Other General Analytical Instruments
Filter
Showing 31–60 of 382 results
| [Brand | AMS Alliance |
|---|---|
| Origin | USA |
| Model | Smartchem 600 |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 (with refrigeration) |
| Wavelength Range | 340–1100 nm |
| Cuvette Path Length | 10 mm (6 mm optional) |
| Detection Principle | Dual-beam, dual-wavelength photometry |
| Maximum Throughput | 600 samples/hour |
| Reaction Disc Capacity | 85 reusable cuvettes |
| Temperature Control | 37 °C ± 0.3 °C |
| Linear Absorbance Range | 0.00001–4.2 Abs |
| Resolution | 0.00001 Abs |
| Minimum Reaction Volume | 180 µL |
| Compliance | ISO, AOAC, US EPA, AFNOR, COFRAC, BATF] |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem140 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 330–840 nm |
| Sample Capacity | 64 positions |
| Reagent Positions | 24 + 10 |
| Cuvette Path Length | 6 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem200 |
| Product Type | Automated Discrete Analyzer |
| Wavelength Range | 420–880 nm |
| Sample Capacity | 126 positions |
| Reagent Positions | 10 (expandable to 28) |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Tungsten Lamp (2000 h lifetime) |
| Measurement Speed | Up to 200 tests/hour (per method) |
| Minimum Reaction Volume | 300 µL |
| Absorbance Range | 0.001–2.500 Abs |
| Absorbance Resolution | 0.0001 Abs |
| Thermostat Accuracy | 37 °C ± 0.3 °C |
| Dimensions (H×W×L) | 420 × 650 × 1000 mm |
| Weight | 43 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 12 fixed wavelengths from 340 to 880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Path Length | 6 mm or 10 mm |
| Light Source | High-stability LED |
| Brand | AMS |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FUTURA Segmented Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 240–720 positions |
| Reagent Positions | 5–30 |
| Flow Cell Path Length | 5–500 mm |
| Light Source | Tungsten-Halogen Lamp |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smartchem 300 |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smartchem |
| Pricing | Upon Request |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-1000 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 162 positions |
| Reagent Positions | 3–8 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SUPR-CM |
| Price Range | USD 135,000 – 270,000 |
| Brand | Alpha MOS |
|---|---|
| Origin | France |
| Model | ASTREE LS16/48 |
| Type | Taste Analysis System |
| Sensor Technology | ChemFET-based Potentiometric Array |
| Sample Throughput | 1 sample per 3 minutes (with auto-sampler) |
| Configuration Options | 16- or 48-channel sensor array |
| Compliance | Designed for GLP/GMP-aligned laboratories, supports audit-trail-capable data management per FDA 21 CFR Part 11 requirements |
| Brand | Atik |
|---|---|
| Sensor Resolution | 1620 × 1220 pixels |
| Sensor Type | Monochrome back-illuminated CCD |
| Pixel Size | 9.0 µm × 9.0 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | <10 e⁻ (at 0.1 MHz) |
| Dark Current | <0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TE) to −20 °C below ambient |
| Interface | USB 2.0 |
| Shutter | Electronic rolling shutter |
| Compliance | CE, RoHS, FCC Class B |
| Software Support | ASCOM, DirectShow, LabVIEW, MATLAB, Python (via SDK) |
| Brand | Atik Instruments |
|---|---|
| Sensor Resolution | 1460 × 1932 pixels |
| Sensor Type | Monochrome Back-Illuminated CCD |
| Pixel Size | 6.45 µm × 6.45 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | < 10 e⁻ (at slow readout) |
| Dark Current | < 0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TEC), regulated to ΔT ≤ −45 °C below ambient |
| Interface | USB 2.0 with proprietary low-noise controller |
| Shutter | Electronic Rolling Shutter (global reset capable) |
| Compliance | CE, RoHS, FCC Class B |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | AutoChem 1100 |
| Price Range | USD 28,000–70,000 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 60 or 96 positions |
| Reagent Positions | 27 (Peltier-cooled) |
| Cuvette Path Length | 10 mm |
| Light Source | 12 V / 20 W Halogen Lamp with UV-Visible Output |
| Detection Speed | Up to 200 determinations per hour |
| Injector Precision | ±0.5% (5–1000 µL), Resolution: 0.1 µL |
| Reaction Disc Temperature Control | ±0.1 °C |
| Cuvette Temperature Control | ±0.1 °C |
| Photometric Accuracy | ±1% OD (0–2.5 OD) |
| Linearity | <0.5% deviation |
| Noise | <±0.002 Abs (at 340 nm, 2.5 OD) |
| Detection Modes | Endpoint, Differential, Timed, and Kinetic |
| Data Interface | RS-232 / USB |
| Operating Environment | 15–35 °C, 20–80% RH |
| Power Supply | 220 V AC |
| Origin | Norway |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APPS |
| Pricing | Available Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A1TDS-20A |
| Price | USD 21,800 (approx. based on ¥156,000 at 7.15 exchange rate) |
| Sample Capacity | 20 positions |
| Cold Trap Range | −35 °C to ambient |
| Primary Desorption Temp | up to 450 °C |
| Secondary Desorption Temp | up to 450 °C |
| Valve & Transfer Line Temp | up to 300 °C |
| Temperature Resolution | 1 °C |
| Temp Stability | ±0.5 °C |
| Recovery Rate | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Carrier Gas Flow Control | 0–100 mL/min (purge/flush), 0–160 mL/min (simulated sampling) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Interface | Motorized 6-port valve |
| Power Supply | 24 V DC for transfer line |
| Dimensions | 350 × 450 × 510 mm (W × D × H) |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Model | AAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (continuously adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation, GLP/GMP-ready audit trail via software logging |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AeTDS-20A |
| Price | USD 21,800 (FOB Beijing) |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BFAHS-20A Plus |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitation Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (up to 300 °C optional) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Inert Flow Path | Deactivated fused-silica and stainless-steel tubing |
| Interface | USB |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AHS-20A Plus |
| Sample Capacity | 20-position |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Size Compatibility | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (100 ppm ethanol in water) |
| Interface | USB |
| Valve Type | High-inertness 6-port valve with heated connection point |
| Transport Lines | Deactivated fused-silica capillary tubing |
| Drive Mechanism | Motor-driven (no external gas required) |
| Compliance | ASTM D3792, ISO 11843-2, USP <467>, EPA Method 502.2, 524.2, 8240, 8260] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Model | AHS-20A Plus |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Oven Temperature Range | 40–220 °C (extendable to 300 °C on request), ±0.5 °C stability, 0.5% accuracy |
| Valve & Transfer Line Temperature Range | 40–220 °C (extendable to 300 °C), ±0.5 °C stability |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| Rinse Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication, GC trigger synchronization, external event input/output |
| Sample Handling | Motor-driven, gas-free operation |
| System Compliance | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSA-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC optional |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Backflush Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB |
| Sample Handling | Liquid and solid matrices |
| Inert Flow Path | Deactivated fused-silica tubing and high-inertness valve components |
| Drive Mechanism | Motor-driven (no external gas required) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSC-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSD-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressure Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Sample Positions | 20 |
| Simultaneous Heating Zones | 1 or 2 |
| RSD (Ethanol in Water, 100 ppm) | <1.0% |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | AHSE-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Sizes | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitation Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Oven Temperature Range | 40–220 °C (optional up to 300 °C), accuracy ±1 °C, stability <±0.5 °C |
| Valve & Transfer Line Temp Range | 40–220 °C (optional up to 300 °C), same accuracy/stability |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB, GC-trigger synchronization, external event input/output |
| Compliance | Compatible with ASTM D6866, ISO 11843, USP <467>, and GLP/GMP workflows requiring audit-trail-capable instrument control |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSF-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Pressurization Time | 0–999 s |
| Purge/Clean Time | 0–30 min |
| Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5/2/5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50/100 mL) |
| Sample Positions | 20 |
| Simultaneous Heating | 1 or 2 vials |
| RSD | <1.0% (100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (software-controlled audit trail optional) |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSG-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Cleaning Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (customizable: 0.5/2/5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50/100 mL) |
| Sample Positions | 20 |
| Simultaneously Heated Samples | 1 or 2 |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (continuously adjustable) |
| Interface | USB |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-20A |
| Configuration | Fully Automated Two-Stage Thermal Desorption with Electronic Cryogenic Cold Trap (−35 °C) |
| Sample Capacity | 20-Position Carousel |
| Temperature Control Precision | ±0.5 °C |
| Detection Compatibility | Universal Interface for GC & GC-MS Systems (Including Agilent, Thermo Fisher, Shimadzu, PerkinElmer) |
| Compliance | Designed to meet HJ 644–2013, HJ 583–2010, HJ 734–2014, GB/T 18883–2002, GB 50325–2010, and HJ/T 400–2007 requirements |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-20A |
| Cold Trap Range | −35 °C to Ambient |
| Primary Heating Zones | 4 Independent Zones (Desorption 1, Valve, Transfer Line, Desorption 2) |
| Temperature Resolution | 1 °C |
| Temp Control Accuracy | < ±0.5 °C |
| Sample Capacity | 20 Positions |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Dual-Stage Desorption | Yes (with Electronic Cooling & Rapid Re-Desorption) |
| Max Ramp Rate | >3000 °C/min |
| Desorption Recovery | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Purge/Backflush Flow | 0–100 mL/min (adjustable) |
| Simulated Sampling Flow | 0–160 mL/min |
| Dimensions | 350 × 450 × 510 mm |
| Weight | ~40 kg] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | ATDS-20A |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | ATDS-20A |
| Pricing | Upon Request |
| Sample Capacity | 20 positions |
| Cold Trap Temperature Range | −35 °C to ambient |
| Primary Desorption Temp | RT–450 °C |
| Secondary Desorption Temp | RT–450 °C |
| Valve & Transfer Line Temp | RT–300 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene in 0.05 μg methanol) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Sampling Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Carrier Gas Flow (Purge/Backflush) | 0–100 mL/min |
| Simulated Sampling Flow | 0–160 mL/min |
| Heating Ramp Rate (2nd Stage) | >3000 °C/min |
| Dimensions (L×W×H) | 350 × 450 × 510 mm |
| Weight | ~40 kg |