Particle/Powder Analysis Instruments
Filter
Showing 241–270 of 969 results
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Endecotts Series |
| Compliance | ISO 3310-1:2016, BS 410:2000, ASTM E11-22 |
| Nominal Aperture Range | 20 µm – 125 mm |
| Available Diameters | 75 mm (3″), 200 mm (8″), 300 mm (12″), 450 mm (18″) |
| Frame Materials | Stainless Steel, Brass, Electroplated Steel |
| Weave Type | Plain Weave, Twill Weave (per specification) |
| Certification | Individual Certificate of Compliance & Calibration Certificate (per ISO 3310-2:2016 Annex B) |
| Traceability | Unique Serial Number per Sieve |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | BS EN ISO 3310-1 / ASTM E11 Compliant Woven Wire Test Sieves |
| Diameter Options | 38, 100, 150, 200, 250, 300, 315, 350, 400, 450 mm & 3", 8", 12", 18" |
| Aperture Range | 20 µm to 125 mm |
| Material Options | Stainless Steel, Brass, Electroplated Steel |
| Compliance | BS 410:2000, ISO 3310-1:2016 & ISO 3310-2:2016, ASTM E11-22, UK Kitemark Certified |
| Traceability | Individual serial number per sieve with accredited calibration certificate |
| Brand | Engelsmann |
|---|---|
| Origin | Germany |
| Model | JEL 200-II |
| Voltage | 230 V |
| Power Consumption | 0.14 kW |
| Net Weight | 27 kg |
| Dimensions (L×W×H) | 665 × 480 × 800 mm |
| Screening Method | Dry & Wet Sieving |
| Design Feature | Low-Profile Mounting for Ball Mill Integration |
| Filtration | Integrated Magnetic Filter with Pressure Sensor |
| Vacuum System | Suspended Vacuum Pump |
| Sample Handling | Hanging Collector Assembly |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Winner2000ZDE |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <2 min per run |
| Laser Source | He-Ne, λ = 632.8 nm, output power >2 mW, lifetime >25,000 h |
| Detector Channels | 39 |
| Standards Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Ultrasonic Dispersion | 40 kHz, 35 W, adjustable duration ≥1 s |
| Stirring Speed | 0–3000 rpm (continuously adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL |
| Dimensions | 860 × 360 × 440 mm |
| Weight | 40 kg |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 1 |
| Pricing | Upon Request |
| Measurement Accuracy | ±2% (150–950 HV) |
| Supported Scales | HB, HV, HRA, HRB, HRC, HR15N, HR15T, MPa |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERACOUNT XS |
| Instrument Type | Optical Particle Counter |
| Calibration Standard | ISO 11171, traceable to NIST |
| Particle Size Channels | 4, 6, 14, 21, 25, 30, 38, 70 µm(c) |
| Measurement Time | as fast as 30 s |
| Sample Volume | 5 mL (at 10 mL/min) or 12.5 mL (at 25 mL/min) |
| Viscosity Range | up to 1000 cSt at 22 °C |
| Operating Temperature | −10 to 50 °C |
| Sample Temperature Range | 5 to 60 °C |
| Maximum Detectable Particle Size | 230 µm |
| Compliance | ISO 4406, ISO 11171, ISO 4402, SAE AS4059 |
| Brand | ERWEKA |
|---|---|
| Origin | Germany |
| Model Series | GTL / GT / GTB |
| Instrument Type | Multi-Method Powder Flowability Tester |
| Measurable Parameters | Angle of Repose, Difference Angle, Dispersibility |
| Maximum Sample Vessel Capacity | 480 mL |
| Minimum Sample Volume | 100 mL |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EyeTech |
| Price Range | USD 110,000–138,000 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–3600 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–60 s |
| Concentration Range | ~10⁹ particles/mL |
| Light Source | Stabilized He–Ne Laser (632.8 nm) |
| Laser Resolution | 0.33% of full scale |
| Detector | Silicon PIN Photodiode |
| Stroboscopic Illumination | Adjustable intensity & pulse duration |
| Camera | High-resolution monochrome CCD |
| Shape Parameters | 40 ISO-compliant morphological descriptors |
| Sample Introduction | Liquid suspension, dry powder, microscope slide-mounted |
| Software Compliance | FDA 21 CFR Part 11 (audit trail, user roles, electronic signatures) |
| Brand | Ankersmid |
|---|---|
| Origin | Netherlands |
| Model | EyeTech Laser Particle Size and Shape Analyzer |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Analyzer |
| Measurement Range | 0.1–3600 µm |
| Repeatability | <1% |
| Measurement Time | 30–60 s |
| Principle | Combined Laser Obscuration (LO) and Dynamic Image Analysis (DIA) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EyeTech-Laser |
| Price Range | USD 27,000 – 41,000 (FOB Rotterdam) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Eyetech-Shape DSA-10 |
| Price | Upon Request |
| Measurement Principle | High-Speed Synchronized Stroboscopic Imaging + Digital Image Analysis |
| Particle Size Range | 1 µm – 6 mm |
| Camera Resolution | 640 × 480 px monochrome CCD |
| Strobe Frequency | 1 Hz or 30 Hz (adjustable) |
| Illumination | Software-controlled variable-intensity stroboscopic light source |
| Optical Configuration | Interchangeable dual-magnification lens system (3 objective lenses included) |
| Focus | Motorized focus control |
| Analysis Speed | >10,000 particles per minute (typical), full geometric characterization per frame in <1 s |
| Output Data | Equivalent circular diameter, projected area, perimeter, aspect ratio, convexity, roundness, solidity, elongation, and custom shape factor distributions |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FM-PR-PDS |
| Instrument Type | Optical Particle Counter |
| Detection Threshold | ≥0.1 µm (PSL-equivalent, NIST-traceable) |
| Throughput | Up to 400 Wafers per Hour (WPH) |
| Dual-Side Inspection | Simultaneous front & back surface imaging |
| Compliance | ISO 14644-9 (Cleanroom classification reporting), Supports SCP (Surface Contamination Particle) grading in PDF and GUI |
| Measurement Mode | Static Field-of-View Imaging (no stage motion during acquisition) |
| Application Scope | DUV/EUV photomask pellicles, reticles, semiconductor wafers, advanced packaging substrates, and precision optical substrates |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Model | FM-PS-PFS-V02 |
| Measurement Principle | Dark-field Mie scattering |
| Measurement Range | 0.5–150 µm |
| Repeatability | ≥90% |
| Measurement Interval | ≤10 s per scan |
| Field of View (FOV) | Ø25 mm (on 50 mm replaceable substrate) |
| Environmental Operation | Ambient pressure and vacuum-compatible |
| Compliance | ISO 14644-9, ISO 14644-17 |
| Output Formats | KLARF, Excel, PDF (ISO-compliant qualification reports) |
| Software | Integrated real-time analysis with annotated imaging and 3D signal profiling |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Model | FM-PS-PFS-V02 |
| Instrument Type | Optical Particle Fallout Monitor |
| Compliance | ISO 14644-9, ISO 14644-17 |
| Detection Threshold | ≥0.5 µm (NIST-traceable) |
| Sampling Interval | Adjustable down to 10 s |
| Substrate | 2-inch silicon wafer |
| Measurement Output | Deposition Rate (DPRL), particle count, size distribution, spatial density, time-resolved deposition profile |
| Brand | Fastmicro |
|---|---|
| Country of Origin | Netherlands |
| Instrument Type | Optical Particle Counter |
| Model | FM-PS-SAS-V01 |
| Sampling Principle | Tape-based Indirect Extraction |
| Minimum Detectable Particle Size | 0.5 µm |
| Field of View | 225 mm² per scan |
| Scan Time | <5 seconds |
| Sample Carriers | Certified PMC Adhesive Cards & 2-inch Wafer Kit |
| Compliance | ISO 14644-1, ISO 14644-7, USP <788>, ASTM E2457 |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Model | FM-W-PDS |
| Instrument Type | Optical Particle Counter |
| Field of View (FOV) | 4–12 inch diameter |
| Detection Principle | Dark-Field Microscopy with High-Resolution Digital Imaging |
| Minimum Detectable Particle Size | ≥0.1 µm |
| Configuration | Manual or Automated Wafer Handling |
| Dual-Side Scanning | Optional |
| Measurement Mode | Static FOV Imaging (No Sample Translation During Acquisition) |
| Compliance | Designed for ISO 14644 Cleanroom Environments, Compatible with SEMI Standards for Wafer Inspection |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Aode305-11231 |
| Product Type | Intelligent |
| Display Interface | PC-based Software |
| Measurement Range | 0.20–50 µm |
| Repeatability | ±3% |
| Porosity Range | 0.25–0.95 |
| Inlet Gas Pressure | 3 kPa |
| Brand | FlowCam |
|---|---|
| Origin | Japan |
| Model | FlowCam 5000 |
| Particle Size Range | 3–300 µm |
| Camera Resolution | 1920 × 1200 pixels (color CMOS) |
| Frame Rate | up to 100 fps |
| Optical Configurations | 4X (300 µm depth), 10X (100 µm depth), 20X (50 µm depth) |
| Sample Flow Rate | 0.05–2 mL/min |
| Max Particle Concentration | 4 × 10⁶ particles/mL (at 3 µm) |
| Dimensions | 44 × 25 × 27 cm |
| Weight | 10 kg (operational), 24 kg (shipping) |
| Power Consumption | ≤92 W |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | Turbiscan AGS |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | up to 95% v/v |
| Temperature Control | 25–60 °C (±0.5 °C) |
| Sample Capacity | 54 positions (3 × 18-well thermostated modules) |
| Scan Resolution | 40 µm along 55 mm height |
| Scan Interval | as low as 20 s per scan |
| Light Source | Pulsed NIR LED (880 nm) |
| Detectors | Synchronized transmission and backscattering photodiodes |
| Compliance | ASTM D7809, ISO 13321, USP <729>, GLP-ready data audit trail |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN LAB |
| Measurement Principle | Static Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Temp. Range | +5 °C above ambient to 60 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Detectors | Dual photodiode (transmission + backscattering) |
| Sample Cell | Cylindrical glass cell (Ø 27.5 mm × H 55 mm), threaded black cap with butyl/PTFE seal |
| Data Acquisition Modes | Full-height scanning (1 scan/20 s) or fixed-position kinetics (1 measurement/s) |
| Max. Scan Programs | 250 |
| Software Output | BS/T vs. time, layer thickness vs. time, particle migration velocity, hydrodynamic diameter (d), volume fraction (φ), mean free path, TSI Stability Index, dispersion index |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN TOWER |
| Detection Principle | Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Sample Capacity | 6 positions |
| Temperature Range | 4–80 °C |
| Temp. Control Accuracy | ±0.1 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm per data point |
| Scan Interval | ≥20 s (user-configurable) |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Measurement Modes | Transmission (T) and Backscattering (BS) |
| Software Compliance | FDA 21 CFR Part 11 ready, audit trail enabled, GLP/GMP-supportive workflows |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN TRI-LAB |
| Light Source | 880 nm NIR LED |
| Sample Volume | 1.5–30 mL |
| Temperature Range | 20–60 °C |
| Sample Capacity | 1–3 positions |
| Concentration Range | 0.0001–95% v/v |
| Measurement Principle | Static Multiple Light Scattering (SMLS) |
| Detection Modes | Simultaneous Transmitted (T) and Backscattered (BS) Light |
| Output Metrics | Turbiscan Stability Index (TSI), Migration Rate, Phase Thickness, Kinetic Index, Mean Hydrodynamic Diameter, Dispersion Ratio, Redispersion Efficiency |
| Brand | Fritsch |
|---|---|
| Origin | Germany |
| Manufacturer | Fritsch GmbH |
| Type | Imported Instrument |
| Model | A-18 |
| Principle | Vibratory Sieving |
| Measurement Range | 20 µm – 125 mm |
| Maximum Load Capacity | 42 kg |
| Number of Sieve Stages | 12 |
| Input Voltage | 230 V, 1~ |
| Frequency | 50–60 Hz |
| Power Consumption | 480 W |
| Max Sample Mass per Run | 6 kg |
| Sieving Time Range | 5–60 min |
| Base Dimensions (W×L×H) | 58 × 58 × 39 cm |
| Net Weight | 92 kg |
| Gross Weight | 129 kg |
| Sieve Diameter Compatibility | 350 mm, 400 mm, 450 mm, or 12", 16", 18" |
| Compliance | ISO 3310-1, ASTM E11-95, ISO 9000 traceable calibration |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Imported Instrument |
| Model | A-22 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3800 µm |
| Repeatability | <0.5% |
| Measurement Time | 10 s |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Manufacturer | FRITSCH GmbH |
| Product Type | Import |
| Model | A-28 |
| Dispersion Method | Dry Dispersion |
| Measurement Range | 20 µm – 20 mm |
| Repeatability | < 0.5% |
| Measurement Time | < 5 min |
| Camera Resolution | 5 MP |
| Optical Configuration | Dual Telecentric Lens System (4 interchangeable lenses) |
| Standards Compliance | ISO 13322-2 |
| Dimensions (W × D × H) | 90 cm × 30 cm × 50 cm |
| Sample Throughput | 10–100 g per measurement |
| Frame Rate | Up to 30 fps |
| Software Platform | FRITSCH ISS Control & Evaluation Software |
| Cloud Integration | FRITSCH Cloud Morphology Analytics |
| Brand | Fritsch |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | A-3 Pro |
| Principle | Vertical vibratory sieving with adjustable amplitude up to 3 mm |
| Measurement Range | Dry method: 32 µm – 63 mm |
| Wet method | 20 µm – 10 mm |
| Micro-sieve option | 5 µm – 100 µm |
| Sample Capacity | Dry ≤100 g (for <100 µm), ≤1 kg (for <25 mm) |
| Wet | 20–100 g |
| Micro-sieve | 0.2–0.5 g |
| Sieving Time | Dry: 3–20 min |
| Wet | 3–10 min |
| Micro-sieve | 30–60 min |
| Max Stackable Sieves | 10 × 50 mm diameter sieves or 16 × 25 mm diameter sieves |
| Sieve Standards | ISO 3310-1/-2, ASTM E11 |
| Compliance Certificates | EN 10204 3.1B, DIN 66165 repeatability validation, ISO 9000-compatible calibration traceability |
| Weight | Net 21 kg, Gross 26 kg |
| Software Interface | AUTOSIEVE PC software (included), supports automated process control, result evaluation, and cross-platform data correlation with laser diffraction particle size analyzers |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 18 |
| Voltage | 230 V, 1~ |
| Frequency | 50–60 Hz |
| Input Power | 480 W |
| Sieving Method | Dry Sieving |
| Sample Condition | Dry |
| Sieving Range (Dry) | 20 µm – 125 mm |
| Max. Sample Load | 6 kg |
| Sieving Time | 5–60 min |
| Dimensions (W×L×H) | 58 × 58 × 39 cm |
| Net Weight | 92 kg |
| Gross Weight | 129 kg |
| Motor Type | Two maintenance-free asymmetric motors |
| Motion Type | Simultaneous horizontal and vertical oscillation |
| Compliance | ISO 3310-1, ASTM E11-95, ISO 9000 traceable calibration |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | Analysette 18 |
| Measurement Principle | Dry Mechanical Vibratory Sieving |
| Max. Sample Capacity | 15 kg (standard), up to 25 kg with optional large-diameter sieve stack |
| Sieve Aperture Range | 20 µm – 125 mm |
| Max. Sieve Diameter | 450 mm (18") |
| Sieving Time | 5–60 min |
| Drive System | Dual Asymmetric Counter-Rotating Motors |
| Compliance | ISO 2591-1, ISO 9276-1, ASTM E11, USP <786> |
| Software | AUTOSIEVE v5.x (FDA 21 CFR Part 11 compliant audit trail & user access control) |
| Brand | Fritsch |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 22 Micro Tec Plus |
| Measurement Range | 0.08–2000 µm |
| Laser Sources | Dual-laser system (green: λ = 532 nm, 7 mW |
| IR | λ = 940 nm, 9 mW), Class 1 safety certified per EN 60825-1 |
| Optical Design | Inverse Fourier configuration with motorized sample cell positioning |
| Detector Array | 57-channel dual-axis (vertical & horizontal polarization) sensor |
| Dispersion Options | Modular dry and wet dispersion units (optional) |
| Compliance | ISO 13320 compliant |
| SOP Architecture | Modular, parameter-independent workflow design |
| Cleaning | Automated rinse cycle |
| Environmental Rating | Dry dispersion compatible with ISO Class 5 (Grade A) cleanroom environments |
| Software | Fully configurable reporting, background subtraction algorithm, tap-water-compatible measurement protocol |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Micro Tec² |
| Pricing | Available Upon Request |