |
| Temperature Control | None |
| Display | Digital LCD |