| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DRK-G100 |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | Wet Dispersion: 0.1–1000 µm |
| Dry Dispersion | 0.1–1000 µm |
| Repeatability | <1% (D50, certified NIST-traceable standard reference material per GB/T 19077–2016 / ISO 13320:2020) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | DRK-G100D |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Dry Mode) | 0.1–1000 µm |
| Repeatability | <1% RSD (verified against national standard reference material, D50) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | DRK-G100W |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Wet) | 0.1–1000 µm |
| Repeatability | <1% RSD (D50, certified NIST-traceable standard reference material) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory Instrument |
| Model | DRK-G200D |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Benchtop Laser Particle Size Analyzer |
| Measurement Range (Dry Mode) | 0.1–2000 µm |
| Repeatability | <1% RSD (verified with NIST-traceable standard reference material, D50) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DRK-G200W |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Wet) | 0.02–2000 µm |
| Repeatability | <1% RSD (D50, certified national standard reference material) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DRK-G202 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–800 µm (Full-range, No Sub-ranges) |
| Repeatability | ≤1% RSD (D50, certified NIST-traceable standard reference material) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DRK-G300 |
| Pricing | USD 42,000 (FOB Qingdao) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory-Grade Laser Particle Size Analyzer |
| Measurement Range | Wet Mode: 0.02–2600 µm |
| Dry Mode | 0.1–2600 µm |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DRK-G300 |
| Dispersion Method | Dry and Wet Dispersion |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | DRK-P501 |
| Pricing | USD 28,000 (FOB Qingdao) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1 µm – 1200 µm, Full-Range Single-Mode Operation |
| Brand | DT Instruments |
|---|---|
| Origin | USA |
| Model | DT-100 / DT-110 |
| Measurement Principle | Ultrasonic Attenuation Spectroscopy (UAS) |
| Particle Size Range | 5 nm – 1000 µm |
| Sample Concentration Range | 0.1–50% v/v (undiluted) |
| Operating Frequency Range | 1–100 MHz |
| Minimum Sample Volume (DT-110) | < 5 mL |
| Dispersion Media Compatibility | Aqueous, polar, and non-polar liquids |
| Data Management | Microsoft Access-based database |
| Calibration-Free Operation | Yes |
| Adjustable Transducer Gap | Yes |
| Compliance Context | Supports GLP/GMP-aligned workflows |
| Brand | DT Instruments |
|---|---|
| Origin | USA |
| Model | DT-300 / DT-310 |
| Measurement Principle | Electroacoustic (Colloid Vibration Current, CVI) |
| Zeta Potential Range | Unlimited (down to ±0.1 mV) |
| Sample Concentration | 0.1–50% v/v (no dilution required) |
| Minimum Sample Volume | 2 mL |
| Measurable Parameters | Zeta potential, dynamic electrophoretic mobility, Debye length, particle size distribution (via optional ultrasound attenuation spectroscopy), rheological properties (viscoelastic moduli), solid content, porosity |
| Software Platform | Microsoft Access-based database with audit trail capability |
| Optional Module | Automated titration system (DT-310 only) |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | DT (USA) |
|---|---|
| Origin | USA |
| Model | RUFUTO-871 |
| Measurement Range | 1–20 and 1–200 (dimensionless) |
| Accuracy | ±2% |
| Calibration | With deionized water or reference liquids of known permittivity |
| Probe Type | Open-ended coaxial probe |
| Sample Compatibility | Aqueous solutions, polar and non-polar organic solvents, solvent mixtures |
| Brand | DT (USA) |
|---|---|
| Origin | USA |
| Model | DT-1202 |
| Particle Size Range | 5 nm – 1000 µm |
| Zeta Potential Measurement Range | Unlimited (±0.1 mV accuracy) |
| Concentration Range | 0.1–50 vol% |
| pH Range | 0.5–13.5 |
| Conductivity Range | 0.0001–10 S/m |
| Temperature Range | <50 °C |
| Max. Viscosity | 20,000 cP |
| Frequency Range | 1–100 MHz |
| Minimum Sample Volume | 2 mL |
| Titration Resolution | 0.1 µL |
| Simultaneous Measurement | Particle Size + Zeta Potential in One Cell |
| Optional Modules | Rheology, pH, Conductivity, Temperature, Auto-Titration, Non-Aqueous Systems |
| Brand | DT Instruments |
|---|---|
| Origin | USA |
| Model | DT-330 |
| Measurement Principle | Electroacoustics (Colloid Vibration Current, CVI) & Electrophoretic Acoustics (ESA) |
| Sample Concentration Range | 0.1–50 vol% (no dilution required) |
| Minimum Sample Volume | 2 mL |
| Zeta Potential Range | No theoretical lower limit |
| Compatible Solvents | Aqueous, polar, and non-polar media |
| Porosity Measurement | Yes (via high-frequency conductivity probe) |
| Surface Zeta Potential on Porous Solids | Yes |
| Output Parameters | Dynamic electrophoretic mobility, Debye length, surface charge density, solid content, rheological properties |
| Compliance Context | Designed for GLP/GMP-aligned labs |
| Brand | DT (USA) |
|---|---|
| Origin | USA |
| Model | DT-600 |
| Measurement Principle | Ultrasonic Spectroscopy (1–100 MHz) |
| Sample Concentration Range | 0.1–50 vol% (no dilution required) |
| Viscosity Range | 0.5–100 cP (±3% accuracy) |
| Longitudinal Modulus (G*) Measurement | 1–100 MHz |
| Solvent Compatibility | Aqueous, polar, and non-polar media |
| Zeta Potential & Particle Size | Direct measurement in concentrated dispersions |
| Isoelectric Point (IEP) Determination | Model-independent, no Debye-Hückel or Smoluchowski approximation required |
| Titration Function | Integrated automated potentiometric titration module |
| Data Management | Microsoft Access-based local database with audit-ready export |
| Brand | DT (USA) |
|---|---|
| Origin | USA |
| Model | DT-700 |
| Measurement Range | 0–200 µS/m |
| Resolution | 1 µS/m |
| Accuracy | ±2% of reading |
| Probe Operating Temperature | −20 °C to +200 °C |
| Display | LCD |
| Interface | USB for external storage export |
| Form Factor | Portable handheld unit |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Air Sizer 200 |
| Sieve Diameter | 203 mm (8 in) |
| Sieving Range | 20 µm – 4 mm |
| Drive Mode | Air Jet Impingement |
| No. of Sieves | 1 |
| Rotational Speed (Nozzle) | 5–55 rpm |
| Sieving Time Display | Digital, 0:10–99:50 min:ss |
| Vacuum Pressure Range | 20–99 mbar |
| Power Supply | 100–240 V, 50–60 Hz, Single-Phase |
| Dimensions (W×H×D) | 450 × 235 × 435 mm |
| Net Weight | 16 kg |
| Ingress Protection | IP40 |
| Compliance | CE |
| Accessories Available | Pre-filter, Industrial Vacuum Unit |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | EFL300 |
| Drive Type | Electromagnetic |
| Sieving Motion | 3D Horizontal Circular |
| Max Sample Capacity | 6 kg |
| Sieve Diameter Options | 100 / 150 / 200 / 250 / 300 / 315 mm (8" / 12") |
| Max Stack Height | 450 mm |
| Sieve Holders | 6 full-height or 12 half-height sieves |
| Amplitude Range | 0–2 mm (10-step digital adjustment) |
| Vibration Frequency | 3000 rpm @ 50 Hz |
| Timer Range | 0:10–99:55 min (digital display) |
| Wet & Dry Sieving | Yes |
| Enclosure Rating | IP54 |
| Power Supply | Single-phase, region-specific voltage |
| Dimensions (W×D×H, excl. clamps) | 427 × 240 × — mm |
| Net Weight | 45 kg |
| Compliance | CE-marked |
| Mounting Options | Benchtop or Floor-standing |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Minor 200 |
| Drive Type | Electromagnetic |
| Max Sample Capacity | 4 kg |
| Sieve Diameter Compatibility | 100 mm, 200 mm, 8 inch |
| Max Sieves per Stack | 8 (full-height) or 16 (half-height) |
| Vibration Amplitude | 1.6 mm (fixed) |
| Vibration Frequency | 3000 cycles/min @ 50 Hz |
| Timer Range | 0–60 min (mechanical dial) or continuous mode ("I") |
| Power Supply | 230 V, 50 Hz / 115 V, 60 Hz, 300 VA |
| Dimensions (W×H×D) | 315 × 126 × 287 mm |
| Net Weight | 17 kg |
| Ingress Protection | IP54 |
| Compliance | CE |
| Enclosure Type | Benchtop |
| Fixation Method | Polymeric tension belt |
| Base Stability | Anti-vibration rubber feet |
| Particle Size Range | 38 µm – 125 mm |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | MINOR |
| Drive Type | Electromagnetic |
| Max Sample Capacity | 4 kg |
| Sieve Diameter Compatibility | 100 mm, 200 mm, 8 inch |
| Max Number of Sieves | 8 (full-height) or 16 (half-height) |
| Vibration Amplitude | 1.6 mm (fixed) |
| Vibration Frequency | 3000 rpm @ 50 Hz |
| Timer Range | 0–60 min (mechanical dial) or continuous mode ("I") |
| Operating Mode | Dry sieving only |
| Enclosure Rating | IP54 |
| Power Supply | 230 V, 50 Hz / 115 V, 60 Hz, 300 VA |
| Dimensions (W×H×D) | 315 × 126 × 287 mm |
| Net Weight | 17 kg |
| Compliance | CE-marked |
| Sieve Fixation | Polymeric tension belt system |
| Footing | Vibration-damping rubber feet |
| Height Clearance Requirement | ≤200 mm |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | OCTAGON 200 |
| Drive Type | Electromagnetic |
| Sieving Motion | 3D Oscillation |
| Max Sample Capacity | 3 kg |
| Sieve Capacity | 8 full-height (200 mm) or 18 half-height sieves |
| Amplitude Range | 0–3 mm (10-step digital adjustment) |
| Frequency | 3000 rpm @ 50 Hz |
| Timer Range | 0:10–99:59 min (digital display) |
| Intermittent Mode | Yes |
| Dry & Wet Sieving | Yes |
| Sieve Diameter Options | 100 mm, 200 mm (8 in) |
| Max Stack Height | 450 mm |
| Clamping System | Quick-action universal clamp |
| Vibration Isolation | Non-metallic springs + damping mounts |
| Enclosure Rating | IP54 |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz, 300 VA |
| Dimensions (W×H×D) | 418 × 232 × 435 mm |
| Net Weight | 43 kg |
| Compliance | CE, EN 61000-6-2/6-4, EN 61000-3-2/3-3 |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Octagon 200 |
| Drive Type | Electromagnetic |
| Sieve Diameter | 200 mm (8 in) |
| Max. Stack Height | 450 mm |
| Max. Sample Mass | 3 kg |
| Sieve Capacity | 8 full-height or 18 half-height sieves |
| Amplitude Range | 0–3 mm (10-step digital control) |
| Vibration Frequency | 3000 rpm @ 50 Hz |
| Timer Range | 0:10–99:59 min (digital display) |
| Operating Modes | Continuous or Interval Vibration |
| Wet & Dry Screening | Yes |
| Enclosure Rating | IP54 |
| Power Supply | 230 V, 50 Hz / 115 V, 60 Hz, 300 VA |
| Dimensions (W×H×D) | 418 × 435 × 232 mm |
| Net Weight | 43 kg |
| Compliance | BS 410, ISO 3310-1 & -2, ASTM E11, UK Kitemark certified |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | OCTAGON 200 |
| Principle | Electromagnetic 3D Vibration Sieving |
| Sieve Diameter | 200 mm (8 in) |
| Max. Sample Capacity | 3 kg |
| Sieve Stacks | up to 8 full-height or 18 half-height sieves |
| Amplitude Range | 0–3 mm (10-step digital control) |
| Vibration Frequency | 3000 rpm @ 50 Hz |
| Timer Range | 0:10–99:59 min (digital display) |
| Operating Modes | Continuous or Interval Vibration |
| Dry & Wet Sieving | Yes |
| IP Rating | IP54 |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz, 300 VA |
| Dimensions (W×H×D) | 418 × 435 × 232 mm |
| Net Weight | 43 kg |
| Compliance | CE |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Octagon 200CL |
| Drive Type | Electromagnetic |
| Sieving Motion | 3D (elliptical, horizontal, vertical components) |
| Max. Sample Mass | 3 kg |
| Sieve Capacity | 8 full-height 200 mm sieves or 18 half-height 200 mm sieves |
| Amplitude Range | 0–3 mm (digitally adjustable in 0.1 mm increments, closed-loop controlled) |
| Vibration Frequency | 3000 rpm @ 50 Hz |
| Timer Range | 0:10–99:59 min (digital display) |
| Intermittent Sieving Modes | 2 preset intervals |
| Dry & Wet Sieving | Supported |
| Sieve Diameter Options | 100 mm, 200 mm (8 inch) |
| Max. Stack Height | 450 mm |
| Clamping System | Quick-action precision clamp |
| Enclosure Rating | IP54 |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz, 300 VA |
| Dimensions (W×H×D) | 418 × 232 × 435 mm |
| Net Weight | 43 kg |
| Compliance | CE, BS 410, ISO 3310-1 & -2, ASTM E11, UK Kitemark certified |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Octagon 200CL |
| Price Range | USD 1–4,999 |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Octagon D200 |
| Principle | Electromagnetic 3D vibratory sieving |
| Power Supply | 230 V / 50 Hz / 300 VA or 115 V / 60 Hz / 300 VA |
| Sieve Diameter | 200 mm (8") |
| Max Stack Capacity | 8 full-height or 18 half-height sieves |
| Vibration Frequency | 3000 min⁻¹ (50 Hz) / 3600 min⁻¹ (60 Hz) |
| Max Amplitude | 3.4 mm (50 Hz) / 2.5 mm (60 Hz) |
| Net Weight | 43 kg |
| Dimensions (H × Ø) | 210 mm × 410 mm (excl. support rod) |
| Operating Temperature | 5–35 °C |
| Relative Humidity | 35–90% RH |
| Compliance | BS 410:2000, ISO 3310-1 & -2:2016, ASTM E11-22 |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | SONIC SIFTER |
| Principle | Air-Jet Assisted Vibratory Sieving (Ultrasonically Enhanced) |
| Dimensions (H×D×W) | 508 × 254 × 254 mm |
| Door Opening Height | 623 mm |
| Net Weight | 16.8 kg |
| Gross Weight (incl. packaging) | 28 kg |
| Power Supply | 230 V, 50 Hz, 70 VA / 115 V, 60 Hz, 90 VA |
| Vibration Frequency | 3000 rpm |
| Tap Modes | None / Vertical-only (30 taps/min) / Alternating Vertical & Horizontal (60 taps/min) |
| Sieving Time Range | 0–119 min (0.1-min increments) |
| Sieve Capacity | Up to six full-height standard test sieves OR one precision sieve + four standard sieves (spacer kits required for non-standard stack configurations) |
| Particle Size Range | Down to 5 µm (dry powders) |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | 200 mm / 300 mm |
| Compliance | ISO 3310-1, ISO 3310-2, BS 410-1, BS 410-2, ASTM E11 |
| Certification | UKAS-accredited BSI Kitemark™ |
| Construction | Woven wire mesh (ISO 3310-1) and perforated plate (ISO 3310-2) |
| Frame Material | Brass or stainless steel |
| Available Aperture Ranges | 125 mm – 1 µm (woven), 125 mm – 1 mm (perforated), including full metric, imperial, and Tyler mesh equivalents |
| Traceability | Individual serial number per sieve, accompanied by manufacturer’s certificate of conformity |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | TITAN450 |
| Sieve Diameter Capacity | 450 mm (max) |
| Max Sieve Stacks | 7 |
| Amplitude Range | 0–2 mm (10-step digital control) |
| Vibration Frequency | 3000 rpm @ 50 Hz |
| Particle Size Range | 20 µm – 125 mm |
| Max Sample Load | 20 kg |
| Operating Modes | Dry & Wet Sieving |
| Enclosure Rating | IP54 |
| Power Supply | Single-phase, voltage-configurable |
| Dimensions (D×H) | 606 × 230 mm |
| Net Weight | 140 kg |
| Compliance | CE |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Ultrasonic Cleaner |
| Frequency | 35 kHz |
| Power Output | 2 × 240 W (dual transducer) |
| Tank Capacity | 5.7 L |
| Tank Dimensions | Ø245 mm × 130 mm (H) |
| Maximum Sieve Size Supported | Ø200 mm × 50 mm depth (8" × 2") |
| Timer Range | 0–15 min (digital, adjustable in 1-min increments) |
| Unit Dimensions | Ø260 mm × 260 mm (H) |
| Net Weight | ~5 kg |
| Compliance | CE-marked, RoHS-compliant, designed per ISO 565:2022 and ASTM E11-22 requirements for test sieve maintenance |