| Brand | Amplitude |
|---|---|
| Origin | France |
| Type | Solid-State Femtosecond Laser Oscillator & Amplifier System |
| Model | Tangor300 |
| Average Output Power | 300 W |
| Repetition Rate | Up to 40 MHz (adjustable) |
| Pulse Energy | Up to 3 mJ (configurable via beam splitting) |
| Pulse Duration | <500 fs (typical, sub-100 fs optional with nonlinear compression) |
| Burst Mode | FemtoBurst™ (user-defined pulse count, inter-pulse spacing 25–100 ns) |
| Triggering | FemtoTrig™ (external TTL/trigger-selectable single-pulse emission) |
| Synchronization | SuperSync Control (sub-nanosecond jitter, compatible with high-speed galvo/scanner systems) |
| Optional Wavelength Conversion | UV output up to 100 W (via harmonic generation), Green output available |
| Brand | Amplitude |
|---|---|
| Origin | France |
| Product Type | Diode-Pumped Nd:Glass Amplifier System |
| Model | Titan Series |
| Wavelength | 532 nm / 1064 nm |
| Pulse Energy | 6 J @ 532 nm, 8 J @ 1064 nm (Single Beam) |
| Repetition Rate | 1 Hz or 5 Hz |
| Pulse Width | ~12 ns |
| Energy Stability | 1.2% RMS (1000 shots), 1.0% RMS (1000 shots) |
| Energy Drift | ≤5% over 8 hours |
| Beam Profile | Top-Hat (Flat-Top) |
| Temporal Jitter | 0.5 ns RMS |
| Polarization | Vertical @ 532 nm |
| Optional Configuration | Dual-Pulse Mode (two 12 ns pulses with adjustable inter-pulse delay) |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NEP180 |
| Price Range | USD 2,700 – 6,800 (FOB) |
| Product Type | In-Line Sensor |
| Measurement Range | 0–30,000 NTU |
| Resolution | 10 NTU |
| Operating Temperature | −10 °C (non-frozen) to 40 °C |
| Accuracy | ±2% |
| Brand | Andover Corporation |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Pricing | Available upon Request |
| Substrate | BK7 or Borofloat® (optional) |
| Thickness | ≤4.0 mm |
| Clear Aperture | ≥85% of outer dimension |
| Surface Quality | 80–50 per MIL-C-48497A |
| Flatness | 3–5 waves @ 25 mm (TWFS) |
| Operating Temperature | −50 °C to +200 °C |
| Humidity & Abrasion Resistance | Compliant with MIL-C-675C |
| Cut-on Slope (LWP) | ≤6% (≤11% for 300 nm filter) |
| Cut-on Tolerance | ±10 nm (400–1100 nm), ±5 nm (300–375 nm) |
| Avg. Transmission (LWP) | ≥85% from 50% cut-on point to 2000 nm |
| Blocking (LWP) | ≥99% from 0.9× cut-on to UV |
| Effective Refractive Index (n*) | ~1.7 |
| Wavelength Range | 300–1000 nm (50 nm increments standard) |
| Edge Steepness | Significantly steeper than colored-glass filters |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 005 |
| Pricing | Available Upon Request |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | FEA-5023 |
| Product Type | Handheld Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3330–1.5290 |
| Ethanol Concentration Range (v/v) | 3%–13% |
| Measurement Precision (Refractive Index) | ≤ ±0.003 RIU (equivalent to ≤3% relative error in ethanol quantification) |
| Dimensions | 250 × 200 × 75 mm |
| Power Consumption | 5 W |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–50 °C |
| Operating Humidity | 20–80% RH |
| Storage Humidity | 5–90% RH |
| Key | Brand: Anritsu |
|---|---|
| Model | AF4B116AA75L |
| Wavelength | 1475 ± 15 nm |
| Output Power | Up to 650 mW |
| Fiber Type | SMF or PMF |
| Package | 14-pin butterfly with TEC and monitor PD |
| Compliance | Telcordia GR-468-CORE, RoHS |
| Application | EDFA pumping |
| Origin | Japan |
| Core Technology | FP-LD (Fabry–Pérot Laser Diode) |
| Brand | Anritsu |
|---|---|
| Model | MS9740B |
| Wavelength Range | 600 nm – 1750 nm |
| Wavelength Accuracy | ±20 pm (C/L-band, with calibration source) |
| Resolution Bandwidth | 0.03 nm – 1.0 nm (selectable) |
| Dynamic Range | >58 dB (at ±0.4 nm from peak, 0.05 nm RBW) |
| Sensitivity | –90 dBm |
| Minimum Resolution | 30 pm |
| SMSR Measurement Limit | ≥45 dB |
| SMSR Reproducibility | ±1.4 dB |
| Scan Speed | ≤0.2 s (5 nm span, 0.1 nm RBW) |
| Input Fiber Compatibility | SMF, MMF (50/125 µm, 62.5/125 µm) |
| Connector Types | FC, SC, ST, DIN (LC via adapter) |
| Max Input Power | +23 dBm (with attenuator) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, ±0.03 °C accuracy (verified by T-Check system) |
| Display | Digital LCD |
| Refractive Index Range | 1.33 to 1.55 nD |
| Accuracy | ±0.0001 nD |
| Sample Volume | As low as 70 µL |
| Prism Material | Sapphire (Mohs hardness 9) |
| Measurement Cycle Time | As low as 10 seconds |
| Additional Scales | Brix, % w/w, % v/v, g/100g, etc. |
| Predefined Methods | 1 primary + 8 swappable application-specific methods |
| Compliance | Fully traceable temperature calibration |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 3200 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.30 to 1.72 |
| Refractive Index Accuracy | ±0.0001 |
| Measurement Time | ~5 s (after thermal equilibration) |
| Sample Volume | ~0.2 mL |
| Light Source | LED at 589 nm |
| Interface | RS-232, 2× USB, Ethernet, LIMS-compatible |
| Display | 5.8-inch color touchscreen |
| Dimensions (W×H×D) | 228 × 94 × 300 mm |
| Weight | 4.6 kg |
| Prism Material | Sapphire |
| Wetted Materials | Sapphire, perfluoroelastomer, PP-GF30, stainless steel |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 350 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.26–1.72 |
| Refractive Index Accuracy | ±0.0001 |
| Temperature Control Range | 4–85 °C |
| Temperature Stability | ±0.002 °C |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time (post-equilibration) | 5 s |
| Light Source | LED, 589 nm, >100,000 h lifetime |
| Prism Material | Sapphire |
| Compliant with | FDA 21 CFR Part 11, GMP, GAMP 5, USP <851>, Ph. Eur., JP |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 450 / Abbemat 650 / Abbemat HT / Abbemat MW |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Accuracy | ±0.00001 (Abbemat 450), ±0.000001 (Abbemat 650 & HT) |
| Refractive Index Range | 1.26–1.72 (450/650), 1.30–1.72 (HT) |
| Brix Range | 0–100% |
| Temperature Range | 4–85 °C (450/650), 10–110 °C (HT) |
| Wavelength | 589.3 ± 0.1 nm (Na D-line) |
| Light Source | LED (>100,000 h lifetime) |
| Prism Material | Synthetic Sapphire (450/650), YAG (HT/MW) |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time | 5 s (post-thermal equilibrium) |
| IP Rating | IP68 (450/650) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, 3Q Documentation Available (DQ/IQ/OQ/PQ) |
| Connectivity | RS-232, CAN bus, Ethernet, VGA |
| Software | Windows-based PDC (Precision Data Control) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.33 nD to 1.55 nD |
| Measurement Accuracy | ±0.0001 nD |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 550 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range (nD) | 1.26–1.72 |
| Refractive Index Accuracy (nD) | ±0.000001 |
| Refractive Index Precision (nD) | ±0.000001 |
| Brix Range | 0–100 % |
| Brix Accuracy | ±0.015 % |
| Temperature Control Range | 4–85 °C |
| Temperature Stability | ±0.002 °C |
| Temperature Probe Accuracy | ±0.03 °C |
| Wavelength | 589 nm (Na-D line) |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time (post-equilibration) | 5 s per sample |
| Light Source | LED (Lifespan > 100,000 h) |
| Prism Material | Sapphire (Vickers hardness ≈ 2000 HV) |
| Compatible Sample Types | Liquids, pastes, polymers, solids, turbid, colored, and opaque materials |
| Compliance | FDA 21 CFR Part 11, GMP, GAMP 5, USP <1058>, Ph. Eur., JP |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Abbemat 7001 / Abbemat 7201 |
| Form Factor | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.33 nD to 1.55 nD (Abbemat 7001) |
| Refractive Index Accuracy | ±0.0001 nD (7001) |
| Refractive Index Resolution | 0.0001 nD (7001) |
| Temperature Range | 20 °C to 40 °C (7001) |
| Temperature Accuracy | ±0.05 °C (7001) |
| Brix Range | 0–100 °Brix |
| Brix Accuracy | ±0.05 °Brix (7001) |
| Sample Volume | 70 µL (microflow cell) |
| Max Operating Pressure | 10 bar |
| Prism Material | Synthetic Sapphire (Mohs hardness 9) |
| Light Source | LED @ 589.3 nm (interference filter stabilized) |
| Interface | 1× Ethernet, 3× USB-B, CAN bus for DMA/MCP/SVM/Xsample integration |
| Data Storage Capacity | 10,000 measurements (7001) |
| Compliance | 21 CFR Part 11, EU GMP Annex 11, GAMP 5, ISO/IEC 17025 applicable |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.26–1.72 |
| Accuracy (nD) | ±0.0001 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Integrated Peltier |
| Digital Display | Yes |
| Refractive Index Range | 1.30–1.72 nD |
| Refractive Index Accuracy | ±0.000001 nD |
| Wavelength Options | 8 discrete wavelengths from 435.8 nm to 656.3 nm |
| Prism Material | YAG (Yttrium Aluminum Garnet) |
| Sample Volume | ~0.2 mL |
| Measurement Time per Sample | 5 s (after thermal equilibration and filter switching) |
| Temperature Range | 10–70 °C |
| Temperature Stability | ±0.002 °C |
| Calibration | Single- or two-point |
| Interface | RS-232 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat Series |
| Temperature Control | Yes |
| Digital Display | Yes |
| IP Rating | IP68 (Abbemat 450/650) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP |
| Measurement Principle | Critical Angle Method with LED-based Sodium D-Line (589.3 ± 0.1 nm) |
| Prism Material | Synthetic Sapphire (Abbemat 450/650), YAG (Abbemat HT/MW) |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time | <5 s (after thermal equilibration) |
| Temperature Range | −42 to +85 °C (Abbemat 450/650), 10 to 110 °C (Abbemat HT), adjustable for MW models |
| Refractive Index Range | 1.26–1.72 (nD), accuracy ±0.00002 to ±0.00004 nD |
| Brix Range | 0–100 %, resolution 0.001 % |
| Temperature Stability | ±0.002 °C |
| Light Source | Long-life LED (>100,000 h) |
| Interfaces | RS-232, CAN bus, Ethernet, VGA (PC-dependent) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Carbo |
| Product Type | Online Refractometer-Based CO₂ Sensor |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0–20 g/L (0–10 vol%) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Haze 3001 |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0–400 NTU |
| Resolution | 0.01 NTU |
| Operating Ambient Temperature | 15–35 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | MCP 100 |
| Product Type | Automatic Polarimeter |
| Temperature Control | Peltier-based, programmable (20 °C and 25 °C standard setpoints) |
| Display | 5.7″ TFT color touchscreen (640 × 480 px) |
| Light Source | LED (589 nm, 100,000 h lifetime) |
| Measurement Range | ±89.9° optical rotation (OR) |
| Resolution | 0.001° |
| Accuracy | ±0.01° |
| Repeatability | ±0.01° |
| Response Time | 12 s |
| Wavelength | 589 nm (sodium D-line equivalent) |
| Temperature Sensor | Integrated PT100 |
| Temp. Accuracy | ±0.2 °C |
| Temp. Stability | ±0.1 °C |
| Cell Length Support | 2.5–100 mm |
| OD Compensation | Up to 2.0 |
| Interfaces | 3× USB, RS232, Ethernet, CAN bus |
| Dimensions (L×W×H) | 370 × 320 × 130 mm |
| Weight | 7.8 kg |
| Power | 100–240 VAC, 50/60 Hz, max. 120 VA |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Origin | Imported |
| Model | MCP 100/150 |
| Product Type | Automatic Polarimeter |
| Temperature Control | Peltier-controlled |
| Digital Display | Yes |
| Light Source | LED |
| Measurement Range | ±89.9° |
| Measurement Resolution | 0.001° |
| Measurement Accuracy | ±0.004° (MCP 150), ±0.01° (MCP 100) |
| Wavelength | 589 nm |
| Temperature Control Range | 15–35 °C |
| Temperature Accuracy | ±0.1 °C (MCP 150), ±0.2 °C (MCP 100) |
| Sample Cell Recognition | Toolmaster™ wireless identification |
| Interface | 3× USB, RS232, Ethernet, CAN bus |
| Dimensions (L×W×H) | 370 × 320 × 130 mm |
| Weight | 7.8 kg (MCP 100), 8.6 kg (MCP 150) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | MCP 150 |
| Product Type | Automatic Polarimeter |
| Temperature Control | Peltier-based (15 °C to 35 °C) |
| Display | 5.7" TFT touchscreen (640 × 480 px) |
| Light Source | LED (589 nm, 100,000 h lifetime) |
| Measurement Range | ±89.9° |
| Resolution | 0.001° |
| Accuracy | ±0.004° |
| Repeatability | ±0.004° |
| Response Time | ≤12 s |
| Optical Density Compensation | up to OD 2.0 |
| Temperature Sensor | Integrated PT100 |
| Temp. Accuracy | ±0.1 °C |
| Temp. Resolution | 0.1 °C |
| Sample Cell Recognition | Toolmaster™ RFID auto-identification |
| Cell Length Compatibility | 2.5 mm to 100 mm |
| Interfaces | 3× USB-A, USB-B, RS232, Ethernet, CAN bus |
| Dimensions (L×W×H) | 370 × 320 × 130 mm |
| Weight | 8.6 kg |
| Power Supply | 100–240 VAC, 50/60 Hz, max. 120 VA |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | MCP 200/300/500 |
| Product Type | Automated Polarimeter |
| Temperature Control | Peltier-based, programmable (±0.1 °C stability) |
| Display | High-resolution color touchscreen |
| Light Source | Stable, narrow-band LED (589.44 nm nominal, optionally up to 8 wavelengths from UV to NIR) |
| Compliance | Fully compliant with USP <781>, EP 2.2.7, JP 2.06, ASTM E1255, OIML R 130, and FDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access control) |
| Data Integrity | GLP/GMP-ready with tamper-proof audit trail, password-protected user levels (Operator, Supervisor, Administrator), and QM-certified firmware |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MCP 4100 / MCP 5100 / MCP 5500 |
| Product Type | Automated Polarimeter |
| Temperature Control | Peltier-controlled (10–45 °C) |
| Display | High-resolution touchscreen interface |
| Light Source | Long-life LED (325–880 nm, up to 8 selectable wavelengths) |
| Measurement Range | ±89.9° optical rotation (OR) |
| Accuracy | ±0.003° OR (MCP 4100), ±0.002° OR (MCP 5100), <±0.002° OR (MCP 5500) |
| Resolution | 0.0001° OR |
| Repeatability | ±0.002° OR (MCP 4100/5100), ±0.001° OR (MCP 5500) |
| Temperature Accuracy | ±0.1 °C (MCP 4100/5100), ±0.03 °C (MCP 5500) |
| Sample Cell Max Length | 200 mm |
| Compliance | Fully 21 CFR Part 11 compliant, GLP/GMP-ready, USP/EP/ChP-compliant, OIML R 167, ASTM E1254, ICUMSA Method GS4/3-12 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Automatic Polarimeter |
| Temperature Control | Peltier-controlled |
| Digital Display | Yes |
| Light Source | LED (589 nm, optional 880 nm) |
| Measurement Range | ±259 °Z (±89.9 °OR) |
| Measurement Accuracy | ±0.003 °OR (MCP 5300), ±0.01 °Z (MCP 5500) |
| Temperature Accuracy | ±0.1 °C |
| Repeatability | <0.001 °OR / <0.003 °Z |
| Response Time | 12–15 s |
| Wavelength Options | 589 nm (standard), 880 nm (ICUMSA-compliant upgradeable) |
| Optical Density Range | Up to OD 4.0 (589 nm), OD 7.0 (880 nm) |
| Sample Cell Lengths | 2.5–200 mm (ToolMaster™ RFID auto-recognized) |
| Dimensions (L×W×H) | 797 × 437 × 231 mm |
| Weight | 33.5 kg |
| Power Supply | 100–240 VAC, 50/60 Hz, 185 VA |
| Interfaces | 4× USB, RS232, Ethernet, VGA, CAN bus |
| Brand | AOE Tech |
|---|---|
| Origin | Shanghai, China |
| Model | AC201-Rb |
| Cell Body Material | Pyrex or Fused Silica |
| Cell Diameter | Φ10 / 15 / 20 / 25.0 ± 1.6 mm |
| Cell Length | 10 / 20 / 50 / 100.0 ± 0.8 mm |
| Window Thickness | 3.0 ± 0.8 mm |
| Window Angle | 0° (Flat Parallel) |
| Fill Species | Rb (⁸⁵Rb / ⁸⁷Rb), optionally with buffer gases (He, Ne, CH₄, C₂H₆) |
| Operating Temperature Range (heated variant) | 40–200 °C |
| Compliance | Designed for traceable wavelength calibration per ISO/IEC 17025-aligned optical metrology workflows |
| Brand | AOE Tech |
|---|---|
| Origin | Shanghai, China |
| Model | HT-M1000020 |
| Cavity Aperture | 20 mm |
| Temperature Range | 5–1000 °C |
| Temperature Stability | ±0.1 °C / 30 min |
| Emissivity | 0.95 or 0.99 (selectable) |
| Temperature Resolution | 0.1 °C (standard), 0.01 °C (high-res option) |
| Temperature Accuracy | ±(0.15 °C + 0.002 × |
| Power Supply | 220 V ±1%, 50/60 Hz, 35 A |
| Dimensions (standard) | 395 × 200 × 252 mm (L×W×H) |
| with chopper | 230 × 296 × 278 mm |
| Compliance | Designed for ISO/IEC 17025-compliant calibration labs, compatible with ASTM E1545, ISO 18434-1, and MIL-STD-2154 thermal radiation source requirements |
| Brand | AOE Tech |
|---|---|
| Model | HT-Series |
| Cavity Material | High-Purity Alumina Ceramic (Corundum) |
| Temperature Range | 300–1700 °C |
| Emissivity | ≥0.99 |
| Temperature Uniformity | ≤±0.5 °C across cavity aperture |
| Temperature Stability | ≤±0.1 °C / 30 min (at setpoint ≥1000 °C) |
| Temperature Resolution | 0.1 °C (≤1000 °C), 1 °C (>1000 °C) |
| Temperature Accuracy | ±(0.15 °C + 0.003× |
| Aperture Diameters | 24 mm, 30 mm, 40 mm |
| Standard Configurations | HT-H1200-040, HT-H1450-024, HT-H1450-030, HT-H1450-040, HT-H1700-040 |
| Housing Type | Integrated or Split-Body (Split: 550 × 584 × 913 mm |
| Integrated | 451 × 446 × 442 mm) |
| Power Supply | 220 V ±1%, 50/60 Hz, 35 A |
| Optional | Precision Aperture Diaphragms (ISO 11554 compliant) |
| Brand | AOE Tech |
|---|---|
| Model | JF-H510i |
| Category | Optical Multimeter (Integrated Light Source & Optical Power Meter) |
| Calibration Wavelengths | 850 / 980 / 1310 / 1490 / 1550 / 1625 nm |
| Power Meter Range (JF-H510A) | –70 to +6 dBm |
| Power Meter Range (JF-H510C) | –50 to +26 dBm |
| Resolution | 0.01 dBm |
| Uncertainty | ±5% dB |
| Source Wavelengths | 650 / 1310 / 1550 nm (FP-LD) |
| Typical Output Power | –7 dBm |
| Power Supply | 3 × AA batteries |
| Auto-off Delay | 10 min |
| Battery Life | 28 h (power meter only) / ≥4 h (dual operation) |
| Operating Temperature | –10 °C to +60 °C |
| Dimensions | 189 × 99.4 × 49.8 mm |
| Weight | 245 g |