Other Common Laboratory Equipment
Filter
Showing 271–300 of 400 results
| Brand | Meiyingpu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 316L |
| Pricing | Available Upon Request |
| Custom Height Adjustment | Yes |
| Material | ASTM A240 UNS S31603 316L Stainless Steel |
| Standard Diameters (cm) | Φ25, Φ30, Φ35, Φ40, Φ45, Φ50, Φ55, Φ60, Φ70 |
| Standard Heights (cm) | 25, 30, 35, 40, 45, 50, 60, 70, 80 |
| Surface Finish | Electro-polished (Ra ≤ 0.4 µm) |
| Compliance | Meets ASTM A240, ISO 8502-3, and FDA 21 CFR Part 110 for food contact surfaces |
| Brand | Nano-Master |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Equipment |
| Model | NTE-3500 (M) |
| Price Range | USD 110,000 – 140,000 |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-152 |
| Coarse Travel (X/Y/Z) | 25 mm / 20 mm / 25 mm |
| Fine Adjustment Resolution | Sub-micrometer (via optional single-axis micrometer drive) |
| Dimensions (W×D×H) | 95 × 36 × 135 mm |
| Weight | 320 g |
| Standard Accessory | B-8B Spherical Joint |
| Optional Upgrade | Uniaxial Micrometer Drive (pipette-aligned axis) |
| Brand | NAYO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A96 |
| Pricing | Available Upon Request |
| Brand | ADVANTEC (Yan Hua Dong Yang) |
|---|---|
| Origin | Japan |
| Model | 10-905 |
| Type | Manual Date/Number Embossing Punch |
| Max. Sheet Capacity | 10 sheets (64 g/m² paper, 8-digit imprint) |
| Cycle Time | 1.5 s/cycle (50 Hz) / 1.2 s/cycle (60 Hz) |
| Dimensions | 214 × 295 × 485 mm |
| Weight | 12.7 kg |
| Die Block Compatibility | MOLE 905-208 |
| Power Supply | None (Manual Operation) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Dispet Ex |
| Dispensing Range | 0.2–10 mL (DP-10), 0.4–20 mL (DP-20), 1–5 mL (DP-5), 2–10 mL (DP-10) |
| Minimum Increment | 0.05–0.25 mL |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤0.2% |
| Bottle Compatibility | Ø22 mm (for DP-5/DP-10), up to Ø45 mm (with optional adapters) |
| Adapter Options | DP-1118 (18 mm), DP-1119 (19 mm), DP-1122 (22 mm), DP-1124 (24 mm), DP-1125 (25 mm), DP-1128 (28 mm), DP-1133 (33 mm), DP-1138 (38 mm), DP-1145 (45 mm) |
| Included Accessories | One 220 mm flexible PTFE-lined tubing (user-cuttable) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28, GL-32, GL-45 (bottles sold separately) |
| Liquid Contact Materials | Chemically resistant PTFE, FEP, and ETFE components |
| Design | Handheld, portable, ergonomic manual dispenser |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET Mini |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28 standard thread |
| Liquid Contact Materials | Chemically resistant PTFE, ETFE, and FEP components |
| Regulatory Compliance | Designed for ISO 8655-compliant volumetric dispensing procedures |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NSS-1000II Basic |
| Type | Benchtop Robotic Liquid Handler |
| Configuration | Standalone or Integrated Platform |
| Programming Interface | C-language or Visual Basic SDK |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Application Scope | Life Sciences, Pharmaceutical R&D, Clinical Diagnostics, Chemical Laboratories |
| Brand | NuAire |
|---|---|
| Origin | USA |
| Model | 5700 |
| Effective Volume | 160 L |
| Internal Dimensions (W×D×H) | 514 × 525 × 610 mm |
| External Dimensions | 648 × 699 × 894 mm |
| Control Interface | 5″ × 7″ Full-Color Touchscreen with 2-Month Historical Data Logging |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Uniformity | ±0.3 °C @ 37 °C |
| Temperature Accuracy | ±0.1 °C |
| Temp Recovery Rate | 0.12 °C/min (avg.) |
| Temp Resolution | 0.1 °C |
| CO₂ Sensor | Dual-Wavelength NDIR |
| CO₂ Range | 0.1–20% |
| CO₂ Accuracy | ±0.1% |
| CO₂ Recovery | ≤5 min to 5.0% ±0.5%/+0.2% |
| CO₂ Resolution | 0.1% |
| RH Range | Ambient to 90% RH |
| RH Accuracy | +5%/−3% |
| Humidification Reservoir | ~3 L |
| O₂ Sensor | Zirconia Electrochemical |
| O₂ Range | 0.5–21% |
| O₂ Accuracy | ±0.25% |
| Sterilization Modes | 95 °C Wet-Heat & 145 °C Dry-Heat Cyclic |
| Chamber Material | Stainless Steel with Rounded Corners |
| Inner Door | Tempered Glass |
| Standard Shelving | 4 Adjustable, Autoclavable Slides (max. 16) |
| HEPA System | External Closed-Loop Class ISO 5 (≤100 particles/ft³ ≥0.5 µm), Non-Intrusive Placement |
| Brand | NuAire |
|---|---|
| Origin | USA |
| Model | 8600 |
| Chamber Volume | 160 L |
| Internal Dimensions (W×D×H) | 518 × 524 × 611 mm |
| External Dimensions | 649 × 685 × 958 mm |
| Control Interface | 5″ × 7″ Full-Color Touchscreen with 2-Month Data Logging |
| Temperature Range | Ambient +5°C to 55°C |
| Temp Uniformity | ±0.20°C @ 37°C |
| Temp Accuracy | ±0.1°C |
| Temp Recovery Rate | 0.12°C/min (avg.) |
| Temp Resolution | 0.1°C |
| CO₂ Sensor | Dual-Wavelength NDIR |
| CO₂ Range | 0.1–20% |
| CO₂ Accuracy | ±0.1% |
| CO₂ Recovery | ≤5 min to achieve ±0.5%/+0.2% of setpoint at 5.0% |
| CO₂ Resolution | 0.1% |
| O₂ Sensor | Zirconia Electrochemical |
| O₂ Range | 0.5–21% |
| O₂ Accuracy | ±0.25% |
| Filtration | Integrated Recirculating ISO Class 5 HEPA System (external to chamber) |
| Interior | Stainless Steel, Rounded Corners, Full-View Glass Inner Door |
| Humidification | Standard Full-Size Water Pan |
| Shelving | 4 Standard Slides (max. 16), Autoclavable Rails & Shelves |
| Filter Access | Front-Mounted, Bottom-Positioned HEPA Intake for Visual Inspection & Tool-Free Replacement |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PlasmaPro 100 Cobra |
| Wafer Capacity | Single-wafer and batch processing up to 200 mm |
| Temperature Range | −150 °C to +400 °C |
| Electrode Cooling/Heating | Liquid nitrogen, recirculating chiller, or resistive heating |
| RF Power Delivery | Top-mounted electrode with dual-frequency (LF/RF) capability |
| ICP Source Options | 65 mm, 180 mm, 300 mm |
| Process Pressure Range | Wide operational window enabled by high-pumping-speed vacuum system |
| Substrate Thickness Compatibility | Up to 10 mm |
| Backside He–cooling | Integrated electrostatic chuck with helium backside cooling |
| Endpoint Detection | Real-time optical emission spectroscopy (OES) monitoring |
| Chamber Architecture | Symmetric, low-inductance plasma chamber with uniform gas distribution and high-conductance pumping path |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurin i4 |
| Isolation Start Frequency | 0.6 Hz |
| Peak Isolation Performance | −40 dB at 10 Hz (99% vibration attenuation) |
| Settling Time | 0.3 s |
| Degrees of Freedom | 6-DOF active compensation |
| Power Supply | Standard AC outlet (no compressed air required) |
| Load Auto-Adaptation | Yes |
| Transport Lock | Integrated and automatic |
| Structural Stiffness | High intrinsic rigidity for positional stability |
| Compliance | Designed for ISO 14644-1 Class 5–8 cleanroom environments and compatible with GLP/GMP-aligned lab infrastructure |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurion Nano Series |
| Type | Active 6-DOF Vibration Isolation System |
| Operating Frequency Range | Active isolation from 0.7 Hz, passive isolation up to 200 Hz |
| Setup Time | < 0.3 s |
| Power Supply | Standard AC mains (no compressed air required) |
| Controller | External low-heat, EMI-isolated electronics unit |
| Structural Frame | Optional welded steel support table with high horizontal & vertical stiffness |
| Compliance | Designed for ISO 14644-1 Class 5 cleanroom-compatible environments and GLP/GMP-aligned lab infrastructure |
| Sample Load Capacity | Optimized for light-weight, high-sensitivity instruments (e.g., AFM, optical interferometers, nanoindenter stages) |
| Brand | Park SYSTEMS |
|---|---|
| Origin | Germany |
| Model | i4 |
| Dimensions | 400 × 500 × 90 mm |
| Payload Capacity | 0–120 kg |
| Active Isolation Bandwidth | 0.6/1 Hz to 200 Hz |
| Degrees of Freedom | 6-DOF |
| Settling Time | ≤ 0.3 s |
| Power Supply | Standard AC Mains (No Compressed Air Required) |
| Stiffness at 1 Hz | 20–30× Higher Than Passive Air Tables |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 4871 High-Pressure, Precision-Temperature-Controlled Corrosion Research System |
| Pricing | Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Instrument Type | Imported Laboratory System |
| Model | 2901 Ignition Propellant Combustion & Ultra-Fast Pressure Release Curve Analyzer |
| Pricing | Available Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | VLE-2000 Vapor-Liquid Equilibrium (VLE) Vapor Pressure Measurement System |
| Pricing | Available Upon Request |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PE Drum |
| Pricing | Available Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-800 |
| Sample Capacity | ≤5 g (solid) / ≤15 mL (liquid) |
| Nitrogen Range | 0.08–200 mg N |
| Recovery Rate | >99.5% |
| Precision (RSD) | ≤0.5% |
| Distillation Time | 1–99 min |
| Distillation Rate | 14–28 mL/min (adjustable) |
| Power Adjustment | 750–1500 W |
| Cooling Water Requirement | ≥1.5 L/min at ≤20 °C, min. pressure 0.15 MPa |
| Data Storage | ≥100 distillation programs, ≥1000 sample records |
| Safety Features | Dual-level digestion flask level sensing, real-time cooling water flow/pressure monitoring, reagent level detection (H₂SO₄, NaOH, boric acid, diluent), digestion chamber temperature monitoring, condensate temperature cutoff, interlocked safety door sensor, intermittent alkali addition control |
| Construction | Monolithic ABS engineering plastic chassis |
| Dimensions | 370 × 300 × 680 mm |
| Electrical | 220 V AC, 50 Hz, 3.5–7 A |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | N9300808 |
| Voltage | 115/230 V |
| Temperature Setpoint Resolution | 0.1 °C |
| Language Options | 10 |
| Safety Messaging | Yes |
| Timer with Auto Shut-off | Yes |
| Segment End Alarm | Yes |
| Integrated Calibration Routine | Yes |
| Compatible With | DigiPROBE Sample Preparation Blocks |
| Brand | Piezodrive |
|---|---|
| Origin | Australia |
| Model | PDUS210 |
| Output Power | 210 W |
| Output Voltage Range | 17–282 Vrms |
| Output Current Range | 0.7–11 Arms |
| Load Impedance Range | 1.5–400 Ω (optimized) |
| Frequency Range | 6–500 kHz |
| Waveform | Pure Sine |
| Control Interfaces | USB, RS485, Digital I/O (4-channel), Front Panel, Footswitch |
| Compliance | CE, RoHS |
| Software | Included PC-based control suite with real-time impedance analysis and resonance tracking |
| Brand | Pribolab |
|---|---|
| Model | MP2000S |
| Origin | Shandong, China |
| Construction | Aluminum oxide sample tray, food-grade stainless steel homogenizing probe |
| Dimensions (H×W×D) | 550 × 360 × 630 mm |
| Weight | 33 kg |
| Standard Tray Capacity | 6-position (compatible with 100 mL and 300 mL sample bottles) |
| Optional Trays | 10-position and custom configurations |
| Probe Speed Range | 0–25,000 rpm (10-step BLDC motor control) |
| Positioning Accuracy | < 0.5 mm (mechanical arm), repeatability < 0.1 mm |
| Cleaning System | Multi-solvent rinse + ultrasonic cleaning + reverse-rotation probe cleaning |
| Control Interface | Touchscreen with editable, savable homogenization methods |
| Homogenization Motion | Vertical amplitude adjustment during operation |
| Enclosure | Powder-coated steel housing with ergonomic 3D panel design |
| Brand | Asahi Sokki |
|---|---|
| Origin | Japan |
| Model | MCA-1500E |
| Heating Capacity | 1.5 kW |
| Operating Voltage | Single-phase 200 V AC |
| Temperature Range | 80–500 °C |
| Air Flow Rate | 20–200 Nℓ/min |
| Maximum Operating Pressure | 0.3 MPa |
| Sheath Material | SUS (AISI 304 or equivalent) |
| Insulation Resistance | ≥5 MΩ @ 500 V DC |
| Dielectric Strength | 400 V AC, 1 min, leakage current ≤10 mA |
| Surface Temperature | Reduced via optimized thermal design |
| Energy Efficiency | ~15% lower power consumption vs. conventional air heaters |
| Brand | Sartorius |
|---|---|
| Model | Midi Plus |
| Power | Rechargeable Li-ion battery (AC/DC compatible) |
| Weight | <120 g |
| Compatible Pipettes | 1–100 mL glass and plastic serological pipettes |
| Adapter Included | Proline 5 mL & 10 mL tip adapters |
| Control Method | Pressure-sensitive ergonomic button |
| Low-Battery Indicator | Yes |
| Stand Included | Yes |
| Optional Accessory | Wall-mounted holder |
| Brand | Sartorius |
|---|---|
| Origin | Finland (Manufactured) |
| Model | eLine |
| Type | Motorized Single-Channel Electronic Pipette |
| Power | Rechargeable Lithium-Ion Battery |
| Display | Backlit LCD with Icon-Based Interface |
| Pipetting Modes | 11 Predefined (e.g., Standard, Reverse, Dilution, Dispense, Repeat, Mix, Variable Volume, Stepwise, Programmed Aspirate/Dispense, Calibration Mode, Error Log Review) |
| User Programs | Up to 6 Custom Protocols with Audit Trail |
| Tip Ejection | Motorized, One-Touch Electronic Eject |
| Charging Options | Dedicated eLine Charging Station (Docking Cradle) or Optional AC Adapter (Fast Charge Support) |
| Ergonomics | Ambidextrous Design with Adjustable Grip Angle and Low Actuation Force |
| Compliance | ISO 8655-2:2022 (Pipettes), ISO 13485:2016 (QMS), CE Marked for IVDD & MDR |
| Brand | Sartorius |
|---|---|
| Origin | Imported (Germany) |
| Model | Proline |
| Capacity Range | 0.01–50 mL |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Chemical Resistance | High (PTFE, FEP, PEEK, borosilicate glass) |
| Dispensing Accuracy | ±0.5% (v/v) |
| Repeatability | ≤0.2% CV |
| Valve Type | Leak-proof safety valve with positive shut-off |
| Dispensing Head | 360° rotatable |
| Tube Options | Standard dispensing tip or optional extension tube |
| Cleaning | Fully disassemblable |
| Thread Adapters | Includes universal adapter set (GL32, GL38, GL45, GL50, GL55, GL60, GL70, GL80) |
| Brand | Semicircle-Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HVP10P10BN-DS |
| Output Voltage | 0–10 kV DC |
| Output Current | 0–2 mA |
| Max. Output Power | 10 W |
| Filament Supply | 0–4 V DC / 0–2 A (adjustable current limit) |
| Input | 24 V DC ±10%, max. 2.0 A |
| Voltage Regulation | ≤0.01% (load) |
| Current Regulation | ≤0.01% (load) |
| Stability (8 h) | ≤0.05% after 30-min warm-up |
| Ripple | ≤0.3% pk-pk of rated output voltage |
| Monitoring Output | 0–10 V DC proportional to 0–Vmax & 0–Imax (Zout = 1 kΩ, accuracy ±1%) |
| Temp. Coefficient | 0.01% / °C |
| Inrush Surge Peak | ≤1 A @ 25°C |
| Operating Temp. | 0–50°C |
| Storage Temp. | −40 to +85°C |
| Weight | 0.4 kg |
| Dimensions | See mechanical drawing |
| Brand | Aitesen |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EUV250WH-1 |
| Price | USD 3,500 (FOB Japan) |
| Brand | Shanghai Yarong / Yarong |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RE-3000C |
| Price | Upon Request |
| Evaporation Flask Capacity | 50–3000 mL |
| Rotation Speed | 0–200 rpm (electronically controlled, stepless) |
| Heating Bath | 8 L PTFE-coated stainless steel bath with fully enclosed 1.2 kW heater |
| Temperature Control | Digital display, ambient to 99 ±1 °C |
| Lift Range | 0–150 mm (motorized, automatic vertical adjustment) |
| Power Supply | 220 V, 50 Hz |
| Overall Dimensions | 450 × 420 × 850 mm |
| Condenser | Horizontal dual-spiral coil, high-temp borosilicate glass, standard taper joints (24/29 or 29/32) |
| Feed System | Valve-type addition tube with PTFE tubing and flow baffle ring |
| Sealing | Fluoroelastomer (FKM) vacuum gaskets |
| Control Interface | Rocker-switch panel for lift actuation |
| Motor Power | 40 W |
| Vacuum Compatibility | Designed for stable operation under reduced pressure (typically 10–100 mbar) |
