| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMARTCHEM 140 |
| Pricing | Available Upon Request |
| [Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 200 |
| Product Type | Discrete Flow Analyzer |
| Measurement Speed | 200 samples/hr |
| Sample Capacity | 5 racks × 126 positions |
| Reaction Temperature | 37.2 °C ± 0.1 °C |
| Optical Range | 420–880 nm |
| Absorbance Linearity | 0.001–2.500 AUFS |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 300 µL |
| Pipetting Range | 3–450 µL |
| Dilution Factor | Up to 100× |
| Reagent Positions | 16 (10 refrigerated + 6 ambient) |
| Standard Positions | 10 |
| Diluent Positions | 2 |
| Filter Wheel | 9 optical filters + 1 blank filter |
| Reaction Cuvettes | 60-position rotating disc, semi-reusable, auto-cleaned and QC-verified |
| Compliance | ASTM, ISO, AOAC, US EPA Method 353.2 (NO₃⁻/NO₂⁻), AFNOR, COFRAC, BATF, USEPA] |
| [Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 300 |
| Pricing | Available Upon Request |
| Analysis Types | End-point, Kinetic, Differential, Dual-wavelength, Fixed-time |
| Reagent Positions | Up to 72 positions with refrigeration (4 movable racks × 16 slots + 8 fixed slots |
| Sample Positions | 4 universal sample carousels (15 positions each for cups or tubes Ø10–16 mm × 40–100 mm H) |
| Throughput | Up to 450 samples/h (with ISE module), 300 samples/h (photometric only) |
| Photometer | Dual-channel, direct-read, 9-position auto-select narrow-band interference filters (340–880 nm), 6 V/10 W halogen lamp, 6 mm pathlength, linear range 0.001–4.200 Abs, resolution 0.0001 Abs |
| Minimum Reaction Volume | 200 µL |
| Sample/Reagent Dispensing | Capacitive microdispenser, 3.0 µL–330 µL (1 µL increment), 37 °C reagent preheating, integrated probe washing, on-board dilution capability |
| Reaction Cuvettes | 80 reusable quartz/glass cuvettes across 4 independent rotating carousels (20 per carousel), automated cleaning with selectable acidic/alkaline/neutral wash solutions, temperature control at 37 °C ± 0.3 °C |
| Nitrate/Nitrite Module | Fully compliant with US EPA Method 353.2 |
| Optional ISE Module | Direct potentiometric measurement of Na⁺, K⁺, Cl⁻, Li⁺ (140 samples/h) |
| Barcode Scanning | Optional reagent and sample tube barcode readers |
| Compliance | ISO, AOAC, BATF, US EPA, AFNOR, COFRAC] |
| Brand | Brechbühler |
|---|---|
| Origin | Switzerland |
| Model | Sniffer9100 |
| Interface Tube Length | 80 cm or 140 cm |
| Control Module Dimensions | 350 × 375 × 195 mm |
| Temperature Control Range | 50–325 °C (1 °C resolution, max recommended 280 °C) |
| Output Signals | 0–1 V, 0–5 V, 0–10 V |
| I/O Synchronization | Start In, Stop In, Ready Out, Inhibit Ready In |
| Network Interface | TCP/IP LAN |
| Max Concurrent Units per GC | 3 |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Type | Imported Instrument |
| Model | InfraCal 2 TOG/TPH |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SR810, SR830 |
| Price | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EASYCHEM PLUS |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (18-sample carousel + auxiliary racks) |
| Reagent Positions | 18 |
| Flow Cell Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Spectral Output |
| Detection Principle | Photometric Colorimetry (Static Reaction in Flow-Through Cuvette) |
| Compliance | Designed for ASTM D129, ISO 6878, ISO 15681, USP <621>, EPA Methods 353.2, 365.2, 4500-NH₃ F, 4500-NO₂⁻ B, 4500-P E, and GLP/GMP-aligned workflows |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EasyChem Plus |
| Optical System | 6 V/10 W halogen lamp with UV extension |
| Filter Wheel | 10-position, 9 interference filters (340, 405, 480, 505, 546, 578, 630, 670, 880 nm |
| Photometric Range | 0–3 Abs |
| Accuracy | ±0.5% or ±1 mAbs (0.1–2.5 Abs) |
| Linearity | ±0.5% (0.1–1.5 Abs) |
| Flow Cell Pathlength | 15 mm or 50 mm selectable |
| Sample Capacity | 60 positions |
| Reagent Carousel | 30-position, refrigerated |
| Analysis Throughput | 60–90 determinations/hour |
| Detection Modes | Endpoint, Differential, Kinetic |
| Calibration Standards | 1–16 points |
| Dilution Precision | 500 µL syringe, 0.096 µL resolution |
| Software Compliance | Audit-trail enabled, QC database with multi-level control (e.g., Westgard rules), automatic pre- and post-dilution, on-board standard series generation |
| Brand | Systea |
|---|---|
| Origin | Italy |
| Model | Easychem Pro |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (standard carousel) / 30 positions (dual-carrousel configuration) |
| Reagent Positions | 30 |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Output |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | TESC-5133 |
| Temperature Control Range | −42 °C to 90 °C |
| Compliance | ASTM D5133, ASTM D7110, SH/T 0732, GB/T 11121 |
| Cooling Method | Solid-State Peltier |
| Sample Chamber | Sealed, Thermally Isolated Enclosure |
| Automation Level | Fully Automated, Unattended Operation |
| Footprint | Compact Benchtop Design |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Volume Range | 50–60 mL |
| Material | PTFE (Polytetrafluoroethylene) |
| Outer Diameter | 28–29 mm |
| Total Height | 135 mm |
| Cap Options | Threaded, Reflux, Handle, Dual-Integrated, Flared, Flat |
| Temperature Resistance | Up to 250 °C (ambient-pressure operation) |
| Compliance | ASTM D5511, ISO 11466, USP <231>, GLP-compliant sample handling |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Classification | Domestic (China) |
| Model | M6 Microwave Digestion Vessel |
| Price Range | USD 0.15 – 165 |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Fisher AutoAnalyzer Series |
| Pricing | Available Upon Request |
| Brand | THINKSENSO & SENSO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | iTongue20 |
| Price | Upon Request |
| Product Type | Taste Analysis System |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ACOD-30 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | APIA-100 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GC-IMS 2000 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | GC-IMS 3000 |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA 7Plus |
| Product Type | Flow Injection Analyzer |
| Category | Chemical Analysis Instrumentation — General Analytical Instruments — Flow Injection Analyzer |
| Manufacturer Status | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Type | Integrated Flow Injection Analyzer (FIA) System |
| Configuration | Fully Automated, Channel-Independent Modular Design |
| Standard Package | Auto-sampler, Main Unit, Control PC, Thermal Printer |
| Optional Modules | MAC3 Multi-Analyte Configuration Module (17 parameters) |
| Compliance Context | Designed for ASTM D129, ISO 6775, ISO 1192, EPA 300.0, EPA 354.1, USP <643>, and GLP/GMP-aligned data integrity workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 10–50 mL per vial / 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA L9 |
| Wavelength Range | 600–700 nm |
| Sample Capacity | 50–212 positions |
| Reagent Ports | 7 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA5+ |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA7 |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA7 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Flow Injection Analyzer |
| Model | iFIA7 Plus |
| Product Type | Flow Injection Analyzer |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | iFIAE |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume Capacity | 10–50 mL per vial |
| Sample Tray Capacity | 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L9 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | M-lab iFIA5 |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | M-lab iFIA5+ |
| Product Type | Flow Injection Analyzer |
| Portability | Integrated carry-on case with shock rating IK08, IP67-rated (submersible to 1 m for 30 min) |
| Detection Principle | Flow Injection Analysis (FIA) coupled with dual-beam spectrophotometry |
| Sample Introduction | Automated peristaltic pumping with intelligent flow path control |
| Pre-treatment Modules | On-board distillation, digestion, and liquid–liquid extraction |
| Detection Limits | Sub-ppb (ng/L) for target analytes including cyanide, phenols, ammonium, nitrate/nitrite, phosphate, Cr(VI), sulfide, and anionic surfactants |
| Software | Embedded method library, real-time system status monitoring, self-diagnostic interface, GLP-compliant audit trail |
| Connectivity | LAN and Wi-Fi enabled for multi-channel synchronization and remote operation |
| Compliance | Designed to support ASTM D3869, ISO 6776, ISO 15681-2, USP <621>, and EPA Method 354.1 workflows |