Other General Analytical Instruments
Filter
Showing 241–270 of 382 results
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | EA-HWG |
| Price | Upon Request |
| δ¹³C Precision (1σ) | <0.1–0.2 ‰ |
| CO₂ Measurement Range | 380–10,000 ppmv |
| Measurement Frequency | 4 Hz |
| Sample Flow Rate | 0.5 mL/s |
| Measurement Cell Volume | <1 mL |
| Operating Temperature | −10 to 45 °C |
| Miniature Vacuum Pump | 100 sccm @ 50 Torr |
| Sampling Pressure | 50–133 kPa |
| Carrier Gas | Ultra-High-Purity N₂ or He |
| Combustion Gas | Ultra-High-Purity O₂ |
| Relative Humidity Tolerance | <99% RH (non-condensing at 40 °C) |
| Calibration | Fully Automated Online Calibration |
| Interface Options | RS-232, Ethernet, USB |
| Inlet/Outlet Fittings | 1/8″ Swagelok |
| Dimensions (CO₂ Analyzer) | 483 × 800 × 476 mm (W×D×H) |
| Weight | 25 kg |
| Dimensions (Elemental Analyzer) | 813 × 394 × 508 mm |
| Weight | 68 kg |
| Power Requirement | 100–240 VAC |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | EA-MIR |
| Pricing | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | Domestic (China) |
| Model | PRI-3100 |
| Pricing | Upon Request |
| Channels | 16 independent |
| Ultimate Vacuum Pressure | 0.3 Pa |
| Pressure Range | 0.1–10⁵ Pa |
| Pressure Resolution | 0.1 Pa |
| Heating | Water Bath, Up to 100 °C |
| Cooling | Liquid Nitrogen, Down to −196 °C |
| Sample Tube Dimensions | 25 mm × 150 mm |
| Collection Tube Dimensions | 12.7 mm × 150 mm |
| System Leak Rate | ≤1 Pa/min |
| Extraction Recovery Rate | 99.5–100% |
| Max Throughput | 256 samples/day |
| Vacuum Pump Flow Rate | ≥8 m³/h |
| Brand | PRI-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | PRI-501w |
| Measurement Principle | Dual-Wavelength Non-Dispersive Infrared (Dual-NDIR) |
| CO₂ Range | 0–2000 ppm |
| CO₂ Accuracy | ±2% of reading (±1.5% after calibration) |
| CO₂ Zero Stability | ±2% over >12 months |
| CO₂ Repeatability (Zero) | ±0.3% |
| CO₂ Repeatability (Span) | ±1.5% |
| CO₂ Zero Drift (Constant Temp.) | ±2% per year |
| CO₂ Zero Drift (Ambient Temp.) | ±0.03% per °C |
| H₂O Range | 0–6% vol |
| H₂O Accuracy | ±2% of reading |
| Operating Temperature | −20 to +45 °C |
| Operating Pressure | 800–1150 mbar |
| Sample Flow Rate | 1 L/min (adjustable) |
| T₉₀ Response Time | 10 s (adjustable) |
| Warm-up Time | 1 min |
| Calibration Interval | Recommended annually |
| Max. Humidity | <99% RH (non-condensing) |
| Outputs | RS-232, Analog (0–5 V / 4–20 mA) |
| Dimensions | 250 × 160 × 90 mm |
| Weight | 3 kg |
| Power Supply | 7–28 V DC |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | PRI-8350 |
| CO₂ Range | 0–5% |
| CO₂ Precision | Better than 80 ppb or 0.01% of full scale |
| δ¹³C Precision | <0.3‰ (1σ) @ 1 s |
| H₂O Range | 0–100% RH |
| Sampling Frequency | 4 Hz (high-speed mode), 1 Hz (standard mode) |
| Response Time (10–90% / 90–10%) | 15 mL/min (fast), 5 mL/min (standard), down to 0.5 mL/min (ultra-low flow) |
| Number of Subsurface Channels | Standard 6-channel |
| Calibration Channels | Optional 3-channel configuration, customizable |
| Sampling Temperature | –20 to +45 °C |
| Sampling Flow Rate | 1 mL/min at 760 Torr, filter-free operation |
| Sampling Pressure | 300–1000 Torr (40–133 kPa) |
| Operating Temperature | –20 to +45 °C (extended range: –30 to +45 °C) |
| Power Consumption | 150 W |
| Input Voltage/Frequency | 110–220 VAC, 50–60 Hz |
| Dimensions (Host) | 483 mm (W) × 800 mm (D) × 476 mm (H) |
| Weight (Host) | 25 kg |
| Multiplexer Unit | Same footprint, 20 kg |
| Diffusion Probe | Standard single-channel 3 × 1 m (length × depth), customizable |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | U1001 |
| Pricing | Upon Request |
| Brand | Pribolab |
|---|---|
| Model | DR-3500 |
| Wavelength Range | 400–800 nm |
| Absorbance Range | 0.000–4.000 A |
| Detection Channels | 8-channel |
| Measurement Modes | Single-wavelength, Dual-wavelength, Two-point, Kinetic |
| Data Processing | Log-logit, Linear/Log/Exponential/Power/Double-logarithmic Regression, Cut-off Qualitative Analysis |
| Plate Format | Standard 96-well microplates |
| Throughput | ≤10 seconds per plate |
| Interface | Embedded touchscreen OS (Chinese), Optional PC connectivity via USB/Ethernet |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Pribolab |
|---|---|
| Model | LFR-I |
| Origin | Shandong, China |
| Sensor Type | 12-MP Hardware CMOS |
| Image Resolution | 1600 × 1200 |
| Detection Channel | Single-Channel |
| Interface | USB 2.0 |
| Operating Temperature | ≤40 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | USB-powered |
| Dimensions (L×W×H) | 350 mm × 150 mm × 100 mm |
| Operating System | Windows 10 |
| Display | 8.0-inch High-Resolution Color Touchscreen (Chinese UI) |
| Data Output | Integrated Thermal Printer (Chinese Sample Name & Lab ID Support) |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFR-II |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PEMFC-100 |
| Pricing | Available Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Origin Classification | Domestic |
| Model Range | 50–60 mL |
| Pricing | Upon Request |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DPC-2602 |
| Price Range | USD 140 – 39,500 (FOB) |
| Sensor Technology | 7th-Generation Dual-Laser Narrow-Beam Optical Detection |
| Particle Size Channels | Configurable Sets Including 0.3/0.5/1.0/2.5/5.0/10.0 µm |
| Counting Accuracy | <5% coincidence error at 2×10⁶ particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Time | Programmable (default 60 s) |
| Operating Temperature | 5–45 °C |
| Relative Humidity Limit | ≤90% RH (non-condensing) |
| Battery | Rechargeable 4100 mAh Li-polymer |
| Display | 3.45″ industrial-grade full-view color LCD |
| Data Storage | 10,000 measurement records |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, EU GMP Annex 1 (2022), USP <788> |
| Optional Modules | Integrated temperature/humidity sensor (–40 to 120 °C / 0–100% RH), CO/HCHO electrochemical gas sensors |
| Brand | PULUODY |
|---|---|
| Model | DPC-2611 |
| Detection Principle | Light Scattering (Mie Theory) |
| Particle Size Range | 0.10–25.0 µm (configurable channels) |
| Channel Count | 20 user-selectable size bins |
| Counting Accuracy | ≤±30% (per ISO 21501-4) |
| Concentration Accuracy | ≤±30% |
| Repeatability | ≤±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Flow Rate Options | 2.83, 28.3, 50, or 100 L/min |
| Sampling Time | 60 s default |
| Display | 10.0-inch industrial TFT-LCD with full-view angle |
| Data Storage | ≥10,000 test records (expandable via USB/SD) |
| Environmental Sensors | Integrated temperature (−40 to +120 °C), relative humidity (0–100% RH), dew point |
| Gas Detection Capability | Optional 1–3-channel electrochemical or NDIR sensors (e.g., CO, HCHO) |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE, 21 CFR Part 11 (audit trail, electronic signatures, role-based access) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤90% RH non-condensing |
| Protection | Overvoltage, overcharge, short-circuit, ESD & EMI shielding |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DPC-2623 |
| Price | USD 16,800 (FOB) |
| Detection Principle | Light Scattering (Laser Diode, 650 nm) |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Particle Size Channels | Up to 20 configurable channels |
| Minimum Detectable Size | 0.10 µm |
| Maximum Detectable Size | 25.0 µm |
| Size Resolution Options | Six preconfigured channel sets (A–F) |
| Counting Accuracy | ≤ ±30% (per ISO 21501-4 & JJF 1190) |
| Repeatability | ≤ ±10% FS |
| Coincidence Loss | <5% at 2×10⁶ particles/ft³ |
| Environmental Sensors | Integrated temperature/humidity (–40 to 120 °C, 0–100% RH), optional differential pressure & toxic gas (CO, HCHO) modules |
| Display | 3.45″ industrial-grade TFT LCD with full viewing angle |
| Data Storage | Local capacity ≥10,000 records |
| Power | Rechargeable polymer battery (4100 mAh), optional extended runtime |
| Protection Rating | IP66 |
| Explosion Protection | Ex d II CT4 (intrinsically safe design) |
| Compliance | ISO 14644-1:2015, ISO 21501-4:2018, JJF 1190–2008, GMP Annex 1 (2022), FDA 21 CFR Part 11 (audit trail enabled in firmware v3.2+) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PGS-OC1 |
| Price | USD 3,950 (FOB) |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Range | 0.0–10 / 100 / 1000 ppm O₂ (selectable) |
| Accuracy | ≤ ±2% FS |
| Sample Flow Rate | 400 ± 10 mL/min |
| Inlet Pressure Range | 0.05–0.5 MPa |
| Response Time (T₉₀) | ≤ 60 s |
| Display | 128×64 OLED, monochrome, high-brightness |
| Data Storage | 3200 records with trend curve |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% (charger) |
| Built-in Sampling Pump | Yes |
| Operating Temperature | –5 °C to +45 °C |
| Operating Humidity | ≤ 90% RH (non-condensing) |
| Alarm Output | User-configurable threshold (factory default: 5 ppm O₂) |
| Compliance | Designed for ISO 8573-3, ASTM D6299, and GLP-aligned field verification workflows |
| Brand | PULUODY |
|---|---|
| Model | PLD-601 |
| Origin | Shaanxi, China |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Principle | Light Obscuration (LO) per USP <788>, EP 2.9.19, and ChP 0903 |
| Measurement Range | 1–500 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable size channels (down to 0.01 µm resolution) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Accuracy | ±3% typical (per ChP 2020) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | NIST-traceable latex spheres, ISO 21501-4, JJG 1061 |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signature, 5-level user权限 management |
| Operating Interface | Touchscreen + optional wireless keyboard/mouse |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Regulatory Alignment | Compliant with ChP 2015/2020, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 4406, ISO 11171, NAS 1638, SAE AS4059, MIL-STD-1246, ASTM D6786, GB/T 18854, DL/T 432, and more |
| Brand | PULUODY |
|---|---|
| Model | PLD-6010 |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Counting |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Resolution | 1000 customizable channels (down to 0.01 µm bin width) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow control system |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Temperature Range (fluid) | 0–80 °C |
| Environmental Operating Temp | −15–50 °C |
| Compliance | FDA 21 CFR Part 11 (audit trail, e-signature, 5-level user权限, data backup/recovery, power-fail protection), GLP/GMP-ready |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Regulatory Alignment | ChP 2015/2020 <0903>, USP <788>/<789>/<797>, EP 10.0/9.0, BP 2019, JP 17, WHO IntPh IV, YBB 00272004-2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406, ASTM D6786 |
| Brand | PULUODY |
|---|---|
| Model | PLD-601W |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Measurement Range | 1–450 µm (customizable sub-ranges: 1–100 µm or 4–70 µm(c) |
| Channel Count | 1000 adjustable channels |
| Sampling Flow Rate | 5–150 mL/min |
| Cleaning Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | 0–50 °C |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Sampling Precision | <±1% |
| Compliance Standards | ChP 0903 (2015/2020), USP <788>, <789>, <797>, EP 10.0, BP 2019, YBB00272004-2015, ISO 21501-4, ISO 4406, NAS 1638, GB/T 11446.9-2013, JJG 1061 |
| Software | V8.9 Integrated Analysis Suite (PC & embedded touchscreen) with 5-level user权限 management, audit trail, electronic signature, and 21 CFR Part 11 compliance |
| Data Integrity | Auto-backup, restore, power-fail recovery, GLP/GMP-ready reporting |
| Brand | PULUODY |
|---|---|
| Model | PLD-FX-801 |
| Detection Principle | Dual-mode (Light Obscuration + Light Scattering) |
| Sensor Generation | 8th-generation dual-laser collimated beam sensor |
| Measuring Range | 0.5–100.0 µm |
| Customizable Channels | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision metering pump |
| Output | 4–20 mA analog interface with configurable alarm |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Compliance Support | GLP/GMP audit trail, FDA 21 CFR Part 11 ready (optional configuration) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PLD-GS2 |
| Type | Orbital Shaker |
| Display | LED Digital Speed & Timer |
| Drive Mechanism | Eccentric Cam with Belt-Driven Motion |
| Platform Size | 300 × 300 mm (standard) |
| Speed Range | 30–300 rpm |
| Speed Accuracy | ±1 rpm |
| Timer Range | 1–999 min |
| Platform Load Capacity | ≤5 kg |
| Noise Level | ≤50 dB(A) |
| Construction | Powder-Coated Steel Frame with Stainless Steel Platform |
| Compliance | CE, ISO 9001, GB/T 12803–2021 (Laboratory Equipment – Orbital Shakers) |
| Brand | PULUODY |
|---|---|
| Model | PLD-GS2 |
| Drive Type | Orbital (Circular) Motion |
| Speed Range | 40–350 rpm |
| Display | Digital LED Speed & Timer |
| Timer Range | 1–10 h or Continuous Operation |
| Platform Dimensions | 360 × 360 mm |
| Oscillation Amplitude | 20 mm (customizable eccentricity available) |
| Max Load Capacity | 8 kg |
| Motor Power | 32 W |
| Input Voltage | AC 100–220 V, 50/60 Hz |
| Platform Material | Stainless Steel with Adjustable Spring-Loaded or Belt-Type Clamps (custom fixtures supported) |
| Noise Level | <55 dB(A) |
| Dimensions (L×W×H) | 450 × 390 × 110 mm |
| Net Weight | 11 kg |
| Compliance | CE-marked design principles |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-GS2 |
| Drive Type | Belt-driven orbital motion |
| Display | Digital speed & timer display |
| Speed Range | 30–300 rpm (adjustable) |
| Timer Range | 1–999 minutes |
| Platform Size | 300 × 300 mm |
| Load Capacity | ≤5 kg |
| Operating Noise | <50 dB(A) |
| Construction | Stainless steel platform with corrosion-resistant frame |
| Clamp System | Stainless steel spring clamps (customizable for vials, flasks, tubes, microplates) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Measurement Principle | Digital Microscopy + Automated Image Analysis |
| Particle Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Maximum Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm (excluding sample preparation effects) |
| Repeatability Error | <5% (excluding sample preparation effects) |
| CCD Camera | 5–18 MP |
| Particle Segmentation Speed | <1 s per frame |
| Segmentation Success Rate | >93% |
| Software Platform | Windows 10 |
| Interface | RS232 or USB |
| Measurement Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Classification Resolution | >95% |
| Compliance Support | ISO 4406, NAS 1638, ISO 16232, VDA 19.1, SAE AS4059, ASTM F3217 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-MPCS2.0 |
| Price | USD 50,000 (FOB) |
| Measurement Principle | Brightfield Microscopy + Digital Image Analysis |
| Compliance | Chinese Pharmacopoeia ChP 0903 Method 2 (Microscopic Particle Counting), USP <788>, USP <789>, EP 2.9.19, ISO 21501-4, ISO 21510, GB/T 11446.9-2013 |
| Particle Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Resolution | 0.1 µm |
| Repeatability Error | <5% (excluding sample preparation variability) |
| CCD Sensor | 3 MP monochrome digital camera |
| Calibration Traceability | Northwest Metrology & Testing Center (Civil Products) |
| Software Platform | Windows 2000/XP compatible |
| Interface | RS-232 or USB 2.0 |
| Automatic Field Stitching | Full membrane scan with seamless mosaic generation |
| Particle Segmentation Speed | <1 s per image |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% typical (ChP 2020 reference calibration) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Resolution Performance | >95% (ChP 2020), <10% false-negative rate (USP/ISO 21501-4) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 72,500 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Detection Range | 0.5–5.0 µm (standard) |
| Customizable | 1–100 µm or 4–70 µm(c) |
| Extended Sensitivity | Down to 0.1 µm(c) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Software | PULUODY V8.3 Analysis & Calibration Separation Architecture (PC & Touchscreen Integrated) |
| Interface | 4–20 mA Analog Output, Alarm Relay (Configurable) |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Data Output | Particle Count per mL & ISO 4406 / NAS 1638 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software architecture |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.065–0.2 µm and 0.1–0.5 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Compliance | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-2, JJG 1061 |
| Output Interface | 4–20 mA analog output with configurable alarm thresholds |
| Data Acquisition | iPad-integrated wireless acquisition & PC-based V8.3 Analysis Software Suite |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Domain | Semiconductor photoresist, ultrapure water (UPW), electronic cleaning agents, silicon wafers, flat-panel glass, microelectronics components, nanofiltration, and polymer solutions |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,500 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + High-Accuracy Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368-2018 |
| Measurement Range | 0.1–0.5 µm and 0.1–1.0 µm (standard) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with programmable alarm thresholds |
| Data Acquisition | Integrated iPad-compatible wireless data capture |
| Software | PULUODY V8.3 Particle Analysis & Calibration Separation Platform (PC + embedded GUI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2+ |
| Price | USD 67,000 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 1–450 µm (standard), 0.03–3000 µm (optional) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020, GB/T 18854, JJG 1061 |
| Sensor Technology | 8th-Generation Dual-Laser Optical Particle Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical (count), ±1% volumetric delivery |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Data Output | 4–20 mA analog interface,超标 alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + iPad-compatible) |
| Compliance | FDA 21 CFR Part 11 ready (audit trail, electronic signature support), GLP/GMP-aligned workflow design |
| Display & Control | 10.1" capacitive touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50/60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PMT-2DR |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 0.5–20.0 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Obscuration Sensor |
| Sampling Method | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Data Output | 4–20 mA analog interface with configurable particle concentration alarm |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & tablet-compatible) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2G |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–0.5 µm (standard) |
| Resolution | 0.1 µm(c) minimum detectable size |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable particle concentration alarm |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Supports GLP/GMP audit trails, ASTM F3290 (for semiconductor process liquids), USP <788> & <789> (for insoluble particle assessment in polymer solutions) |