Packaging Industry Specialized Instruments
Filter
Showing 1–30 of 188 results
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | MAP-PAK Combi |
| Measurement Range | 0.1–100% O₂ and CO₂ |
| Accuracy | ±1% of reading |
| Response Time | <10 s |
| Data Storage Capacity | Up to 5,000 records |
| Display | Backlit LCD |
| Power | Rechargeable battery (4 units) + AC adapter |
| Compliance | CE-marked, ISO 9001-manufactured instrumentation |
| Software | MP Download Software (Windows-compatible) |
| Optional Accessory | Portable thermal printer |
| Language Support | Multilingual UI (English, French, German, Spanish, Italian, Chinese) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8205 |
| Power Supply | AC 220 V |
| Power Consumption | 250 W |
| Load on Specimen | 26.7 ± 0.2 N |
| Rubber Wheel Rotational Speed | 76 ± 2 rpm |
| Abrasive Wheel Rotational Speed | 34 ± 1 rpm |
| Adjustable Inclination Angle Between Wheels | 15° or 25° |
| Dimensions (L×W×H) | 600 × 480 × 400 mm |
| Net Weight | 60 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | SealBio-1 |
| Temperature Range | Ambient to 200 °C (±1 °C accuracy) |
| Temperature Adjustment Increment | 1 °C |
| Preheating Time | 5 min |
| Cycle Time | <20 s per plate |
| Sealing Time Range | 0.5–9.9 s (0.1 s increment) |
| Compatible Plate Heights | 3–62 mm |
| Plate Standards | ANSI/SBS-compliant 12-, 24-, 48-, 96-, and 384-well plates (PCR, ELISA, deep-well, cell culture) |
| Film Width | 78 mm |
| Film Types | Piercable film, aluminum foil film, high-strength thermal seal film |
| Loading Method | Automatic pre-loading |
| Integrated Air Source | Yes |
| Interface | USB-B + Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Max Power | 300 W |
| Display | 7-inch capacitive touchscreen (1024 × 600 resolution) |
| Safety Features | Plate presence detection, film presence detection, standby mode |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | SealBio-1 Automated Microplate Heat Sealer |
| Temperature Range | Ambient to 200 °C (±1 °C accuracy) |
| Temperature Adjustment | 1 °C increments |
| Preheat Time | 5 min |
| Cycle Time | <20 s per plate |
| Sealing Time Adjustment | 0.5–9.9 s (0.1 s resolution) |
| Compatible Plate Heights | 3–62 mm |
| Plate Standards | ANSI/SBS-compliant (12-, 24-, 48-, 96-, and 384-well formats) |
| Roll Film Width | 78 mm |
| Film Types | Piercable film, aluminum foil, high-strength thermal sealing film |
| Loading | Automatic pre-load roll mechanism |
| Integrated Air Source | Yes (no external compressor required) |
| Interface | 7″ capacitive touchscreen (1024×600), USB-B port, Ethernet port |
| Power | AC 100–240 V, 50/60 Hz |
| Max Power Consumption | 300 W |
| Safety Features | Plate presence detection, film presence detection, standby mode (low-power idle) |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS3 |
| Quotation | Upon Request |
| Sampling Capacity | 0.5 L |
| Standard Sampling Depth | 7.62 m (extendable) |
| Minimum Well Casing ID | 5.08 cm |
| Body Material | Stainless Steel |
| Sample Tube Material | Fluoropolymer |
| Valve Material | Fluoropolymer |
| Overflow Cap Material | Fluoropolymer |
| Included Components | Measured cable, cable controller, T-handle actuator, cable control accessories, fluoropolymer sample tube, fluoropolymer-valved top cap, overflow cap, two fluoropolymer tube caps |
| Brand | Asahi Seiko |
|---|---|
| Origin | Japan |
| Model | EG01-6-1MR |
| Test Principle | Gurley-type differential pressure method |
| Measurement Units | Gurley seconds (s), air permeability [µm/(Pa·s)] |
| Accuracy | ±2% |
| Measurement Time | Up to 50× faster than conventional constant-volume methods |
| Pressure Source | 0.25 MPa (2.5 kgf/cm²) |
| Display | Red LED digital display |
| Timer Range | 0–999 s |
| Interface | RS-232C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 520 × 520 mm |
| Net Weight | 20 kg |
| Compliance | JIS P 8117:2009 |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Model | 00100112 |
| Load Cell Capacity | 2000 g |
| Slider Dimensions | 63.5 × 63.5 mm |
| Standard Slider Mass | 200 g |
| Test Speed Range | 1–900 mm/min |
| Total Slider Travel | 400 mm |
| Test Area | 200 × 400 mm |
| Temperature Control Option | 0–120 °C |
| Data Output | USB interface |
| Compliance Standards | ASTM D1894 (Method B), ISO 8295, DIN 53375 |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckMate 4 SV |
| Origin | Denmark |
| Gas Measurement | O₂ or O₂ + CO₂ |
| Principle | Zirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂) |
| Sampling Method | Non-invasive optical probe or minimally invasive needle-penetration |
| Minimum Sample Volume | None |
| Resolution | 0.001% |
| Accuracy | ±0.02% |
| Compliance | Designed for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture |
| User Interface | Multi-language capacitive touchscreen (10 languages) |
| Data Management | On-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckPoint 4 |
| Origin | Denmark |
| Detection Gases | O₂ and CO₂ (selectable single or dual) |
| Measurement Principle | Electrochemical (O₂), Infrared (CO₂) |
| Portability | Handheld, battery-powered |
| Interface | Capacitive touchscreen with 10 language options |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned quality control environments |
| Power | Rechargeable Li-ion battery with rugged charging port |
| Accessories | Standard low-cost hypodermic needle probe (22G), optional protective boot |
| Auto-shutdown | Yes, energy-saving mode |
| Gas flow alarm | Visual and audible alert |
| Certifications | CE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines) |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | Lippke 5000 |
| Test Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Volume Capacity | 0–90,000 mL |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Brand | DERUI TESTING |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DR-ZB206A |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Accuracy | ±0.1 s |
| Measurement Range | 0–9999 s (three ranges: 1–15 s, 15–300 s, 300–9999 s) |
| Test Area | 10.00 ±0.05 cm² |
| Timing Accuracy | ≤±1 s over 1000 s |
| Vacuum Chamber Volume | Large chamber: 380 ±1 mL |
| Small chamber | 38 ±1 mL |
| Vacuum Setpoint Range | Range I & II: 50.66–48.00 kPa |
| Range III | 50.66–29.33 kPa |
| Air Ingress Volume | 10.00 ±0.20 mL (large chamber), 1.00 ±0.05 mL (small chamber) for pressure drop from 50.66 kPa to 48.00 kPa |
| Applied Pressure | 100 kPa ±2 kPa |
| Display | 7-inch color TFT touch screen with bilingual (Chinese/English) menu interface |
| Operating Environment | 5–35 °C, RH ≤85% |
| Dimensions | 318 × 362 × 518 mm |
| Weight | 47 kg |
| Compliance | GB/T 456, ISO 8791-2, TAPPI T479, ASTM D5263 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-104 |
| Price | USD 4,200 (FOB) |
| Standard Compliance | ISO 3036, GB/T 2679.7–2005 |
| Measurement Unit | Joules (J) |
| Display | LCD with Chinese GUI |
| Output | Thermal line printer |
| Control System | Microprocessor-based embedded control |
| Sample Clamping | Spring-loaded dual-plate pneumatic-free mechanical clamp |
| Safety Mechanism | Interlocked release handle with automatic reset |
| Energy Range | 0.1–10 J (typical for corrugated board testing) |
| Resolution | 0.01 J |
| Repeatability | ≤±1.5% RSD (per ISO 3036 verification protocol) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | DRK106 Horizontal |
| Price Range | USD 7,000 – 14,000 |
| Stiffness Measurement Range (Bending Force) | 15–300 mN |
| Resolution | 0.1 mN |
| Accuracy | ±0.6 mN (≤50 mN), ±1% (>50 mN) |
| Repeatability | ≤1% |
| Bending Length Options | (50±0.1) mm, (25±0.1) mm, (10±0.1) mm |
| Bending Angle | 15°±0.3°, 90°±0.3° |
| Bending Rate | 200°±20°/min (adjustable) |
| Crease Stiffness Specimen Size | 38×36 mm |
| Sheet Stiffness Specimen Size | 70×38 mm |
| Operating Temperature | 20°C±10°C |
| Power Supply | AC 220 V±5%, 50 Hz, Grounded |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DRK108 |
| Price | ¥50,000 CNY |
| Standard Compliance | ISO 1974, GB/T 455.1, GB/T 450–2002, GB/T 10739–2002 |
| Measuring Range | (10–13,000) mN |
| Resolution | 10 mN |
| Accuracy | ±1% of reading (20–80% of full scale), ±0.5% FS (outside range) |
| Repeatability | <1% (20–80% FS), <0.5% FS (outside range) |
| Tear Arm Length | (104 ± 1) mm |
| Initial Tear Angle | 27.5° ± 0.5° |
| Tear Distance | (43 ± 0.5) mm |
| Clamp Face Dimensions | 25 × 15 mm |
| Clamp Spacing | (2.8 ± 0.3) mm |
| Specimen Size | (63 ± 0.5) mm × (50 ± 2) mm |
| Operating Temperature | 20 ± 10 °C |
| Relative Humidity | ≤80% RH |
| Dimensions | 460 × 400 × 400 mm |
| Weight | 30 kg |
| Power Supply | AC 220 V ± 5%, 50 Hz |
| Data Acquisition | 24-bit high-precision ADC (resolution up to 1/10,000,000) |
| Display & Interface | Bilingual Chinese–English menu |
| Output | Integrated thermal printer (modular, fast print speed, easy paper replacement) |
| Statistical Output | Mean, standard deviation, coefficient of variation |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | DRK109 Manual Touchscreen |
| Price | USD 7,000 (FOB Qingdao) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK109 |
| Measurement Range | 250–6000 kPa |
| Clamp Force | >690 kPa |
| Clamping Ring Diameter | φ31.5 ± 0.05 mm |
| Hydraulic System Max Pressure | 6000 kPa |
| Accuracy | ±0.5% F.S. |
| Resolution | 0.1 kPa |
| Compliance | ISO 2759, GB/T 6545, GB/T 454, QB/T 1057, GB 1539 |
| Brand | Drick |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | DRK120 |
| Price | USD 6,700 (FOB Shanghai) |
| Measurement Principle | Eddy Current |
| Compliance | GB/T 4957–2003 (Non-magnetic Coatings on Non-ferrous Substrates) |
| Measuring Range | 10–1000 Å |
| Minimum Sample Area | ≥100 mm × 200 mm |
| Resolution | 10 Å |
| Accuracy | ≤ ±3% of Full Scale |
| Repeatability | ≤30 Å (at same point) |
| Application Scope | Vacuum-deposited Al coatings on PET, OPP, CPP, BOPP, and metallized paper substrates |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK127 |
| Load Range | 0–5 N (Accuracy Class 0.5) |
| Traverse Distance | 70 mm or 140 mm |
| Standard Sled Mass | 200 g |
| Test Speed | 150 mm/min |
| Ambient Operating Conditions | 15–30 °C, 20–80 % RH |
| Dimensions (L×W×H) | 470 × 300 × 190 mm |
| Net Weight | 20 kg |
| Compliance | GB 10006, GB/T 17200, ISO 8295, ASTM D1894, TAPPI T816 |
| Key | Brand: NOSELAB ATS |
|---|---|
| Origin | Italy |
| Type | Import Instrument |
| Standard Compliance | ASTM D1709 Methods A & B |
| Drop Height Range | 650–1530 mm |
| Clamp Ring Diameter (Outer) | 127 mm |
| Inner Ring Diameter | 125 mm ± 2 mm |
| Actuation | Electromagnetic Release |
| Clamping | Pneumatic Dual-Ring Fixture |
| Safety Enclosure | Acrylic Cylindrical Guard with Dart Recovery System |
| Leveling | Adjustable Horizontal Feet and Vertical Position Control |
| Calibration Tool | Conical Metal Plumb Bob with Suspension Cord and Magnetic Tip |
| Accessories Included | Standard Dart Assembly, Weight Sets, and Optional Test Fixtures |
| Brand | ExtraSolution |
|---|---|
| Origin | Italy |
| Model | CarboPack BT |
| Application Domain | Packaging Industry – CO₂ Transmission Rate (CO₂TR) Measurement |
| Detection Principle | Non-Dispersive Infrared (NDIR) with Dual-Wavelength Subsystem |
| Temperature Control Range | Ambient to 60 °C (heating/cooling system integrated) |
| Humidity Control Capability | Optional RH-controlled testing up to 90% RH |
| Measurement Time per Sample | < 60 minutes |
| Detection Limit | Sub-ppm CO₂ flux resolution |
| Compliance Context | Designed for ASTM F2622, ISO 15105-2, and EU Regulation (EC) No. 1935/2004–compliant packaging validation workflows |
| Brand | ExtraSolution |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PackPerm |
| Pricing | Available Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MIT-Fold |
| Pricing | Available Upon Request |
| Measurement Range | 1–60,000 folds |
| Fold Count Log Scale | 0–4.78 (log₁₀) |
| Tension Adjustment Range | 4.9–14.7 N |
| Folding Angle | ±135° ±2° (left/right) |
| Folding Frequency | 175 ±10 cycles/min |
| Fold Head Slit Widths | 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm (standard: 0.50 mm & 0.75 mm supplied |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 330 × 250 × 400 mm |
| Net Weight | ~37 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | N500 Gas Permeability Tester |
| Measurement Range | 0.02–50,000 cm³/m²·day·0.1 MPa (expandable to 600,000 cm³/m²·day·0.1 MPa) |
| Measurement Accuracy | ±0.01 cm³/m²·day·0.1 MPa |
| Temperature Range | 5–50 °C |
| Temperature Control Accuracy | ±0.01 °C |
| Humidity Range | 0 %RH (5–100 %RH optional) |
| Humidity Control Accuracy | ±2 %RH |
| Vacuum Precision | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Test Gases | O₂, CO₂, N₂ |
| Max Sample Thickness | ≤2 mm |
| Effective Test Area | 50.24 cm² (Φ80 mm) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBPI W413 2.0 |
| Quotation | Upon Request |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per test cycle |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), ≥0.1 MPa supply pressure, 5–100 mL/min flow rate |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GBPI Y310 2.0 |
| Price | USD 54,500 (FOB Guangzhou) |
| Test Principle | Coulometric Oxygen Sensor Method |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B, YBB 00082003 |
| Measurement Range | 0.05–1000 cm³/(m²·24 h) (up to 260,000 cm³/(m²·24 h) with auxiliary mask) |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 independent test chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y310-3 |
| Price Range | USD 14,000 – 72,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional) |
| Humidity Control | 0%RH (dry), 30–90%RH, 100%RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDP-C |
| Pricing | Available Upon Request |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GT-6011-B |
| Pricing | Available Upon Request |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GT-6014-AS |
| Pricing | Upon Request |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GT-6023 |
| Pricing | Upon Request |